Distance Determination between the MINOS Detectors for TOF Measurements. Dr. Virgil Bocean Alignment & Metrology Department Fermilab

Similar documents
STATUS REPORT ON THE GEODETIC AND ALIGNMENT EFFORTS FOR THE NUMI PROJECT AT FERMILAB

Status Report on the Survey and Alignment Activities at Fermilab

The CNGS neutrino beam

The Search for Neutrino-Antineutrino Mixing Resulting from Lorentz Invariance Violation using neutrino interactions in MINOS

Neutrinos & the MINOS Experiment

The First Results of K2K long-baseline Neutrino Oscillation Experiment

Long Baseline Neutrino Experiments

EE565:Mobile Robotics Lecture 6

Dead Reckoning navigation (DR navigation)

GISC3325 Spring 2011 Final Exam

Long Baseline Neutrinos

BNL Very Long Baseline Neutrino Oscillation Expt.

Neutrino-Nucleus Scattering at MINERvA

The Alignment Concept For The Fermilab Recycler Ring Using Permanent Magnets

New Results from the MINOS Experiment

Anti-fiducial Muons in MINOS. Matthew Strait. University of Minnesota for the MINOS collaboration

Latest results from MINOS

An Introduction to Modern Particle Physics. Mark Thomson University of Cambridge

Survey and Alignment of the J-PARC

MINOS. Physics Program and Construction Status. Karol Lang The University of Texas at Austin. YITP: Neutrinos and Implications for Physics Beyond

Today: Part I: Neutrino oscillations: beam experiments. Part II: Next tutorials: making distributions with histograms and ntuples

From Illinois to Minnesota in 1/400 of a second

Town of Chino Valley. Survey Control Network Report. mgfneerhg mc N. Willow Creek Road Prescott AZ

NA62: Ultra-Rare Kaon Decays

The T2K experiment Results and Perspectives. PPC2017 Corpus Christi Mai 2017 Michel Gonin On behalf of the T2K collaboration

The Multiple Muon Charge Ratio in MINOS Far Detector

PoS(NEUTEL2015)037. The NOvA Experiment. G. Pawloski University of Minnesota Minneapolis, Minnesota 55455, USA

SURVEY AND ALIGNMENT FOR THE SYNCHROTRON LIGHT SOURCE ELETTRA

MICE: The Trackers and Magnets

Experimental results on the atmospheric muon charge ratio

METROLOGY AND SURVEYING AT CERN : RECENT NEWS AND FACTS

VT State Plane. Daniel J. Martin National Geodetic Survey VT Geodetic Advisor. VSLS Conference Rutland VT April 11, 2008

Measurement of the neutrino velocity with the OPERA detector in the CNGS beam

Atmospheric Neutrinos MINOS MINOS Far Detector Type of Atmospheric Neutrinos at MINOS Two MINOS Atmospheric Analyses.

Detecting ν τ appearance in the spectra of quasielastic CC events

Survey and Alignment of the Fermilab Electron Cooling System

New Results for ν µ ν e oscillations in MINOS

LBNF Neutrino Beam. James Strait Fermi National Accelerator Laboratory P.O. Box 500, Batavia, IL , USA. on behalf of the LBNF/DUNE Team

Explorations of Neutrino Flux from the NuMI Beam at Different Positions From the Beam Axis

First neutrino beam and cosmic tracks. GDR neutrino

The National Spatial Reference System of the Future

Locating and supervising relief forces in buildings without the use of infrastructure

Analysis and Evaluation of the CERN Reference Systems

Neutrino interaction systematic errors in MINOS and NOvA

TECHNIQUES USED IN THE ALIGNMENT OF TJNAF S ACCELERATORS AND EXPERIMENTAL HALLS*

Longbase Neutrino Physics. Neil McCauley University of Liverpool Birmingham February 2013

Sensors for mobile robots

MINOS Neutrino Flux. Using NuMI Muon Monitors for calculating flux for use in cross-section calculations. D. Jason Koskinen

A method for detecting ν τ appearance in the spectra of quasielastic CC events

MINOS Oscillation Results from The First Year of NuMI Beam Operation

Arrow Brasil. Rodrigo Rodrigues Field Application Engineer F: Date: 30/01/2014 TM 2

Accelerator Neutrino Experiments News from Neutrino 2010 Athens

Fundamentals of High Accuracy Inertial Navigation Averil B. Chatfield Table of Contents

MINOS experiment at Fermilab

THE GSI FUTURE PROJECT: AN INTERNATIONAL ACCELERATOR FACILITY FOR BEAMS OF IONS AND ANTIPROTONS

Neutrino mixing II. Can ν e ν µ ν τ? If this happens:

Tau-neutrino production study in 400 GeV proton interactions

David Martin High Precision Beamline Alignment at the ESRF IWAA, Grenoble 3-7 October 2016

Inertial Odometry on Handheld Smartphones

Hadron Production Experiments and Neutrino Beams

arxiv: v3 [hep-ex] 24 Nov 2015

Study of ν τ production by measuring D s τ events in 400 GeV proton interactions: Test of lepton universality in neutrino charged-current interactions

From Here to a Neutrino Factory: Neutrino Oscillations Now and Again

Chapter 2 The MINOS and MINOS+ Experiments

Fundamentals of attitude Estimation

Review of Accelerator Alignment

MINOS Flux Determination

Accelerator neutrino experiments

PoS(NOW2016)003. T2K oscillation results. Lorenzo Magaletti. INFN Sezione di Bari

The NOνA Experiment and the Future of Neutrino Oscillations

Latest Results from the OPERA Experiment (and new Charge Reconstruction)

First MINOS Results from the NuMI Beam

THE DISTANCE FROM CERN TO LNGS

Douglas Michael California Institute of Technology RPIA 2002 KEK, Oct. 29, 2002

Timing in the NOvA detectors with atomic clock based time transfers between Fermilab, the Soudan mine and the NOvA Far detector

SURVEYING AND MAPPING, INC. COORDINATE DATA SHEET JOB: CITY OF DECATUR CLIENT: CITY OF DECATUR SAM JOB#:

Studies of NOνA neutrino flux with NDOS

PoS(EPS-HEP2015)522. The status of MICE Step IV

arxiv: v1 [physics.ins-det] 5 Nov 2015

Particle Identification Algorithms for the Medium Energy ( GeV) MINERνA Test Beam Experiment

NATRF 2022 AND LDP OCTOBER 11, 2017

Cosmic Ray Physics with the MINOS Detectors. Jeff de Jong Oxford Particle Seminar Feb 24, 2009

Cosmic Muons Induced EM Shower in NOνA

Perspective from Fermilab NRC-DUSEL, December 15, 2010

Neutrino Oscillations

CS491/691: Introduction to Aerial Robotics

The First Large Application of MPPC: T2K Neutrino Beam Monitor INGRID

1 BROOKHAVEN SCIENCE ASSOCIATES

Sensing Rotation with Light: From Fiber Optic Gyroscope to Exceptional Points

Charged Current Inclusive Scattering in MINERnA

Latest News On NuMI Beam Simulation

A data summary file structure and analysis tools for neutrino oscillation analysis at the NOvA experiment

BNL Very Long Baseline Neutrino Oscillation Expt.

STREAM OF DARK MATTER AS A POSSIBLE CAUSE OF THE OPERA CLOCKS SYNCHRONIZATION SIGNALS DELAY

PoS(HEP2005)177. Status of the OPERA experiment. Francesco Di Capua. Universita Federico II and INFN.

Emittance Measurement in the Muon Ionization Cooling Experiment

THE SPEAR3 UPGRADE PROJECT AT SLAC *

Astrophysical Nucleosynthesis

The Fiber Optic Gyroscope a SAGNAC Interferometer for Inertial Sensor Applications

Integration of a strapdown gravimeter system in an Autonomous Underwater Vehicle

Transcription:

Distance Determination between the MINOS Detectors for TOF Measurements Dr. Virgil Bocean Alignment & Metrology Department Fermilab 1 1

Introduction Part of the neutrino research program at Fermilab is the search for non-zero neutrino mass Looks for neutrino oscillations (ν µ ν τ ) or (ν µ ν e ) NuMI (Neutrinos at the Main Injector) has built a new particle beamline capable of directing a pure beam of muon neutrinos MINOS (Main Injector Neutrino Oscillation Search) experiment uses NuMI beam to search with significantly greater sensitivity for neutrino oscillations utilizing two detectors: Near Detector - located close to the neutrino source (1 km away from the target) Far Detector - 735 km away, in a deep underground mine in northern Minnesota, 710 m below the surface Recent results on neutrino velocity measured with the Opera detector and CNGS beam raised questions about the neutrinos possibly traveling faster than light. As a result, this generated increased interest in determining the precise distance for verification of the neutrino time-of-flight (TOF) The distance for NuMI TOF measurements was computed between the front (most upstream) planes of the Near and Far detectors (the events timestamp was reduced to those planes) A rigorous solution for computing the Euclidian distance between the two detectors along the beam path requires precise knowledge of the absolute positions of those detectors in space 2

