version ISOL METHOD MASS SEPARATOR MASHA CHARGE STATES...5

Similar documents
Reverse technique for A1900

LISE++ tutorial. The tutorial walks you through the required steps to try to fulfill the experimentalists requests:

Secondary beam production with fragment separators

Optics Minimization in LISE ++

Wien filter revision. version Contents: Setting Wien filter in LISE++ Transport solution of Wien-filter optics

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

Experimental data analysis at the MASHA setup. Prepared by: Abeer M. Attia Supervisor: Lubos Krupa LOGO. Aleksey Novoselov

Minicourse on Experimental techniques at the NSCL Fragment Separators

Alpha-Energies of different sources with Multi Channel Analyzer

SYNTHESIS OF SUPERHEAVY ELEMENTS USING THE MASS SPECTROMETER MASHA

STATUS OF THE CAVIAR DETECTOR AT LISE-GANIL

Relativistic Electrons

Introduction : Production & Separation

THE SUPER-FRS PROJECT AT GSI

Software BioScout-Calibrator June 2013

3-D MEASUREMENT OF THE NSCL POSITION-SENSITIVE GAMMA RAY DETECTOR ARRAY

Isomers in LISE++ Version from 01/16/06 available through LISE sites

The program LISE: a simulation of fragment separators

Sample Alignment (2D detector) Part

An Introduction to. Ion-Optics. Series of Five Lectures JINA, University of Notre Dame Sept. 30 Dec. 9, Georg P. Berg

ISIS/Draw "Quick Start"

Mass Determination of Rn and Hg isotopes using MASHA

Jasco V-670 absorption spectrometer

The neutron multiplicity study at spontaneous fission of short-lived isotopes (z > 100) using VASSILISSA recoil separator

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

LCLS Injector Straight Ahead Spectrometer C.Limborg-Deprey Stanford Linear Accelerator Center 8 th June 2005

NMR Predictor. Introduction

Sample Alignment Part

An Introduction to the Ion-Optics of Magnet Spectrometers

Creation and modification of a geological model Program: Stratigraphy

DEVELOPMENT OF LARGE SCALE OPTIMIZATION TOOLS FOR BEAM TRACKING CODES*

Status of the caviar detector at LISE-GANIL

Information on the test material EDS-TM002 and the BAM software package EDX Spectrometer Test for determination of the spectrometer performance

BUILDING BASICS WITH HYPERCHEM LITE

Developments of the RCNP cyclotron cascade

QuantumMCA QuantumNaI QuantumGe QuantumGold

An area chart emphasizes the trend of each value over time. An area chart also shows the relationship of parts to a whole.

Obtaining the Center of Gravity, Volume, Weight and More

Experiment for synthesis of neutrondeficient

Center of Mass. Evaluation copy

ST-Links. SpatialKit. Version 3.0.x. For ArcMap. ArcMap Extension for Directly Connecting to Spatial Databases. ST-Links Corporation.

Work and Energy. This sum can be determined graphically as the area under the plot of force vs. distance. 1

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

DIANA A NEXT GENERATION DEEP UNDERGROUND ACCELERATOR FACILITY

A PRELIMINARY ALIGNMENT PLAN FOR RIA AT MSU

Verification of a Micropile Foundation

C NS. Direct reactions of Borromean nuclei FM50. S. Shimoura CNS, University of Tokyo

Accurate calculation of the optical transmission of high resolving spectrometer

Computer simulation of radioactive decay

Thesis and PhD themes

Tutorial 23 Back Analysis of Material Properties

You w i ll f ol l ow these st eps : Before opening files, the S c e n e panel is active.

Graphical User Interfaces for Emittance and Correlation Plot. Henrik Loos

Determining the Concentration of a Solution: Beer s Law

The Super-FRS Project at GSI

Electromagnetic Forces on Parallel Current-

Heavy Ion Accelerators for RIKEN RI Beam Factory and Upgrade Plans. Upgrade Injector

BETA-RAY SPECTROMETER

Quantification of JEOL XPS Spectra from SpecSurf

Abstract. 1. Introduction

McIDAS-V Tutorial Displaying Point Observations from ADDE Datasets updated July 2016 (software version 1.6)

Automatic Watershed Delineation using ArcSWAT/Arc GIS

Rare isotope beams production using fusion-fission reactions

Safety Co-ordinator : Patrick Walden, TRIUMF, ext : 7340

Esri EADA10. ArcGIS Desktop Associate. Download Full Version :

GANIL STATUS REPORT. B. Jacquot, F. Chautard, A.Savalle, & Ganil Staff GANIL-DSM/CEA,IN2P3/CNRS, BP 55027, Caen Cedex, France.

