D.C. RESISTIVITY INVESTIGATION OF SUBSURFACE LAYERING FOR GEOTECHNICAL APPLICATION IN MILLENNIUM CITY, KADUNA, KADUNA STATE.

Similar documents
The Use of Vertical Electrical Sounding (VES) for Subsurface Geophysical Investigation around Bomo Area, Kaduna State, Nigeria

Relevance of 2D Electrical Imaging in Subsurface Mapping: Case Study of National Animal Production Research Institute (NAPRI), Zaria.

S.I. Fadele, M.Sc. 1 ; P.O. Sule, Ph.D. 1 ; and B.B.M. Dewu, Ph.D * ABSTRACT

Geophysical Investigation of Foundation Condition of A Site in Ikere- Ekiti, Ekiti State, South-Western Nigeria

FIG. 1 TOPOLOGY MAP SHOWING THE SURVEY AREA.

Full Length Research Article

TWO DIMENSIONAL ELECTRICAL IMAGING OF THE SUBSURFACE STRUCTURE OF BOMO DAM ZARIA, KADUNA STATE NORTH CENTRAL NIGERIA

GEO-ELECTRIC INVESTIGATION OF THE GROUNDWATER POTENTIAL DISTRIBUTION WITHIN GWALE LOCAL GOVERNMENT AREA OF KANO STATE NIGERIA

GEOTECHNICAL INVESTIGATION OF THE SUBSURFACE FORMATIONS, USING ELECTRICAL RESISTIVITY METHOD IN NORTHERN PART OF PAIKO TOWN, NIGER STATE, NIGERIA

FADELE S.I, JATAU B.S AND PATRICK N.O Nasarawa State University, Keffi, Nigeria

Morenikeji P. Anjorin, B.Tech. 1 and Martins O. Olorunfemi, Ph.D. 2*

Elijah Adebowale Ayolabi, Ph.D. 1, Adetayo Femi Folorunso, M.Sc. 2*, Ayodele Franklin Eleyinmi, B.Sc. 1, and Esther O. Anuyah, B.Sc.

K. A. Murana, P. Sule, A.L. Ahmed, E.M. Abraham and E.G. Obande. 1. Introduction

Subsurface Characterization using Electrical Resistivity(Dipole-Dipole) method at Lagos State University (LASU) Foundation School, Badagry

Index Terms- Apparent Resistivity, Aquifer, Geoelectric Section, Piezometric Surface.

2-D RESISTIVITY IMAGING SURVEY FOR WATER-SUPPLY TUBE WELLS IN A BASEMENT COMPLEX: A CASE STUDY OF OOU CAMPUS, AGO-IWOYE SW NIGERIA

Case Study: University of Connecticut (UConn) Landfill

Ground Magnetic and Electrical Resistivity Mapping for Basement Structurs over Charnokitic Terrain in Ado-Ekiti Area, Southwestern Nigeria

Vertical electrical sounding (VES) for subsurface geophysical investigation in Kanigiri area, Prakasam district, Andhra Pradesh, India

Analysis of electrical resistivity data for the determination of aquifer depth at Sapele RD in Benin city

International Journal of Scientific & Engineering Research, Volume 7, Issue 3, March ISSN

SEISMIC REFRACTION INVESTIGATION OF THE SUBSURFACE STRUCTURE AT THE SOUTHERN PART OF NIGER STATE COLLEGE OF EDUCATION, MINNA, NIGERIA

EVALUATION OF GROUNDWATER POTENTIAL USING ELECTRICAL RESISTIVITY METHOD IN OKENUGBO AREA, AGO - IWOYE, SOUTHWESTERN, NIGERIA.

ENGINEERING GEOPHYSICAL STUDY OF THE CONVOCATION SQUARE, KADUNA STATE UNIVERSITY.

