arxiv: v1 [physics.ins-det] 21 Dec 2009

Similar documents
Setup for Triggering Force Testing of Touch Probes for CNC Machine Tools and CMMs

COORDINATE measuring machines (CMM s) have been

MEASUREMENT result besides a measured value should

Journal of Machine Engineering, 2018, Vol. 18, No. 3, 78 86

Uncertainty evaluation for coordinate metrology by intelligent measurement

Assessment of the impact of the articulated probe head angular orientation on the probe head errors distribution

TEMPERATURE COMPENSATION DURING CMM INSPECTION

This document is a preview generated by EVS

A laser metroscope for the calibration of setting rings

Coordinate Measuring Machines Coordinate INDEX Measuring Machines Coordinate Measuring Machines New Products

THE IMPACT OF ALIGNMENT CONDITION IN THE MEASURING PLAN BY USING THE SOFTWARE CALYPSO ON THE REPEATABILITY OF MEASURED VALUES

Comparison of Results Obtained from Calibration of a Measuring Arm Performed According to the VDI/VDE, ASME and ISO Standards

BRIGHT-STRATO SERIES

New concept of a 3D-probing system for micro-components

CRYSTA-APEX C. The modular system for 3D CNC coordinate measurement in the production environment. Quick, versatile and high performing.

THE ACCURACY ANALYSIS OF THE ROUNDNESS MEASUREMENT WITH COORDINATE MEASURING MACHINES

ENG56 DriveTrain. Good practice guide. for surface parameter measurement strategies for form and diameter measurements for large bearings

Different Approaches in Uncertainty Evaluation for Measurement of Complex Surfaces Using Coordinate Measuring Machine

Uncertainty due to Finite Resolution Measurements

Engineering Metrology and Instrumentation

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI. DEPARTMENT OF MECHANICAL ENGINEERING FAQ

ESTIMATION OF UNCERTAINTY IN HARDNESS MEASUREMENT OF RUBBER AND OTHER ELASTOPLASTIC MATERIALS

Creation of the π angle standard for the flat angle measurements

Metrol. Meas. Syst., Vol. XXII (2015), No. 3, pp METROLOGY AND MEASUREMENT SYSTEMS. Index , ISSN

Robotic manipulation in dimensional measurement

ISO INTERNATIONAL STANDARD

CNC Coordinate Measuring Machine MICROCORD CRYSTA-Apex S Series

Achieving traceability of industrial computed tomography

A Unified Approach to Uncertainty for Quality Improvement

Research Collection. Thermal issues in 5-axis machine tools. Conference Paper. ETH Library

ISO INTERNATIONAL STANDARD. Test code for machine tools Part 4: Circular tests for numerically controlled machine tools

Uncertainty of the Measurement of Radial Runout, Axial Runout and Coning using an Industrial Axi-Symmetric Measurement Machine

Supplementary Comparison EURAMET.EM-S19 EURAMET Project No. 688

Metrological Characterization of Hardness Indenter Calibration System

ISO INTERNATIONAL STANDARD

CMM Uncertainty Budget

A hybrid Measurement Systems Analysis and Uncertainty of Measurement Approach for Industrial Measurement in the Light Controlled Factory

Open Access Repository eprint

Revision of CMM performance specifications

A guide to expression of uncertainty of measurements QA4EO-QAEO-GEN-DQK-006

Evaluation of AACMM using the virtual circles method

CRYSTA-APEX S SERIES. High-performance, low-price CNC coordinate measuring machine that meets global standards. Bulletin No MEASURING MACHINES

EXACTNESS IN THE NANOMETER RANGE USED TO BE A UTOPIAN AND THEN THERE WAS PRECIMAR

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

AM Metrology at NPL. Stephen Brown. Tuesday 8 th December 2015

Guide to the Expression of Uncertainty in Measurement (GUM) and its supplemental guides

A combinatorial technique for weighbridge verification

Machine Positioning Uncertainty with Laser Interferometer Feedback

,

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

Feasibility study of the cascading mass ow rate evaluation as a new variant of Gibson's method

Read the following BEFORE getting started:

Final Report on Comparison of Hydraulic Pressure Balance Effective Area Determination in the Range up to 80 MPa

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

DETERMINE PARAMETERS HYDROMECHANICAL BULGE FORMING AXISYMMETRIC COMPONENTS FROM COPPER TUBES. Tomasz Miłek

Annex xxx General guidelines for the assessment of uncertainties in solar thermal systems performance testing

