GEANT4 Simulations of. the LAXPC Performance. H. M. Antia. Tata Institute of Fundamental Research

Similar documents
X-ray burst science with Astrosat

Large Area X-ray Propor.onal Counter (LAXPC) instrument and ini.al science results (from payload verifica.on phase)

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

Development of a 3D-Imaging Calorimeter in LaBr 3 for Gamma-Ray Space Astronomy

Proportional Counters

Presentation by Indian Delegation. to 49 th STSC UNCOPUOS. February 2012 Vienna

A NEW GENERATION OF GAMMA-RAY TELESCOPE

The simulation of the Electron Tracking Compton Camera with a gaseous time projection chamber and a scintillator

X-ray Observations of Jet Sources Using Astrosat. A R Rao Tata Institute of Fundamental Research, India

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

Design optimisation of X-ray detectors for SSM

Summer Student Project Report

IBIS - IN FLIGHT CALIBRATION ACTIVITIES

BUREAU INTERNATIONAL DES POIDS ET MESURES

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Performance of the Gamma-ray Imaging Detector with Micro-TPC

1. Motivation & Detector concept 2. Performance 3. Confirmation experiments 4. Summary

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Calibration of A Small Anode Germanium Well Detector

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

9.1 Years of All-Sky Hard X-ray Monitoring with BATSE

Gamma-Ray Polarimetry in the Pair Production Regime

arxiv:astro-ph/ v2 4 Dec 2002

Precise Measurement of the Absolute Yield of Fluorescence Photons in Atmospheric Gases

arxiv:physics/ v1 3 Aug 2006

Light Dark Matter and XENON100. For the XENON100 Collaboration Rafael F. Lang Columbia University

INTEGRAL. Science Operations Centre. Announcement of Opportunity for Observing Proposals (AO-11) JEM-X Observer s Manual

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

INTEGRAL. Science Operations Centre. Announcement of Opportunity for Observing Proposals (AO-8) JEM-X Observer s Manual

Transition Radiation Detector for GlueX

Motivation Electron-Tracking Compton Telescope 1 st Flight of SMILE Preparation for next step summary

In Orbit Operation of LAXPC Payload: Concerns and Care. R. K. Manchanda Department of Physics Mumbai University

Compton suppression spectrometry

A novel design of the MeV gamma-ray imaging detector with Micro-TPC

X-ray ionization yields and energy spectra in liquid argon

A. Takada (Kyoto Univ.)

Background Modeling and Materials Screening for the LUX and LZ Detectors. David Malling Brown University LUX Collaboration AARM Meeting February 2011

Detecting high energy photons. Interactions of photons with matter Properties of detectors (with examples)

LOW ENERGY SOLAR NEUTRINOS WITH BOREXINO. Lea Di Noto on behalf of the Borexino collaboration

Transition Radiation Detector for GlueX

Experiment of the 30 cm-cube ETCC under the Intense Radiations with Proton Beam

LAB 4: Gamma-ray coincidence spectrometry (2018)

The Compton Spectrometer and Imager A balloon- borne gamma- ray spectrometer, polarimeter, and imager

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

A very wide field focusing telescope for Synoptic studies in the soft X-ray band

X ray Imaging Android [XIA]

arxiv: v1 [physics.ins-det] 3 Feb 2011

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Advances in the Micro-Hole & Strip Plate gaseous detector

PERFORMANCE OF A ROOM TEMPERATURE GAS PROPORTIONAL SCINTILLATION COUNTER IN X-RAY ANALYSIS OF METALLIC ALLOYS EXCITED WITH ALPHA PARTICLES

Calibration of the AGILE Gamma Ray Imaging Detector

GEM-based photon detector for RICH applications

CRaTER Science Requirements

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Mass of the electron m 0

Polarimeter for Small Satellite Design, Feasibility Study, and Ground Experiments + Balloon Experiment

