E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Similar documents
HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

Flow rates to 485 l/min

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters

331 Low & Medium Pressure filters

Flow rates to 750 l/min

Flow rates to 485 l/min

Flow rates to 485 l/min

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

387 Low & Medium Pressure filters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

Flow rates to 475 l/min

AIR BREATHER FILTERS. Temperature from -25 to +100 C

Flow rates to 750 l/min

High Pressure fi lters

SERIES. Maximum pressure 8 bar

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

RFM. 300 kpa (3 bar) Return Filters RFM. Ports: 3/8 2 1/2 Flow rates: l/min

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n

Cooler-Bypass Thermostat Valve, Size 10

K 080/12 F 10 K 3-2X/.. Features

MPT Multifunction Multiport

AIR BREATHER FILTERS. Temperature from -25 C to +100 C

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

Flow rates to 590 l/min

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre

STAINLESS STEEL FILTER

2-way proportional throttle valve for block installation

Polígono Indutrial O Rebullón s/n Mos - España -

CHINA MP FILTRI P.O. Box Shanghai Phone: Fax:

Suction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

VOLUMEC. Valve Position Indicator 5

SERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

Cartridge Valves Technical Information. Quick reference

Direct-operated 2/2-way solenoid valves Type EV210B

Safety valve with unit approval type MV..X.., SV..X..

SERIES INLINE FILTERS LMP 210. Maximum pressure 60 bar Maximum flow to l / mi n

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

MPF SERIES RETURN FILTER

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)

MRH. Return Filters RETURN FILTER

Polígono Indutrial O Rebullón s/n Mos - España -

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min

External gear pump Type G3, Series 3X

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

mandata_us :43 Pagina 83 (1,1) FHB 82

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

VD1 CLC. Small Valves DIN-range with a higher k v -value

FMM 050 uk :26 Pagina 5 (1,1) FMM 050

Cooling Water Flow Regulator

INTERNATIONAL STANDARD

FMP :41 Pagina 5 (1,1) FMP

Nylon oil filler and air breather filler caps

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

PR CYCLONE SECONDARY SHUTOFF

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

Modular Style Air Combination. Assembled by simply tightening the screws

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

ED 701 General Industry Pressure Transmitter

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Conductivity sensor for hygienic applications

Directional spool valve type SWPN Nom. size 6 or 10 conforming DIN

FLOW DIVIDERS "XV 3 serie" ENGLISH VERS:

Direct-operated 2/2-way compact solenoid valves Type EV210A

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

14:1400 (0206) KRAL Volumeter - OMG

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Metal air breather filter

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

Operating Instructions for Digital Manometer. Model: MAN-SD

Maximum pressure 80 bar

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

VISUAL LEVEL INDICATORS

Instruction Manual. Equipment for Engineering Education

SlimLine Sensors (SLS)

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Transcription:

R e t u r n F i l t e rs E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min 20.30-5e

D e s c r i p t i o n Application In the return line circuits of hydraulic systems. Performance features Protection against wear: Protection against malfunction: Special features By-pass valve: By means of filter elements that, in full-flow filtration meet even the highest demands regarding cleanliness classes. By means of full-flow filtration in the system return, the pumps above all are protected from dirt particles remaining in the system after assembly, repairs, or which are generated by wear or enter the system from outside. The location close to the inlet port prevents dirt particles retained by the filter element from entering into the clean oil side. Removable bowl: In case of maintenance the filter bowl is removed together with the filter element - therefore dirt particles are not flushed back into the tank. Filter elements Flow direction from outside to centre. The star-shaped pleating of the filter material results in: large filter surfaces low pressure drop high dirt-holding capacities long service life Ventilating Filter Ventilation of the reservoir by an integral star-shape pleated filter element: removable (replace annually!) splash-proof fineness 2 µm Filter maintenance By using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter life. Materials Screw-on cap: Polyamide, GF reinforced Filter head: Aluminium alloy Filter bowl: Polyamide, GF reinforced* Seals: NBR (Viton on request) Filter media: EXAPOR MAX - inorganic multi-layer microfibre web Paper - cellulose web, impregnated with resin * due to the conductable plastic material no static charge can occur Accessories An optional oil separator (Part No. E 103.1702) prevents oil splashing through the ventilating filter at mobile applications. Electrical and optical clogging indicators are available. Dimensions and technical data see cataologue sheet 60.20. C h a ra c t e r i s t i c s Nominal flow rate Up to 135 l/min (see Selection Chart, column 2) The nominal flow rates indicated by ARGO-HYTOS are based on the following features: closed by-pass valve at ν 200 mm 2 /s element service life > 1000 operating hours at an average fluid contamination of 0,07 g per l/min flow volume flow velocity in the connection lines 4,5 m/s Connection Threaded ports according to ISO 228 or DIN 13. Sizes see Selection Chart, column 6 (other port threads on request) Filter fineness 5 µm(c)... 30 µm(c) β-values according to ISO 16889 (see Selection Chart, column 4 and Diagram Dx) Dirt-holding capacity Values in g test dust ISO MTD according to ISO 16889 (see Selection Chart, column 5) Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG see info-sheet 00.20) With high filling conditions we recommend an electrical conductivity >_ 500 ps/m at 20 C. Temperature range - 30 C... + 100 C (temporary - 40 C... + 120 C) Viscosity at nominal flow rate at operating temperature: ν < 60 mm 2 /s as starting viscosity: ν max = 1200 mm 2 /s at first operation: The recommended starting viscosity can be read from the Diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 70% p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Operating pressure Max. 10 bar Mounting position Preferably vertical, outlet downwards

