IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

Similar documents
IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For

TEST REPORT For Company:

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

Morris Products 53 Carey Road, Queensbury, NY 12804

IES LM MEASUREMENT AND TEST REPORT For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

IES LM TEST REPORT For EIKO GLOBAL, LLC

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

Test report of IES LM Approved Method: Electrical and Photometric

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

ENERGY STAR PROGRAM REQUIREMENTS FOR LUMINAIRES (LIGHT FIXTURES) (VERSION 2.0) MEASUREMENT AND TEST REPORT For

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cat# LED Linear High Bay 100W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

LM Test Report. For Elec-Tech International Co., Ltd. T8 LED TUBE Model: XX(XX:41-50)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

GM LIGHTING 9830 W 190th St, Torrance, CA 90503

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC. (Brand Name: IG T ) 3755 Lincoln St. Suite B, Riverside, CA 92503

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Transcription:

IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED10WA19/300/827K-GU24-DIM-G4 Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution Test Engineer: Daniel Duan Report Number: RSZ140512505-10A1 Test Date: 2014-06-14 Report Date: 2014-08-21 Reviewed By: Prepared By: Test Facility: Jeanne Han/Safety Manager 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0. STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

1. Product Description General Information: Two samples were received on 2014-06-12. One was tested in integrating sphere and the other was tested in goniophotometer. Model Tested: Manufacturer: Product Designation: Burning Time Before Test: LED10WA19/300/827K-GU24-DIM-G4 EiKO Global, LLC Omnidirectional LED Lamp 0 hour(for New Products) Rated Values: Rated Voltage/Frequency: Rated Power: Nominal CCT: AC 120V 60Hz 9.8W 2700K 2. Standards Used IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits Related Power Quality Requirements for Lighting 3. Description of Test Equipment Device Manufacture Model No Serial No Test Range Calibration Calibration date due date Integrating Sphere SENSING N/A N/A 1.5meter 2014-03-16 2015-03-16 Power Meter SENSING UI2008 908735 10.0-600.0V 2014-03-12 2015-03-12 Spectral photometer SENSING SPR3000 s0902024 350nm 800nm 2014-03-16 2015-03-16 AC Power Supply ALL Power APW- 105N 970663 0V-300V 50-400Hz 2014-03-12 2015-03-12 Standard Light Source EVERFINE D204 201311 N/A 2013-09-26 2014-09-26 Thermal Meter SENSING N/A N/A 20~30 2014-03-13 2015-03-13 DC Power Supply ITECH IT6154 AC Power Supply EVERFINE VPS1060 PWM 0061 0417 6471 0010 19 0~32V 2014-03-12 2015-03-12 1101006 0-150V 0-300V 2014-03-12 2015-03-12 DC Power Supply EVERFINE WY12010 1009009 30V/5A 2014-03-12 2015-03-12 Power Meter YOKOGAWA WT-210 91KB35700 Goniophotometer EVERFINE GO- R5000 15/30/60/150/300/600 2014-03-12 2015-03-12 V YG108492N10120001 1600mm,3000W/10A 2014-03-04 2015-03-04 Thermal Meter Victor VC230 EE091 0~40 0~90% 2013-04-01 2016-03-31 Standard Light Source EVERFINE D908 1012001 N/A 2014-05-06 2015-05-06 Statement of Traceability: attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI). Report No. RSZ140512505-10A1 Page 2 of 12 The NVLAP Lab Code is 200707-0.

