Technical Data Sheet for AvK-Alternators

Similar documents
Technical Data Sheet for AvK-Alternators

CENTRAL TERMOELÉCTRICA ANDINA UNIDAD Nº 1

I/IN (D) Kriva momenta i struje Torque and current curves Moment und Strom Kurven. - a / r

Synchronous Machines

ECE 325 Electric Energy System Components 7- Synchronous Machines. Instructor: Kai Sun Fall 2015

Introduction to Synchronous. Machines. Kevin Gaughan

CHAPTER 3 ANALYSIS OF THREE PHASE AND SINGLE PHASE SELF-EXCITED INDUCTION GENERATORS

GENERATOR INTERCONNECTION APPLICATION

University of Jordan Faculty of Engineering & Technology Electric Power Engineering Department

KINGS COLLEGE OF ENGINEERING Punalkulam

Analyzing the Effect of Ambient Temperature and Loads Power Factor on Electric Generator Power Rating

Lesson 17: Synchronous Machines

Single Phase Motors Technical Datasheets

EE2351 POWER SYSTEM OPERATION AND CONTROL UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A

Chapter 4. Synchronous Generators. Basic Topology

UNIT I INTRODUCTION Part A- Two marks questions

CHAPTER 5 SIMULATION AND TEST SETUP FOR FAULT ANALYSIS

Energy Converters. CAD and System Dynamics

Equivalent Circuits with Multiple Damper Windings (e.g. Round rotor Machines)

EEE3405 ELECTRICAL ENGINEERING PRINCIPLES 2 - TEST

Generators. What its all about

Final Exam, Second Semester: 2015/2016 Electrical Engineering Department

AC axial compact fan

B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Prince Sattam bin Abdulaziz University College of Engineering. Electrical Engineering Department EE 3360 Electrical Machines (II)

A. P. Sakis Meliopoulos and George J. Cokkinides Power System Relaying, Theory and Applications. Chapter 8 2 Generator Protection 2

ROEVER COLLEGE OF ENGINEERING & TECHNOLOGY ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ELECTRICAL MACHINES I

Tutorial 1 (EMD) Rotary field winding

CHAPTER 2 CAPACITANCE REQUIREMENTS OF SIX-PHASE SELF-EXCITED INDUCTION GENERATORS

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL

Electrical Machines and Energy Systems: Operating Principles (Part 2) SYED A Rizvi

Module 3 : Sequence Components and Fault Analysis

Chapter 6: Efficiency and Heating. 9/18/2003 Electromechanical Dynamics 1

QUESTION BANK ENGINEERS ACADEMY. Power Systems Power System Stability 1

LESSON 20 ALTERNATOR OPERATION OF SYNCHRONOUS MACHINES

Dynamics of the synchronous machine

SCHOOL OF ELECTRICAL, MECHANICAL AND MECHATRONIC SYSTEMS. Transient Stability LECTURE NOTES SPRING SEMESTER, 2008

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Electric Machines

AC axial compact fan

AC axial compact fan

TRANSIENT ANALYSIS OF SELF-EXCITED INDUCTION GENERATOR UNDER BALANCED AND UNBALANCED OPERATING CONDITIONS

JRE SCHOOL OF Engineering

Synchronous Machines

Jerad P. 10/1/2015. Motor Thermal Limits on Torque Production (Frameless Motor Level)

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous)

EE 410/510: Electromechanical Systems Chapter 4

Electromagnetic Energy Conversion Exam 98-Elec-A6 Spring 2002

Flux: Examples of Devices

Chapter 9: Transient Stability

POWER SYSTEM STABILITY AND CONTROL

ECEN 460 Exam 1 Fall 2018

CHAPTER 6 STEADY-STATE ANALYSIS OF SINGLE-PHASE SELF-EXCITED INDUCTION GENERATORS

AC axial compact fan

Experimental Testing and Model Validation of a Small-scale Generator Set for Stability Analysis.

System Components. Electric Motors.