D i a g ra m s p-curves for complete filters in Selection Chart, column 3 D1 Pressure drop as a function of the flow volume at ν = 35 mm 2 /s (0 = casing empty) Pressure drop as a function of the kinematic viscosity at nominal flow D2 Q [l/min] ν [mm 2 /s] D3 Q [l/min] ν [mm 2 /s] Pressure drop as a function of the flow volume at ν = 35 mm 2 /s (0 = casing empty) Pressure drop as a function of the kinematic viscosity at nominal flow Pressure drop as a function of the flow volume at ν = 35 mm 2 /s (0 = casing empty) Pressure drop as a function of the kinematic viscosity at nominal flow Q [l/min] ν [mm 2 /s] Filter fineness curves in Selection Chart, column 4 Dx Filtration ratio β for particles > x µm Filtration ratio β as a function of particle size x obtained by the Multi-Pass Test according to ISO 16889 Efficiency [%] The abbreviations represent the following β-values resp. finenesses: For EXAPOR MAX- and Paper elements: 5 E-X = β 5 (c) 8 E-X = β 8 (c) 12 E-X = β 12 (c) 16 E-X = β 16 (c) 30 P = β 30 (c) = 200 Paper Based on the structure of the filter media of the 30 P paper elements, deviations from the printed curves are quite probable. For screen elements: 40 S = screen material with mesh size 40 µm 60 S = screen material with mesh size 60 µm 100 S = screen material with mesh size 100 µm Tolerances for mesh size accordung to DIN 4189 For ventilating filter elements: 2 CL = 99,5 % efficiency for particles of size 2 µm Particle size x [µm] (for particles larger than the given particle size x) For special applications, finenesses differing from these curves are also available by using special composed filter material.

S e l e c t i o n C h a r t Part No. Dirt-holding capacity Nominal flow Pressure drop see Diagram D/curve no. Filter fineness see Diagr. Dx Connection A Cracking pressure of by-pass Symbol Replacement element Part No. Weight Replacement ventilating filter Part No. Filter fineness see Diagrams Remarks l/min g bar kg 1 2 3 4 5 6 7 8 9 10 11 12 E 094-661 50 D1/1 30 P 11 G 3 / 4 1,5 2 P3.0613-51 0,8 L1.0503-03 (2 CL) - E 094-671 50 D1/1 30 P 11 G 3 / 4 1,5 1 P3.0613-51 0,8 - - E 103-657 35 D2/1 5 E-X 13 G 1 / 2 2,5 2 V3.0620-53 1,0 L1.0503-03 (2 CL) - E 103-677 35 D2/1 5 E-X 13 G 1 / 2 2,5 1 V3.0620-53 1,0 - - E 103-676 75 D2/2 12 E-X 22 G 3 / 4 2,5 2 V3.0620-56 1,0 L1.0503-03 (2 CL) - E 103-686 75 D2/2 12 E-X 22 G 3 / 4 2,5 1 V3.0620-56 1,0 - - E 103-898 95 D2/3 16 E-X 24 G1 2,5 2 V3.0620-58 1,0 L1.0503-03 (2 CL) - E 103-888 95 D2/3 16 E-X 24 G1 2,5 1 V3.0620-58 1,0 - - E 103-871 70 D2/4 30 P 11 G 3 / 4 1,5 2 P3.0620-51* 1,0 L1.0503-03 (2 CL) - E 103-861 70 D2/4 30 P 11 G 3 / 4 1,5 1 P3.0620-51* 1,0 - - E 143-657 55 D3/1 5 E-X 21 G 3 / 4 2,5 2 V3.0730-53 1,2 L1.0503-03 (2 CL) - E 143-667 55 D3/1 5 E-X 21 G 3 / 4 2,5 1 V3.0730-53 1,2 - - E 143-676 115 D3/2 12 E-X 32 G1 2,5 2 V3.0730-56 1,2 L1.0503-03 (2 CL) - E 143-686 115 D3/2 12 E-X 32 G1 2,5 1 V3.0730-56 1,2 - - E 143-888 135 D3/3 16 E-X 36 G1 2,5 2 V3.0730-58 1,2 L1.0503-03 (2 CL) - E 143-688 135 D3/3 16 E-X 36 G1 2,5 1 V3.0730-58 1,2 - - E 143-851 120 D3/4 30 P 17 G1 1,5 2 P3.0730-51* 1,2 L1.0503-03 (2 CL) - E 143-861 120 D3/4 30 P 17 G1 1,5 1 P3.0730-51* 1,2 - - All filters are delivered with a plugged clogging indicator connection M 12 x 1,5. As clogging indicators either manometers or electrical pressure switches can be used. Optional extension pipes adapt the filter length to various tank depths. For ordering of accessories please use the below mentioned codes. Order example: The filter E 103-676 has to be supplied with an extension pipe for 300 mm length. Order description: E 103-676 / EV 300 Part No. (basic unit) Extension pipe (7 various lengths are available) EV = K (Bowl length) + 19 / + 79 / + 123 / + 173 / + 223 / + 323 / + 423 mm (see dimensions and measurements) For the suitable clogging indicators please see catalogue sheet 60.20. Remarks: The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column 7). The clogging indicators are always delivered detached from the filter. The filters listed in this chart are standard filters. Other designs available on request. * Paper media supported with metal gauze

