EXPERIMENTAL VALIDATION OF RE-CENTRING CAPABILITY EVALUATION BASED ON ENERGY CONCEPTS

Similar documents
SEISMIC BASE ISOLATION

Seismic design of bridges

Boundary Nonlinear Dynamic Analysis

International Journal of Advance Engineering and Research Development

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS

Improving the earthquake performance of bridges using seismic isolation

Numerical Assessment of the Seismic Performance of Sliding Pendulum Isolators

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

A Sloping Surface Roller Bearing and its lateral Stiffness Measurement

Preliminary Examination in Dynamics

THE PENNSYLVANIA STATE UNIVERSITY SCHREYER HONORS COLLEGE SCHOOL OF ENGINEERING

Preliminary Examination - Dynamics

COLUMN INTERACTION EFFECT ON PUSH OVER 3D ANALYSIS OF IRREGULAR STRUCTURES

Experimental Investigation of the Performances of a WRS-BTU Seismic Isolator

Effect of Dampers on Seismic Demand of Short Period Structures

CAPACITY SPECTRUM FOR STRUCTURES ASYMMETRIC IN PLAN

Displacement ductility demand and strength reduction factors for rocking structures

INVESTIGATION OF JACOBSEN'S EQUIVALENT VISCOUS DAMPING APPROACH AS APPLIED TO DISPLACEMENT-BASED SEISMIC DESIGN

Influence of the Plastic Hinges Non-Linear Behavior on Bridges Seismic Response

Wire rope springs for passive vibration control of a light steel structure

NON-LINEAR VISCOELASTIC MODEL OF STRUCTURAL POUNDING

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

Pushover Seismic Analysis of Bridge Structures

Harmonized European standards for construction in Egypt

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

VIBRATION ANALYSIS OF E-GLASS FIBRE RESIN MONO LEAF SPRING USED IN LMV

Introduction to structural dynamics

PROTECTING PRECISION MACHINERY USING GUIDEWAY SLIDING ISOLATOR WITH GAP SPRING AND DAMPERS

Behaviour of the double concave Friction Pendulum bearing

Hand Calculations of Rubber Bearing Seismic Izolation System for Irregular Buildings in Plane

STRUCTURAL DYNAMICS BASICS:

VELOCITY EFFECTS ON THE BEHAVIOUR OF ASYMMETRICAL FRICTION CONNECTIONS (AFC)

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

Introduction to Mechanical Vibration

midas Civil Dynamic Analysis

NUMERICAL MODELLING OF STORAGE RACKS SUBJECTED TO EARTHQUAKE

SHAKING TABLE TEST FOR FRICTIONAL ISOLATED BRIDGES AND TRIBOLOGICAL NUMERICAL MODEL OF FRICTIONAL ISOLATOR

Analysis Of Seismic Performance Of Fps Base Isolated Structures Subjected To Near Fault Events

Design of Earthquake-Resistant Structures

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

Analytical Predictive Models for Lead-Core and Elastomeric Bearing

1338. Experimental and numerical studies on multi-spherical sliding friction isolation bearing

Model tests and FE-modelling of dynamic soil-structure interaction

DEVELOPMENT OF A LARGE SCALE HYBRID SHAKE TABLE AND APPLICATION TO TESTING A FRICTION SLIDER ISOLATED SYSTEM

Damping from bearing hysteresis in railway bridges

Structural Dynamics Lecture 4. Outline of Lecture 4. Multi-Degree-of-Freedom Systems. Formulation of Equations of Motions. Undamped Eigenvibrations.

CE6701 STRUCTURAL DYNAMICS AND EARTHQUAKE ENGINEERING QUESTION BANK UNIT I THEORY OF VIBRATIONS PART A

Dynamics of structures

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

AN INNOVATIVE ELASTO-PLASTIC ENERGY DISSIPATOR FOR THE STRUCTURAL AND NON-STRUCTURAL BUILDING PROTECTION

Finite Element Modelling with Plastic Hinges

Collapse modes of structures under strong motions of earthquake

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

IMPORTANT FEATURES OF THE RESPONSE OF INELASTIC STRUCTURES TO NEAR-FIELD GROUND MOTION

ENG1001 Engineering Design 1

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems

Damping of materials and members in structures

The student will experimentally determine the parameters to represent the behavior of a damped oscillatory system of one degree of freedom.