LASER TRAPPING MICRO-PROBE FOR NANO-CMM

Automatic dimension measurement on CNC lathes using the cutting tool

AN EXAMINATION OF SURFACE LOCATION ERROR AND SURFACE ROUGHNESS FOR PERIOD-2 INSTABILITY IN MILLING

Metallic materials Brinell hardness test. Part 3: Calibration of reference blocks

Practical and Valid Guidelines for Realistic Estimation of Measurement Uncertainty in Pesticide Multi-Residue Analysis*

Renewal of the gage-block interferometer at INRIM

Dimensional X-ray Computed Tomography Conference 2016

Measurement & Uncertainty - Basic concept and its application

Temperature Effects in Dimensional Metrology Influences of Temperature on the Accuracy and how to cope with them

SCOPE OF ACCREDITATION

Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60

National Institute of Standards and Technology, b The Boeing Company ABSTRACT

Research Article Two Mathematical Models for Generation of Crowned Tooth Surface

A taxonomy of model-based redundancy methods for CMM online performance verification. Fiorenzo Franceschini* and Maurizio Galetto

T.V. Vorburger, J.F. Song, T.B. Renegar, and A. Zheng January 23, 2008

Traceability of on-machine measurements under a wide range of working conditions

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

Introduction to the evaluation of uncertainty

Temperature and Length. Pieter Greeff October 2013

FORCE STANDARDS COMPARISON BETWEEN PTB (GERMANY) AND CENAM (MEXICO).

Measurement and Calibration of a High-Sensitivity Microwave Power Sensor with an Attenuator

Research Article New Measurement Method and Uncertainty Estimation for Plate Dimensions and Surface Quality

DETERMINATION OF THE TYPE B STANDARD UNCERTAINTY SY oktobar 2015.

The dimensional calibration of piston-cylinder units to be used for pressure metrology and the re-determination of the Boltzmann constant

Estimate of the inertial torque in rotating shafts - a metrological approach to signal processing

DYNAMICS OF THE NON-CONTACT ROUNDNESS MEASUREMENT WITH AIR GAGES

Development of Measuring System for the Non-Repetitive Run-Out(NRRO) of Ball Bearing

Thermal correction - workpiece expansion. Thermal correction - workpiece expansion AP306. Problem

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW

University of Huddersfield Repository

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

In-Process Chatter Detection in Surface Grinding

VERIFICATION OF TAPPING MACHINES. Håkan Andersson

Analysis of the influence of the Spherically Mounted Reflector on the measurements done with Laser Tracker

MODEL: CNC-C600 PRODUCT SPECIFICATION

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 3: Calibration of reference blocks

METHODS FOR CERTIFYING MEASUREMENT EQUIPMENT. Scott Crone

Method of Estimating Uncertainty of Measurement Values in Case of Measurement Methods Involving Non-Linear Calibration

DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Sub Code/Name: ME 1304/Engineering Metrology & Measurements Year/Sem :III/ V UNIT-I

Upgrade of 5m-Bench System for Traceable Measurements of Tapes and Rules at SASO-NMCC Dimensional Laboratory

ISO INTERNATIONAL STANDARD

CRYSTA-APEX S SERIES

A new method for circular testing of machine tools under loaded condition

Transcription:

Noname manuscript No. (will be inserted by the editor) Inertia compensation while scanning screw threads on coordinate-measuring machines Sergey Kosarevsky* Viktor Latypov arxiv:091.448v1 [physics.ins-det] 1 Dec 009 Received: date / Accepted: date Abstract Usage of scanning coordinate-measuring machines for inspection of screw threads has become a common practice nowadays. Compared to touch trigger probing, scanning capabilities allow to speed up measuring process while still maintaining high accuracy. However, in some cases accuracy drasticaly depends on the scanning speed. In this paper a compensation method is proposed allowing to reduce the influence of some dynamic effects while scanning screw threads on coordinate-measuring machines. Keywords scanning CMM accuracy 1 Introduction Numerical compensation of measurement errors is a well developed field of dimensional metrology [1]. This type of compensation originates from different CAA (computer-aided accuracy) methods and is extensively used in modern CMMs and CNC machines during recent years [], [3]. To successfully compensate measurement results one should clearly undertand the exact source of errors. Measuring uncertainty on coordinate-measuring machines depends on many factors. They can be summarized into the following types [4]: * Corresponding author. S.V. Kosarevsky Faculty of Technology, Saint-Petersburg Institute of Mechanical-Engineering, Saint-Petersburg, Russia 195197 E-mail: kosarevsky@linderdaum.com V.N. Latypov Faculty of Applied Mathematics and Control Processes, Saint-Petersburg State University, Saint-Petersburg, Russia 198504 kinematic; thermo-mechanical; loads; dynamic; control software. Some dynamic effects produce non-constant measurement errors varying according to known models. These models depend entirely upon specific measurement task and development of generic model is troublesome. One of the widely accepted example of such kind of model is pretravel compensation [5], [6], [7]. In this paper a novel compensation method is given to reduce minor and major diameters measurement error from dynamic effects emerging while scanning screw threads. Related work Due to inertial forces while high-speed scanning freeform workpieces with low radius of curvature on coordinate-measuring machines it is difficult for the control software to maintain stable contact between the probe and the surface. This is one of the reasons preventing accurate scanning at high speeds [8]. The study of dynamic effects was conducted by many researchers. Application of signal analysis and processing theory to dimensional metrology was studied in [9]. Pereira and Hocken [8] proposed classification and compensation methods for dynamic errors of scanning coordinate-measuring machines. They used Taylor series and Fourier analysis to compensate measurement of circular features. ISO 10360 [11] defines acceptance tests for scanning coordinate-measuring machines. Farooqui and Morse [1] proposed reference artifacts and tests to compare scanning performance of