Nucleon Transfer within Distorted Wave Born Approximation

Lasentec Product Group

Calibrating Thermo Exactive with the Direct Analysis in Real Time (DART) Ambient Ionization Source (Protocol Adapted from US FDA FCC)

3.5. Accelerator Mass Spectroscopy -AMS -

FODO Cell Introduction to OptiM

The Kalzium Handbook. Carsten Niehaus

Capabilities at the National Superconducting Cyclotron Laboratory. Sean Liddick NDNCA workshop, May 26-29, 2015

MARS status report for : Development of rare isotope beams of 25 Si, 6 He, 9 Li, 23 Si, and 22 Si

THE CRYSTAL BALL FORECAST CHART

Spectrometer User s Guide

Full-Acceptance Detector Integration at MEIC

26.6 The theory of radioactive decay Support. AQA Physics. Decay constant and carbon dating. Specification reference. Introduction.

Mobile Mapping Tips and Tricks

Design Note TRI-DN Low Energy Beam Transport Line for the CANREB Charge State Breeder

Creation and modification of a geological model Program: Stratigraphy

Measuring ph with Smart Cuvettes

Last updated: Copyright

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Status of the magnetic spectrometer PRISMA

6.0 Graphs. Graphs illustrate a relationship between two quantities or two sets of experimental data.

Radioactivity. (b) Fig shows two samples of the same radioactive substance. The substance emits β-particles. Fig. 12.1

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Physics 476LW Advanced Physics Laboratory Atomic Spectroscopy

SFT3000S Measurement of Sn-Cu Coating

AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING

Method of active correlations in the experiment 249 Cf+ 48 Ca n

Life Cycle of Stars. Photometry of star clusters with SalsaJ. Authors: Daniel Duggan & Sarah Roberts

Generator. Introduction. Modeling in COMSOL Multiphysics

TUTORIAL Solar Module Physical Model

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Lab VI Light Emitting Diodes ECE 476

COMMISSIONING OF THE COUPLED CYCLOTRON SYSTEM AT NSCL

Refurbishment of the Electrostatic Accelerators of ithemba LABS

Transcription:

version 6.5 Contents: 1. ISOL METHOD... 2 1.1. MASS SEPARATOR MASHA...3 1.2. CHARGE STATES...5 2. OTHER... 6 2.1. ELECTRIC DIPOLE: SEPARATION PLANE...6 2.2. WEDGE ANGLE DIALOG...6 2.3. MSP-144 MODIFICATION...7 ACKNOWLEDGEMENTS... 7 REFERENCE:... 7 www.nscl.msu.edu/lise dnr080.jinr.ru/lise East Lansing January-2004

1. ISOL method The code does not simulate processes in the ISOL-target (number of produced fragments, diffusion, extraction time etc). The new method is a combination of the so-called ISOL method of production and separation of radioactive nuclei with the classical method of mass analysis. This new method named ISOL-method has been incorporated to estimate fragment transmission through a spectrometer, and help with spectrometer tuning. Using LISE++ graphical utilities the user can observe spatial and energy distributions after any optical block. The ISOL mode can be set in the Production mechanism dialog (menu Options ). The buttons Target, Stripper, and Setting fragment are absent in this mode. The user can only set parameters of the projectile and choose a spectrometer configuration. Nuclei produced in nuclear reactions are emitted from an ECR ion source at energy E = q U, where q is the ion charge of nuclide, and U is the voltage in kv. For this mode the new possibility of entering the energy in kv has been Fig.1. The Beam dialog. developed (see Fig.1). The next step is the calculation of spectrometer settings for the chosen projectile using the button in the toolbar or calling the command Calculate the spectrometer for setting ion from the menu Calculations. To calculate an ion rate and get the window of transmissions the user has to click the right button of the mouse on the isotope of interest in the chart of nuclides. The energy of nuclide is calculated based on the voltage value U entered for the projectile and its ionic charge. It is assumed initially that the intensities of other fragments are equal to the intensity of the projectile. Instead of the cross section value in other modes the ISOL mode operates by defining an Intensity coefficient (see Fig.2). However the user Fig.2. The transmission statistic window. can change the intensity coefficient using the Cross sections dialog or load a coefficient file through the Cross Section file dialog. The intensity coefficient should be proportional to the production cross section of the given nuclide and the coefficient of extraction from ECR. It is possible to use the PACE4 code (or LisFus model) to estimate the production cross sections. The file with calculated cross sections can be loaded as intensity coefficients using the Cross section file dialog (see documentation for version 6.4). - 2 -