4. Test Method Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25 C±1 C during measurement. And relative humidity is less than 65%. Integrating Sphere System The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. 4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the light output (luminous flux) measurements is U=1.60% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.3(K=2), at the 95% confidence level. Report No. RSZ140512505-10A1 Page 3 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result [Integrating Sphere System] Total operating time for integrating sphere test: 1.0 hour Test orientation: Base up Electrical Measurement Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor 120.0 60.0 0.094 10.2 0.905 Photometric Measurement Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/w) CCT (K) Duv 889.513 2.848 87.207 2717-6.00E-05 Chromaticity Coordinate x y u v u' v' 0.3852 0.3796 0.2271 0.3357 0.2271 0.5035 Color Rendering Index Ra 84.7 R1 R2 R3 R4 83 91 96 83 R5 R6 R7 R8 83 86 87 68 R9 R10 R11 R12 20 77 82 68 R13 R14 R15 85 97 78 Report No. RSZ140512505-10A1 Page 4 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution 1.2 1.0 0.8 0.6 0.4 0.2 0.0 380 440 500 560 620 680 740 800 nm mw nm mw nm mw nm mw nm mw 380 8.938E-04 465 3.939E-02 550 6.263E-02 635 5.765E-02 720 8.116E-03 385 5.252E-04 470 3.277E-02 555 6.496E-02 640 5.356E-02 725 7.086E-03 390 3.442E-04 475 2.785E-02 560 6.707E-02 645 4.937E-02 730 6.255E-03 395 2.640E-04 480 2.636E-02 565 6.917E-02 650 4.512E-02 735 5.458E-03 400 2.298E-04 485 2.769E-02 570 7.103E-02 655 4.095E-02 740 4.808E-03 405 2.712E-04 490 3.045E-02 575 7.286E-02 660 3.695E-02 745 4.276E-03 410 5.801E-04 495 3.399E-02 580 7.455E-02 665 3.319E-02 750 3.776E-03 415 1.624E-03 500 3.793E-02 585 7.570E-02 670 2.971E-02 755 3.391E-03 420 4.225E-03 505 4.145E-02 590 7.674E-02 675 2.643E-02 760 3.000E-03 425 9.282E-03 510 4.452E-02 595 7.696E-02 680 2.343E-02 765 2.771E-03 430 1.692E-02 515 4.714E-02 600 7.682E-02 685 2.059E-02 770 2.485E-03 435 2.701E-02 520 4.944E-02 605 7.600E-02 690 1.811E-02 775 2.260E-03 440 4.026E-02 525 5.151E-02 610 7.434E-02 695 1.591E-02 780 2.082E-03 445 5.718E-02 530 5.364E-02 615 7.197E-02 700 1.391E-02 785 1.887E-03 450 7.016E-02 535 5.584E-02 620 6.912E-02 705 1.219E-02 790 1.758E-03 455 6.450E-02 540 5.803E-02 625 6.580E-02 710 1.064E-02 795 1.643E-03 460 4.953E-02 545 6.035E-02 630 6.180E-02 715 9.275E-03 800 1.587E-03 Report No. RSZ140512505-10A1 Page 5 of 12 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.45 0.40 0.35 0.30 0.30 0.35 0.40 0.45 0.50 sample 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K 4-STEP 2700K 4-STEP 3000K 4-STEP 3500K 4-STEP 4000K 4-STEP 5000K 4-STEP 6500K 7-Step & 4-Step Chromaticity Quadrangles Report No. RSZ140512505-10A1 Page 6 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System] Total operating time for luminous intensity distribution: 2.0 hours Test orientation: Base up Electrical