THE COMPTON EFFECT Last Revised: January 5, 2007

Determination of the activity of radionuclides

Reactor On/Off Monitoring with a Prototype of Plastic Anti-neutrino Detector Array (PANDA)

Effect of the time characteristics of the Compton camera on its performance

High pressure xenon gas detector with segmented electroluminescence readout for 0nbb search

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

He-3 Neutron Detectors

Monitor of All Sky X Ray X (MAXI) on the International Space Station

Reduction procedure of long-slit optical spectra. Astrophysical observatory of Asiago

Performance study of the ceramic THGEM *

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

arxiv: v1 [astro-ph] 26 Feb 2008

Gamma and X-Ray Detection

R&D on Astroparticles Detectors. (Activity on CSN )

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Development of a new MeV gamma-ray camera

LARGE UNDERGROUND XENON

Balloon-borne experiment for observation of sub-mev/mev gamma-rays from Crab Nebula using an Electron Tracking Compton Camera

Environmental Applications

BEGe Detector studies update

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Detekce a spektrometrie neutronů. neutron detection and spectroscopy

Studies of Hadron Calorimeter

ON THE OMNIPRESENT BACKGROUND GAMMA RADIATION OF THE CONTINUOUS SPECTRUM

Quality Assurance. Purity control. Polycrystalline Ingots

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

BETA-RAY SPECTROMETER

ANAIS: Status and prospects

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Arjan Plompen. Measurements of sodium inelastic scattering and deuterium elastic scattering

DARK MATTER SEARCH AT BOULBY MINE

Calibration of the IXPE Instrument

The HEX Anti-Coincidence Detector

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

Large-Area Balloon-Borne Polarized Gamma Ray Observer (PoGO)

Results from EXO 200. Journal of Physics: Conference Series. Related content PAPER OPEN ACCESS

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

VERITAS Design. Vladimir Vassiliev Whipple Observatory Harvard-Smithsonian CfA

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

COLUMNAR RECOMBINATION JIN LI INSTITUTE FOR BASIC SCIENCE CYGNUS2015 CONFERENCE JUN.3, 2015

Transcription:

GEANT4 Simulations of the LAXPC Performance H. M. Antia Tata Institute of Fundamental Research

GEANT4 simulations of LAXPC detector were used to estimate Efficiency of background rejection Efficiency and field of view of detector Resolution and channel No. as a function of energy by fitting observed spectra for radioactive sources Response matrix of the detector

LAXPC payload consists of 3 large area X-ray proportional counters Detector size: 100 39 16.5 cm filled with a mixture of Xenon (90%) and Methane (10%) at a pressure of 2 atmospheres. Top of the detector is covered by a 50 µm thick Mylar window Above the Mylar window there is a window support collimator of height 7.5 cm and the field of view collimator of height 37 cm. These collimators have mesh with a pitch of 7 mm. Simulations use a volume of 120 60 80 cm enclosing the entire detector.

Main Anodes : A1 A7 in 5 layers Veto Anodes : A8, A9, A10 on 3 sides No Veto Anodes on two small sides (39 16.5 cm) Mylar and collimator on the top side

GEANT4 simulation of 10 6 photons with fixed energy. For Cd 109 energies of 22.1 kev (54.5%), 21.9 kev (28.8%), 24.9 kev (16.7%) Initial Photon trajectory is normal to detector top (except for FOV part) Uniformly distributed over detector area. Simulations with and without the collimators (and shield) are done. Collimator is required for FOV, effective area and background calculations. For background simulation the flux is assumed to be uniform and isotropic.

To reject background events the following logic is implemented which is consistent with the processing electronics: Any event that is recorded in veto-anodes (A8 A10) Any event that deposits more than an upper limit (80 kev) in any anode Any event that is recorded in more than 2 main anodes (A1 A7) If an event is recorded in two main anodes, then it is accepted only if at least one of the energy is in K-threshold for Xe (30±4.5 kev). If the event is accepted the energies in two anodes are added and it is recorded as a single event of combined energy.