1.1. Mass separator MASHA The configuration file of the mass separator MASHA [Oga03] operating in ISOL-mode has been created and incorporated in the LISE++ installation package: LISE++ file: Files\examples\MASHA.lpp Configuration file: Config\Dubna\MASHA.lcn Fig.4. LISE++ scheme of MASHA separator. The separator MASHA set-up window and its scheme are shown in Fig.3 and Fig.4. The MASHA configuration file provides by calibration files of magnetic dipoles that help the user to tune the mass separator. Envelopes of 276 B0 1+ and 275 B0 1+ nuclides through the MASHA mass separator tuned on the ion 276 B0 1+ are shown in Fig.5. The projectile initial emittance used in that calculation Fig.3. MASHA separator set-up window. was the following: x=y=0.5 mm, = =20 mrad, dp/p=0.01%. Some examples of fragment transmission calculation under different initial conditions are presented in Fig.6. Fig.5. Envelopes of 276 B0 1+ and 275 B0 1+ nuclides through the MASHA mass separator tuned on the ion 276 B0 1+. - 3 -

Fig.6. Two-dimensional identification plots of nuclides transmitted through the mass separator and registered by the final focal plane positionsensitive detector. The spectrometer is set to 276 B0 1+. The top figure corresponds to the projectile initial emittance x=y=0.5 mm, = =20 mrad, dp/p=0.01%; the middle figure to x=2.5mm, y=0.5 mm, = =20 mrad, dp/p=0.01%; the bottom plot to x=y=0.5 mm, = =20 mrad, dp/p=0.05%. - 4 -

1.2. Charge states It is recommended to turn the Charge state option off, because the output of ions with a charge more than 1+ is small in this energy region (some tenth of KeV). Moreover, other charge states will be suppressed by the spectrometer, which is tuned on ions with 1 +. The next example proves this statement. For this purpose it is necessary to turn off all slits and turn on the Charge state option. For the ISOL method the code assumes that the output of ions with charge q=(n+1)+ is 10 times less than the output of ions with charge q=n+ (see Fig.7). In this case ions with different charge will be easily differentiated in the plots (see Fig.8). In the figure it is visible that the ions with q=2 + are located away from q=1+ by two meters, much greater than the sizes of the detector. Moreover charges with q >1 will not go through the first dipole. It is easy to check this statement. Fig.7. The transmission statistic window. Fig.8. Horizontal spatial distribution of ions in the final focal plane of mass separator MASHA. Spectrometer settings are shown in the figure. - 5 -

2. Other 2.1. Electric dipole: separation plane A Separation plane frame has been added to the Electric dipole dialog (see Fig.9) to select the plane where the electric rigidity selection is applied (E-plane). The magnetic rigidity selection is applied to the perpendicular plane (M-plane). This modification was introduced because of a specific case in the MA- SHA spectrometer where after the electrical dipole both dispersions in vertical and horizontal planes are not equal to zero. Fig.9. The Electric dipole dialog. 2.2. Wedge angle dialog Wedge angle calculations basing on formulae from [Gei89] have been added to the Wedge angle dialog (Fig.10). The code calculates the transfer matrix between the wedge block and the point chosen in the dialog to get the spatial magnification and dispersion coefficients. This method of wedge angle calculation does not take into account materials which can be located between the wedge and the final point. Fig.10. The Wedge angle dialog. - 6 -

2.3. MSP-144 modification The possibility to input a projectile energy in the MSP144 dialog was developed (see Fig.11). The algorithm to search the magnetic field B from E and X has been corrected. Acknowledgements The authors gratefully acknowledge Dr.V.Shchepunov (Dubna, Oak Ridge) for help with the development of the MASHA spectrometer configuration for LISE++. Fig.11. The MSP144 dialog Reference: [Gei89] H.Geissel et al., NIM A 282 (1989) 247-260. [Oga03] Yu.Oganessian et al., NIM B 204 (2003) 606-613. - 7 -