NuMI Beamline From Fermilab to Soudan, MN 735 km 3

NuMI Tunnels and Halls 4

Alignment Tolerances (1σ) IWAA2010 September 13-17, 2010 DESY, Germany Primary proton beam centered ± 12 m at the far detector (± 0.016 mrad = 3.4 arc sec) Neutrino beam centered ± 75 m at the far detector ± 0.102 mrad = 21 arc sec) NuMI is mainly sensitive to final primary beam trajectory : primary beamline components, Target and Horn alignment => relative positions ±0.35 mm Beam position at target Beam angle at target Target position - each end Horn 1 position - each end Horn 2 position - each end Decay pipe position Downstream Hadron monior Muon Monitors Near Detector Far Detector ± 0.45 mm ± 0.7 mrad ± 0.5 mm ± 0.5 mm ± 0.5 mm ± 20 mm ± 25 mm ± 25 mm ± 25 mm ± 12 m 5

Geodetic determination of global positions The correct aiming of the beam is of great importance for the experiment Requires a rather exact knowledge of the geodetic orientation parameters of the beam => absolute & relative positions of the target (Fermilab) and the far detector (Soudan) at the global level Two steps procedure: 1. FNAL/Soudan long GPS baseline measurements tie the surface control to the National Geodetic Survey s Continuously Operating Reference Station (CORS) precision GPS geodetic network vector known to better than 1 cm horizontally and vertically solution in International Terrestrial Reference Frame of 2000 (ITRF00) reference system => then transformed in the national North American Datum of 1983 (NAD 83) system NGS will provide an independent solution (excellent agreement within 1 cm) 2. Inertial system survey through 713 m shaft tied the the 27 th level of the mine to surface geodetic control University of Calgary Department of Geomatics Engineering contracted to perform the survey with an rms be below 1 meter A posteriori coordinates transfer accuracies : latitude 0.48 m, longitude 0.20 m and height 0.23 m 6

Geodetic determination of global positions Results Ellipses of Error in x, y plane Errors in Height Rms of residuals @ 95% confidence level Long/Lat = 2 mm Height = 6 mm Ellipses of Error @ 95% confidence level (bar scale tick = 1 mm) NuMI global position accuracy is shown 7

Comparison between coordinates and geodetic parameters Coordinates in Local Geodetic System at 66589 FROM TO n e up n e up Comment (m) (m) (m) (m) (m) (m) 66589_93 SHAFT_93 671107.806-297423.720-42175.340 0.725-0.296-0.050 NGS NAD83 tie 66589_93 SHAFT_98 671108.303-297424.045-42175.408 0.229 0.029 0.018 GPS differential 66589_CORS Fermi SHAFT_CORS Fermi 671108.540-297424.003-42175.396-0.008-0.013 0.006 CORS calc Fermi 66589_CORS NGS SHAFT_CORS NGS 671108.532-297424.016-42175.390 0.000 0.000 0.000 CORS calc NGS Geodetic parameters for beam orientation FROM TO Normal Sect Az Az Vertical Angle VA Distance D (d-m-s) ( sec) (d-m-s) ( sec) (m) ( m) 66589_94 SHAFT_94 336-05-52.35714 0.01079 3-17-17.88121 0.00122 735272.273 0.785 66589_94 SHAFT_98 336-05-52.33031 0.03762 3-17-17.89081-0.00838 735272.862 0.196 66589_CORS Fermi SHAFT_CORS Fermi 336-05-52.36793-0.00335 3-17-17.88412-0.00169 735273.061-0.003 66589_CORS NGS SHAFT_CORS NGS 336-05-52.36458 0 3-17-17.88243 0 735273.058 0.000 8

Underground coordinate transfer at Soudan The weakest link! Setup of the IMU in the cage and the coordinate transfer performed by a total station at the surface HG Honeywell 2001 Inertial Navigation System (INS) unit: o o o composed of 3 accelerometers and 3 gyroscopes output specific forces and respective angular velocities from the orthogonal sensor triads outputs used in a dead-reckoning method which after initialization provides three dimensional geodetic coordinates at a high data rate Performance Parameter Class II 1.0 nmi./h gyro bias uncertainty (deg/h) 0.003 gyro random noise (deg/ h) 0.001 gyro scale-factor uncertainty (ppm) 1 gyro alignment uncertainty ( arc sec)? accelerometer bias uncertainty (mgal) 10-25 accel. scale-factor uncertainty (ppm) 50 accelerometer alignment uncertainty (sec) 5 accelerometer bias trending (mgal/sec)? σ pos 0.5 m at ZUPTs every 3 min σ acceleration net bias < 50 mgal short term bias < 3 mgal The accuracy of the results depends of: o o the quality of the hardware, on the the method used to estimate systematic errors inherently present in the sensors Multiple determinations running the unit rigidly attached in the center of the elevator car Mapped the 710 m deep access shaft by setting the inertial system at 1 second data collecting rate A posteriori coordinates transfer accuracies : latitude 0.48 m, longitude 0.20 m and height 0.23 m 9

