Bureau International des Poids et Mesures. Rapport BIPM -89/1

Similar documents
Experiment O-2. The Michelson Interferometer

ABSTRACT. The following values for the wavelength of the sodium doublet lines were calculated:

Michelson Interferometer

Optical Metrology and Sensing

Introduction. Procedure. In this experiment, you'll use the interferometer to EQUIPMENT NEEDED: Lens 18mm FL. Component holder.

Probing the orbital angular momentum of light with a multipoint interferometer

Experiment 8 Michelson Interferometer

Comparative Measurement in Speckle Interferometry using Fourier Transform

Metrology and Sensing

The Michelson Interferometer

Experiment 2: The Speed of Light

Interference- Michelson Interferometer. Interference lecture by Dr. T.Vishwam

Measurements in Optics for Civil Engineers

5. LIGHT MICROSCOPY Abbe s theory of imaging

Coherence and width of spectral lines with Michelson interferometer

LIGO I mirror scattering loss by non smooth surface structure

Absolute length measurement using multiple-wavelength phase-stepping interferometry

Experiment 6: Interferometers

Interferometers. PART 1: Michelson Interferometer The Michelson interferometer is one of the most useful of all optical instru

Optical Interferometry

The Michelson Interferometer as a Device for Measuring the Wavelength of a Helium-Neon Laser

Metrology and Sensing

Introduction to FT-IR Spectroscopy

Laser Speckle and Applications in Optics

PS210 - Optical Techniques. Section VI

Speed of Light in Air

ROTATIONAL SHEARING INTERFEROMATER. Introduction. The Interferometer. L. Yeswanth, Optics Group, IIA, Bangalore

10. OPTICAL COHERENCE TOMOGRAPHY

Low Coherence Vibration Insensitive Fizeau Interferometer

PRINCIPLES OF PHYSICAL OPTICS

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Particle-Wave Duality and Which-Way Information

Chapter 5. Past and Proposed Experiments Detecting Absolute Motion

Measurments with Michelson interferometers

THE ZEEMAN EFFECT PHYSICS 359E

8. The Michelson Interferometer

PHYS 229: Experiment 1 Expansion Coefficients of Copper and Invar Bars Through Laser Interferometry

Fabry-Perot Interferometer for atmospheric monitoring useful for EAS detection E.Fokitis 1, K. Patrinos 1, Z. Nikitaki 1

Michelson Interferometry and Measurement of the Sodium Doublet Splitting

COMPUTER GENERATED HOLOGRAMS Optical Sciences 627 W.J. Dallas (Monday, August 23, 2004, 12:14 PM)

iprom Optical Interferometry Prof. Dr. -Ing. Rainer Tutsch Institut für Produktionsmesstechnik IPROM Technische Universität Braunschweig

Light as a Transverse Wave.

Fourier Transform Spectrograph Development Project

MEMS Metrology. Prof. Tianhong Cui ME 8254

Simulation of laser propagation in plasma chamber including nonlinearities by utilization of VirtualLab 5 software

International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July ISSN

The science of light. P. Ewart

THE MICHELSON INTERFEROMETER Intermediate ( first part) to Advanced (latter parts)

Light as Wave Motion p. 1 Huygens' Ideas p. 2 Newton's Ideas p. 8 Complex Numbers p. 10 Simple Harmonic Motion p. 11 Polarized Waves in a Stretched

Computer aided measurement of biomechanical characteristics of cadaverous lumbar spines

Figure measurement of a large optical flat with a Fizeau interferometer and stitching technique

5 TH ERMAL GRADIENT INTERFEROMETRIC MEASUREMENT

An Interferometric Force Probe for Thruster Plume Diagnostics

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

LASER TRAPPING MICRO-PROBE FOR NANO-CMM

INTERFEROMETERS. There are 4 principal types of measurements that can be made with this type of interferometer.

Path Entanglement. Liat Dovrat. Quantum Optics Seminar

Fringe shifts in multiple-beam Fizeau interferometry

Optical Tweezers. The Useful Micro-Manipulation Tool in Research

Optics.

Chapter 10. Interference of Light

Using dispersion-induced group delay to solve the integer ambiguity problem: a theoretical analysis

MODERN INTERFEROMETRY

Supporting Online Material for

2.71. Final examination. 3 hours (9am 12 noon) Total pages: 7 (seven) PLEASE DO NOT TURN OVER UNTIL EXAM STARTS PLEASE RETURN THIS BOOKLET

Renewal of the gage-block interferometer at INRIM

Optical Systems Program of Studies Version 1.0 April 2012

Speckle phenomenon and its potential for metrology

Constructive vs. destructive interference; Coherent vs. incoherent interference

Michelson Interferometer. crucial role in Einstein s development of the Special Theory of Relativity.

