Differential indicators

Similar documents
mandata_us :43 Pagina 83 (1,1) FHB 82

FMM 050 uk :26 Pagina 5 (1,1) FMM 050

FMP :41 Pagina 5 (1,1) FMP

Maximum pressure 80 bar

LMP 210. Style B. Style S. Maximum pressure 60 bar F l o w r a t e s t o l / m i n

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.

PRESSURE GAUGE SELECTORS

Polígono Indutrial O Rebullón s/n Mos - España -

CHINA MP FILTRI P.O. Box Shanghai Phone: Fax:

Flow rates to 485 l/min

AIR BREATHER FILTERS. Temperature from -25 to +100 C

Flow rates to 485 l/min

Flow rates to 485 l/min

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

SERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

Polígono Indutrial O Rebullón s/n Mos - España -

VISUAL LEVEL INDICATORS

Flow rates to 475 l/min

AIR BREATHER FILTERS. Temperature from -25 C to +100 C

Flow rates to 750 l/min

Flow rates to 750 l/min

STAINLESS STEEL FILTER

ED 701 General Industry Pressure Transmitter

SERIES INLINE FILTERS LMP 210. Maximum pressure 60 bar Maximum flow to l / mi n

Nylon oil filler and air breather filler caps

Element description. Multipass test in compliance ISO Contaminant ISO MTD. A - Microfibre

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

High Pressure fi lters

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

LMP series Filter element according to DIN Maximum pressure up to 30 bar - Flow rate up to 2000 l/min

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

Direct-operated 2/2-way solenoid valves Type EV210B

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

MPT Multifunction Multiport

SERIES. Maximum pressure 8 bar

Cooler-Bypass Thermostat Valve, Size 10

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

Spin-on fi lters. MPS series. Maximum pressure up to 12 bar - Flow rate up to 365 l/min. Spin-on fi lters

331 Low & Medium Pressure filters

Pressure Transmitter ED 701

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

Flow rates to 590 l/min

HVM 061 Page 1/4 Elektrohydraulic Servovalves Typ HVM 061 Symbol A B P T L Special features: high reliability easy service robust construction high dy

Return fi lters. MPI series. Maximum working pressure up to 1 MPa (10 bar) - Flow rate up to 3000 l/min

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Operating Instructions for Digital Manometer. Model: MAN-SD

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Pressure transmitters for industrial applications MBS 32 and MBS 33

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

387 Low & Medium Pressure filters

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min

RFM. 300 kpa (3 bar) Return Filters RFM. Ports: 3/8 2 1/2 Flow rates: l/min

Direct-operated 2/2-way compact solenoid valves Type EV210A

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Solenoid valves 2/2-way direct-operated type EV210A

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

VALVES B D E B D A. ISO /2 Valves CHARACTERISTICS CODIFICATION KEY. BD 18 mm. BD 26 mm

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

35RP2 35RP2 HM 2 HM 3 35RP2. Type. Series Variation. Rack and pinion type Bore (mm) Rotating angle Angle adjustment.

MPF SERIES RETURN FILTER

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

PRODUCT CATALOGUE PREssURE switch

VOLUMEC. Valve Position Indicator 5

MRH. Return Filters RETURN FILTER

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

ISO mm ISO mm. Nl/min. Nl/min. Nl/min. Nl/min. ISO /2 Distributors. ISO Interface. OVERSIZED interface (UNIVER original)

100Z-1 100Z-1 51 HA 50. Cushion ring Cushion ring. Type. Standard type. Switch Set

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Metal air breather filter

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 8700 psi Nominal flow rate up to gpm us

Non-Contact Safety Systems CMS

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

Cartridge Valves Technical Information. Quick reference

2/2-3/2 POPPET VALVES FOR VACUUM (1/8"-6/4") Series AG

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

all stainless steel transducer multimedia compatibility

Industrial Pressure Transmitter

Modular Style Air Combination. Assembled by simply tightening the screws

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430

Suction fi lters. MPA - MPM series. Flow rate up to 875 l/min. Suction fi lters

MADILL MBT GRAPPLE RETURN TO INDEX

Transcription:

Differential indicators 5-07-006 7:8 Pagina 5 (,) Differential indicators A guarantee of maintenance to the correct ISO 06 contamination class achieved through the use of the filters can be provided exclusively with the correct use of the specific clogging indicators. The trip threshold of the indicator must be selected taking account of the maximum differential pressure indicated for each type of filter element and the trip pressure of the bypass valve, if incorporated in the filter. Indicator body ( M a t e r i a l s ) Brass P r e s s u r e Max. working pre s s u re : 0 bar ( MPa) Te m p e r a t u re From - 5 C to + 0 C S e a l s HNBR FPM C o m p a t i b i l i t y Bodies compatible with: Mineral oils to ISO 9 - aqueous emulsions Synthetic fluids, water and glycol. V and H series FPM and HNBR seals, compatible with: Mineral oils to ISO 9 - aqueous emulsions Synthetic fluids, water and glycol. For synthetic fluids type HS-HFDR-HFDS-HFDU, seals in FPM V series. 5

