ZICOS - New project for neutrinoless double beta decay experiment using zirconium complex in liquid scintillator -

Similar documents
FIRST RESULT FROM KamLAND-Zen Double Beta Decay with 136 Xe

Next Generation Scintillation Detectors: Development of Quantum Dot Doped Scintillator. Lindley Winslow University of California Los Angeles

XMASS: a large single-phase liquid-xenon detector

Two Neutrino Double Beta (2νββ) Decays into Excited States

arxiv: v1 [physics.ins-det] 1 Feb 2016

-> to worldwide experiments searching for neutrinoless double beta decay

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

CANDLES Search for Neutrino-less Double Beta Decay of 48 Ca

KamLAND. Studying Neutrinos from Reactor

Distillation purification and radon assay of liquid xenon

Neutrinos in Nuclear Physics

Kinematic searches. Relativity. Uncertainty. Best candidate: Using molecular tritium, daughter will be Kai Zuber 25

KamLAND. Introduction Data Analysis First Results Implications Future

Status of the AMoRE experiment searching for neutrinoless double beta decay of 100 Mo

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

CANDLES Experiment Current Status and Future Plan. X. Li for the CANDLES Collaboration

Analyzing Data. PHY310: Lecture 16. Road Map

GERDA experiment A search for neutrinoless double beta decay. Roberto Santorelli (Physik-Institut der Universität Zürich)

PoS(FPCP2017)024. The Hyper-Kamiokande Project. Justyna Lagoda

Results from EXO 200. Journal of Physics: Conference Series. Related content PAPER OPEN ACCESS

Search for double electron capture on 124 Xe with the XMASS-I detector

0νββ Physics in WbLS. Andy Mastbaum University of Pennsylvania. WbLS Workshop LBNL 17 May 2014

a step forward exploring the inverted hierarchy region of the neutrino mass

Search for Neutrino-less Double Beta Decay with CANDLES

Neutrino Physics with SNO+ Freija Descamps for the SNO+ collaboration

Reconstruction algorithms in the Super-Kamiokande large water Cherenkov detector

Neutrinoless Double Beta Decay. Phys 135c Spring 2007 Michael Mendenhall

Neutrino oscillation physics potential of Hyper-Kamiokande

Neutrinoless Double Beta Decay for Particle Physicists

Measuring directionality in double-beta decay and neutrino interactions with kiloton-scale scintillation detectors

Background rejection techniques in Germanium 0νββ-decay experiments. ν=v

Excited State Transitions in Double Beta Decay: A brief Review

Neutrinoless double beta decay with SNO+

An Underground Laboratory for a Multi-Detector Experiment. Karsten Heeger Lawrence Berkeley National Laboratory

Studies of the XENON100 Electromagnetic Background

anti-compton BGO detector

Scintillation detectors

A Trial of Neutrino Detection from Joyo Fast Research Reactor

Count. Count. 200mm. PMT scintillation. PMT flourescence. PMT fluorescence. PMT fluorescence. PMT fluorescence. 50mm. 42mm

Measurements of liquid xenon s response to low-energy particle interactions

Finding an Upper Bound on Neutrinos Mass

Finding Neutrinos Mass Upper Bound

Liquid Scintillator Timing Property

Search for Neutrinoless Double-Beta Decay Using Fast Photo-Detectors and Quantum-Dot-Doped Scintillators

Study of absorption and re-emission processes in a ternary liquid scintillation system *

arxiv: v1 [physics.ins-det] 3 Feb 2011

NuSOnG Detector Resolution, Calibration, and Event Separation

arxiv: v1 [physics.ins-det] 23 Oct 2007

Welcome to neutrino nuclear physics

Status and Perspectives of the COBRA-Experiment

KamLAND-Zen Experiment for Zero Neutrino Double Beta Decay Search

arxiv: v1 [nucl-ex] 7 Sep 2009

First results on neutrinoless double beta decay of 82 Se with CUPID-0

Separating Double-Beta Decay Events from Solar Neutrino Interactions in a Kiloton-Scale Liquid Scintillator Detector By Fast Timing