Homogeneity of optical glass

Standard Small Angle Generator Using Laser Interferometer

Interferometric determination of thermal expansion coefficient of piston/cylinder unit preliminary investigation

Speed Measurement by Optical Techniques. Lucas Thoennes

Thermal Imaging at Multiple Time Instants for Study of Self-Heating and ESD Phenomena

Strain Analysis by Digital Shearography on an Aluminium Plate with a Geometric Defect under Thermal Loading

Effect of piezoelectric transducer nonlinearity on phase shift interferometry

Wavefront Sensing using Polarization Shearing Interferometer. A report on the work done for my Ph.D. J.P.Lancelot

POLARIZATION OF LIGHT

Optical Shop Testing. Second Edition. Edited by DANIEL MALACARA. John Wiley & Sons, Inc. A Wiley-Interscience Publication

Low-coherence heterodyne photon correlation spectroscopy

Correction of Errors in Polarization Based Dynamic Phase Shifting Interferometers

A phase shifting interferometeric imaging ellipsometer

Recent progress in SR interferometer

Liquid refractometer based on immersion diffractometry

A faster, more accurate way of characterizing cube beamsplitters using the Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

1. Consider the biconvex thick lens shown in the figure below, made from transparent material with index n and thickness L.

LAB DEMONSTRATION OF INTERFEROMETRIC

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Dimension measurement. By Mr.Vuttichai Sittiarttakorn

LABORATORY WRITE-UP MICHELSON INTERFEROMETER LAB AUTHOR S NAME GOES HERE STUDENT NUMBER:

Machine Positioning Uncertainty with Laser Interferometer Feedback

Experiment 4. Michelson Interferometer. 4.1 Introduction. References

Imaging through Kolmogorov model of atmospheric turbulence for shearing interferometer wavefront sensor

Phase-conjugation of high power molecular C02 and CO lasers radiation inside their active medium

Research Article Noncontact Measurement for Radius of Curvature of Unpolished Lens

Metrology and Sensing

LASER APPLICATIONS XII. QPR No Academic Research Staff. Ezekiel. Prof. S. Graduate Students

CHAPTER 9 PERFORMANCE OF THE INTERFEROMETER

Transcription:

Bureau International des Poids et Mesures Rapport BIPM -89/1 Shape Measurements of Standard Length Scales Using Interferometry with Small Angles of Incidence by Lennart Robertsson Abstract An interferometric technique for surface shape measurements on standard line scales has been developed and tested. By using small angles of incidence for the laser light to the surface a variable sensitivity, practical dimensions on the interferograms and insensitivity to surface roughness can be obtained. Measurements on a 300 mm line scale are included as a demonstration. With the optical components used an accuracy in the surface determination of about 2.5 ~m was obtained.

1 INTRODUCTION The definition of length in tenns of propagation of electromagnetic waves allows for very accurate length standards, limited in principle only by the accuracy to which the frequency of the particular light sources are known at the time. More and more accurate frequency measurements and better laser systems will yield better and better standards without having to change the definition of the metre. The present best frequency determinations are around 10-10 in relative uncertainty (3 cr) [1],[2]. For the practical realization of the metre interferometric techniques are nonnally used and standard lengths are transferred in the form of line scales and end gauges, as can be expected, with a lower precision. To determine to what precision the calibration of line scales can be done a large international comparison of length scale measurements has been organized and reported recently by the BIPM [3]. It was concluded in this comparison that the reproducibility of length measurements was not as good as one could expect from individual instrumental perfonnance. The standard deviation of one laboratory with respect to the mean of the measurements of the length of a 1 m ruled material standard was found to be of the order of 10-7, in contrast to the corresponding estimated uncertainties given for the individual laboratories participating in the comparison, which were, in average, around 3.10-8 Hence, systematic errors exist which have been underestimated when calculating the uncertainties in the experimental data. Indications of a correlation between shape and'length was mentioned in reference [3]. The vertical deviation from a plane of the scale, given in one ofthe measurements [4], and deviations in the relative calibration for each decimetre line are both shown in Fig. 1. Relative calibration refers to the values of the deviations for each decimetre line from that of an ideal scale of 1 m and perfectly divided in 1000 mm lines. It can indeed be seen from the similarity of the structures of the curves that a correlation between these two quantities seems to exist. It can however not be concluded whether this correlation is due to the fact that the measured values directly are affected by the shape of the scale or if the lines actually are displaced. Such a correlated displacement could have occurred in the generation process of the lines if the technique to engrave the lines also was dependent on the scale shape. It is anyhow of interest to be able to monitor the surface shape of standard length scales to detect geometrical instabilities and gain control over factors causing such.