Ethiopian Journal of Environmental Studies and Management Vol. 6 No

Vertical Electrical Sounding Survey for Groundwater Exploration in Parts of Anyigba and its Environs, in the Anambra Basin of Nigeria

Geophysical Investigation: A Case Study of Basement Complex, Nigeria

GROUNDWATER INVESTIGATION USING GEOPHYSICAL METHODS- A CASE STUDY OF PYDIBHIMAVARAM INDUSTRIAL AREA

Groundwater Detection in Basement Complex of Northwestern Nigeria using 2D Electrical Resistivity and OffsetWenner Techniques

A Geophysical Investigation for Subsurface Characterization and Structural failure at the Site of a Building, Southwestern Nigeria

Groundwater Assessment in Apapa Coast-Line Area of Lagos Using Electrical Resistivity Method

CHARACTERIZATION OF SOIL PROFILE OF DHAKA CITY USING ELECTRICAL RESISTIVITY TOMOGRAPHY (ERT)

MICRO LEVEL GEO-RESISTIVITY SURVEY THROUGH V.E.S. TEST FOR GROUNDWATER FEASIBILITY STUDY AND SELECTION OF BORE WELL SITES IN PIPILI BLOCK OF PURI

AN APPRAISAL OF CERTAIN CHARACTERISTICS OF AQUIFER IN CHIKUN LOCAL GOVERNMENT AREA OF KADUNA, NIGERIA

Groundwater Exploration In Parts Of Mangu- Halle North-Central Nigeria.

Evaluation of Groundwater Potential and Subsurface Lithologies in Unilorin Quarters Using Resistivity Method

Electrical Resistivity Investigation for Ground Water in Parts of Pegi, Federal Capital Territory, Nigeria

Anomaly effects of arrays for 3d geoelectrical resistivity imaging using orthogonal or parallel 2d profiles

LITHOLOGIC CHARACTERISTICS OF PARTS OF THE CRYSTALLINE BASEMENT COMPLEX OF NORTHERN NIGERIA IN RELATION TO GROUNDWATER EXPLOITATION

Geophysical Investigation of the Precambrian Marble Occurrence in Itobe Area, Central Nigeria

International Journal of Science and Research (IJSR) ISSN (Online): Index Copernicus Value (2013): 6.14 Impact Factor (2013): 4.

Relevance of Geophysics in Road Failures Investigation in a Typical Basement Complex of Southwestern Nigeria.

A Hydro-Geophysical Investigation of Groundwater Potential

Adebayo O. Ojo, M.Sc. 1* and Martins O. Olorunfemi, Ph.D *

Hydro-Geophysical Study of River Niger Floodplain at Jebba-North, Nigeria

Causes of Borehole Failure in Complex Basement Terrains: ABUAD Case Study, Southwestern Nigeria. w w w. a j e r. o r g Page 192

Hamed Aber 1 : Islamic Azad University, Science and Research branch, Tehran, Iran. Mir Sattar Meshin chi asl 2 :

IJSER. Keyword: Hydraulic conductivity, transmissivity, groundwater, aquifer, groundwater,vertical electrical sounding (VES).

6th Rural Water Supply Network Forum 2011 Uganda. Rural Water Supply in the 21st Century: Myths of the Past, Visions for the Future

Application of Remote Sensing and Geo-Electrical Method for Groundwater Exploration in Khor Al Alabyad, North Kordofan State, Sudan

Use of VLF Electromagnetic and Electrical Resistivity Methods for Groundwater Investigation in Oke Amu Area, Southwestern Nigeria

GSJ: Volume 6, Issue 4, April 2018, Online: ISSN

2-D Resistivity Study: The Horizontal Resolution Improvement by Introducing the Enhancing Horizontal Resolution (EHR) Technique

DELINEATION OF ALL-SEASON-RECHARGED GROUNDWATER RESERVOIR FROM TWO VALLEYS, ZARIA, NIGERIA

Geophysical Investigation for Aquifer Potential Assessment and Groundwater Development at EKSU Staff Quarters GRA Ado Ekiti, Southwest Nigeria

Electrical Resistivity Imaging of a Coal Deposit at Tai Area of Gombe State, North Eastern Nigeria

Investigation of Underground Water at Paiko Using Vertical Electrical Sounding Technique in Paiko, Nigeria

Geophysical Investigation of Ground Water Using Vertical Electrical Sounding and Seismic Refraction Methods

Groundwater Sustainability at Wadi Al Bih Dam, Ras El Khaimah, United Arab Emirates (UAE) using Geophysical methods

Groundwater Investigation in Parts of Kaduna South and Environs using Wenner Offset Method of Electrical Resistivity Sounding

URBAN HYDROLOGY: WATER IN THE CITY OF TSHWANE Plant Sciences Auditorium, University of Pretoria January 2014 URBAN HYDROGEOLOGY

