Fadei Komarov Alexander Kamyshan

Similar documents
= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

IN THE NAME OF ALLAH, THE MOST MERCIFUL AND COMPASSIONATE

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

X-Ray Radiation Channeling through Micro-Channel Plates: spectroscopy with a Synchrotron Radiation Beam

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

Quality Assurance. Purity control. Polycrystalline Ingots

188 L. Jakubowski and M.J. Sadowski temperature. Some examples of the registered X-ray images are shown in Fig.1. Figure 1. X-ray pinhole images from

COST MP0601 Short Wavelength Laboratory Sources

Interaction of Fast Highly Charged Ions with Insulating Straight and Tapered Glass Capillary Surfaces

AP5301/ Name the major parts of an optical microscope and state their functions.

Silver Thin Film Characterization

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

The scanning microbeam PIXE analysis facility at NIRS

Lecture 22 Ion Beam Techniques

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Secondary ion mass spectrometry (SIMS)

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Energy loss of alpha particles - Prelab questions

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Development and characterization of 3D semiconductor X-rays detectors for medical imaging

Table of Content. Mechanical Removing Techniques. Ultrasonic Machining (USM) Sputtering and Focused Ion Beam Milling (FIB)

CHARACTERIZATION of NANOMATERIALS KHP

Development of a new MeV gamma-ray camera

Alpha-particle Stopping Powers in Air and Argon

Practical 1P4 Energy Levels and Band Gaps

Optics of complex micro structures

Experimental study of nonlinear laser-beam Thomson scattering

Semiconductor Detectors

Pingshan Wang. Jim Rui

MSE 321 Structural Characterization

Basic structure of SEM

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

Practical 1P4 Energy Levels and Band Gaps

The Dielectric Function of a Metal ( Jellium )

Relativistic Electrons

APPLICATION OF THE NUCLEAR REACTION ANALYSIS FOR AGING INVESTIGATIONS

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Chapter 10. Nanometrology. Oxford University Press All rights reserved.

XRF books: Analytical Chemistry, Kellner/Mermet/Otto/etc. 3 rd year XRF Spectroscopy Dr. Alan Ryder (R222, Physical Chemistry) 2 lectures:

Scanning Electron Microscopy

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

tip conducting surface

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

Micromachining structured optical fibres using focused ion. beam (FIB) milling

Dual Beam Helios Nanolab 600 and 650

Photoelectric Effect Experiment

Analysis of Insulator Samples with AES

Electron Transmission through Micrometer Sized Funnelshaped Tapered Glass Capillaries and Electron Micro-Beam Production

EXCESS HEAT PRODUCTION IN Pd/D DURING PERIODIC PULSE DISCHARGE CURRENT IN VARIOUS CONDITIONS

Temperature ( o C)

Chapter 10: Wave Properties of Particles

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

EE 527 MICROFABRICATION. Lecture 5 Tai-Chang Chen University of Washington

Highly Efficient and Anomalous Charge Transfer in van der Waals Trilayer Semiconductors

Synchrotron Radiation a Tool for Precise Beam Energy Measurements at the ILC

The intense, pulsed positron source EPOS at the Research Centre Dresden-Rossendorf

accelerating opportunities

Práctica de laboratorio número 6: Non-Rutherford scattering near the MeV 12 C(p,p) 12 C resonance

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples

Chapter 9. Electron mean free path Microscopy principles of SEM, TEM, LEEM

Particle Energy Loss in Matter

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

arxiv: v1 [cond-mat.other] 19 Sep 2011

SYSTEM FOR PIXE TRACE ELEMENT ANALYSIS AT MTF. M. Beňo, J. Dobrovodský, D. Vaňa, S. Minárik

4. Dispersion. The index of refraction of the prism at the input wavelength can be calculated using

Lobster-Eye Hard X-Ray Telescope Mirrors

The ISIS Penning H - SPS and Diagnostic Developments at RAL

Atomic and Nuclear Physics

Lecture 5-8 Instrumentation

Experiment 3 1. The Michelson Interferometer and the He- Ne Laser Physics 2150 Experiment No. 3 University of Colorado

SOLID STATE PHYSICS PHY F341. Dr. Manjuladevi.V Associate Professor Department of Physics BITS Pilani