Effective Stiffness and Period of Friction Bearing Devices with one Concave Sliding Surface for Different Load Conditions

SEISMIC RESPONSE OF STRENGTH AND STIFFNESS DEGRADING SINGLE DEGREE OF FREEDOM SYSTEMS

Development of Spherical Sliding Bearing

Influence of column web stiffening on the seismic behaviour of beam-tocolumn

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION

SHAKING TABLE DEMONSTRATION OF DYNAMIC RESPONSE OF BASE-ISOLATED BUILDINGS ***** Instructor Manual *****

EUROCODE EN SEISMIC DESIGN OF BRIDGES

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS

SEISMIC RESPONSE EVALUATION OF AN RC BEARING WALL BY DISPLACEMENT-BASED APPROACH

Cyclic behaviour of a reinforced concrete braced frame with high damping rubber devices

DETERMINATION OF PERFORMANCE POINT IN CAPACITY SPECTRUM METHOD

Multi Linear Elastic and Plastic Link in SAP2000


Junya Yazawa 1 Seiya Shimada 2 and Takumi Ito 3 ABSTRACT 1. INTRODUCTION

ENERGY DIAGRAM w/ HYSTERETIC

HIGHLY ADAPTABLE RUBBER ISOLATION SYSTEMS

Chapter 11: Elasticity and Periodic Motion

Difference Between Fixed and Floating Reference Points AASHTO T-321

Dynamics of Ocean Structures Prof. Dr. Srinivasan Chandrasekaran Department of Ocean Engineering Indian Institute of Technology, Madras

Objectives: After completion of this module, you should be able to:

ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR

BI-DIRECTIONAL SEISMIC ANALYSIS AND DESIGN OF BRIDGE STEEL TRUSS PIERS ALLOWING A CONTROLLED ROCKING RESPONSE

NUMERICAL SIMULATION OF THE INELASTIC SEISMIC RESPONSE OF RC STRUCTURES WITH ENERGY DISSIPATORS

Influence of Vertical Ground Shaking on Design of Bridges Isolated with Friction Pendulum Bearings. PI: Keri Ryan GSR: Rushil Mojidra

DUCTILITY BEHAVIOR OF A STEEL PLATE SHEAR WALL BY EXPLICIT DYNAMIC ANALYZING

Experimental and Analytical Study of the XY-Friction Pendulum (XY-FP) Bearing for Bridge Applications

Response of Elastic and Inelastic Structures with Damping Systems to Near-Field and Soft-Soil Ground Motions

IN SITU TESTING TECHNOLOGY FOR FOUNDATION & EARTHQUAKE ENGINEERING. Wesley Spang, Ph.D., P.E. AGRA Earth & Environmental, Inc.

ENERGY BALANCE BASED SEISMIC DESIGN METHOD OF RC STRUCTURES CONSIDERING CYCLIC BEHAVIOR UNDER EARTHQUAKE

Strength Degradation in Lead-Rubber Bearings during a Long-duration Earthquake

Nonlinear static analysis PUSHOVER

Title. Author(s)DONG, Q.; OKAZAKI, T.; MIDORIKAWA, M.; RYAN, K.; SAT. Issue Date Doc URL. Type. Note. File Information BEARINGS

Bracing for Earthquake Resistant Design

ESTIMATION OF INPUT SEISMIC ENERGY BY MEANS OF A NEW DEFINITION OF STRONG MOTION DURATION

Aseismic design of structure equipment systems using variable frequency pendulum isolator

Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings.

SIMPLIFIED METHODS FOR SEISMIC RELIABILITY ANALYSIS

PARAMETERS CHARACTERIZING THE SEISMIC DEMAND FOR EARTHQUAKE DAMAGE SCENARIO EVALUATION

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Single-Degree-of-Freedom Analytical Predictive Models for Lead-Core Bearing Devices

Transcription:

ABSTRACT : EXPERIMENTAL VALIDATION OF RE-CENTRING CAPABILITY EVALUATION BASED ON ENERGY CONCEPTS Renzo MEDEOT Chairman of CEN TC 340: Anti-seismic Devices Seismic Engineering Consultant E-mail: medeot@iol.it Present Norms do not furnish an acceptable approach of general validity to evaluate the re-centring capability of seismic isolation systems and none of them is based upon solid theoretical fundamentals, but rather, make reference to empirical approaches. This author developed a theoretical approach to this problem, suggesting an energy-based criterion for its quantification, that also incorporates praiseworthy simplicity. It just involves the comparison of two calculable and measurable physical magnitudes, namely the elastically (or, better said, reversibly) stored and the irreversibly dissipated earthquake energy input. The newly proposed criterion was accepted for an oral presentation at the 13th World Conference (Vancouver, 2004) and since then gained an increasing consensus among the technical and scientific community. The validity of the new criterion has been confirmed by the results of several hundreds of step-by-step non-linear analyses conducted on real cases, as well as by a degree thesis at the University of Padua (Italy). Its experimental validation occurred only recently within the framework of the LESSLOSS Research Project funded by the European Commission, which lasted three years (2004-2007). Over 200 trials were conducted in two distinct testing campaigns at the shake-table facility of ENEA Casaccia near Rome. The results have fully substantiated the method for evaluating the re-centring capability of seismic isolated systems based on the energy approach. The scope of this paper is that of illustrating the testing program and reporting in detail the results thereof, as well as commenting on the blatant discrepancies with the criteria adopted in some international Norms. KEYWORDS: Seismic Isolation, Re-centring Capability, Restoring Capability 1. INTRODUCTION In 2003 this author developed a theoretical approach to the evaluation of the re-centring capability of seismic isolation systems, suggesting an energy-based criterion for its quantification, that also incorporates praiseworthy simplicity. The newly proposed criterion was accepted for an oral presentation at the 13th World Conference (Vancouver, 2004) and since then gained an increasing consensus among the technical and scientific community. To better understand this paper it is opportune to summarize the fundamentals of the new criterion, with the conclusions achieved for the main types of existing isolators, in particular for flat surface sliders coupled with steel hysteretic elements, which were used in the experimental testing campaign. It is known that the four fundamental functions of a seismic isolation system are the following: i) Transmission of vertical loads; ii) Lateral flexibility on the horizontal plane; iii) Dissipation of substantial quantities of energy and iv) Re-centring capability It should be noted that Energy dissipation and Re-centring capability are two antithetic functions and their relative importance depends primarily on the case under examination. Let s consider the energy balance equation in the following form valid for structures E i = E S + E H + E V (1) where: Ei represents the mechanical energy transmitted to the structure by the seismic ground motion its foundations. E S is the reversibly stored energy (elastic strain energy, potential energy and kinetic energy) E H is the energy dissipated by hysteretic deformation is the energy dissipated by viscous damping E V through

According to the Energy approach, the criterion to establish the re-centring capability of a seismic isolation system is based upon a comparison between the energy stored by the system in a reversible form E S (elastic, potential etc.) and that hysteretically dissipated E H. The energy dissipated by viscous damping does not participate in the re-centring process. Re-centring capability is quantified through a comparison between the first two terms of the second member of equation (1) For deformations from 0 up to the design displacement d d, one has to check that the reversibly stored energy E S is greater than a given portion of the energy dissipated by hysteretic deformation E H, that is to say: E S λ E H (2) The results of numberless step-by-step non-linear analyses, as well as the experimental results of the testing campaigns conducted at the shake table rig at ENEA-Casaccia, demonstrated that a seismic isolation system possesses sufficient re-centring capability when: E S 0,25 E H (3) The above criterion has proven to be valid and applicable to all types of existing isolation devices, as well as construction typologies. The requirement (3) can be translated into formulae or design criteria for each type of isolator. For example, for Lead Rubber Bearings expression (3) is satisfied for: (4) where: A Pb the cross-sectional area of the lead core; G is the rubber shear modulus; γ d is the design shear strain and A r the cross-sectional area of the rubber bearing. For Friction Pendulum expression (3) is satisfied for: μ d R d (5) 2 where: d d is the design displacement; R is the radius of curvature of the spherical surface and μ is the dynamic coefficient of friction. Finally, let s consider the case of flat surface slider equipped with steel hysteretic elements as energy dissipaters, which was the type of isolator used in the testing campaign at ENEA Casaccia. To evaluate both the reversibly stored energy E S and the energy dissipated by hysteretic deformation E H we resort to the model represented in Figure 1 below. k 2 F k 1 sliding element with frictional force F f Figure 1: Model having the same characteristic bi-linear curve of a hysteretic system

The criteria for equivalence are given by the following expressions: k e = k 1 + k 2 k p = k 2 (6) F f = k 1 d e With reference to the Figure 2 on next page, expression (3) is satisfied for: m 3 η (7) 2 2 m + m 3 where: η is the ratio between the post-elastic and the elastic stiffness of the hysteretic element (i.e. k p = η k e ) m is the ductility factor (i.e. d d = m d e ). Unlike the preceding two types of isolators, in the case of flat surface sliders equipped with steel hysteretic elements, the re-centring capability is governed by two dimensionless parameters only. F k p = η k e F y k e Figure2: Characteristic bi-linear curve of a hysteretic system Equation (6) is graphically represented in Figure 3 below. d e d d =m d e d η 0,045 0,04 0,035 Area with re-centring capability 0,03 0,025 0,02 0,015 0,01 Area without re-centring capability 0,005 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 m Figure 3: Graphical representation of the Re-centring capability evaluation according to the Energy Approach