Status of Cuore experiment and last results from Cuoricino

Directional Measurement of Anti-Neutrinos with KamLAND

arxiv: v1 [hep-ex] 14 May 2015

Neutrino Experiments with Reactors

K. Zuber, TU Dresden INT, Double beta decay experiments

GERDA: The GERmanium Detector Array for the search for neutrinoless decays of 76 Ge. Allen Caldwell Max-Planck-Institut für Physik

The GERmanium Detector Array

Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments

can be read by PMTs w/o wave length shifter

Synthesis of plastic scintillator. Ildefonso León Monzón Universidad Autónoma de Sinaloa

The NEMO experiment. Present and Future. Ruben Saakyan UCL 28 January 2004 IOP meeting on double beta decay Sussex

The Factors That Limit Time Resolution for Photon Detection in Large Cherenkov Detectors

Direct dark matter search with XMASS. K. Abe for the XMASS collaboration

PoS(HQL2018)054. Search for 0νββ Decay with EXO-200 and nexo. Guofu Cao 1. On behalf of EXO-200 and nexo collaboration

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

A Large Liquid Scintillator Detector for Neutrino Mass Hierarchy : RENO-50

Light yield measurements of scintillator cocktails for use in detectors of neutrinoless double beta decay

Neutrino Masses and Mixing

Survey of the performance of scintillation materials at low temperatures

Measurement of 2b2ν Half-Life of Zr96. and. Lightguide Studies for SuperNEMO Calorimeter

XMASS 1.5, the next step of the XMASS experiment

Performance of the MCP-PMT for the Belle II TOP counter

Recent Nucleon Decay Results from Super-Kamiokande

arxiv: v2 [hep-ex] 8 Dec 2015

AMoRE 0 experiment using low temperature 40 Ca 100 MoO 4 calorimeters

Neutrinoless Double Beta Decay within the Interacting Shell Model

Low Background Experiments and Material Assay. Tessa Johnson NSSC Summer School July 2016

Neutron flux measurement using fast-neutron activation of 12 B and 12 N isotopes in hydrocarbonate scintillators

Background Free Search for 0 Decay of 76Ge with GERDA

500m. 1000m. /POT/GeV/cm 2. (GeV) E ν 10-14

Neutrino Physics. Neutron Detector in the Aberdeen Tunnel Underground Laboratory. The Daya Bay Experiment. Significance of θ 13

LUCIFER. Marco Vignati INFN Roma XCVIII congresso SIF, Napoli, 21 Settembre 2012

Majorana Double Beta Decay Search Project (Majorana Demonstrator)

Detection and measurement of gamma-radiation by gammaspectroscopy

LIQUID XE DETECTOR FOR MU E GAMMA SEARCH

Double Beta Decay Committee to Assess the Science Proposed for a Deep Underground Science and Engineering Laboratory (DUSEL) December 14-15, 2010

I. 2. Reduction of the Gamow-Teller Matrix Element for the β-decay in 70 Ga- 70 Zn by the 35-MeV (p,n) Reaction on 70 Zn

Available online at ScienceDirect. Physics Procedia 61 (2015 ) K. Okumura

The Nature and Magnitude of Neutrino Mass

The DarkSide-50 Outer Detectors

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

arxiv: v1 [nucl-ex] 14 May 2013

So, you want to build a neutrino detector?

Is the Neutrino its Own Antiparticle?

