Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Similar documents
Test Method: CPSC-CH-E

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

CHEMISTRY DEPARTMENT

TECHNICAL BRODIFACOUM

The analysis of organic acid content of additives, premix, feed, and water.

ICP-OES Application Note Number 35

Chapter 12 Tex-617, Determining Chloride in Concrete

Sodium Chloride - Analytical Standard

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

Nitrate plus Nitrite and Nitrite in Seawater by Segmented Flow Analysis (SFA)

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

SOIL ORGANIC CONTENT USING UV-VIS METHOD

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Examples of Method Validation Studies Conducted in Different Economies

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

4023 Synthesis of cyclopentanone-2-carboxylic acid ethyl ester from adipic acid diethyl ester

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

DISCLAIMER: This method:

SPECIFICATION & TEST PROCEDURE SODIUM SALICYLATE Technical. Molecular weight : Reference : In-house

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

Contact Person : Marie Lawrence APPLICATION

# 12 ph-titration of Strong Acids with Strong Bases

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Spectrophotometric Determination of Ferrocyanide in Effluents

Cadmium and lead content

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

Method NumberUSTUR 150

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

METHOD 3051 MICROWAVE ASSISTED ACID DIGESTION OF SEDIMENTS, SLUDGES, SOILS, AND OILS

Sulfotepp impurities in Chlorpyrifos EC formulations

TEST REPORT. NO.: A001R Date: Dec 27, 2013 Page 1 of 13

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

This protocol is a modified version of the DuBois assay (DuBois et al. 1956) for the quantification of total carbohydrate content of a sample.

National standard of People s Republic of China

Functional Genomics Research Stream. Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions

Total sulphur content

Experiment 24. Chemical recycling of poly(ethylene) terephthalate (PET)

Method NumberUSTUR 100

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

Conductometric Titration & Gravimetric Determination of a Precipitate

Basic Digestion Principles

ICP/MS Multi-Element Standards

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Determination of Isocyanate Equivalent Weight (in toluene solution)

Uncontrolled Copy. SOP Ethylene Glycol Quantitation by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

27th INTERNATIONAL CHEMISTRY OLYMPIAD PRACTICAL EXAMINATION FRIDAY, JULY 14,1995

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

Analysis of domestic sludge using the Agilent 4200 MP-AES

Analytical Procedures for Monitoring Farmbased Anaerobic Digestion (AD) Systems: PROTOCOL III

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Application Determination of isocyanate (NCO-) content

METHANOL REFERENCE SPECIFICATIONS

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

ALLOWAY METHOD OUTLINE

Ascorbic Acid Titration of Vitamin C Tablets

Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

BUREAU OF INDIAN STANDARDS. Draft Indian Standard. SPECIFICATION FOR BASIC CHROMIUM SULPHATE (FOR TANNING) (First revision of IS 6301) ICS:

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

TECHNETIUM-99 IN SOIL

IMPCA METHANOL REFERENCE SPECIFICATIONS

Chlorobenzene from Aniline via the Sandmeyer Reaction. August 21, By ParadoxChem126. Introduction

Standard Operating Procedure for: ph using Oakton ph 5+ Handheld ph Meter. Missouri State University. and

EXPERIMENT 2. Gravimetric Analysis of a Soluble Chloride

STANDARD PROCEDURE: NWSP R2 (15) Polyacrylate Superabsorbent Powders Determination of the Particle Size Distribution by Sieve Fractionation

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

Chapter 9. Volumetric Analysis

(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)

Calibration of Volumetric Glassware. Prepared by Allan Fraser May 2016 APPLICATION Note 1

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

á233ñ ELEMENTAL IMPURITIES PROCEDURES

ANALYSIS CERTIFICATE OF

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Seawater Extraction Procedure for Trace Metals

AOAC Official Method Trace Elements in Waters and Wastewaters

Brooklyn College Department of Chemistry

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Freezing point depression (Item No.: P )

Quantitative analysis of Na, K and Ca in milk and yogurt using the MH-5000 Ultra Compact Elemental Analyzer

Conductimetric Titration and Gravimetric Determination of a Precipitate

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Example method validation and MU approach for Cadmium in seafood test method

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

Transcription:

Book 5 - Laboratory Policies and Procedures C03-1 2009-06-15 1 Scope 1.1 This method describes a general procedure for the determination of leachable arsenic, selenium, cadmium, antimony, and barium in decorative or protective coatings applicable to item 9(c) of Part I, Schedule I of the Hazardous Products Act ( SOR 2005-344 ). 2 Applicable Documents 2.1 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods. Volume 14.02, ASTM E177-90a (1996), pp.79-90. 2.2 Standard Practice for Intra laboratory quality Control Procedures and a Discussion on Reporting Low-Level Data. Volume 11.01, ASTM D4210-89, pp.412-419, 1998. 2.3 John Keenan Taylor, Quality Assurance of Chemical Measurements. Lewis Publishers, INC. 328 pages, 1987. 2.4 National Standard of Canada - Methods of test for toxic trace elements in protective coatings. CGSB Standard Test Method 1-GP-500.2, 1-GP-500.3, 1- GP-500.4, 1-GP-500.5, 1-GP-500.7. Specifications Board. (December, 1973). CGSB Standard Test Method 1-GP-500.2 (December, 1973). 2.5 C. Watson, Update of Method C-03, Determination of Cadmium (Cd), Barium (Ba), Antimony (Sb), Selenium (Se) and Arsenic (As) in Applied Coatings. Product Safety Laboratory, Project Report No. 2004-0801. (Nov. 2004) 2.6 A. Babcock, Update of Method C-03, Determination of Arsenic (As), Selenium (Se), Cadmium (Cd), Antimony (Sb), and Barium (Ba) in Applied Coatings. Product Safety Laboratory, Project Report No. 2005-0881. (Oct. 2007)

Book 5 - Laboratory Policies and Procedures C03-2 2009-06-15 3 Reagents and Apparatus (Note 1) 3.1 ICP-MS Agilent 7500a equipped with an internal standards addition Tee 3.2 Arsenic, Selenium, Cadmium, Antimony and Barium standards, 1000 ppm, or As, Se, Cd, Sb, Ba (+ others) multi-element standard 10.0 ppm ± 0.5%, SCP Science or equivalent, traceable to NIST, for calibration 3.3 10.0 ppb As, Se, Cd, Sb, Ba calibration control standard 3.4 Gallium, Indium and Bismuth standards, 1000 ppm (nominal), SCP Science or equivalent, traceable to NIST, for internal standards 3.5 Ultra-pure (18.2 MS) water, free of As, Se, Cd, Sb, Ba 3.6 Hydrochloric acid, concentrated (- 37% w/w), Trace Metal Grade, Fisher Scientific 3.7 Nitric acid, concentrated (- 69% w/w), Trace Metal Grade, Fisher Scientific 3.8 Scalpel or other suitable scraping tool. 3.9 Tetrahydrofuran (THF) HPLC Grade, Caledon Laboratories, Ltd. 3.10 Electric grinder 3.11 Mortar and pestle 3.12 Air convection oven 3.13 Desiccator 3.14 Sieves, 250 and 500 :m mesh 3.15 Sample bottles for sieved paint 3.16 Analytical Balance, with a precision of 0.1mg 3.17 Weighing vessels 3.18 Glass beakers, 50 ml 3.19 Oscillating hot plate or magnetic stirrer 3.20 Filter paper, Whatman no. 40 3.21 Funnels to fit 50 ml flasks or tubes 3.22 Volumetric flasks, 50 ml, 2 L 3.23 Sample tubes, screw cap, 50 ml certified volume 3.24 Pipettes adjustable 10-100 :L, 100-1000:L, 0.500-2.50 ml, 1.00-10.00 ml 3.25 NIST SRM 1633b, Coal Fly Ash, used as a control Note 1: Equivalent materials and apparatus may be used.