2. THE TESTING PROGRAMME The steel hysteretic elements were of the Triangular Plate Damper type, which was selected for its ease in both dimensioning and construction but especially so because it is not subjected to any limitations patent-wise. Several types of steel hysteretic elements were designed and manufactured, so as to cover the range of interest of both dimensionless parameters η (from 0,024 to 0,071) and m (from 1 to 13) that govern the behaviour of this type of devices. All the steel hysteretic elements were subjected to the characterization tests at the Bundeswehr University in Munich during the month of December 2006. For each type of device the testing procedure at the shaking table of ENEA-Casaccia was the following: 1) Subject the specimen to a harmonic sweep input in the range of frequency of expected resonance 2) Subject the specimen to progressively increasing seismic inputs, so as to obtain displacement time-histories with different values of ductility factor m. Tests Nr. 1) were conducted at relatively low acceleration input, so as to keep the isolated system within the elastic limits. After having determined the natural frequency f 0 of the isolated system, the elastic stiffness was evaluated through the expression: K e = (2π f 0 )2 M (8) where M is the isolated mass. These test were also conducted to remedy for possible hidden springs in the testing rig. It must be observed that the precise determination of f 0 gave some problems, in that apparently there were two distinct peaks in the diagram oscillation amplitude vs frequency. The only possible explanation for the above is the existence of two distinct values K 1 and K 2 of stiffness in the two direction. In this case, the correct value of the elastic stiffness K e is given by the following expression: K e = K 1 K 2 (9) Once determined the actual value of the elastic stiffness, the characteristic curves of each type of hysteretic devices obtained from the tests at Bundeswehr University in Munich were corrected. In this manner the actual values η and d e (see e.g. Figure 4) were established. Figure 4: Five Hysteretic loops of Element # 17 and graphical evaluation of post-elastic stiffness K p and elastic displacement d e

It should be noted that the precise evaluation of the elastic displacement d e is necessary to calculate the ductility factor m through the expression: d d m = (10) d e The seismic inputs were: - various natural records, such as the Alkion, Bolu Mountain, Colfiorito, to name a few. - a synthetic accelerogramme expressly prepared by Dr. Dario Rinaldis from ENEA, named BCE ; Each device, which is characterized by a specific stiffness ratio η, was subjected to progressively raising seismic inputs (in terms of peak ground acceleration), which produced increasing maximum displacements. If we interpret the latter as the maximum design displacement d d for that specific test and calculate the relevant ductility factor m by means of expression (10), in the diagram η vs m of Figure 3 we will identify one precise point which univocally represents that test. The mock up was a SDOF isolation system comprising: - a steel frame ; - Nr.4 MSM sliding spherical bearings (MSM is a special sliding material developed by Maurer Söhne); - one (1) to three (3) steel hysteretic element(s), and - a rigid reaction mass Two distinct masses were used, equal to 12,2 and 16,4 t respectively. The testing rig (see Figure 5 below) is completed with four guides that restrain the movement in one direction only, as well as other safety accessories that prevent the frame and the supported mass from running off the MSM sliding bearings in case the steel hysteretic element should break away (something that actually never occurred during the testing campaign). Figure 4: Testing rig for flat PTFE sliding bearings equipped with steel hysteretic elements. Reaction mass equal to 12,2 t