Geodetic determination of global positions Geoid consideration Needed knowledge of the gravity vector at the origin (Fermilab) Previous study comparing a Local Geoid Model and NGS Geoid93 model Differences up to 5 mm (consistent with expected values) LBNE beam within 1.5 mm range of differences Geoid93 model (presently used) - sufficient to cover tolerance requirements Difference Local geoid model - Geoid93 5-6 Difference (mm) 6 5 4 3 2 1 0 LBNE Difference Local geoid model - Geoid93 in LATITUDE Main Injector 41 48 51 41 49 00 41 49 09 41 49 18 41 49 27 41 49 36 41 49 46 41 49 55 41 50 04 41 50 13 41 50 22 41 50 31 41 50 40 41 50 49 41 50 58 41 51 07 41 51 16 41 51 25 41 51 34 41 51 43 41 51 53 6 4-5 88 16 50 88 16 37 88 16 24 88 16 11 88 15 58 88 15 45 88 15 31 88 15 18 88 15 05 88 14 52 88 14 39 88 14 26 Longitude W 88 14 13 88 13 59 88 13 46 88 13 33 88 13 20 88 13 07 88 12 54 88 12 41 88 12 28 3-4 Difference (mm) 5 4 3 2 1 0 88 16 50 88 16 24 88 15 58 88 15 31 88 15 05 88 14 39 88 14 13 LBNE Longitude W 88 13 46 88 13 20 88 12 54 88 12 28 41 49 09 41 48 51 41 49 46 41 49 27 41 50 22 41 50 04 41 51 53 41 51 34 41 51 16 41 50 58 41 50 40 2-3 1-2 0-1 Latitude N Difference (mm) 6 5 4 3 2 1 0 41 48 51 Main Injector 41 49 00 41 49 09 41 49 18 41 49 27 41 49 36 Difference Local geoid model - Geoid93 in LONGITUDE 41 49 46 41 49 55 41 50 04 41 50 13 LBNE 41 50 22 41 50 31 Latitude N 41 50 40 41 50 49 41 50 58 41 51 07 41 51 16 41 51 25 41 51 34 41 51 43 41 51 53 88 16 50 88 16 37 88 16 24 88 16 11 88 15 58 88 15 45 88 15 31 88 15 18 88 15 05 88 14 52 88 14 39 88 14 26 88 14 13 88 13 59 88 13 46 88 13 33 88 13 20 88 13 07 88 12 54 88 12 41 88 12 28 10

Primary geodetic network at Fermilab N NuMI Provides the basis for construction surveys and for the precision underground control networks existing Fermilab control network (accuracy < 2 mm @ 95% confidence level) horizontal geodetic datum = North American Datum of 1983 (NAD 83) based on the reference ellipsoid Geodetic Reference System 1980 (GRS-80) vertical datum = North American Vertical Datum of 1988 (NAVD 88) geoid model = NGS model Geoid93 includes 3 monuments tied through CORS to Soudan add 6 new geodetic monuments (densification around access shafts) ~400 GPS, terrestrial and astronomic observations error ellipses in millimeter range (@ 95% confidence level) 11

Primary surface geodetic network at Fermilab Results Ellipses of Error in x, y plane Errors in Height Ellipses of Error @ 95% confidence level (bar scale tick = 1 mm) Histogram of standardized residuals (bar scale tick = 1 σ) NuMI surface geodetic network accuracy is shown 12

Precision underground control networks Provided vertical sight risers for transferring coordinates from the surface to the underground (better and more efficient for controlling error propagation in a weak geometry tunnel network) Network simulations => 7 locations for transferring coordinates from the surface (3 vertical sight risers, 2 tunnel Access Shafts and 2 Exhaust Air Vent pipes) Due to the increased depth of the tunnel, designed adequate procedure for precision transfer of surface coordinates underground 13