Book 5 - Laboratory Policies and Procedures C03-3 2009-06-15 4 Experimental Procedure 4.1 Scrape off the applied coating from the test sample with a scalpel, or other suitable scraping tool, being careful not to remove any of the underlying substrate material. Alternatively, the coating can be removed with tetrahydrofuran (THF) or a suitable solvent (Note 2), and collected into an appropriate vessel. Evaporate the solvent from the removed coating and dry to constant weight (to the nearest 1 mg) in an air convection oven at 60 C ± 3 C. This may take several hours. Remove the vessel from the oven and cool in a desiccator. 4.2 Transfer the removed coating to a mortar and grind the sample with a pestle. An electric grinder may be used when the sample is too difficult to grind with a pestle and a mortar. Sieve the ground coating with a 500 :m sieve. The sample passing through the 500 :m sieve is then sieved through a 250 :m sieve. The portion of the ground coating that passes the 500 :m and does not pass the 250 :m is used for the leaching test. Place the sieved portion in a weighing vessel and dry to constant weight (to the nearest 1 mg) in an air convection oven at 60 C ± 3 C. This may take about an hour. Remove the vessel from the oven and cool in a desiccator. 4.3 Prepare the 5% (v/v) HCl leaching solution by diluting 50 ml of concentrated (approx. 37% w/w) hydrochloric acid to 1000mL with ultra-pure water. 4.4 Transfer about 100 mg of the dried coating into a tared 100 ml beaker and weigh to the nearest 0.1 mg. Add 20 ml of the 5% (v/v) HCl leaching solution and immediately start stirring for 10 ± 1 minutes at 20 C ±3 C with the use of an oscillating hotplate or a magnetic stirrer. At the end of the 10 ± 1 minutes, immediately filter the solution, through a Whatman no. 40 filter paper in a funnel, into a 50 ml volumetric flask or certified 50 ml sample tube, wash with a few ml of ultra-pure water, add 1 ml of concentrated nitric acid, and make up to volume with ultra-pure water. At least three replicate analyses should be performed on each coating sample. 4.5 Prepare a blank solution by adding 20 ml of the 5% (v/v) HCl leaching solution to a 100 ml beaker and immediately start stirring for 10 ± 1 min. at 20ºC ± 3ºC with the use of an oscillating hotplate or a magnetic stirrer. At the end of the 10 ± 1 min. immediately filter the solution, through a Whatman no. 40 filter paper Note 2: Acetone or dichloromethane may be used to facilitate the removal of the applied coating, solvents like tetrahydrofuran should not be used if the test article's substrate material is a plastic.

Book 5 - Laboratory Policies and Procedures C03-4 2009-06-15 and a funnel, into a 50 ml volumetric flask or certified 50 ml sample tube, wash with a few ml of ultra-pure water, add 1 ml of concentrated nitric acid, and make up to volume with ultra-pure water. 4.6 Prepare a 2.0% (v/v) nitric acid diluting solution by diluting 20 ml of concentrated (approx. 69% w/w) nitric acid to 1000mL with ultra-pure water. 4.7 Dilute the worked-up leachate ten times using 2% (v/v) nitric acid (the 50 ml leachate from section 4.4). 5 Calibration 5.1 Prepare an acid solution consisting of 0.2% (v/v) hydrochloric acid and 2.0% (v/v) nitric acid in a 2 L volumetric flask. Use 4 ml of conc. HCl and 40 ml of conc. HNO 3 and make up to 2 L volume with ultra-pure water. This solution will be used as a blank solution, to prepare calibration standard solutions, and to dilute samples that are over the linear dynamic range of the instrument. 5.2 Prepare a series of at least three working calibration standards in the linear range of the detector of the instrument to obtain a linear calibration curve with a correlation coefficient of at least 0.99. These standards should be in the following range: 0 ppb to 100 or 200 ppb diluted from a 10 ppm solution of the five elements. Make up all calibration standards in 0.2% (v/v) hydrochloric acid and 2.0% (v/v) nitric acid. 5.3 Prepare about 100-250 ml of a 100 ppb solution of the internal standards Ga, In, Ba in 5% nitric acid. This solution is pumped into the internal standard addition Tee (on the back of the peristaltic pump) where it mixes with the sample before going to the spray chamber of the ICP-MS. 5.4 Prepare separately from the standards a 10 ppb multi-element calibration control solution, or buy it ready-made with a NIST traceable certificate of analysis. 5.5 Analyse the calibration standards using a minimum of five replicate readings in the ICP-MS method. Use the same ICP-MS method that will be used for the blanks, controls, and samples. Obtain a calibration curve of ion counts per second vs. concentration and check it for suitability (e.g. outliers & linearity / curve fitting) for each element before proceeding with the analysis of the samples.

Book 5 - Laboratory Policies and Procedures C03-5 2009-06-15 6 Determination 6.1 Analyse the method blank before and after each batch of samples. 6.2 Check the calibration by analysing the 10 ppb multi-element calibration control solution. If the calibration is not in control, it may be necessary to re-make the control solution and / or the calibration standards. 6.3 Analyse the control sample (NIST 1633b - coal fly ash) for all five elements. Record the results in the logbook method control chart (Use CCPro software). 6.4 Analyse the sample solutions using a minimum of five replicate readings in the ICP-MS method. The use of nine or more replicate readings gives better statistics, but results in slightly longer analysis times. If necessary, dilute the sample with 0.2% HCl and 2.0% HNO 3 (as prepared in 5.1) to keep the results within the range of the calibration. 7 Calculations and Reporting 7.1 Calculate the percentage by weight of leachable elements in the dry coating test sample according to the following equation: where: elements = Ci 50 10 Df m 10,000,000 Ci = Concentration of element in the leaching solution (ppb) from the instrument 6.4 50 = Volume of worked-up leachate (filtered, rinsed, acidified) 4.5 10 = Dilution of leachate 4.7 Df = Further Dilution factor (if required to stay within calibration) 6.4 m = mass (g) of test sample used 4.4 10,000,000 = ppb / percent 7.2 Where the quantity of sample for testing is sufficient and where practicable, the result of analysis shall be reported as the average of a minimum of three independent replicate determinations having a precision which should not differ more than the specifications defined in section 8.