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

An Introduction to Electrical Machines. P. Di Barba, University of Pavia, Italy

+ ( )= with initial condition

RESULTS OF ON-GRID OPERATION OF SUPERCONDUCTOR DYNAMIC SYNCHRONOUS CONDENSER

Synchronous Machines

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Siemens AG Rated Rated current 1FK7 Compact. I rated (15.4) 11.5 (25.4) (2.9) 3.3 (4.4)

From now, we ignore the superbar - with variables in per unit. ψ ψ. l ad ad ad ψ. ψ ψ ψ

CHAPTER 3 INFLUENCE OF STATOR SLOT-SHAPE ON THE ENERGY CONSERVATION ASSOCIATED WITH THE SUBMERSIBLE INDUCTION MOTORS

Power System Stability and Control. Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India

Comparative Study of Synchronous Machine, Model 1.0 and Model 1.1 in Transient Stability Studies with and without PSS

Single Phase Motors Technical Datasheets

Digital AC Motors MHD

Electrical Machines and Energy Systems: Operating Principles (Part 1) SYED A Rizvi

DESIGN OF ELECTRICAL APPARATUS SOLVED PROBLEMS

POWER SYSTEM STABILITY

ECE 585 Power System Stability

Induction Motors. The single-phase induction motor is the most frequently used motor in the world

MATLAB SIMULINK Based DQ Modeling and Dynamic Characteristics of Three Phase Self Excited Induction Generator

Micro-grid to System Synchronization Based on Pre-Insertion Impedance Method (Version 1.0) By Peter Zhou University of Alberta Jan 30 th, 2015

THE UNIVERSITY OF NEW SOUTH WALES. School of Electrical Engineering & Telecommunications FINALEXAMINATION. Session

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake

UNIVERSITY OF SWAZILAND FACULTY OF SCIENCE DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING. MAIN EXAMINATION May 2013

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

Self-Tuning Control for Synchronous Machine Stabilization

8 z 2, then the greatest value of z is. 2. The principal argument/amplitude of the complex number 1 2 i (C) (D) 3 (C)

Generation, transmission and distribution, as well as power supplied to industrial and commercial customers uses a 3 phase system.

Control of Wind Turbine Generators. James Cale Guest Lecturer EE 566, Fall Semester 2014 Colorado State University

Electric Machines I Three Phase Induction Motor. Dr. Firas Obeidat

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Concept Design and Performance Analysis of HTS Synchronous Motor for Ship Propulsion. Jin Zou, Di Hu, Mark Ainslie

Dynamic Voltage Stability Enhancement of a Microgrid with Static and Dynamic Loads Using Microgrid Voltage Stabilizer

The synchronous machine (detailed model)

EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION

PROPOSAL FOR ADDITION OF IEC 34-4 STANDARD IN PART FOR DETERMINATION OF POTIER REACTANCE

INDUCTION MOTOR MODEL AND PARAMETERS

You know for EE 303 that electrical speed for a generator equals the mechanical speed times the number of poles, per eq. (1).

DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLOGY Mamalapuram Chennai QUESTION BANK V SEMESTER. EE6501-Power system Analysis

ECEN 667 Power System Stability Lecture 18: Voltage Stability, Load Models

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

EE 6501 POWER SYSTEMS UNIT I INTRODUCTION

Doubly salient reluctance machine or, as it is also called, switched reluctance machine. [Pyrhönen et al 2008]

Determination of a Synchronous Generator Characteristics via Finite Element Analysis

ELECTRICALMACHINES-I QUESTUION BANK

Transcription:

Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 2/1/14 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dsg74l1_6_6_69_a48m965 Object data: Site: Prime Mover: Application: Stationary Power Plant Manufacturer: Generator data: Generator: Poles: 6 Standards: IEC 634 Rated power: 127 kva 116 kwe 165 kwm Power factor:.8 Power at pf 1, 13 kva 13 kwe 165 kwm Rated voltage:.69 kv Speed: 12 1/min Frequency: 6 Hz Voltage range / frequency range: Rated current: 162.7 A Zone A according IEC 634-1 (du = +/-5%, df = +/-2%) Winding pitch: ca. 5/6 Insulation class: Stator: Class H Rotor: Class H Temperature rise: H Ambient temperature: 4 C Environment: Standard environment Site altitude: 1 m Enclosure: IP23 Filter: Cooling: IC 1 - Open-circuit ventilation Coolant: Ambient Air Temperature Coolant: 4 C Temperature Air inlet generator: 4 C Cooling air vol.: 1.9 m³/s Cooling water quantity: n/a Moment of inertia (I): 47.8 kgm² Weight: 3575 Kg Losses (environment): Losses (cooling): Wires: 4 terminals, starpoint connected in terminal box Operation mode: Single mode Regulators: Voltage regulator: DECS 1 49 KW n/a Electrical data: (acc. IEC) Efficiencies: 11% 1% 75% 5% 25% Power factor.8 95,16 95,39 95,67 95,55 93,71 Power factor.9 95,87 96,7 96,22 95,96 93,97 Power factor 1. 96,58 96,74 96,76 96,36 94,22 Reactances and time constants unsaturated saturated unsaturated saturated x d 2.8 1.88 p.u. x q.97.95 p.u. T d' 2.3388 s T d''.2422 s x d'.245.245 p.u. x q'.97.95 p.u. T d'.28 s T q'.2274 s x d''.127.115 p.u. x q''.139.139 p.u. T d''.1137 s T q''.15869 s x 2.139.126 p.u. x.47.43 p.u. T a.2363 s T q'.2274 s x 1s n.a..69 p.u. T q''.2274 s Short circuit ratio saturated:.53 Z n.375 Ohm Short circuit data: Initial short circuit current (3-phase): I k'' 9241 A Max. peak current (3-phase): I S 23524 A Sustained short circuit current: I k 3188 A Minimum 3 x rated current for max.1 s Initial short circuit torque: M k2 114.2 knm M k3 68.5 knm Max. faulty synchron moment: M f 245.5 knm Rated kva torque: M SN 1.11 knm Rated torque M N 8.9 knm Shaft torque MSh 8.48 knm Load application: max. load application: 778 kva(corresponds to 61,23 % from 127 kva) for Power factor.4 15% transient voltage drop Remarks: Power: 127 kva Power factor:.8 transient voltage drop: -19.7 %

Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 2/1/14 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dsg74l1_6_6_69_a48m965 Object data: Site: Prime Mover: Application: Stationary Power Plant Manufacturer: Generator data: Generator: Poles: 6 Standards: IEC 634 Rated power: 127 kva 116 kwe 165 kwm Power factor:.8 Power at pf 1, 13 kva 13 kwe 165 kwm Rated voltage:.69 kv Speed: 12 1/min Frequency: 6 Hz Voltage range / frequency range: Rated current: 162.7 A Zone A according IEC 634-1 (du = +/-5%, df = +/-2%) Winding pitch: ca. 5/6 Insulation class: Stator: Class H Rotor: Class H Temperature rise: H Ambient temperature: 4 C Environment: Standard environment Site altitude: 1 m Enclosure: IP23 Filter: Cooling: IC 1 - Open-circuit ventilation Coolant: Ambient Air Temperature Coolant: 4 C Temperature Air inlet generator: 4 C Cooling air vol.: 1.9 m³/s Cooling water quantity: n/a Moment of inertia (I): 47.8 kgm² Weight: 3575 Kg Losses (environment): Losses (cooling): Wires: 4 terminals, starpoint connected in terminal box Operation mode: Single mode Regulators: Voltage regulator: DECS 1 49 KW n/a Electrical data: (acc. IEC) Efficiencies: 11% 1% 75% 5% 25% Power factor.8 95,16 95,39 95,67 95,55 93,71 Power factor.9 95,87 96,7 96,22 95,96 93,97 Power factor 1. 96,58 96,74 96,76 96,36 94,22 Reactances and time constants unsaturated saturated unsaturated saturated x d 2.8 1.88 p.u. x q.97.95 p.u. T d' 2.3388 s T d''.2422 s x d'.245.245 p.u. x q'.97.95 p.u. T d'.28 s T q'.2274 s x d''.127.115 p.u. x q''.139.139 p.u. T d''.1137 s T q''.15869 s x 2.139.126 p.u. x.47.43 p.u. T a.2363 s T q'.2274 s x 1s n.a..69 p.u. T q''.2274 s Short circuit ratio saturated:.53 Z n.375 Ohm Short circuit data: Initial short circuit current (3-phase): I k'' 9241 A Max. peak current (3-phase): I S 23524 A Sustained short circuit current: I k 3188 A Minimum 3 x rated current for max.1 s Initial short circuit torque: M k2 114.2 knm M k3 68.5 knm Max. faulty synchron moment: M f 245.5 knm Rated kva torque: M SN 1.11 knm Rated torque M N 8.9 knm Shaft torque MSh 8.48 knm Load application: max. load application: 778 kva(corresponds to 61,23 % from 127 kva) for Power factor.4 15% transient voltage drop Remarks: Power: 127 kva Power factor:.8 transient voltage drop: -19.7 %