Measurement Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor 120.0 60.0 0.0927 10.33 0.9286 Photometric Measurement Luminous Flux (lm) Efficacy (lm/w) CBCP (cd) S/MH (C0/180) S/MH (C90/270) 931.127 90.14 75.0 1.67 1.69 Luminous Intensity Distribution C0/180 C45/225 C90/270 C135/315 AVG. Beam Angle (50% Imax): 314.4 310.5 312.0 318.6 313.88 Field Angle (10% Imax): 349.1 349.6 348.9 349.3 349.23 Report No. RSZ140512505-10A1 Page 7 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data γ C 0 22.5 45 67.5 90 112.5 135 157.5 0.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 5.0 75.2 75.4 75.6 75.6 75.6 75.5 75.3 75.1 10.0 75.7 76.2 76.4 76.5 76.3 76.1 75.7 75.3 15.0 76.4 77.1 77.4 77.4 77.2 76.8 76.3 75.7 20.0 77.4 78.2 78.6 78.6 78.3 77.7 77.0 76.3 25.0 78.5 79.5 80.0 80.0 79.5 78.8 77.9 77.0 30.0 79.9 81.0 81.6 81.5 80.9 80.0 79.0 77.9 35.0 81.3 82.6 83.2 83.2 82.4 81.2 80.0 78.8 40.0 82.8 84.1 84.9 84.8 83.8 82.3 80.9 79.6 45.0 84.2 85.6 86.5 86.5 85.2 83.3 81.8 80.4 50.0 85.5 86.9 87.9 88.0 86.4 84.2 82.5 81.0 55.0 86.6 87.9 89.1 89.3 87.5 84.8 83.0 81.4 60.0 87.3 88.6 90.0 90.4 88.2 85.1 83.3 81.7 65.0 87.7 88.9 90.6 91.1 88.7 85.2 83.2 81.6 70.0 87.7 88.8 90.7 91.4 88.7 84.9 82.8 81.2 75.0 87.3 88.4 90.4 91.3 88.4 84.3 82.1 80.5 80.0 86.6 87.6 89.8 90.7 87.8 83.4 81.2 79.5 85.0 85.9 86.7 88.9 90.0 87.0 82.6 80.3 78.8 90.0 85.5 86.3 88.4 89.5 86.5 82.2 80.0 78.6 95.0 85.5 86.2 88.3 89.3 86.5 82.3 80.1 78.6 100.0 85.2 86.1 88.1 89.0 86.4 82.4 80.2 78.5 105.0 84.4 85.5 87.4 88.2 85.8 82.0 79.7 77.9 110.0 83.1 84.4 86.1 86.8 84.6 81.0 78.7 76.8 115.0 81.2 82.7 84.3 84.8 82.8 79.5 77.2 75.1 120.0 78.8 80.4 81.9 82.3 80.5 77.6 75.2 73.0 125.0 75.8 77.5 78.9 79.2 77.6 74.9 72.5 70.3 130.0 72.2 74.0 75.3 75.5 74.1 71.7 69.4 67.1 135.0 68.0 70.0 71.2 71.3 70.2 68.0 65.7 63.5 140.0 63.4 65.4 66.6 66.7 65.7 63.9 61.7 59.5 145.0 58.5 60.4 61.6 61.8 61.0 59.3 57.2 55.2 150.0 53.4 55.2 56.3 56.6 55.9 54.5 52.7 50.7 155.0 48.3 49.9 50.9 51.2 50.7 49.6 47.9 46.1 160.0 43.1 44.5 45.5 45.8 45.5 44.6 43.2 41.5 165.0 37.9 39.2 40.3 40.7 40.6 40.1 39.0 37.3 170.0 30.1 30.4 33.5 33.5 33.6 32.4 31.2 29.2 175.0 11.5 15.3 17.7 18.4 17.3 14.5 10.8 6.7 180.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Report No. RSZ140512505-10A1 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.) γ C 180 202.5 225 247.5 270 292.5 315 337.5 0.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 5.0 74.9 74.7 74.6 74.5 74.5 74.6 74.8 75.0 10.0 75.0 74.6 74.4 74.2 74.2 74.4 74.8 75.3 15.0 75.2 74.6 74.3 74.1 74.1 74.4 74.9 75.7 20.0 75.6 74.9 74.4 74.1 74.2 74.5 75.3 76.4 25.0 76.1 75.3 74.7 74.4 74.4 74.9 75.8 77.2 30.0 76.8 75.8 75.1 74.8 74.8 75.3 76.5 78.3 35.0 77.4 76.2 75.5 75.2 75.2 75.8 77.3 79.5 40.0 78.0 76.5 75.7 75.6 75.6 76.3 78.1 80.7 45.0 78.5 76.7 75.9 75.9 76.0 76.7 78.9 81.9 50.0 78.8 76.8 76.0 76.1 76.3 77.0 79.5 83.1 55.0 78.9 76.6 75.8 76.1 76.3 77.1 80.0 84.0 60.0 78.8 76.1 75.3 75.9 76.1 76.9 80.2 84.7 65.0 78.4 75.4 74.6 75.3 75.6 76.4 80.1 85.1 70.0 77.7 74.4 73.7 