3. ANALYSIS OF EXPERIMENTAL DATA During the testing campaign a formidable mass of data was gathered, with a total of over 200 runs executed, with 14 measure channels active. The management and elaboration required considerable work from all who, through different tasks, participated in the execution of the tests. The results were then used in quite different ways, depending on the intended objective. For example ENEA in the Deliverable 39: Numerical analysis of the Steel Hysteretic Devices used the data for studies on mathematical modelling of the devices, while Maurer Söhne verified the repeatability of the results from distinct specimens of the same type of device, their reliability, fatigue resistance etc. A word on this last characteristic of Steel Hysteretic Devices: it should be observed that no specimen has shown signs of failure, such as the appearance of draws, even though they were subjected to levels of strain superior to those foreseen by design, and for an elevated number of cycles. Here below the results of the elaborations oriented toward experimental testing of the re-centring capability evaluation according to the energy approach are reported. Due to space restraint, only the data relevant to a significative case are presented, precisely those of the steel hysteretic element #7. This element has a stiffness ratio centred in an interesting area of the diagram η vs m in Figure 3. In fact, in this area (0,03 < η < 0,04) the re-centring evaluation criterion based on energy concepts predicts the existence of a zone with low values for m, having adequate restoring capability, followed by a zone lacking this property for intermediate values of m, to then return to a zone with adequate restoring capability for high values of m. This is precisely what has been observed during the tests, as proven by the results listed in Table 1 below. Table 1: Experimental results of the shake table tests on Element # 07 Run PGA # [g] d d d res [mm] [mm] 100 0,30 6,5 0,4 0,9 0,07 101 0,40 10,5 1,6 1,4 0,15 102 0,50 25,7 9,8 3,4 0,38 103 0,55 36,5 18,9 4,8 0,52 104 0,60 45,1 25,6 5,9 0,57 105 0,70 60,1 33,9 7,9 0,56 106 0,80 75,2 40,7 9,9 0,54 107 0,90 90,5 46,1 11,9 0,51 108 0,95 96,6 44,4 12,7 0,46 109 1,00 102,2 44,0 13,5 0,43 m d d res d The red coloured numbers represent the cases in which the condition of adequate restoring capability suggested by Professor Mauro Dolce is not verified, that is to say: d res 0,5 d d (11) where d res is the residual displacement.

4. GRAPHICAL REPRESENTATION OF THE RESULTS As it has been already stated, each test is characterized by a pair of dimensionless parameters η, m and thus can be represented by a dot in the diagram of Figure 3, which univocally represents that test. The individual displacement time-histories were divided up into two classes, i.e. those endowed with restoring capability and those which are not, according to a criterion (11) suggested by Prof. Mauro Dolce (residual displacement lesser than 0,5 times the design displacement. Figure 5 here below a shows typical displacement time-history recorded during the testing campaign at ENEA. Figure 5: Displacement time-history for the test with Element #07 subjected to a BCE synthetic seismic input Figure 6 the is a graphical representation of the results achieved during the test campaign carried out at ENEA Casaccia shake table. The green coloured dots represent the cases (displacement time-histories) in which the condition of adequate restoring capability suggested by Professor Dolce is satisfied, while the red colour dots represent those cases where the same is not verified. Figure 6: Graphical representation e of the results achieved during the test campaign carried out at ENEA Casaccia shake table and comparison with the Energy approach restoring requirement.

Figure 6 does not show the results relating to cases with η > 0,04, which turned out to be all represented by green coloured dots. As we can observe, there is a very good agreement between the re-centring evaluation method of seismic isolation systems based on energy concepts and the experimental results of the testing campaign carried out at the shake table of ENEA Casaccia. CONCLUSIONS The re-centring evaluation method based on energy concepts incorporates praiseworthy simplicity, in that it just involves the comparison of two calculable and measurable physical magnitudes, namely the reversibly stored and the irreversibly dissipated earthquake energy input. The validity of the new criterion has been confirmed by the results of several hundreds of step-by-step non-linear analyses conducted on real cases, as well as by a degree thesis at the University of Padua (Italy). Its experimental validation occurred only recently within the framework of the LESSLOSS Research Project funded by the European Commission, which lasted three years (2004-2007). The experimental results have fully substantiated this new method and at the same time disproved the criteria adopted for evaluating the re-centring capability included in some international Norms The re-centring evaluation method based on energy concepts has been adopted in the European Norm EN15129: Anti-seismic Devices which will be published in the early months of 2009. REFERENCES Uang, C. M., (1988) Use of Energy as a Design Criterion in Earthquake-resistant Design, UCB/ERC-88/18, University of California at Berkeley USA AASHTO (2001) - Guide Specification for Seismic Isolation Design, American Association of State Highways and Transportation Officials, Washington D.C, USA Medeot R., (2004) Re-Centring Capability Evaluation of Seismic Isolation Systems Based on Energy Concepts, 13th World Conference on Earthquake Engineering, - Vancouver, B.C., Canada EN1998-2 (2005): Design of structures for earthquake resistance - Part 2: Bridges, European Committee for Standardization, Brussels Belgium, pren 15129 (2007): Anti-seismic Devices - draft European Standard submitted to CEN members for second enquiry, European Committee for Standardization, Brussels Belgium. Acknowledgments The author expresses his thanks to all the experts participating in the LESSLOSS Project and the technical staff at the ENEA Casaccia Laboratory. Special recognition goes to the following persons: - Prof. Ing. Gian Michele Calvi from University of Pavia, Scientific Co-ordinator of the overall Project - Dr. Massimo Forni from ENEA Bologna, Co-ordinator of Sub-project 6 - Mr. Sebastian Fischer from MAURER SÖHNE Munich.