Eta [%] Alternator : Rated output [kva] 127 Rated power factor:.8 Rated voltage [kv]:.69 Rated frequency [Hz] 6 Rated speed [rpm] 12 Wirkungsgrad-Kennlinie - Efficiency Curve 98. 97. 96. 95. 94. 93. 92. 91. PF=,8 PF=,9 PF=1 Load [% rated load] 9. 2 3 4 5 6 7 8 9 1 11 dsg74l1_6_6_69_b Revision B Efficiency 5.2

Transient voltage drop / Transient voltage rise [%] Alternator : Rated output [kva] 127 Rated power factor:.8 Rated voltage [kv]:.69 Rated frequency [Hz] 6 Rated speed [rpm] 12 Transient Voltage rise or drop for sudden load removal or application 3 2 1 1 p.f.,8 p.f.,4 p.f.,1 p.f. -1-2 -3-4 Sudden load removal / sudden load application in [%] of rated load depending from power factor -1-75 -5-25 25 5 75 1 125 dsg74l1_6_6_69_b Revision B Voltage drop-rise 5.3

Mk/MSN in p.u. Alternator : Rated output [kva] 127 Rated power factor:.8 Rated voltage [kv]:.69 Rated frequency [Hz] 6 Rated speed [rpm] 12 MSN related to kva: 1.11 KNm 15 Kurzschlußmomenten-Verlauf 2-poliger KS Short circuit torque at 2-phase SC 1 5 1 1 19 28 37 46 55 64 73 82 91 1 19 118 127 136 145 154 163 172 181 19 199 28 217 226 235 244 253 262 271 28 289 298-5 -1-15 t / ms dsg74l1_6_6_69_b Revision B MK2 5.5

Kurzschlussstrom Ik3phasig / IN [p.u.] Short-circuit current Ik3phase / IN [ p.u. ] Nenndaten / nominal data Leistung S N : 127 kva cos j:.8 Rating p.f. Spannung U N :.69 kv Strom I N : 163 A Voltage Current Frequenz f: 6 Hz Drehzahl n: 1,2 min -1 Frequency Speed Schutzart IP23 Protection Stosskurzschluss-Strom, 3-phasig, asymmetrisch / Sudden short circuit current, 3-phase, asymmetrical 2. 15. 1. 5.. -5. -1..1.2.3.4.5 Zeit [sec.] Time Notizen / remarks: Maximum asymmetric peak value I speak = 17851 A or 16.8 p.u. Alle Angaben gemäß VDE 53, IEC6 34 All data according VDE 53, IEC6 34 dsg74l1_6_6_69_b Revision B IKasym3-5.7

