Review of CMC Template. Yoshiya Terao (NMIJ Fluid Flow Div.) WGFF Workshop, June 2012 Abridged for APMP/TCFF meeting, Nov. 2012

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Classification of services in Acoustics, Ultrasound and Vibration

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program

NEW VSL Conditioning plate!

For the National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Applied Fluid Mechanics

Applied Fluid Mechanics

Certificate of Accreditation to ISO/IEC 17025:2005

Two mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW SVCET

INTERNATIONAL KEY COMPARISON OF LIQUID HYDROCARBON FLOW FACILITIES CCM-FF-K2 (Final Report) BIPM Pavillon de Breteuil F Sevres France

The Reynolds Number Correction of Liquid Ultrasonic Meters and Coriolis Meters

Certificate of Accreditation

WGFF Guidelines for CMC Uncertainty and Calibration Report Uncertainty

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

COMPARISON OF INMETRO AND INTI HUMIDITY STANDARDS. Final Report

Flare/Vent Metering. Lex Scheers. If you can t t measure, you can t t manage. Advanced Production Management

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

Using the Coriolis Acceleration to Design a Digital Mass Flow Meter

Roll No. :... Invigilator s Signature :.. CS/B.Tech (EIE)/SEM-5/EI-501/ INDUSTRIAL INSTRUMENTATION II

Certificate of Accreditation

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina

Linearity of Coriolis Flowmeters at Full Scale Value. Dr. Jesús Aguilera - Endress + Hauser Paul Ceglia - Endress + Hauser

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

Public Outreach Meeting. Proposed Revision of Onshore Orders 3, 4, and 5

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ALLOMETRICS, INC Bayport Blvd. Seabrook, TX Terry Baldwin Phone: CALIBRATION

CALIBRATION CERTIFICATE # 503

Certificate of Accreditation

CHAPTER 28 PRESSURE IN FLUIDS

Describe Coriolis Mass Flowmeters

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Relation between Velocity Profile and Friction Factor at High Reynolds Number in Fully Developed Pipe Flow

Certificate of Accreditation

The Uncertainty of Flow Meter Measurement. Mr.Surachart Changpanich Flowlab & Service Co.,Ltd.

FLOW MEASUREMENT VERIFYING YOUR VALUE Small Volume Provers

Flow Measurement in Pipes and Ducts COURSE CONTENT

Measurement And Uncertainty

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

The MMs are 4 KRAL screw meters, normally permanently installed in the BEV test rig as secondary working standards.

Final Report on the APMP Air Speed Key Comparison (APMP.M.FF-K3)

Calibration and Measurement of Micro Liquid Flow APMP 2011 TCFF Workshop Chun-Min Su, Ph.D. CMS/ITRI Dec. 03, Kobe, Japan 1 Content Introductio

The Uncertainty of a Waterdraw Calibration vs. Gravimetric Calibration on Small Volume Provers

Adjustment procedures and their corresponding uncertainties

CERTIFICATE OF ACCREDITATION

Doubt-Free Uncertainty In Measurement

CHAPTER (13) FLOW MEASUREMENTS

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS

CONCEPTS AND DEFINITIONS. Prepared by Engr. John Paul Timola

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Theory and Design for Mechanical Measurements

Training Benefits Adding Values to Your Systems/ Organization through: Potential Attendees These Courses have been designed for;

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

Calibration Models and Uncertainty Analysis of the Euroloop Liquid Hydrocarbon Flow Facility

IGHEM 2016 Linz, August 24 th - 26 th 2016 STATISTICAL ANALYSIS ON EXPERIMENTAL CALIBRATION DATA FOR FLOWMETERS IN PRESSURE PIPES

6.5 Work and Fluid Forces

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

North Sea Flow Measurement Workshop

Engineering Thermodynamics. Chapter 1. Introductory Concepts and Definition

Uncertainty in Humidity Measurement. Helping you make a better measurement.

INDUSTRIAL APPLICATION EXPERIENCES OF NEW TYPE FLOW- METERING SYSTEM BASED ON ULTRASONIC-DOPPLER FLOW VELOCITY-PROFILE MEASUREMENT

CNG measuring systems for vehicles

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

1.4 Perform the following unit conversions: (b) (c) s. g s. lb min. (d) (e) in. ft s. m 55 h. (f) ft s. km h. (g)

Chapter 5: The First Law of Thermodynamics: Closed Systems

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Innovative Solutions from the Process Control Professionals

1. Mark the correct statement(s)

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

Measurement Stations. Length, Mass, Volume, Density, Temperature, and Time

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad AERONAUTICAL ENGINEERING QUESTION BANK : AERONAUTICAL ENGINEERING.