Wavelength Shifting Reflector Foils for Liquid Ar Scintillation Light

PoS(NEUTEL2017)007. Results from RENO. Soo-Bong Kim. for the RENO collaboration Seoul National University, Republic of Korea

Transcription:

ZICOS - New project for neutrinoless double beta decay experiment using zirconium complex in liquid scintillator - Yoshiyuki Fukuda Department of Physics, Faculty of Education, Miyagi University of Education, Sendai, Miyagi 98-845, Japan E-mail: fukuda@staff.miyakyo-u.ac.jp Abstract. A liquid scintillator containing a tetrakis (isopropyl acetoacetato) zirconium has been developed for new project of neutrinoless double beta decay experiment (ZICOS experiment). We have synthesized a tetrakis (isopropyl acetoacetato) zirconium, which have high solubility (over 31.2 wt.%) in anisole. We measured the performance of liquid scintillator containing 1 wt.% concentration of a tetrakis (isopropyl acetoacetato) zirconium, and obtained 48.7 ± 7.1 % of the light yield of BC55 and the energy resolution of 4.1 ±.6 % at 3.35 MeV assuming 4 % photo coverage of the photomultiplier, respectively. We also estimated that ZICOS experiment should be sensitive to m ν <.1 ev assuming g A = 1.25, g pp = 1.11 and QRPA model, if a radius of the inner detector is 1.5 m and the detector is filled with this liquid scintillator with an enriched 96 Zr nucleus and we can reduce 28 Tl backgrounds to be one tenth order of magnitude of KamLAND-Zen using Cherenkov lights. 1. Introduction To determine the Majorana neutrino mass from neutrinoless double beta decay (νββ), we must measure the half-life. The half-life of νββ is given by following formula. [T1/2 ν (+ + )] 1 = G ν Mν 2 m ν 2 m 2 e Here G ν is the kinematic phase space factor, M ν is the matrix element of the target nucleus including Fermi, Gamow-Teller and tensor contributions, m e is the electron mass, and m ν is the effective Majorana neutrino mass. According to Eq.(1), we must be able to measure a half-life of the order of 1 25 years assuming the neutrino mass to be below.1 ev. On the other hand, the half-life can also be experimentally expressed by following relation. T ν 1/2 a MT E B Here a is the abundance of the target isotope, M is the target mass, T is the measurement time, E is the energy resolution, and B is the background rate. According to Eq.(2), nextgeneration νββ experiments should have tonnes of target isotope, a background rate of.1 1 counts/(tonne year), and an energy resolution of 3.5 % at 3.35 MeV. (Alternatively we could combine a relatively low target mass with very high energy resolution.) (1) (2)

2. ZICOS experiment We are going to search for νββ signal using nucleus 96 Zr in the liquid scintillator. This experiment is named Zirconium COmplex in liquid Scintillator (ZICOS) experiment for neutrinoless double beta decay search. The spherical detector will be filled with a liquid scintillator which contains a high concentration of tetrakis (isopropyl acetoacetato) zirconium (Zr(iprac) 4 ). If the radius of this detector is 1.5 m, then total volume is 14.1 m 3. This detector is located in an outer cylindrical tank as shown in the left panel of Fig 1, which is 5.4 m in diameter and is 5 m in height, assuming EGADS tank which located in the Kamioka mine [1]. This tank should be filled with a pure water in order to identify the passing muons and to exclude external γs and neutrons. Photomultiplier will be mounted on the wall of both an inner detector and an outer cylindrical tank. The photo coverage of the inner detector should be 4 % in order to collect the scintillation light efficiently. 5.m 5.4m Figure 1. The left panel shows the conceptual design of the ZICOS detector. The spherical inner detector will be filled with a liquid scintillator which contains high concentration of Zr(iprac) 4. The middle panels shows the chemical structure formula of Zr(iprac) 4 and the right panel shows a sample liquid scintillator containing 1 wt.% concentration of Zr(iprac) 4. A nucleus 96 Zr has a Q-value of 3.35 MeV, which is the third largest value in possible double beta decay nuclei, and 3 % natural abundance. We choose an anisole (methoxybenzene) as a solvent, because it can dissolve Zr(iprac) 4 with high concentration. Our standard scintillator cocktail is produced by dissolving 1 mg PPO (2,5-Diphenyloxazole) and 1 mg POPOP (1,4- bis(5-phenyloxazol-2-yl) benzene) in 2 ml anisole. The light yield of the standard cocktail is almost same as BC55 and the decay time is 2 ns. The complex Zr(iprac) 4 is not commercial product, therefore we have to synthesize it by ourselves. The chemical structure formula of Zr(iprac) 4 is shown in the middle panel of Fig. 1, and the chemical formula of Zr(iprac) 4 is Zr(CH 3 CCOCHCOOCH(CH 3 ) 2 ) 4 (MW=663.87). Synthesized Zr(iprac) 4 was a white powder. We measured the solubility of Zr(iprac) 4 in anisole and they were over 31.2 wt.%. This corresponds to 7g/L for the solubility of Zr metal. This quite high values makes us to realize tons scale experiment with small size of detector for low backgrounds and low systematic errors. Indeed a quit transparent scintillator cocktail even for the 1 wt.% concentration of Zr(iprac) 4 was obtained as shown in the right panel of Fig. 1. An absorption peak of Zr(iprac) 4 was found at 278 nm. The overlap region between the absorption spectrum of Zr(iprac) 4 and the emission spectrum of anisole is smaller than the case of Zirconium (IV) Acetylacetonate [2], therefore we could expect good performance of liquid scintillator even if 1 wt.% concentration of Zr(iprac) 4 dissolved in anisole.