Strom I 1 /I N [p.u.] Current Nenndaten / nominal data Leistung S N : 127 kva cos j:.8 Rating p.f. Spannung U N :.69 kv Strom I N : 163 A Voltage Current Frequenz f: 6 Hz Drehzahl n: 12 min -1 Frequency Speed Schutzart IP23 Protection 5. Überlast Kennlinie Overload capability 4.5 4. 3.5 3. 2.5 2. 1.5 1..5. 1 1 1 1 Zeit [s] 1 Time Notizen / remarks: Strom / Zeit Kriterien: ( I / I N ) 2 *t =45s Current/time characteristics: 1,5*I N for 3 s 1,1*I N for 1 h in 6h Alle Angaben gemäß VDE 53, IEC6 34 All data according VDE 53, IEC6 34 dsg74l1_6_6_69_b Revision B Overload 5.8

Inverse current I2/IN [pu] Invers-Strom Nenndaten / nominal data Rating S N : 127 kva p.f..8 Bemessungsleistung Leistungsfaktor cos j: Nominal voltage U N :.69 kv Nominal current I N : 163 A Bemessungsspannung Bemessungsstrom Frequency f N : 6 Hz Speed n: 12 min -1 Frequenz Protection: Schutzart 3 IP23 Drehzahl Inverse current or unbalanced negative sequence current 2.5 Failure operation / im Fehlerfall (I 2 /I N ) 2 x t = 2 IEC634-1 (I 2 /IN) 2 x t = 4 NEMA MG1 Continuous operation / im Dauerbetrieb I 2 /I N =,8 IEC634-1 I 2 /IN =,1 NEMA MG1 2 1.5 1.5 1 1 1 1, 1, Time [s] Zeit Remarks / Notizen: All data according IEC 634-1, NEMA MG1 dsg74l1_6_6_69_b Revision B Inverse current 5.9

Real power P [p.u] TYPE Technische Daten selbstregelnden Drehstrom-Synchrongenerator technical data for self regulating three phase alternator Projekt: Order Nr.: Capability (P-Q) Diagram 1.2 1.1 1.9.8.7.6.5.4.3.2.1-1.2-1.1-1 -.9 -.8 -.7 -.6 -.5 -.4 -.3 -.2 -.1.1.2.3.4.5.6.7.8.9 1 1.1 1.2 Underexcited Reactive power Q [p.u] Overexcited Underexcited Overexcited Rotor thermal Limit Stability Limit Prime Mover Limit excitation circle cos phi =,95 cos phi =,9 cos phi =,8 cos phi =,7 cos phi =,6 cos phi =,4 cos phi =,2 cos phi =,1 Cummins Generator Technologies Datum / date : 3/1/214 dsg74l1_6_6_69_b Revision B PQ-Diagramm

Stator current I s /I N [p.u.] TYPE Projekt: Technische Daten selbstregelnden Drehstrom-Synchrongenerator technical data for self regulating three phase alternator Order Nr.: 1.3 1.2 V-Curve 1.1 1.9.8.7.6.5.4.3.2.1.4.5.6.7.8.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 Underexcited Excitation current I f /I f [p.u.] Overexcited Pn,75 Pn,5 Pn,25 Pn cos phi = cos phi =1 Stator winding thermal Limit Stable Limit Excitation winding thermal Limit cos phi =,8 cos phi =,9 Cummins Generator Technologies Datum / date : 3/1/214 dsg74l1_6_6_69_b Revision B V-Curve

Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 2/1/14 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dsg74l1_6_6_69_a48m965 Object data: Site: Prime Mover: Application: Stationary Power Plant Manufacturer: Generator data: Generator: Poles: 6 Standards: IEC 634 Rated power: 127 kva 116 kwe 165 kwm Power factor:.8 Power at pf 1, 13 kva 13 kwe 165 kwm Rated voltage:.69 kv Speed: 12 1/min Frequency: 6 Hz Voltage range / frequency range: Rated current: 162.7 A Zone A according IEC 634-1 (du = +/-5%, df = +/-2%) Winding pitch: ca. 5/6 Insulation class: Stator: Class H Rotor: Class H Temperature rise: H Ambient temperature: 4 C Environment: Standard environment Site altitude: 1 m Enclosure: IP23 Filter: Cooling: IC 1 - Open-circuit ventilation Coolant: Ambient Air Temperature Coolant: 4 C Temperature Air inlet generator: 4 C Cooling air vol.: 1.9 m³/s Cooling water quantity: n/a Moment of inertia (I): 47.8 kgm² Weight: 3575 Kg Losses (environment): Losses (cooling): Wires: 4 terminals, starpoint connected in terminal box Operation mode: Single mode Regulators: Voltage regulator: DECS 1 49 KW n/a Electrical data: (acc. IEC) Efficiencies: 11% 1% 75% 5% 25% Power factor.8 95,16 95,39 95,67 95,55 93,71 Power factor.9 95,87 96,7 96,22 95,96 93,97 Power factor 1. 96,58 96,74 96,76 96,36 94,22 Reactances and time constants unsaturated saturated unsaturated saturated x d 2.8 1.88 p.u. x q.97.95 p.u. T d' 2.3388 s T d''.2422 s x d'.245.245 p.u. x q'.97.95 p.u. T d'.28 s T q'.2274 s x d''.127.115 p.u. x q''.139.139 p.u. T d''.1137 s T q''.15869 s x 2.139.126 p.u. x.47.43 p.u. T a.2363 s T q'.2274 s x 1s n.a..69 p.u. T q''.2274 s Short circuit ratio saturated:.53 Z n.375 Ohm Short circuit data: Initial short circuit current (3-phase): I k'' 9241 A Max. peak current (3-phase): I S 23524 A Sustained short circuit current: I k 3188 A Minimum 3 x rated current for max.1 s Initial short circuit torque: M k2 114.2 knm M k3 68.5 knm Max. faulty synchron moment: M f 245.5 knm Rated kva torque: M SN 1.11 knm Rated torque M N 8.9 knm Shaft torque MSh 8.48 knm Load application: max. load application: 778 kva(corresponds to 61,23 % from 127 kva) for Power factor.4 15% transient voltage drop Remarks: Power: 127 kva Power factor:.8 transient voltage drop: -19.7 %

Eta [%] Alternator : Rated output [kva] 127 Rated power factor:.8 Rated voltage [kv]:.69 Rated frequency [Hz] 6 Rated speed [rpm] 12 Wirkungsgrad-Kennlinie - Efficiency Curve 98. 97. 96. 95. 94. 93. 92. 91. PF=,8 PF=,9 PF=1 Load [% rated load] 9. 2 3 4 5 6 7 8 9 1 11 dsg74l1_6_6_69_b Revision B Efficiency 5.2

Transient voltage drop / Transient voltage rise [%] Alternator : Rated output [kva] 127 Rated power factor:.8 Rated voltage [kv]:.69 Rated frequency [Hz] 6 Rated speed [rpm] 12 Transient Voltage rise or drop for sudden load removal or application 3 2 1 1 p.f.,8 p.f.,4 p.f.,1 p.f. -1-2 -3-4 Sudden load removal / sudden load application in [%] of rated load depending from power factor -1-75 -5-25 25 5 75 1 125 dsg74l1_6_6_69_b Revision B Voltage drop-rise 5.3

Mk/MSN in p.u. Alternator : Rated output [kva] 127 Rated power factor:.8 Rated voltage [kv]:.69 Rated frequency [Hz] 6 Rated speed [rpm] 12 MSN related to kva: 1.11 KNm 15 Kurzschlußmomenten-Verlauf 2-poliger KS Short circuit torque at 2-phase SC 1 5 1 1 19 28 37 46 55 64 73 82 91 1 19 118 127 136 145 154 163 172 181 19 199 28 217 226 235 244 253 262 271 28 289 298-5 -1-15 t / ms dsg74l1_6_6_69_b Revision B MK2 5.5