- 2- We present below an interferometric technique for the characterization of line scale surfaces, for long as well as for short scales. Similar techniques applied to different surfaces have been described earlier [5]. By using a projection of the surface to be measured, instead of the usual normal incidence of the laser light, several advantages can be obtained. This is described in the following section. Measurements on a 300 mm scale are included as a demonstration of the performance of this technique. 2 MEASURING PRINCIPLE The surface function, z (x, y), of a scale, here defined as the deviation from an average plane trough the surface, is from experience [3] expected to be in the range of some 10-50 ~m. Such measured deviations for the surface are the sum of two effects, the actual "straightness" and superimposed on it variations in thickness of the scale. This interval is in a practical working range for good mechanical probes. Unfortunately, such probes work with mechanical contact to the surface that is being measured. This is not to be recommended when measuring the front side of the scale since a metallic contact probe could give surface damages, and in worst case deform some engraved lines and thereby ruin the whole scale. It could however be used to measure the three remaining sides. A second drawback with mechanical probes is the unavoidable pressure exerted by the probe on the surface which, in principle, deforms the scale. This effect can however be estimated and adjusted so as to minimize the introduced errors. Alternatively, interferometric methods for surface measurements are known to be very useful tools, giving immediate and contactless surface contour information with a very high sensitivity. Unfortunately, the working range of interest here is at the upper limit of what is practical for an interferometric technique and is therefore not optimal. Furthermore, and much more serious, are the large dimensions of the surfaces to be covered making a straight forward interferometric measurement practically impossible. Realizing the advantage of interferometric techniques we have made a small variation of a Michelson interferometer so as to overcome the difficulties just mentioned. The schematics of the set up used here is shown in Fig. 2. One sees here a traditional Michelson interferometer but with an angle off-set for the returning beams in the interferometer. For the long arm of the interferometer the beam is reflected in the surface to be studied. The projection of the surface has to be covered by the aperture of the interferometer if an interferogram of the whole surface

- 3 - is to be obtained. The most important feature of this set up is that the laser beam, incident at a low angle to the surface, sees a projection of the surface and its irregularities. This gives the following advantages: * practical dimensions of the projections of the surface and the interferogram. * a reduced sensitivity to surface roughness which, makes possible measurements even on rough "non-mirror" surfaces i.e. all sides of the scale can be measured. Light under glancing incidence will experience a much reduced surface micro-roughness and hence a much less scatter will occur. * a reduced and variable sensitivity adaptable to the deviation expected. The sensitivity is scaled as sine of the angle, a, used, c.f. Fig. 2. This is of limited importance since with lower sensitivity a shorter projection is obtained in the recording media, giving a reduced number of fringes on a smaller surface, so as the fringe density in the interference pattern is kept constant. The phase function, S(x, y), observed in the interferometer depends on the surface function, z(x,y), as '1 _ 41tz(x,y). ( ) _ 41tz(x,y )1 S( x,y )-tl t- A. sm a - 'AL (1) where L and I are the true and projected lengths of the scale respectively, and a is the angle of incidence of the laser light. Tilt represents an arbitrary reference plane determined by the setting

-4- of the reference mirror. This effect is only indicated in eq. 1 and not later equations since it is eliminated in the data evaluation step by the fitting and subtraction of a plane to the surface function. For incidence at right angles this gives a fringe distance of 'Ai2 as expected. For an angle of incidence a we get the fringe distance 'Ai(2sin(a». This can be expressed as an effective wavelength A. A.cJf = ~( sm a ) = ALII (2). 2.1 Error estimation For the use in section 3.3 we already here derive some relations for the estimation of uncertainties in the determination of the surface function. Using eq. 1, one can, given the phase function, determine the surface function. To be able to estimate the accuracy in this determination let us differentiate eq. 1: (3). de is then the phase resolution in the evaluation of the interferograms. More difficult is to determine the error in the effective wavelength, da.cjf. In eq. 2 one can see that a direct measurement of a or a determination of the projected length gives the effective wavelength. Here we have deduced the projected length from the interferogram using the aperture of the interferometer as a reference length. Using the following notations, ~p - interferometer aperture on photograph ~a - true interferometer aperture lp - projected length on photo