Gamma and X-Ray Detection

MS482 Materials Characterization ( 재료분석 ) Lecture Note 5: RBS

Lessons learned from Bright Pixels and the Internal Background of the EPIC pn-ccd Camera

pp physics, RWTH, WS 2003/04, T.Hebbeker

R&D on Astroparticles Detectors. (Activity on CSN )

Radionuclide Imaging MII Detection of Nuclear Emission

Development of New MicroStrip Gas Chambers for X-ray Applications

Applied Fluid Mechanics

Ion Implantation ECE723

How to distinguish EUV photons from out-of-band photons

EEE4106Z Radiation Interactions & Detection

Differential Cross Section Measurements in Ion-molecule Collisions

Advanced Lab Course. X-Ray Photoelectron Spectroscopy 1 INTRODUCTION 1 2 BASICS 1 3 EXPERIMENT Qualitative analysis Chemical Shifts 7

Ion-beam techniques. Ion beam. Electrostatic Accelerators. Van de Graaff accelerator Pelletron Tandem Van de Graaff

DESIGN OF NEUTRON DOSE RATE METER FOR RADIATION PROTECTION IN THE EQUIVALENT DOSE

On the use of Kumakhov Polycapillaries to improve laboratory

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector

Fabrication at the nanoscale for nanophotonics

Chapter 12. Nanometrology. Oxford University Press All rights reserved.

Auger Electron Spectroscopy (AES)

Multi-GeV electron acceleration using the Texas Petawatt laser

Absorption of X-rays

CBE Science of Engineering Materials. Scanning Electron Microscopy (SEM)

Transcription:

Fadei Komarov Alexander Kamyshan Institute of Applied Physics Problems, Belarusian State University, Minsk, Belarus KomarovF@bsu.by

Tasks and Objects 2 Introduction and motivation Experimental setup designed for studying the transmission of swift ions through capillary systems Micro- and nanocapillary systems Transmission of swift protons through tapered micro- and nanocapillaries

Introduction and Motivation 3 Transport of charge particle beams through dielectric capillaries The principle of new optics discussed in this report is based on interaction of glancing beams of charged particles with a charged insulating surface of capillary walls. To a certain degree, it resembles us the motion of charged particles in channeling regimes along the lowindex directions of crystal lattices, or quanta motion in the waveguide regime.

Introduction and Motivation 4 Potential implementations of the phenomenon Analysis of the effect of surface charge on the character of motion of the ion beam forming this charge on an insulator is of interest both for new ion optics and for analysis of the interaction of particles with insulators at small angles of beam incidence with respect to the surface. The phenomenon of glancing motion of ion beams along a charged dielectric surface can be used to develop systems of transformation, control, and transport of charged particle beams; in particular, to obtain micro- and nanosized beams, which are interesting in local elemental and structural analysis, nanolithography, X-Ray radiography and applications in biology and medicine.

Introduction and Motivation 5 Potential implementations of the phenomenon In comparison with the existing tools for formation of micrometer- and nanometer-sized beams, this method is undoubtedly simpler and less expensive. At the same time, is satisfies all the requirements of submicron Rutherford backscattering spectrometry or analysis with application of induced characteristic X rays (PIXE). For example, this technique enables in-air PIXE measurements of various samples that are not compatible with the vacuum environment (wet solids, liquids and gases). Slightly tapered glass capillary optics can be applied as a differential pumping orifice as well as a focusing lens.

Capillary systems based on ion tracks 6 Fabrication of nanocapillaries in polymers As a unprecedented result on the low energy ion transmission through such capillaries I illustrate an experiment of N. Stolterfoht et al., NIM B203 (2003) 246. They measured the transmission of 3 kev Ne 7+ ions through capillaries of 100 nm diameter and 10 m length produced by etching ion tracks in a polyethylene terephthalate polymer foil. The foils were tilted up to ±25. The majority of Ne 7+ ions were found to survive the transmission in their initial charge. This capillary guiding of the Ne 7+ ion provides evidence that the inner walls of the capillaries become charged and electron capture from the surface is suppressed in a self-organizing process.

Capillary systems based on ion tracks 7 Time dependence of the transmitted Ne 7+ intensity showing the charging and discharging phenomena of capillaries in PET A beam of 1.3 na Ne 7+ ions is directed onto the PET foil tilted at 10. The transmitted Ne 7+ intensity measured at 10 increases exponentially with a time constant of 2.5 min. After 10 min the beam is turned off. Short beam pulses probe the decrease of the transmission with a time constant of 40 min.