Kurzschlussstrom Ik3phasig / IN [p.u.] Short-circuit current Ik3phase / IN [ p.u. ] Nenndaten / nominal data Leistung S N : 127 kva cos j:.8 Rating p.f. Spannung U N :.69 kv Strom I N : 163 A Voltage Current Frequenz f: 6 Hz Drehzahl n: 1,2 min -1 Frequency Speed Schutzart IP23 Protection Stosskurzschluss-Strom, 3-phasig, asymmetrisch / Sudden short circuit current, 3-phase, asymmetrical 2. 15. 1. 5.. -5. -1..1.2.3.4.5 Zeit [sec.] Time Notizen / remarks: Maximum asymmetric peak value I speak = 17851 A or 16.8 p.u. Alle Angaben gemäß VDE 53, IEC6 34 All data according VDE 53, IEC6 34 dsg74l1_6_6_69_b Revision B IKasym3-5.7

Strom I 1 /I N [p.u.] Current Nenndaten / nominal data Leistung S N : 127 kva cos j:.8 Rating p.f. Spannung U N :.69 kv Strom I N : 163 A Voltage Current Frequenz f: 6 Hz Drehzahl n: 12 min -1 Frequency Speed Schutzart IP23 Protection 5. Überlast Kennlinie Overload capability 4.5 4. 3.5 3. 2.5 2. 1.5 1..5. 1 1 1 1 Zeit [s] 1 Time Notizen / remarks: Strom / Zeit Kriterien: ( I / I N ) 2 *t =45s Current/time characteristics: 1,5*I N for 3 s 1,1*I N for 1 h in 6h Alle Angaben gemäß VDE 53, IEC6 34 All data according VDE 53, IEC6 34 dsg74l1_6_6_69_b Revision B Overload 5.8

Inverse current I2/IN [pu] Invers-Strom Nenndaten / nominal data Rating S N : 127 kva p.f..8 Bemessungsleistung Leistungsfaktor cos j: Nominal voltage U N :.69 kv Nominal current I N : 163 A Bemessungsspannung Bemessungsstrom Frequency f N : 6 Hz Speed n: 12 min -1 Frequenz Protection: Schutzart 3 IP23 Drehzahl Inverse current or unbalanced negative sequence current 2.5 Failure operation / im Fehlerfall (I 2 /I N ) 2 x t = 2 IEC634-1 (I 2 /IN) 2 x t = 4 NEMA MG1 Continuous operation / im Dauerbetrieb I 2 /I N =,8 IEC634-1 I 2 /IN =,1 NEMA MG1 2 1.5 1.5 1 1 1 1, 1, Time [s] Zeit Remarks / Notizen: All data according IEC 634-1, NEMA MG1 dsg74l1_6_6_69_b Revision B Inverse current 5.9

Real power P [p.u] TYPE Technische Daten selbstregelnden Drehstrom-Synchrongenerator technical data for self regulating three phase alternator Projekt: Order Nr.: Capability (P-Q) Diagram 1.2 1.1 1.9.8.7.6.5.4.3.2.1-1.2-1.1-1 -.9 -.8 -.7 -.6 -.5 -.4 -.3 -.2 -.1.1.2.3.4.5.6.7.8.9 1 1.1 1.2 Underexcited Reactive power Q [p.u] Overexcited Underexcited Overexcited Rotor thermal Limit Stability Limit Prime Mover Limit excitation circle cos phi =,95 cos phi =,9 cos phi =,8 cos phi =,7 cos phi =,6 cos phi =,4 cos phi =,2 cos phi =,1 Cummins Generator Technologies Datum / date : 3/1/214 dsg74l1_6_6_69_b Revision B PQ-Diagramm

Stator current I s /I N [p.u.] TYPE Projekt: Technische Daten selbstregelnden Drehstrom-Synchrongenerator technical data for self regulating three phase alternator Order Nr.: 1.3 1.2 V-Curve 1.1 1.9.8.7.6.5.4.3.2.1.4.5.6.7.8.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 Underexcited Excitation current I f /I f [p.u.] Overexcited Pn,75 Pn,5 Pn,25 Pn cos phi = cos phi =1 Stator winding thermal Limit Stable Limit Excitation winding thermal Limit cos phi =,8 cos phi =,9 Cummins Generator Technologies Datum / date : 3/1/214 dsg74l1_6_6_69_b Revision B V-Curve