different coordinate-measuring machines. Szelewski et al. [10] conducted experimental research and concluded that freeform surfaces scanning time reduction is limited at high speeds by acceleration and deceleration of the probing system. 3 Theoretical model of probe inertial motion Fig. : Probing system floating inside the CMM probing head. where is the thread angle. Since the separation δ is axisymmetric (fig. 3) the diameter measurement error is cos F Fig. 1: Scanning thread surface with a spherical probe. Dδ = High-speed longitudinal scanning of a thread surface results in loss of contact between the probe and the thread surface. Because of this coordinate-measuring machine will measure points not belonging to the thread surface. The actual value of the minor diameter (for internal threads) or the major diameter (for external threads) can be distorted. This effect is noticeable at scanning speeds above 5 mm/s and the probing system mass of over 0.1 kg. The helix scanning strategy is free from this effect since no surface part with low radius of curvature is scanned at high speed. Energy conservation yields (fig. 1): 4 Compensation. () The equation () can be used to obtain the diameter compensation formula: D = Dm ± cos F, where D is the compensated diameter, m (fig. 3); Dm is the measured diameter, m. The upper sign applies to internal threads and the lower sign to external threads respectively. m (Vscan N) = F δ, (1) where m is the mass of the probing system floating inside the CMM probing head (fig. ), kg; Vscan is the scanning speed, m/s; F is the contact force, N; N is the unit vector othogonal to the thread axis; δ is the separation of the probe from the surface, m. Assuming that N and F are collinear the separation value δ can be derived from the equation (1): δ= cos F, 5 Experimental verification of the model We scanned the ISO metric screw thread ring gauge M170x6 [13] to measure its minor diameter. The diameter was calculated as the maximal inscribed cylinder with both filtering and outlier elimination disabled. The mass of our probing system was 0.1 kg according to manufacturer s specification, contact force was set in CMM software to 0. N. Theoretical and experimental values for different scanning speeds are summarized in table 1.