Groundwater Potential Evaluation of College of Engineering, Afe Babalola University, Ado-Ekiti, Southwestern Nigeria

Scholars Research Library. Geophysical investigation of effects of topographic complexities on groundwater potential in Ibusa, Delta State Nigeria

A Preliminary Geophysical Reconnaissance Mapping of Emirau Ground Water Resource, Emirau Island, New Ireland Province, PNG

Geophysical Study of Limestone Attributes At Abudu Area of Edo State, Nigeria

Application of Vertical Electrical Sounding (VES) In Delineating Ground Water Potential in Some Part of Jalingo, Taraba State North Eastern Nigeria

Geophysical Investigation of the Causes of Borehole Failure in the Crystaline Basement Complex: A Case Study of Kaura Area of Kaduna State, Nigeria

SITE INVESTIGATION 1

International Journal of Basic and Applied Sciences Raibu et. al., Vol. 1 No. 2 ISSN: (A peer reviewed International Journal)

Ground-Water Exploration in the Worthington Area of Nobles County: Summary of Seismic Data and Recent Test Drilling Results

Fracture Determination Using Azimuthal Schlumberger and Offsetwenner Array in Basement Complex of Northwestern Nigeria

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 3, ISSUE 10, OCTOBER 2014 ISSN

IARJSET. International Advanced Research Journal in Science, Engineering and Technology. Vol. 5, Issue 11, November 2018

Geophysical Investigation of a Suspected Foundation Failure at Ogbomoso, Southwestern, Nigeria.

A TWO-DIMENSIONAL ELECTRICAL RESISTIVITY IMAGING OF AN EARTH DAM, ZARIA, NIGERIA

INTERNATIONAL JOURNAL OF GEOMATICS AND GEOSCIENCES Volume 3, No 1, 2012

Electrical Resistivity Prospecting for Groundwater in the South Eastern part of Ilorin Metropolis, Southwestern Nigeria.

Identification of aquifer zones by VES method: A case study from Mangalore block, Tamil Nadu, S. India

GEOTECHNICAL ENGINEERING II. Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1

INTEGRATED GEOPHYSICAL INVESTIGATION OF SEQUENCE OF DEPOSITION OF SEDIMENTARY STRATA IN ABAKALIKI, NIGERIA ABSTRACT

1. Resistivity of rocks

Lima Project: Seismic Refraction and Resistivity Survey. Alten du Plessis Global Geophysical

2- D Electrical Imaging And Its Application In Groundwater Exploration In Part Of Kubanni River Basin- Zaria, Nigeria

Hydrogeo-Electric Characteristics of Upper River Shemankar Basin, Jos Plateau: A Case Study of Jibam and Environs.

2D Resistivity Imaging Investigation of Solid Waste Landfill Sites in Ikhueniro Municipality, Ikpoba Okha Local Government Area,Edo State, Nigeria.

Surface Processes Focus on Mass Wasting (Chapter 10)

PROCEEDING, SEMINAR NASIONAL KEBUMIAN KE-8 Academia-Industry Linkage OKTOBER 2015; GRHA SABHA PRAMANA

Geoelectrical Soundings to Investigate Groundwater Potential of Orisunmibare Village in Ilorin South Area of Kwara State, Nigeria

RESISTIVITY IMAGING AND BOREHOLE INVESTIGATION OF THE BANTING AREA AQUIFER, SELANGOR, MALAYSIA. A.N. Ibrahim Z.Z.T. Harith M.N.M.

Geoelectricity. ieso 2010

Hydrogeophysical investigation in selected parts of Irepodun/Ifelodun local government area of Ekiti State, Southwestern Nigeria

THE MINISTRY OF ENERGY AND ENERGY INDUSTRIES MINERALS DIVISION MINE DESIGN TEMPLATE OPERATOR NAME: OPERATOR ADDRESS: PHONE NUMBER: FACSIMILE:

Characterization of Transmissivity Attributes of Fractured Aquifers from Geo-electrical models: Matuu, Kenya 1*

Delineation of Groundwater Prospective Zones by Schlumberger electrode array in Bangriposi block of Odisha

EFFECT OF DYNAMIC PATTERN OF THE SAPROLITIC ZONE AND ITS BASEMENT ON BUILDING STABILITY: A CASE STUDY OF A HIGH-RISE BUILDING IN OGBOMOSO.