Precision underground control networks Built to support the alignment of Primary Beam components, the Target and focusing Horns and the installation of the two Near and Far detectors Components alignment scope: - Primary beam magnets and instrumentation aligned to ±0.25 mm - Target station components aligned to ±0.5 mm - Detectors : determine the relative position of the scintillator modules with respect to each other and the detector structure within ±5 mm additionally: provided feedback on plane-to-plane movements (lateral drifts, pitch, and warping of the planes) Error budget networks requirements ±0.50 mm at 95% confidence level Primary Beam network => continuous from MI-60 to the downstream end of the Target Hall + two separate Near and Far detector networks Constraints at underground transfer points: sight risers, access shafts and aer exhaust vents Network type: Laser Tracker processed as trilateration Additional measurements to study and control network behaviour Final primary beam trajectory azimuth confirmed by first order Astronomical Azimuth at 0.004 mrad (0.74 arc sec) with s=±0.001 mrad (0.21 arc sec) Detectors azimuth confirmed through precision Gyro azimuth to < 0.010 mrad (2 src sec) 14

NuMI primary beam underground control network Results Errors Ellipses ±0.45 mm and histogram of residuals σ=±0.110 mm at 95% confidence level ZY Error Ellipses 95% Confidence Level (2.45σ) XY Error Ellipses 95% Confidence Level (2.45σ) 0.50 MI Stub Carrier Pre-Tgt Tgt Hall 0.50 MI Stub Carrier Pre-Tgt Tgt Hall 0.45 0.45 Ellipses Semi Axes [m 0.40 0.35 0.30 0.25 0.20 0.15 0.10 Semi-Major Axis [mm] Ellipses Semi Axes [m 0.40 0.35 0.30 0.25 0.20 0.15 0.10 Semi-Major Axis [mm] 0.05 0.05 0.00-350 -300-250 -200-150 -100-50 0 50 100 Station [m] 0.00-350 -300-250 -200-150 -100-50 0 50 100 Station [m] 5000 4000 Residuals Gaussian Fit Data: NuMI Tunnel Network (Stub+Pre Target+Target Hall) Model: Gauss Equation: y=y0 + (A/(w*sqrt(PI/2)))*exp(-2*((x-xc)/w)^2) Weighting: y No weighting Frequency 3000 2000 1000 Chi^2/DoF = 6.08502 R^2 = 0.99442 count 22976 σ 0.110 mm y0 72.79747 ±24.34984 mm xc 0.02451 ±0.142 mm w 0.15296 ±0.003 mm A 1035.41393 ±19.33207 mm NuMI underground network accuracy is shown 0-0.330-0.220-0.110 0.000 0.110 0.220 0.330 Residuals (mm) (bar scale tick = 1 σ) 15

MINOS detectors underground control networks Results measured with the Laser Tracker and processed as trilateration additional measurements to study/control network behaviour and for confirmation: Mekometer distances, angles, gyro-azimuths and precision levelling network results: relative errors below ±0.35 mm at 95% confidence level MINOS Far Detector Hall Network Histogram of standardized residuals (bar scale tick = 1 σ) MINOS Near Detector Hall Network Histogram of standardized residuals (bar scale tick = 1 σ) 3000 Residuals (mm) Gaussian Fit 400 Residuals (mm) Gaussian Fit Frequency 2500 2000 1500 1000 Count = 13187 σ = 0.120 mm Center = 0.022 mm Frequency 350 300 250 200 150 Count = 1688 σ = 0.077 mm Center = 0.010 mm 500 100 50 0-0.36-0.24-0.12 0.00 0.12 0.24 0.36 Residuals [mm] MINOS underground network accuracy is shown 0-0.154-0.077 0.000 0.077 0.154 Residuals [mm] 16

MINOS detectors installation MINOS far detector: at Soudan mine 5.4 kton tracking calorimeter 486 planes (steel and scintillator) 8 m wide, octagonal shape two super modules surveyed with the indoor GPS system: a posteriori accuracy sx =±2 mm, sy =±3.5 mm, σz (along the detector) =±6.8 mm MINOS near detector: at Fermilab 980 tons (smaller version) 282 planes (steel and scintillator) 3.8x4.8 m, squashed octagon reference for the far detector surveyed with the Laser Tracker: a posteriori accuracy σx, Y, Z (along the detector) =±1 mm 17

Surveying MINOS Far Detector with Indoor GPS (conceptual setup) 18

MINOS TOF distance summary The MINOS TOF distance from the front plane of the Near Detector to the front plane of the Far Detector: D = 734286.898 m±0.5 m In the error budget analysis, the accuracy of determining this distance is preponderantly being driven by the uncertainty of the Inertial Measurement System instrument used to tie the precise geodetic network on the surface and the underground control used to support the installation of the Far Detector. As reported by the contractor who performed the survey (The Department of Geomatics Engineering from the University of Calgary), the computed accuracies were 0.48 m, 0.20 m and 0.23 m in latitude, longitude and height, respectively, where the 0.48 m on latitude is dominant since the beam points almost North. 19

Backup slides 20