National Voluntary Laboratory Accreditation Program

Measurement Uncertainty Knowing the Unknown

ECE309 THERMODYNAMICS & HEAT TRANSFER MIDTERM EXAMINATION. Instructor: R. Culham. Name: Student ID Number:

Commenting template CEN/TC 102 Date : Document: pren 13060

Final Results of Bilateral Comparison between NIST and PTB for Flows of High Pressure Natural Gas

Keys to the Study of Chemistry. 1.1 Fundamental Definitions

Learning Objectives. Lesson 6: Mathematical Models of Fluid Flow Components. ET 438a Automatic Control Systems Technology 8/27/2015

Corrections related to operation and calibration of liquid flow meters NFOGM Temadag 2016 Morten Marstein, FMC Kongsberg Metering

Propagation of Uncertainties in Measurements: Generalized/ Fiducial Inference

Installation effects on an ultrasonic flow meter with implications for self diagnostics

TYPICAL PRESSURE MEASUREMENT UNCERTAINTY DEFINED BY AN FPG8601 FORCE BALANCED PISTON GAUGE

A MEASUREMENT ASSURANCE PROGRAM FOR LOW FLOW CALIBRATION BY THE TRANSFER METHOD CS20

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

Application of Density Meters to Liquid Hydrocarbon Measurement

REPORT OF SPECIAL TEST

Chem 115 POGIL Worksheet - Week 1 Units, Measurement Uncertainty, and Significant Figures - Solutions

( afa, ( )) [ 12, ]. Math 226 Notes Section 7.4 ARC LENGTH AND SURFACES OF REVOLUTION

Use of Seismic and EM Data for Exploration, Appraisal and Reservoir Characterization

UNIT I Basic concepts and Work & Heat Transfer

ENT 254: Applied Thermodynamics

Law vs. Theory. Steps in the Scientific Method. Outcomes Over the Long-Term. Measuring Matter in Two Ways

Transcription:

Review of CMC Template Yoshiya Terao (NMIJ Fluid Flow Div.) WGFF Workshop, June 2012 Abridged for APMP/TCFF meeting, Nov. 2012

Example of CMC table A B C D E F G H I J K L M N R Current CMC table (Sample) Measurement Conditions/Independent Variable Expanded Uncertainty 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 #1 #2 #3 #4 Class Mass water Volume water Mass hydrocarbon Volume hydrocarbon Calibration or Measurement Service Instrument or Artifact Instrument Type or Method Minimum Maximum Units Parameter Specifications Value Units Covera ge Factor Level of Confide nce Water meter Coriolis 13.9 833 kg/s Fluid water 0.060 % 2 95% Yes Water meter Positive displacement, turbine, differential pressure, ultrasonic, vortex meter, electromagnetic 100 kpa to 250 kpa Is the expande d uncertai nty a 50.0 3000 m 3 /h Fluid water 0.060 % 2 95% Yes Oil meter Coriolis 0.67 67 kg/s Fluid Oil meter Measurand Level or Range Positive displacement, turbine, ultrasonic 3 300 m 3 /h Fluid 100 kpa to 250 kpa hydrocarbon (light oil, kerosene) 0.020 % 2 95% Yes 100 kpa to 700 kpa 10 t, 1 t hydrocarbon (light oil, kerosene) 0.030 % 2 95% Yes 100 kpa to 700 kpa 10 t, 1 t same for mass and volume both numbers have been rounded during calcuration Comments

New proposal Use the smaller uncertainty (mass or volume) as the expanded uncertainty. The larger uncertainty and corresponding flow range should be included in the comments section. The classification needs to be changed accordingly.

Modified according to the new proposal A B C D E F G H I J K L M N R New proposal Measurement Conditions/Independent Variable Expanded Uncertainty 2 3 4 Calibration or Measurement Service Class Water Instrument or Artifact Water meter Instrument Type or Method Coriolis, Positive displacement, turbine, differential pressure, ultrasonic, vortex meter, electromagnetic Measurand Level or Range Minimum Maximum Units Parameter Specifications Value Units Is the Level of expande Coverag Confide d e Factor nce uncertai nty a Comments 50.0 3000 m 3 /h Fluid water 0.060 % 2 95% Yes 5 6 7 8 #1 100 kpa to 250 kpa Information about mass flow rate Mass flow rate: 13.9 to 833 mkg/s 3 /h with same uncertainty 9 10 11 12 13 14 #3 Hydrocar bon Oil meter Coriolis, Positive displacement, turbine, ultrasonic 0.7 67 kg/s Fluid hydrocarbon (light oil, kerosene) 0.020 % 2 95% Yes 100 kpa to 700 kpa 10 t, 1 t Smaller uncertainty Larger uncertainty and corresponding flow range Volume flow rate: 3 to 300 m 3 /h with expanded uncertainty of 0.030 %

Other issues "Instrument Type or Method : The reference flow standard of the calibration service should be written here. Unit: "dm 3 " should be replaces by "L Change Heat flow to Hot water flow or Enthalpy flow?

Example with " Instrument Type or Method " description A B C D E F G H I J K L M N R New proposal Measurement Conditions/Independent Variable Expanded Uncertainty 2 3 4 Class Calibration or Measurement Service Instrument or Artifact Instrument Type or Method 50t weighing Water Water meter tank with flying start and stop Measurand Level or Range Minimum Maximum Units Parameter Specifications Value Units Is the Level of expande Coverag Confide d e Factor nce uncertai nty a Comments 50.0 3000 m 3 /h Fluid water 0.060 % 2 95% Yes 5 6 7 8 #1 the reference flow standard of the calibration service 100 kpa to 250 kpa Information about mass flow rate Mass flow rate: 13.9 to 833 m 3 /h with same uncertainty 9 10 11 12 13 #3 Hydrocar bon Oil meter 10t weighing tank with flying start and stop 0.7 67 kg/s Fluid hydrocarbon (light oil, kerosene) 0.020 % 2 95% Yes 100 kpa to 700 kpa 10 t, 1 t Smaller uncertainty Larger uncertainty and corresponding flow range Volume flow rate: 3 to 300 m 3 /h with expanded uncertainty of 0.030 %