- 5 - we can write, (4). with eq. 2 we then get by differentiating, (5). This relation has been used to estimate the errors of the effective wavelengths in Table 1. 3 EXPERIMENT 3.1 Set up The interferometric setupis depicted in Fig. 2. TheSIS nmlineofaar+laser, Lexel-85, was used as a light source. The laser worked in single mode to obtain a sufficiently long coherence length. A conventional beam expander, without spatial filter, with an aperture of 17 mm was used. The overall null interference pattern without any scale introduced in the interferometer is seen in Fig 3. Aberrations of 1-2 wavelengths are seen. This puts a limitation to the accuracy of the measurements since the components used not are of good interferometric quality. To minimize this effect we have subtracted this background from the final data. The long extension of the scale will give a projection reaching out of the depth of focus for the optical detection system giving phase ambiguities at the ends of the scale. To make this the correct way the interferogram should be recorded in a plane with an angle and position given by the lens and the position of the object, the scale. This showed to be impractical using the available equipment, and the photographic films were placed normal to the light reaching the detector position.

- 6-3.2 Measurements As a test of the measuring principle and set up, measurements on a 300 mm H-bar scale have been perfonned. In Figs. 4 a-c. interferograms are shown recorded on photographic films positioned in the plane of projection in the detection arm for a point on the middle of the scale. The most smooth and nice interference pattern was, as expected, obtained from the front surface of the scale, 4a. In figures 4b and 4c one can see that also the sides of the scale give with this technique interference patterns of good quality. An attempt to obtain interference fringes at nonnal incidence to the side surfaces gave no usable results. The ambiguity in the sign of the phase variations were resolved by observing the movements in the interference pattern when slightly moving the reference mirror. 3.3 Evaluation and results As was mentioned above the aperture of the interferometer is 17 mm, set by the beam expander. This diameter of the circular reference beam serve as a reference distance on the recorded interferograms, which can be used to determine the projected length of the scale, c.f. Fig. 4c. With the projected length and the true length (here 300 mm) known, the angle of incidence and the effective wavelength can be calculated using eq. 2. These values are collected in Table 1. For the recordings made here the effective wavelength were about 12 Jlm corresponding to a angle of incidence of some 2 deg. The estimated uncertainties in the effective wavelength, using eq. 5, and the value d~a=o.1 mm, are included in the parentheses in the fifth column in Table 1. Phase maps ofthe interference area were evaluated in a 11x11 matrix giving 121 data points. Since the phase function is evaluated in discrete points a numerical low pass filter step has been applied to filter out surface function frequencies contained under the Nyquist frequency. If the surface function does contain higher frequencies these will be lost in this step and a certain alaising will occur. For the purpose of demonstration we assume rapid changes in the surface function to be small and we will make no further considerations about such effects here in this report. The corresponding surface functions obtained using equation 1, the effective wavelength and the phase maps are shown in Figs. 5a-c.

-7- In Fig. 6a-c are shown profiles of the surface functions taken at the middle of the scale in the length direction. For these diagrams also the curved null surface, given in the interferometer, has been subtracted, giving more accurate data. One can see that the deviations are of the order of some tens of micrometers, as expected. The phase determination in the evaluation of the phase function can be made with an absolute error of de = 27t15 which then at each point give an maximum error of about 1 ~m using eq. 3. This is an effect of the limitations in manual evaluation. Electronic techniques would here improve the accuracy with at least a factor of ten. Furthermore, the uncertainties in the effective wavelengths, around 0.3 ~m, give for large values of e = 207t, a maximum error of about 1.5 ~m Thus the total maximum uncertainty, according to eq. 3, for the determination of the surface function is 2.5 ~m. 4 CONCLUSION It has been demonstrated that the technique using a projection of the studied surface indeed is a good way to determine the shape of standard scales. With the technique described here a measurement of the shape of the different sides of the scale can be made in some few minutes, provided a fixed set up and computerized data evaluation. The uncertainty in this measurement is limited by the manual evaluation of the interferogram and the determination of the effective wavelength to around 2.5 ~m. Shape measurements ought to be done on a regular basis; possibly every time the scale is calibrated to be able to make more firm conclusions in the case of unexpected values of the measured length. In principle this type of measurements could be done simultaneously with the length measurements (in our case inside the comparator chamber) to defmitely determine the shape in the position and environment where the accurate length measurement is made. For instance, effects like "bad holders",position instability, and alike could in this way be identified, at the same time as the surface function is determined and compared to earlier measurement to see if any geometrical change has occurred, possibly caused by improper handling routines. Several improvements of the set up described above can be made. Both the quality of the optics and size of the aperture in the interferometer should be improved. This would increase the working range and the accuracy. To further improve the dynamic range and to definitely resolve the phase ambiguities, a phase shifting technique would be well suited. Phase shifting