3. Performance of liquid scintillator The performance of a liquid scintillator from the point of view of νββ should be evaluated by its energy resolution. To distinguish between 2νββ and νββ and avoid energetic γ rays from 214 Bi and 28 Tl which are the progeny of 238 U and 232 Th chains, our initial goals should be that (a) the light yield should be larger than 6% that of BC55, and (b) the energy resolution should be 3.5 % at 3.35 MeV for a 1 wt.% concentration of Zr(iprac) 4. We measured liquid scintillator samples with several concentrations of Zr(iprac) 4. The left panel of Fig. 2 shows the measured light yield fraction for the standard cocktail as a function of the concentration of Zr(iprac) 4. The light yield could be fitted by using following Eq.(3). Relative light yield to the standard cocktail 1..8.6.4.2 PPO.5 wt.% PPO 1.5 wt.% PPO 4.8 wt.% 2. 4. 6. 8. 1. concentration [wt.%] Energy resolution at 1.3MeV electron [%] 35. 3. 25. 2. 15. 1. 5. PPO.5 wt.% PPO 1.5 wt.% PPO 4.8 wt.% 2. 4. 6. 8. 1. concentration [wt.%] Figure 2. The left panel shows the measured light yield fraction to standard cocktail as a function of the concentration of Zr(iprac) 4 in case of the concentration of PPO as.5 wt.%, 1.5 wt.% and 4.8 wt.%. The right panel shows the measured energy resolution as a function of the concentration of Zr(iprac) 4 in case of same concentration of PPO. Both light yield and energy resolution are recovered by increasing the concentration of PPO with an order of 5 wt.% Light yield fraction = η 1 N P P O η 1 N P P O + η 2 N Zr (3) Here, η 1 and η 2 show the absorbance of PPO and zirconium β-keto ester complex per mole, and N P P O and N Zr show the amount of PPO and zirconium β-keto ester complex in mole unit. We assume the emission photon could be absorbed by both PPO and Zr(iprac) 4 with a probability in proportion to the number of molecular and the absorbance, because each absorption spectral shape of PPO and Zr(iprac) 4 are almost similar. According to the solid line in left panel of Fig. 2 which is fitted by Eq(3), the light yield fraction is expected to be almost 15 % at 1 wt.% concentration of Zr(iprac) 4. This number is quite smaller than our goal. The right panel of Fig. 2 shows the measured energy resolution as a function of the concentration of Zr(iprac) 4. It appears that the energy resolution obeys the usual expectation σ = σ, where E, E, and σ correspond to the electron energy, the reference energy, and E/E the energy resolution for the reference energy, respectively. The energy should be proportional to the light yield so that we used same relation of Eq.(3) as a function of concentration of Zr(iprac) 4. The energy resolution obtained by solid line around 1 wt.% concentration was 35 % at 1.3 MeV. The photo coverage of the measurement setup was estimated to be about 9.3 % using Monte Carlo simulation. On the other hand, the ZICOS detector will have 4 % photo coverage of the photomultiplier, so that the energy resolution for the ZICOS detector should be 9.4 % at 3.35 MeV. This value is also quite larger than our goal. Therefore, we have to improve the liquid scintillator system in order to get both larger light yield and better energy resolution.