The Efficacy of Enhancing Horizontal Resolution (EHR) Technique in Shallow Subsurface Study Using 2D Resistivity Method at Bukit Bunuh

Electrical prospecting involves detection of surface effects produced by electrical current flow in the ground.

GEOELECTRICAL INVESTIGATION OF GROUNDWATER CONDITION IN OLEH, NIGERIA

Geophysical Investigation for Engineering Site Development around Galadimawa-Aleita Area, Abuja, North Central Nigeria

Geophysics for Environmental and Geotechnical Applications

Transcription:

Full Length Research Article D.C. RESISTIVITY IVESTIGATIO OF SUBSURFACE LAYERIG FOR GEOTECHICAL APPLICATIO I MILLEIUM CITY, KADUA, KADUA STATE. Dogara M. D., Aboh H. O. and Kogi K. A. Department of Physics, Kaduna State University, Kaduna igeria. ABSTRACT Vertical Electrical Sounding (VES) method of Direct Current Resistivity was -carried out at the South Eastern part of the Millennium City, Kaduna, Kaduna State, orth-western, igeria using the Schlumberger array, with the aim of obtaining information on the subsurface layering for geotechnical application. From the interpreted data, geoelectric and geologic sections and some specialized maps were produced. It is suggestive that the area is underlain by three to five layers. The first layer resistivity and thickness are found to range from 66Ωm to 8343Ωm and 0.39m to 9.4m respectively. The weathered/fractured basement layer, which forms the aquifer, is found to have resistivity and thickness ranging from 36Ωm to 656Ωm and 10.0m to 48.7m respectively. The basement, which forms the final layer, having an infinite thickness, is found to have resistivities ranging from 1016Ωm to 14399Ωm. Competent zones for geotechnical applications within the study area were found to be at VES L1/2, VES L1/3, VES L1/4, VES L1/5, VES L1/6, VES L2/3, VES L2/4, VES L2/5, VES L3/2, VES L5/1 and VES L5/2. VES L1/3 was however, found to possess all the characteristics of competence in relation to surface resistivity, first layer thickness, basement resistivity and depth to basement and hence was considered to be the most competent. Keywords: Competent, Subsurface, D. C. Resistivity, Geotechnical, Geologic Sections, Thickness. ITRODUCTIO Urban development, whether it is within cities, expansion of existing cities or creation of new cities, is largely driven by economic, political and social trends. The incidence of building failures and collapses has become a major issue of concern, affecting urban development in igeria as a nation and even the world, as the frequencies of their occurrence and the magnitude of the losses in terms of lives and properties are now becoming very alarming. This problem is found to be as a result of faulty design, negligence, incompetence, faulty construction, foundation failures, extraordinary loads, corruption and absence of proper site and soil investigation to determine suitability of the terrain and soil s bearing capacity, which influences foundation types and spells out danger. Although ground conditions rarely prohibit development entirely, they do introduce material planning considerations including flood risk, development of contaminated land, and capacity of subsurface infrastructure wankwoala and Warmate, (2014). and Warmate, (2014). The Vertical Electrical Sounding (VES) is a Direct Current Resistivity tool of geophysics for the determination of the subsurface structure of a place. It has been used extensively for the determination of the aquifer potential for the drilling of boreholes. These days, it is used for in-depth geotechnical studies to determine the suitability of a site for the building of heavy structures including high rise buildings, bridges and stadia (Igboekwe, et al. 2012). Hence, the method can be used in the study of the subsurface layering of a place, to provide information that will help in determining the nature of soil at the site and its stratification, selecting the type and depth of foundation suitable for a given structure, determining potential foundation problems (e.g., expansive soil and collapsible soil) and determining the depth and nature of bedrock, if and when encountered. Location and Geology of the Study Area The study area is located at the South-Eastern part of the Kaduna Millennium City, Kaduna State, orth-western, igeria. The study area (Fig. 1) is approximately centred between Latitudes 10 31'00'' and 10 31'21'' and longitude 7 30'15"E and 7 30'37''E. It has a total area of about 200,000m 2 and located in the South Eastern part of sheet 123 Kaduna S.E map, at a height of about 610m above sea level. A brief geology of the study area shows that, Kaduna State, lies within the Basement Complex of orthern part of igeria. The rocks of the area are mostly Precambrian in age and have been subjected to several phases of deformation, the latest being the Pan African Orogeny Aboh, (2009). During this deformation, the basement produced orth-south trending basins of metasediments in the form of synclinoria. The rock types of the basement are mainly granites, gneisses, migmatites, peltic schist, metaconglomerates, marbles and calc-silicate rocks, basic schist, amphibolites and basalts, quartzites and quartz schist, charnockites and fayalite granites (Dogara, 1995). According to Eigbefo, (1978), the superficial deposits, which overlie the basement rocks, act as recharge materials, especially where they are underlain by weathered basement. The main aquifer components of the basement complex of igeria are weathered and fractured basement Oluwu, (1967); Adamu, (1991) and water yielding capacities of wells drilled to these components always vary. The geotechnical evaluation of subsoil condition of a site is necessary in generating relevant data inputs for the design and construction of foundations for proposed structures wankwoala 30