Differential indicators 5-07-006 7:8 Pagina 8 (,) Order code Order code 5 6 7 8 Example: E 7 Example: NM 8 C P0 - Styles - Styles V Visual NR Electrical E Electric -Visual KR Electric -Visual J Electrical -Visual - Thermostat controlled NM Electric IP 67 - Differential trip pressure 6 bar ± 0% 7 5 bar ± 0% 8 7 bar ± 0% 9 0 bar ± 0% - Seals FPM Standard Z Visual N Electric K Electric - Visual NE Electronic - Differential trip pressure 6 bar ± 0% 7 5 bar ± 0% 8 7 bar ± 0% x Other information on request 9 0 bar ± 0% Seal for indicator/filter head, Bonded Seal. - Power supply voltage* (only for style K - KR) Volt 0 Volt (DC only for KR) 0 Volt (not available for KR) ADAPTER Order code ICPAP0 - Seals H V x HNBR Standard FPM Others on request 5 - Thermostat (only for NM style) A Without C 50 6 - Electrical connector (only for NM style) AMP Superseal connector 7 - Options (only for style NE) S Standard T Double contact 75% - 00% 6 sec. signalling delay 8 - Options P0 MP standard 8 Seal for indicator/filter head, flat profiled. * Other supply voltage on request.

Differential indicators 5-07-006 7:8 Pagina 8 (,) STYLE TECHNICAL CHARACTERISTICS SERIES Z VISUAL Standard visual indicator with manual reset. Nylon signalling button. Button depressed position Button raised position, Red = cartridge clean. = cartridge clogged. 8 g SERIES V VISUAL Cover and lens in nylon. Visual indicator green Visual indicator red = cartridge clean. = cartridge clogged. 7 g 95 Nm. SERIES E ELECTRIC / VISUAL 5 A/50V~ Voltage 0 V~ N.C. DIN 650 Microswitch contact Cover and lens in nylon. Visual indicator green = cartridge clean. Visual indicator red = cartridge clogged. We i g h t : 88 gr. 95 Nm. SERIES J ELECTRIC / VISUAL WITH THERMOSTAT CONTROL 5 A/50V~ Voltage 0 V~ DIN 650 Microswitch contact Cover and lens in nylon. N.C. T 0 C Visual indicator green = cartridge clean. Visual indicator red = cartridge clogged. CONTACT Operation on reaching temperature of + 0 C We i g h t: 98 gr. 95 Nm. 9

Differential indicators 5-07-006 7:8 Pagina 8 (5,) Differential indicator dimensions 5 Ch. 0 Ch. Ch. 0 SERIES Z SERIES V SERIES NR - KR,5 Ch. Ch. SERIES E SERIES J Ch. 7 SERIES NM with Thermostat Ch. 7 SERIES NM without Thermostat 5 Ch. 0 Ch. 0 Ch. 7 SERIES N - K - NE SERIES NE...T ICPAP0 7

Differential indicators 5-07-006 7:8 Pagina (,) STYLE TECHNICAL CHARACTERISTICS SERIES K ELECTRIC / VISUAL 5 A/V~ Voltage V DC - 5V DC/AC - 0V AC N.C. LED DIN 650 Microswitch contact SIGNALLING LEDS : GREEN LED = Cartridge clean. RED LED = Cartridge clogged. We i g h t : 8 gr. SERIES N ELECTRIC 5 A/50V~ Voltage 0 V~ N.C. DIN 650 Microswitch contact We i g h t: 8 gr. SERIES KR ELECTRIC / VISUAL N.C. LED Carico massimo sui contatti 0,8 A/V DC 0,7 A/5V DC V - 5V DC DIN 650 Reed switch SIGNALLING LEDS : GREEN LED = Cartridge clean. RED LED = Cartridge clogged. gr. SERIES NR ELECTRIC N.C. LED 0,7 A/5V DC Voltage max 0V DC DIN 650 Reed switch Weight : gr. Tightening torq u e: SERIES NM.A AMP Superseal Cable and cable gland PVC 0,7 A/5V DC Voltage max 0V DC Protection rating IP 67 Contacts Weight : Tightening torq u e : 0 gr. 0

Differential indicators 5-07-006 7:8 Pagina (,) STYLE TECHNICAL CHARACTERISTICS SERIES NM.C AMP Superseal Cable and cable gland PVC 0,7 A/5V DC Voltage max 0V DC Protection rating IP 67 Contacts Thermostat () Switching + 50 C T 50 C Weight : Tightening torq u e: 6 gr. SERIES NE = + VCC = Out - 0 ma = - VCC Voltage From 9 to 8 VCC Output signal - 0 ma Input impedance 00 Ohm Non-linearity + hysteresis 0% of full scale Thermal deviation from zero < 5% of full scale from 0 C to + 60 C Operating temperature From - 0 C a + 80 C Storage temperature From - 5 C a + 0 C DIN 650 Tightening torq u e: 00 gr. INDICATOR NE...T = + VCC = Out > 0 ma = - VCC = Out NA 6 ma 5= Out NA 0 ma 5 Protection rating IP 67 Power supply voltage From 9 to 8 VCC Output signal - 0 ma Input impedance 00 Ohm Non-linearity + hysteresis 0% of full scale Thermal deviation from zero < 5% of full scale from 0 C to + 70 C N alarm threshold NA a 6 ma (75% of full scale) N N.O alarm threshold NA a 0 ma (00% of full scale) Fixed timer interval threshold N and N 6 seconds Operating temperature From - 0 C to + 80 C Storage temperature From - 5 C to + 0 C M 5 pin IEC 6097-5- We i g h t : 50 gr. ADAPTER ICPAP0 IN Adapter for oil outlet and pressure sensing up-stream and down-stream from the filter element. OUT IN/OUT connections G / Orientation: IN/OUT connections 60 Material: Phosphated steel Seals: NBR (others on request)