According to Eq.(3), the light yield also should be in proportion to fraction of the amount PPO molecular with respect to the amount of Zr(iprac) 4 molecular. In other words, we could be able to modify the light yield of our liquid scintillator system, if we add more PPO in samples. The dotted and dashed lines in the left panel of Fig. 2 show the expected light yield fraction as a function of the concentration of Zr(iprac) 4 using above equation in the case of PPO 1.5 wt.% and 4.8 wt.%, respectively. Also the energy resolution will be modified by same equation as shown in the right panel of Fig. 2. Actually, if we use the concentration of PPO as 5 wt.% in 1 wt.% concentration of Zr(iprac) 4, the energy resolution is estimated by 4.1 ±.6 % at 3.35 MeV assuming 4 % photo coverage of photomultiplier. Therefore we achieved our goal for the liquid scintillator system. 4. Sensitivity of ZICOS experiment for νββ search An experimental results of νββ for 96 Zr were obtained by NEMO-3 experiment [3]. A lower limits of the life-time was T ν 1/2 > 9.2 121 years and an upper limit of the neutrino effective mass was also m ν < 7.2 1.8 ev, if nuclear parameters of g A = 1.25 and g pp = 1.11, and the nuclear matrix model QRPA were used. ZICOS experiment will use 216 kg of zirconium which includes 6.5kg of 76 Zr. This corresponds to 9.2 kg of 136 Xe which means that.3 times to KamLAND-Zen[4]. Assuming same energy resolution, background rates, and the measurement time as those of KamLAND-Zen, we can estimate the sensitivity for the lifetime measurement to be T1/2 ν > 4.4 124 years for ZICOS experiment. However, this is not enough for νββ search. In order to increase sensitivity, we have to use some improvements. One improvement is an enrichment. NEMO-3 experiment used 7g of 96 Zr with an enriched to 57.3 % for their target [5]. If we can use 58.5 % enrichment of 96 Zr, which is a commercial grade, then the amount of 96 Zr will be 126 kg. This corresponds to.56 times 136 Xe 32 kg of KamLAND-Zen, and the lifetime limits is obtained by T1/2 ν > 1.1 125 years. This is quite 1155 times longer than NEMO-3 limits. Using Eq.(2), it corresponds to m ν <.16.3 ev assuming same parameters of g A = 1.25, g pp = 1.11 and QRPA model. Another improvement is to reduce backgrounds around 3.5 MeV region. According to recent analysis of KamLAND-Zen, they found that those backgrounds consist of decay products from 28 Tl (β and 2.6 MeV γ) both inside of liquid scintillator and the balloon film. In order to remove those backgrounds, we have to not only increase the energy resolution but also use another technique such as Cherenkov lights. 5. Cherenkov lights using for background reduction The number of photons generated by the Cherenkov radiation is calculated by following formula. dn 55nm dx = 2πz2 α sin 2 dλ θ c 4nm λ 2 = 277z2 sin 2 θ c photon/cm (4) A refractive index of anisole is 1.518, so that the light yield of Cherenkov light is 118 photon/cm above 4nm. The Cherenkov light below 4nm should be absorbed by PPO for a re-emission of scintillation. On the other hands, the light yield of scintillation for anisole is almost 12, photon/mev, and the range of 1 MeV electron in anisole is almost.8cm, so that the yield ratio of Cherenkov light and scintillation light should be order of 1 %. In order to confirm the light yield of Cherenkov lights, we used UV cut filter (SC-37) which cuts lights below 4 nm for the measurement of only Cherenkov light. The left panel of Fig. 3 shows the pulse height distribution of no filter, which include not only scintillation lights from anisole (most of them should be less 4 nm) but also Cherenkov lights. The right panel shows only Cherenkov lights above 4 nm using filter. The difference between