The potential difference, V, across electrodes M and is VM V. (7) *( ) ( )+ (8) [ ( ) ( ) ] (9) If the body is inhomogeneous like the study area, apparent resistivity (ρa) is considered, Fig. 1: Map of study area showing VES points. Theory of Vertical Electrical Sounding Vertical electrical sounding is a Direct Current Resistivity method which measure vertical variation of resistivity with depth (Paranis, 1986). This is achieved based on the assumption that the surface is to be homogeneous and isotropic (Abdullahi and Udensi, 2008). From Ohm s law, the current I and the potential V in a metal conductor at constant temperature are related as follows; (1) Where R is the constant of proportionality known as resistance, measured in ohms. The resistance R, of a conductor is related to its length L and cross sectional area A, by (2) Where ρ is the resistivity, and it is a property of the material considered. From (1) and (2), (3) Using the Schlumberger configuration (Fig. 2), a potential gradient is measured at M and when current electrodes located on the surface of the equipotential surface is semi-spherical downward into the ground at each electrode. The surface area will be 2πL 2, where L is the radius of the sphere. Thus, (4) By deduction then, the potential at M (VM), due to the two current electrodes, is ( ) (5) Similarly, the potential at electrode (V) is given by ( ) (6) Where r1, r2, r3 and r4 are shown in Fig. 2. ( ) (10) Where ρa is apparent resistivity in ohm-metre, and, [ ( ) ( ) ] (11) K is called the geometric factor whose value depends on the type of electrode array used. For Schlumberger array, if and, then, ( ) (12) Data Acquisition and Interpretation Vertical Electrical Sounding (VES) data was collected on 30 VES stations using the Schlumberger configuration. The VES stations were arranged on five profiles labelled L1, L2, L3, L4 and L5 each of length 500m, with each of these profiles having six VES stations, 100m away from each other. The maximum current electrode separation AB/2 being 100m and maximum potential electrode spacing M/2 being 5m was used. The data was acquired using the Ohmega Resistivity meter and its accessories and the field data was interpreted using the Computer software, RES1D version 1.00.07 Beta. RESULTS AD DISCUSSIO From the results obtained from the interpretation, a borehole well log after Ephraim, (2016) and resistivity range of earth materials after Mohammed, et al. (2007), Jatau, et al. (2013), Dogara, (1995), Talabi and Ayodeji, (2015) and Abdullahi, et al. (2014), Aboh, (2002) and geologic sections were constructed for the five profiles. The geoelectric and geologic sections for profile 3 (Fig. 3), which gives a fair representation of the other profiles due to its centrality, shows that the profile is underlain by four layers. The resistivity of the first layer which is made up of clay soil, laterite and indurated laterite was found to range from 387Ωm to 2100Ωm, and has a thickness ranging from 0.4m at VES L3/6 to about 4.3m at VES L3/4. The second layer, whose resistivity values range from 271Ωm to 680Ωm and thickness ranging from 4.0m at VES L3/4 to 11.8m at VES L3/6, is made up majorly of Sandy/Silty clay. The third layer, made up majorly of the weathered basement, has its resistivity values ranging from 49Ωm to about 202Ωm. The thickness of this layer was found to range from 11.5m at VES L3/3 to 24.2m at VES L3/4. The fourth layer, which is the final layer, was found to have resistivity values ranging from 1074Ωm to 7164Ωm, and infinite thickness, suggesting that it is the fresh basement. Fig. 2: Schlumberger Electrode Array 31