74.5 74.7 75.6 79.6 85.0 75.0 76.8 73.1 72.5 73.4 73.7 74.6 78.9 84.6 80.0 75.7 71.9 71.3 72.4 72.6 73.5 78.0 83.8 85.0 74.9 71.2 70.6 71.7 71.9 72.9 77.3 83.1 90.0 74.8 71.1 70.6 71.6 71.8 72.8 77.2 82.9 95.0 74.9 71.3 70.7 71.6 71.8 72.8 77.2 82.8 100.0 74.9 71.3 70.5 71.3 71.5 72.6 77.0 82.5 105.0 74.3 70.8 70.0 70.5 70.8 72.0 76.3 81.6 110.0 73.3 70.0 69.0 69.3 69.7 71.0 75.1 80.2 115.0 71.8 68.7 67.6 67.7 68.1 69.5 73.4 78.2 120.0 69.8 67.0 65.7 65.6 66.0 67.5 71.2 75.7 125.0 67.3 64.7 63.3 63.1 63.5 65.1 68.5 72.7 130.0 64.3 61.8 60.4 60.1 60.5 62.1 65.3 69.2 135.0 60.8 58.6 57.1 56.7 57.2 58.7 61.7 65.1 140.0 57.0 55.0 53.5 53.0 53.5 54.9 57.6 60.7 145.0 52.9 51.1 49.7 49.1 49.4 50.7 53.1 55.9 150.0 48.6 47.2 45.7 45.0 45.2 46.3 48.4 50.8 155.0 44.1 43.2 41.7 40.8 40.8 41.7 43.4 45.5 160.0 39.8 39.4 38.0 36.9 36.6 37.2 38.6 40.3 165.0 35.3 35.2 34.1 32.4 31.8 32.6 33.9 34.2 170.0 26.3 26.1 23.5 21.1 21.9 22.4 23.2 21.7 175.0 1.9 2.3 0.9 0.1 0.0 0.8 3.3 4.6 180.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Report No. RSZ140512505-10A1 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure Angle: 90.00. Flux out: 143.9 lm. Height (m) Diameter (cm) E avg (lx) E max (lx) 0.5 100.0 183.2 300.4 1.0 200.0 45.8 75.1 1.5 300.0 20.4 33.4 2.0 400.0 11.5 18.8 2.5 500.0 7.3 12.0 3.0 600.0 5.1 8.3 3.5 700.0 3.7 6.1 4.0 800.0 2.9 4.7 4.5 900.0 2.3 3.7 5.0 1000.0 1.8 3.0 Report No. RSZ140512505-10A1 Page 10 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement Deg Flux (lm) % Deg Flux (lm) % 0-5 1.8 0.19 0-5 1.8 0.19 5-10 5.4 0.58 0-10 7.2 0.77 10-15 9.0 0.96 0-15 16.1 1.73 15-20 12.5 1.35 0-20 28.7 3.08 20-25 16.1 1.73 0-25 44.8 4.81 25-30 19.6 2.11 0-30 64.4 6.92 30-35 23.1 2.48 0-35 87.5 9.40 35-40 26.5 2.85 0-40 114.1 12.25 40-45 29.8 3.20 0-45 143.9 15.45 45-50 32.8 3.53 0-50 176.7 18.98 50-55 35.6 3.82 0-55 212.3 22.80 55-60 38.1 4.09 0-60 250.4 26.89 60-65 40.1 4.30 0-65 290.4 31.19 65-70 41.6 4.47 0-70 332.1 35.66 70-75 42.7 4.59 0-75 374.8 40.25 75-80 43.3 4.64 0-80 418.0 44.89 80-85 43.5 4.67 0-85 461.5 49.56 85-90 43.5 4.67 0-90 505.0 54.23 90-95 43.5 4.67 0-95 548.4 58.90 95-100 43.1 4.63 0-100 591.5 63.53 100-105 42.2 4.54 0-105 633.8 68.07 105-110 40.8 4.38 0-110 674.6 72.45 110-115 38.8 4.17 0-115 713.4 76.62 115-120 36.4 3.90 0-120 749.8 80.52 120-125 33.4 3.59 0-125 783.2 84.11 125-130 30.2 3.24 0-130 813.4 87.35 130-135 26.6 2.86 0-135 840.0 90.21 135-140 23.0 2.47 0-140 863.0 92.68 140-145 19.3 2.07 0-145 882.2 94.75 145-150 15.7 1.68 0-150 897.9 96.43 150-155 12.3 1.32 0-155 910.1 97.75 155-160 9.2 0.98 0-160 919.3 98.73 160-165 6.4 0.69 0-165 925.7 99.42 165-170 3.9 0.42 0-170 929.6 99.84 170-175 1.4 0.15 0-175 931.0 99.99 175-180 0.1 0.01 0-180 931.1 100.00 Report No. RSZ140512505-10A1 Page 11 of 12 The NVLAP Lab Code is 200707-0.

6. Product Photo LED10WA19/300/827K-GU24-DIM-G4 LED10WA19/300/827K-GU24-DIM-G4 ***********END OF REPORT*********** Report No. RSZ140512505-10A1 Page 12 of 12 The NVLAP Lab Code is 200707-0.