3 and no actual mass measurement was performed the calculated compensation values has proven to be useful. Though numerical compensation of the measurement results is a rapidly growing field of dimensional metrology its application to dynamic effects compensation is to be extended. Experimental activities described in this paper confirm the method proposed is able to reduce the influence of interia of the probing system on measurement error of screw thread s minor and major diameters. This method can be easily implemented directly in CMM software to allow automatic inertia compensation. 7 Acknowledgement Fig. 3: Compensated and measured diameters. Experimental values were obtained on a Carl Zeiss PRISMO 10 S-ACC (MP E E = 1.7 + L 350 ) coordinatemeasuring machine. The value of the minor diameter scanned at 1 mm/s was assumed to be the actual value (D δ.exp. = 0). Each of the resulted experimental errors were averaged by 10 measurements. Plots of the estimated error (D δ ), the experimental error (D δ.exp. ) and the compensated error (D δ.exp. D δ ) are displayed in fig. 4. The compensated error is also individually shown in fig. 5. The percentage of error reduction was calculated as ( R = 1 D ) δ.exp. D δ 100%, D δ and is displayed in fig. 6. Quadratic least-squares approximation (black) is shown for reference. 6 Conclusions The most significant error reduction (fig. 6) can be achieved in the interval of scanning speeds from 6 mm/s and up to 1 mm/s. At scanning speeds below 5 mm/s the influence of the studied effect is surpassed by the MP E E value of the tested CMM and cannot be treated unambiguously (note large fluctuations in error reduction at speeds below 5 mm/s). At speeds above 1 mm/s the compensated error is quickly surpassing 0 µm and can be unaccaptable for the most practical applications. Even though the mass of the probing system was taken directly from the manufacturer s specification This work was carried out with the support of the OPTEC Carl Zeiss grant 010, http://optec. zeiss.ru. References 1. ISO GUM 1995 Guide to the Expression of Uncertainty in Measurement. BIPM, IEC, IFCC, ISO, IUPAC and OIML. Second Edition. 1995.. Trapet, E.; Wäldele, F. Coordinate Metrology Flexebility in conflict with accuracy? // Anais Seminário Internacional de Metrologia, Florianopolis SC, 1997. 3. Jenq-Shyong, C. Computer-aided accuracy enhancement for multi-axis CNC machine tool // International Journal of Machine Tools and Manufacture, Vol.35, Issue 4, April 1995, pp. 593-605. 4. Schwenke, H.; Knapp, W.; Haitjema, H.; Weckenmann, A.; Schmitt, R.; Delbressine, F. Geometric error measurement and compensation of machines An update // CIRP Annals Manufacturing Technology, 008, 57, pp. 660-675. 5. Estler, W.T.; Phillips, S.D.; Borchardt, B.; Hopp, T.; Witzgall, C.; Levenson, M.; Eberhardt, K.; McClain, M.; Shen, Y.; Zhang, X. Error compensation for CMM touch trigger probes // Precision Engineering. Vol. 19,, October 1996, pp. 85-97(13). 6. Woźniak, A.; Dobosz, M. Metrological feasibilities of CMM touch trigger probes. Part I: 3D theoretical model of probe pretravel // Measurement. Vol. 34, Issue 4, December 003, pp. 73-86. 7. Woźniak, A.; Dobosz, M. Metrological feasibilities of CMM touch trigger probes. Part II: Experimental verification of the 3D theoretical model of probe pretravel // Measurement. Vol. 34, Issue 4, December 003, pp. 87-99. 8. Pereira, P. H.; Hocken, R. J. Characterization and Compensation of Dynamic Errors of a Scanning Coordinate Measuring Machine // Precis. Eng., 007, 31(1), pp. -3. 9. Hessling, J.P. Dynamic metrology an approach to dynamic evaluation of linear time-invariant measurement systems // Measurement Science and Technology, Vol. 19, 008. 10. Szelewski, M.; Grzelka, M.; Barisic, B. Free surface scanning with CMM and its reproduction in CAD system // Engineering Review, 7-1, 007. pp. 7-1.

4 Table 1: Effect of scanning speed on measurement results. Speed, mm/s Separation δ, µm D δ, µm D δ.exp., µm D δ.exp. D δ, µm Reduction, % 1 0. 0.4 0.0-0.4 0.0 0.8 1.5 0.4-1.1 6.7 3 1.7 3.4 1.8-1.6 53.0 4 3.0 6.0.0-4.0 33.3 5 4.7 9.4 3.1-6.3 33.0 6 6.8 13.5 11.0 -.5 81.5 7 9. 18.4 11.9-6.5 64.7 8 1.0 4.0 31.6 7.6 68.3 9 15. 30.4 37.6 7. 76.3 10 18.8 37.5 46.1 8.6 77.1 11.7 45.4 38.5-6.9 84.8 1 7.0 54.0 40.6-13.4 75. 13 31.7 63.4 80. 16.8 73.5 14 36.8 73.5 90.8 17.3 76.5 15 4. 84.4 13.7 39.3 53.4 Fig. 4: Measurement error versus scanning speed. 11. ISO 10360-4:000 Geometrical Product Specifications (GPS) Acceptance and reverification tests for coordinate measuring machines (CMM) Part 4: CMMs used in scanning measuring mode. 1. Farooqui, A.; Morse P. Methods and artifacts for comparison of scanning CMM performance // Transactions of the ASME, Vol.7, March 007, pp. 7-80. 13. ISO 68-1 ISO general purpose screw threads Basic profile Metric screw threads. 14. ISO 1156:1996 Geometrical Product Specifications (GPS) Surface Texture: Profile Method Metrological Characteristics of Phase Correct Filters (Geneva, Switzerland: International Organization for Standardization).

5 Fig. 5: Compensated measurement error versus scanning speed. Fig. 6: Error reduction.