Fig. 3: Geoelectric and Geologic Section for Profile L3 Some specialized contour maps for the first layer and basement were produced using a contouring package, suffer version 11 to help in the determination of the competent zones for geotechnical application within the study area. Fig. 4 was produced by contouring the first layer resistivity values obtained from the computed data for all the VES points. The map which was produced with a contour interval of 200Ωm was produced to show the variation of resistivity of the first layer. The resistivity of the first layer has an average of 1281Ωm and ranges from 66Ωm at VES L1/6 to 8343Ωm at VES L1/3. According to Abdullahi and Udensi, (2008), areas with high resistivity of top layer >800 Ωm consisting of consolidated thick laterite cover, may be good for engineering and construction purporses. Hence, areas coloured green and red on the map are found to be the best areas for construction purposes, with the red coloured area being the most competent. The areas with low resistivity values, coloured yellow, according to Fadele, et al. (2013) is an indication that the materials are saturated with water, and erecting massive structures along this area is not advisable, but rather structures of low load bearing capacity. Fig. 5 is the map of the first layer thickness, shows how thick or thin various points of the first layer are within the entire study area. The first layer thickness ranges from 0.39m at VES L3/6 to 9.4m at VES L2/3, with an average of 2.7m. The areas coloured green and red are areas where the thickness is greater than 1.5m. According to wankwoala and Warmate (2014), the normal shallow foundation level range from 1.0 to 2.0 metres. Hence, the regions coloured green and red in the map are seen to have thicknesses greater than the minimum depth of the normal shallow foundation, which imply their suitability for siting structures, example high rise buildings, bridges, etc. Fig. 5: First Layer Thickness Map A comparison of figures 4 and 5, shows that all the areas of high resistivity (with the exception of VES L2/6, VES L3/1, VES L3/2 and VES L3/6) coincide with areas of thickness greater than the minimum depth of normal shallow foundation, making them areas capable of accommodating heavy structures. Fig. 6 is the fresh basement resistivity map having a contour interval of 500Ωm. The resistivity of the fresh basement is found to range from 1016Ωm around VES L4/1 to 14399Ωm around VES L1/3, with an average of 3462Ωm. According to Abdullahi and Udensi (2008), regions with high fresh basement resistivity (>6000)Ωm) are areas of high competence, hence in this work, the regions coloured red are competent areas for civil works. Aboh and Osazuwa (2000), Aboh (2002) and Abdullahi and Udensi (2008) said that the resistivity of the basement is a function of the degree of weathering and hence its strength. This implies that basement rocks with low basement resistivity values <2000Ωm within the study area should be avoided for siting any heavy structure. The depth to basement map (Fig. 7) and the orthographic projection map of overburden thickness (Fig. 8) were produced using the values of depth to basement, to show the variation in thickness of the overburden. The depth to basement varies from 13.6m at VES L4/2 to 55.6m at VES L2/4, having an average of 34.2m. The regions coloured red in the map (Fig. 6) show areas of shallow depth <30m (after Abdullahi and Udensi, (2008)). According to Mohammed, et al. (2007), areas with shallow basement and high resistivity values imply the areas are favorable for high - rise structures. Therefore, comparing the map of basement resistivity (Fig. 6) and that of depth to basement (Fig. 7), it can be seen that the areas of red colour coincidence are found only at VES L1/3, VES L1/6 and VES L3/2, making them part of the competent zones. Fig. 4: Isoresistivity Map of First Layer 32