those amounts corresponds to the light yield of scintillation from anisole, and then the yield ratio is experimentally obtained by 2.8 %. The measured value is almost consistent with the number of observed events 3 25 2 15 1 5 SC-37 filter off (observed both Scintillation lights and Cherenkov lights) Mean : 314.9 Sigma : 127.7 Data BG Data Subtracted number of observed events 2 18 16 14 12 1 8 6 4 SC-37 filter on (observed only Cherenkov lights) Mean : 158.9 Sigma : 44.7 Data BG Data Subtracted 2 1 2 3 4 5 6 7 8 9 1 ADC channel 1 2 3 4 5 6 7 8 9 1 ADC channel Figure 3. The left panel shows the pulse height distribution of no filter, therefore the light includes both scintillation and Cherenkov. The right panel shows only Cherenkov light distribution above 4 nm, which is obtained by using SC-37 UV cut filter. expectation within a statistical error. If we can select photomultiplier which detects Cherenkov lights among all hits, then we may be able to distinguish νββ events and the backgrounds due to the inconsistency of vertexes. For the purpose, we will use the difference of time spread of Cherenkov light (less than 1 ns) and scintillation light (2 ns), which is also argued in Ref.[6]. 6. Conclusion A tetrakis (isopropyl acetoacetato) zirconium has a absorption peak at 278 nm and the narrow absorption spectrum makes less overlapping with the emission spectrum of anisole, so that we have succeeded to obtain that the liquid scintillator containing 1 wt.% concentration of Zr(iprac) 4 has 48.7 ± 7.1 % relative to BC55 for the light yield and the 4.1 ±.6 % at 3.35 MeV for the energy resolution in case of 4 % photo coverage of photomultiplier. We could estimate the ZICOS experiment should have the sensitivity of m ν <.1 ev, if we use both 58.5 % enriched 96 Zr and a further background reduction method using Cherenkov light in order to achieve one tenth order of magnitude of KamLAND-Zen. Acknowledgments This work was supported by a Grant-in-Aid for Scientific Research on Innovative Areas (No.241451 and No.261552) from the Ministry of Education, Culture, Sports, Science and Technology (MEXT), and a Grant-in-Aid for Scientific Research (C) (No.2454295) from the Japanese Society for the Promotion of Science (JSPS). We would like to thank to Prof. T. Muramatsu who lent us the UV-visible spectrometer and helped us the measurement of an absorbance of the complex, and Prof. T. Gunji who synthesized many samples of tetrakis (isopropyl acetoacetato) zirconium. References [1] M.Mori, Nucl. Inst. and Meth. A, 732 (213) 316. [2] Y. Fukuda, S. Moriyama and I. Ogawa, Nucl. Instr. and Meth. A 732 (213) 397. [3] M.B.Kauer Doctor of Philosophy of UCL (21), J.Argyriades et al. Nucl. Phys. A 847 (21) 168. [4] A.Gando et al. (KamLAND-Zen collaboration), Phys. Rev. Lett.11 (213) 6252 [5] R.Arnold, et al. Nucl. Instr, and Meth. A 563 (24) 79. [6] Mohan Li, Ziyi Guo, Minfang Yeh, Zhe Wang, and Shaomin Chen, arxiv:1511.9339 (215).