- 8 - interferometry for surface covering interferometers involve a large number of data processing and it is therefore almost necessary to use a computer. Digitalization of the interference pattern and transfer to a computer then gives better performance, result storage and presentation. September 1989

- 9 - REFERENCES [1] "Documents Concerning the New Definition of the Meter", Metrolo~ia. 19, 1984, pp. 163-177. [2] "The Continuity of the Meter: The Redefinition of the Meter and the Speed Of Visible Light", 1. of Res. of the National Bureau of Standards. 92, 1987, p. 11. [3] RAMON J., GIACOMO P. and CARRE P., International Comparison of Measurements of Line Scales 1976-1984, Metrolo~a. 24, 1987, pp. 187-194. [4] see reference [3], table 6a, data N 12. [5] ARCHBOLD E., BURCH J.M. and ENNOS A.E., I. Scir InstIum.. 44, 1967, pp. 489-494.

- 10- Table 1 Evaluation of effective wavelength for the three recordings 4a, 4b and 4c. Diameter photo Length photo Projected length Angle of incidence Effective wavelength I [mm] [mm] [mm] [deg] 125(1) 142(1) 130(1) 100(1) 100(1) 94(1) 13.6 12.0 12.3 2.60 2.29 2.35 11.34(27) 12.88(30) 12.55(30)

- 11 - FIGURE CAPTIONS Fig. 1. Fig. 2. Fig. 3. Fig.4a The dotted curve shows the deviation in height from a line crossing the two end points of the surface. The solid curve gives the relative calibration (see text) forthe ten decimetre lines. The interferometric set up. Null surface measured in the interferometer. A curved background is seen as a result of limitations in the optical components used. Photographic recording of the interference pattern of the front side of the scale. Fig.4b Photographic recording of the interference pattern of one side of the scale. Fig.4c Photographic recording of the interference pattern of the other side of the scale. Fig.5a Fig.5b Fig.5c Fig.6a Fig.6b Fig.6c Surface function corresponding to the interferogram in Fig. 4a. Surface function corresponding to the interferogram in Fig. 4b. Surface function corresponding to the interferogram in Fig. 4c. Profile of the surface function taken at the middle of the scale in the length direction. Front side. Profile of the surface function taken at the middle of the scale in the length direction. Side. Profile of the surface function taken at the middle of the scale in the length direction. Side.

1,000 r----------------------------..., 100 800 80 length height ---tr-- 600 400 200 "A... "',;... '"... " If'" \\ "A /,/ \ I I \,,," \\ / '.'tf" \ I I \ \ I \ //"~ \, \ \ 60 40 20 ", '" " o~--~~--~--~--~----~--~----~--~----~--~~o o 2 3 4 5 6 7 8 9 10 Decimetre line Fig. 1

Laser beam Mirror Scale ~ Beam [ Expander ~ # # # ~ i:-- # Beam Splitter ~ I I~ Lens Mirror Fig. 2

1,000._---------------------------. 100 length height 800 80 ---0--- 600 60 40 200 20 o~--~~--~-~-~~-~-~--~-~--~- ~o o 2 3 4 5 6 7 8 9 10 Decimetre line Fig. 1

, Laser beam Scale ~ Beam [ Expander 0 Beam Splitter ~ ~ J Mirror # # # # I Lens -..J Mirror Fig. 2

Fig. 3

Fig.4b

Fig.4a

Fig.4c

Fig. Sa

Fig.5b

Fig. Se

Height [JAm] ~r--------------------------------------------------, 40 30 20 10 o~----~--~----~--~--~----~--~--~----~-- ~ o 1 2 3 4 5 6 7 8 9 10 Decimetre line Fig.6a

Height [pm] 10r-------------------------------------------------, o (10) (20) (30) (~)~~--~--~----~--~--~----~--~--~----~--~~ o 1 2 3 4 5 6 7 8 9 10 Decimetre line Fig.6b

Height [pm] ~r-----------------------------------------------------~ 40 30 20 10 o~~--~----~--~----~--~----~--~----~--~----~~ o 1 2 3 4 5 6 7 8 9 10 Decimetre line Fig.6c