Book 5 - Laboratory Policies and Procedures C03-6 2009-06-15 7.3 Where applicable, the average (x.x 10 +e ) and the sample standard deviation (s.s 10 e ) of replicate determinations (s for n > 2) shall be calculated (Note 3), and the result of analysis reported in the following format: Sample No. Specimen No. Colour / Description [As] [Se] [Cd] [Sb] [Ba] S-1001234 1A red paint (x.x±2s.s) 10 +e (x.x±2s.s) 10 +e (x.x±2s.s) 10 +e (x.x±2s.s) 10 +e (x.x±2s.s) 10 +e S-1001234 2A blue paint (x.x±2s.s) 10 +e (x.x±2s.s) 10 +e (x.x±2s.s) 10 +e (x.x±2s.s) 10 +e (x.x±2s.s) 10 +e 8 Quality Control Procedure 8.1 To ensure the proper operation of the instrument and that the precision of the analytical measurements meet the specifications of the method, the following quality control procedures shall be conducted concurrently with the analysis of the test sample. 8.2 The normal and correct operation of the ICP-MS shall be verified according to the following guidelines: 8.2.1 Run the ICP-MS Tune program and verify that the values (ion counts per second) for the tuning solution elements (typically Li Y Tl) are within acceptable limits of the historical values. A slow decline in the numbers is to be expected as the detector wears out over a period of about two years. Record the tuning element values in the ICP-MS logbook and include a copy of the tune program printout in the sample or report file. If the tuning values are too low, re-tune the instrument to get acceptable values. Minimum acceptable values are Li 6400, Y 16000, Tl 9600. Note 3: The standard deviation (s) of the test results may be calculated according to the following equation, where x i is the result of an individual determination, 0 is the average of the replicate determinations, and n is the total number of replicates. s = ' (x i! 0) 2. r (n!1)

Book 5 - Laboratory Policies and Procedures C03-7 2009-06-15 8.3 The normal and correct operation of the test method shall be verified according to the following guidelines: 8.3.1 Conduct an analysis of the leachate of NIST SRM 1633b, coal fly ash, tested under identical experimental conditions (except for grinding and sieving) to those of the coating sample. Record the analytical test results for all of the elements in the ICP-MS QC logbook. Verify that the results are within acceptable limits on the control chart, and if so, enter a note in the sample folder(s) to the effect that the test method was found to be "within control". If the test results of the control sample fall outside the specifications of the method, the entire analytical procedure shall be repeated. 9 Precision and Bias 9.1 Repeatability (r): The deviation between replicate test results, as obtained from analysis of NIST 1633b (coal fly ash) by the same analyst using the same instrument under constant operating conditions, in the normal and correct operation of the test method, should not differ by more than the following repeatability limit at a 95% probability level (1.960 %2 CV% = 2.772 CV%). As: 11% Se: 100% Cd: n/a Sb: n/a Ba: 50% 9.2 Bias: The bias cannot be established due to the absence of an accepted leachable reference value in paint. 10 Limit of Detection 10.1 The limit of detection (LOD) of this method, as determined by ICP-MS has been calculated (Note 4) to be: Arsenic: 0.00018 Selenium: 0.00015 Cadmium: 0.00019 Antimony: 0.00043 Barium: 0.00041 Note 4: ASTM test method D4210.

Book 5 - Laboratory Policies and Procedures C03-8 2009-06-15 11 Limit of Quantitation 10.1 The limit of quantitation (LOQ) of this method, as determined by ICP-MS has been calculated (Note 5) to be : Arsenic: 0.00055 Selenium: 0.00047 Cadmium: 0.00059 Antimony: 0.0013 Barium: 0.0012.............................. End............................. Note 5: ASTM test method D4210

Book 5 - Laboratory Policies and Procedures C03-9 2009-06-15 L:\QualityAssurance\Quality\BOOK5\ENGLISH\Amendment 70\C03 Effective 2009-06-15.wpd