Calibration of the Field of View 15 kev: FWHM = 43 = 0.72 50 kev: FWHM = 47 = 0.78

Detector Efficiency and Effective Area

Simulation of background 10 6 particles uniformly distributed over entire surface area 120 60 80 cm and in 2π solid angle about 233333±1177 particle reach active detector volume 100 39 16.5 cm Following factors contribute to background rejection 1. The Shield 2. The Detector efficiency 3. Coincidence 4. Veto layers 5. Energy deposited > 80 kev Simulation were done with and without veto-anode A10 as in LX10 detector A10 has been disabled.

Background from cosmic diffuse X-ray background dn de = 87.4 E 2.3 cm 2 s 1 kev 1 steradian 1 gives background 165 s 1 in 1 detector

A10 enabled : 146 s 1, A10 disabled : 156 s 1

Detector Response for Radioactive Sources Three radioactive sources Fe 55, Cd 109, Am 241 were used for calibration. For each source, energy deposited in each cell (60 main anodes and 3 veto anodes) during each event is recorded. To account for finite resolution, a random number with Normal distribution with 0 mean and σ = E p σ i is added.

Effective energy in all cells in an anode are added. For LX10: For C1, 0.95E p is used for C12, 1.05E p is used. For A4 C1, 0.74E p was used. A10 is disabled. For LX20, LX30: For C1 and C12, 0.95E p is used Rejection and K-escape logic as used in PE is applied and total energy in each anode is converted to channel No. n c = e 1 E p (1 + e 2 E p )

The simulated spectrum is compared with observed spectrum after subtracting the background. For normalisation the simulated spectrum is multiplied by a constant to match the total counts under one peak. To adjust the density of gas the square of relative difference in total counts for each anode layer for Cd 107 is minimised 5 ( ) 2 Oi S i i=1 This corrects for difference in temperature or pressure O i

Since the peak position in simulation may not exactly match that in observed spectra for each anode, while comparing a small shift by a few channels in simulated spectra is made to get best match. Parameters to be determined : e 1, e 2, σ 1, σ 2, σ 3, σ 4 e 1 is kept fixed at about 9.0 e 2, σ 3, σ 4 are determined by best fit to Am 241 spectrum σ 1, σ 2 are determined by best fit to Fe 55 and Cd 109 respectively, keeping e 2 fixed. Finally the channel to energy mapping is determined by fitting n c = e 0 + e 1 E p (1 + e 2 E p ) Here, only e 0, e 1 are fitted as e 2 is determined earlier. The resolution as a function of energy is determined by fitting a linear spline with 3 knots to σ 2 (E 1 )

LX20 Detector

LX30 Detector

To calculate detector response for other energies we need to get σ(e, T ), n c (E, T )

For Crab X-ray source, the simulated spectrum calculated when the input spectrum of N(E) = N 0 E 2.1 The expected count rate is about 6000 s 1 in each detector. At this rate the dead-time of the system will reduce the count rate by about 25%. Net count is expected to be about 13000 s 1. For 1 mcrab source in 100 s the detection is at level of 8σ in total counts. If counts in 3 20 kev are used it improves to 16σ. is shown in Fig.

OJ 287 α = 1.65 Counts: 0.6 s 1, 3.7σ detection in 1000 s (3 20 kev)

Summary Field of view: 43 at 15 kev, 47 at 50 kev Effective area: 0.8 m 2 at 10 20 kev, 0.4 m 2 at 80 kev For LX30 in lab background increased by 10% when A10 was disabled Once particle flux in ASTROSAT orbit is available the effect of A10 on background will be estimated Simulated spectra for all 3 radioactive sources match the observed spectra Using the resolution and channel number as a function of energy the detector response matrix has been generated. For Crab source about 6000 s 1 is expected in each detector. 1mCrab source can be detected with 100 s observation.