Also, Abdullahi and Udensi (2008), said that areas with depth to basement >45m might be buried valleys or underground structural traps, which might be suitable for usage as seawage or disposal sites. Hence, areas on the map coloured yellow are recommended for construction of waste disposal structures. However, due to their relatively high basement resistivity values, VES L1/4, VES L1/5, VES L2/4 and VES 2/5 have been found to be the best areas for the construction of waste disposal structures within the study area, since the underlying basement rocks at these points are not fractured or heavily weathered, and therefore could not serve as contaminant transport pathways. Fig. 6: Isoresistivity Map of Fresh Basement Conclusion From this work, the areas found to meet the conditions of high resistivity value and high thickness of top layer for siting heavy structures are VES L1/2, VES L1/3, VES L1/4, VES L1/5, VES L2/3, VES L2/4, VES L2/5, VES L5/1 and VES L5/2. Also, areas found to meet the conditions of high basement resistivity and shallow depth to basement, are found to be at VES L1/3, VES L1/6 and VES L3/2. Hence, these areas have been found to be the competent zones within the study area, and are good for the construction of high rise buildings, roads and bridges. However, within these, there are areas that exhibit both acceptable properties of competence in surface resistivity, surface thickness, depth to basement and basement resistivity. The VES that satisfies these conditions is VES L1/3, and hence could be described as the most competent Fig. 7: Depth to Basement Map Fig. 8: Orthographic Projection Map of Overburden Thickness REFERECES Abdullahi,. K., and Udensi, E. E. (2008). Vertical Elecrcal Soundimg Apllied to Hydrogeologic and Engineering Investigation: A Case Study of Kaduna Polytechnic Staff Quarters, igeria. igerian Journal of Physics, 20 (1). Abdullahi,. K., Udensi, E. E., Iheakanwa, A., and Eletta, B. E. (2014). Geo-electrical Method Applied to Evaluation of Groundwater Potential and Aquifer Protective Capacity of Overburden Units. British Journal of Applied Science & Technology, 4 (14). Aboh, H. O. (2009). Assessment of the Aquifers in some Selected Villages in Chukun Local Government Area, Kaduna State, igeria. Science World Journal 4. Aboh, H. O. (2002). Geotechnical Characterization of Subsurface Materials in Kaduna Area, Kaduna State, igeria. Zuma Journal of Pure & Applied Science, 4 (2). Aboh, H. O., & Osazuwa, I. B. (2000). Lithilogical Deductions from a Regional Geoelectric Investigation in Kaduna Area, Kaduna State. igerian Journal of Physics, 12. Adamu, E. A. (1991). Source and recharge of groundwater in the basement. Journal of African Earth Sciences 13 (2), 229-234. Dogara, M. D. (1995). D.C Resistivity Investigation of the Groundwater potential in Romi Chikun Local Government Area Kaduna State igeria. Unpublished M.Sc. Thesis, Department of Physics, Ahmadu Bello University, Zaria. 33

Eigbefo, C. (1978). Hydrology of Kubani drainage basin, Zaria. Unpublished M.Sc Thesis, Department of Geology, Ahmadu Bello University, Zaria. Ephraim, W. (2016). Dept. of Minerals and Petroleum Resources Engineering, Kaduna Polytechnic. Personal Discussion. Fadele, S. I., Jatau, B. S., and Goki,. G. (2013). Subsurface Structural Characterization of Filatan Area A, Zaria Kano Road, using the 2D Electrical Resistivity Tomography. Journal of Earth Sciences and Geotechnical Engineering, 3 (1). Igboekwe, M. U., Ihekweaba, G., Eke, A. B., and Adama, J. C. (2012). The Use of Vertical Electrical Sounding (VES) in the Evaluation of Erosion in Abia State University, Uturu and Evirons. The Pacific Journal of Science and Technology, 13, 509. Mohammed, L.., Aboh, H. O., and Eminike, E. A. (2007). A Regional Geoelectric Investigation for Groundwater Exploration in Minna Area. Science World Journal, 2 (3). wankwoala, H. O., and Warmate, T. (2014). Subsurface Soil Characterization of a Site for Infrastructural Development Purposes in D/Line, Port Harcourt, igeria. American International Journal of Contemporary Research, 4 (6). Oluwu, J. (1967). Preliminary Investigation of Groundwater Condition in Zaria. GS Report. Talabi, A. O., and Ayodeji, K. O. (2015). Vertical Electrical Resistivity Sounding for Groundwater in Bishini Area of Kaduna State. IMPACT: International Journal of Research in Applied, atural and Social Science, 3 (1). Jatau, B. S., Patrick,. O., Baba, A., and Fadele, S. I. (2013). The Use of Vertical Electrical Sounding (VES) for Subsurface Geophysical Investigation Around Bomo Area, Kaduna State, igeria. IOSR Journal of Engineering, 3 (1). 34