D i m e n s i o n s Ventilating filter fineness 2 µm (replaceable) Oil separator optional ARGO-HYTOS Part No.: E 103.1702 Dia hole in reservoir Max oil level under stationary conditions when using an oil separator Required mounting surface Design with ventilating filter Connection M12 x 1,5 for clogging indicator Design without ventilating filter M e a s u re m e n t s Type A B C D E F G H I 1 I 2 K L M N O P 1 P 2 Q R S SW U V min./max. E 094 G¾ 105 87 / 91 73,5 38 20,5 30 88,5 235 95 111 115 110 70 11 82 69 13,5 107,5 32 41 50 23 E 103 G½, G¾, G1 105 87 / 91 73,5 38 20,5 30 88,5 300 95 177 115 110 70 11 82 69 13,5 107,5 32 41 50 23 E 143 G¾, G1 105 87 / 91 73,5 38 20,5 30 88,5 400 95 278 115 110 70 11 82 69 13,5 107,5 32 41 50 23 For calculation of EV use data in Selection Chart S y m b o l s 1 2

S p a re Pa r t s 1 2 3 4 5 Pos. Designation Part No. 1 Screw-on cap E 103.0201 2 Seal N 031.0841 3 Compression spring N015.3703 4 Filter element see Chart / col. 9 5 Filter bowl E094 * E 094.0903 5 Filter bowl E103 * E 103.0912 5 Filter bowl E143 * E 143.0903 6 O-ring 69,5 x 3,5 N 007.0703 7 Ventilating filter L1.0503-03K 8 Seal (for versions E 103.0147 without oil separator) 9 Oil separator with Pos. 10 E 103.1702 10 Seal (for versions E 103.0148 with oil separator) * Specify mounting depth in mm 9 10 6 7 The functions of the complete filters as well as the outstanding features of the filter elements assured by ARGO-HYTOS can only be guaranteed if original ARGO-HYTOS spare parts are used. 8 Q u a l i t y A s s u ra n c e Quality management according to DIN EN ISO 9001 To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to the following DIN and ISO standards: DIN ISO 2941 DIN ISO 2943 DIN ISO 3724 Verification of collapse/burst resistance Verification of material compatibility with fluids Verification of flow fatigue characteristics ISO 2942 ISO 3968 ISO 16889 Verification of fabrication integrity (Bubble Point Test) Evaluation of pressure drop versus flow characteristics Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity) Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Our engineers will be glad to advice you in questions concerning filter application, selection as well as the cleanliness class of the filtered medium attainable under practical operating conditions. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. We produce fluid power solutions ARGO-HYTOS GMBH Industriestraße 9 D-76703 Kraichtal Tel: +49 7250 76-0 Fax: +49 7250 76-199 info.de@argo-hytos.com www.argo-hytos.com Subject to change 9107166-e 0905