Experimental Setup 8 Schematic of the experimental setup: (MC) matching circuit, (VFC) voltage-frequency converter, (VD) voltage divider, (EA) electrometric amplifier, (FVC) frequency-voltage converter, (RM) programmable rate meter, (FA) forming amplifier, (CSP) chargesensitive preamplifier, (SBD) silicon surface barrier detector, and (PC) personal computer.

Experimental Setup 9 Analytical equipment to study processes of charged particle interaction with capillary systems

Experimental Setup 10 This setup, which enters the implantation complex, formed on the basis of an ESU-2 electrostatic ion accelerator, consists of four units: (1) a system of ion beams formation, (2) a scattering chamber, (3) a measuring chamber, and (4) a system for detecting scattered ions. The parameters of the setup are as follows: the error in determining angles in measurement of angular distributions is not larger than 3.3 10 3 deg. the error in the capillary orientation with respect to the beam axis is not larger than 2.5 10 2 deg. the angular divergence of the initial beam ± 3.0 10 2 deg. the total measured energy resolution of the recording system does not exceed 16 kev a mobile silicon surface barrier detector is positioned at a distance of 90 cm from a capillary holder

Micro and nanocapillary systems 11 glass (borosilicate) capillaries with a diameter of 0.5 mm and length of 178 mm; glass tapered capillaries with an inlet diameter of 0.5 and 3.5 mm and outlet diameter of 0.1 mm and a taper angle of 0.5, 1.7 and 2.2 deg; arrays of uniform-sized nanopores with a diameter of 30-70 nm in anodic alumina.

Micro and nanocapillary systems 12 The individual capillary systems used for the transportation of proton beams

Transmission of proton beams 13 Shape and angular distribution of a 200 kev proton beam transmitted through the capillary with a taper angle of 1.7 deg

Transmission of proton beams 14 It should be mentioned that a practically uniform distribution of ion beam density with sharp edges is registered in this case. Moreover, a spot size amounts to 3.8 mm that corresponds to a beam divergence of ±0.13 deg just as an initial beam divergence was ±0.015 deg. An integral of an area under the curve in this figure shows that the fraction of transmitted protons is equal to 80%, i.e. the number of transmitted ions relative to those entering into the capillary. Therefore, taking into account that the outlet diameter of the capillary is 100 μm and the initial beam diameter amounts to 500 μm, the focusing factor reaches up to 20.

Transmission of proton beams 15 Count rate of particles transmitted through the capillary versus proton current at the input of the capillary

Transmission of proton beams 16 The results presented in this figure demonstrates a strong nonlinear behavior of the current at the output of the capillary on intensity of the input beam up to an input current of 5x10-13 A. It is well accepted that such protons are guided electrostatically due to the charging up of the inner wall of capillaries made of insulating material.

Transmission of proton beams 17 Time distributions of protons transmitted through a tapered capillary (a) and cylindrical capillary (b)

Transmission of proton beams 18 In spite of the practically equal currents at the input of these capillaries, time evolutions of beam currents at the output of the capillaries are strongly different in shapes and frequencies of the beam intensity oscillations. Current pulse frequencies of ions transmitted through the tapered capillary exceed essentially those for the cylindrical capillary. On the contrary, more shorter pulse durations are typical for the tapered capillary. The mentioned above experimental results confirm our recent assumption on a dominant role of charging up a face part of the capillary in the transformation of continuous ion beams into oscillating ones. This effect is not observed if an input hole of capillaries exceeds the beam diameter.

Transmission of proton beams 19 The transparency of this capillary with a taper angle of 0.5 deg is 300 times less than this parameter for the capillary with a taper angle of 1.7 deg Shape and angular distribution of 200 kev protons transmitted through a capillary with a taper angle of 0.5 deg

Transmission of proton beams 20 Angular distribution of 320 kev protons transmitted through a capillary with a taper angle of 2.2 deg

Transmission of proton beams 21 Energy spectrum of transmitted protons with an initial energy of 320 kev with and without capillary. The taper angle is 1.7 deg. Curve 1 is for the initial beam and curve 2 is for the transmitted beam

Transmission of proton beams 22 The most of ions transmit the capillary without energy loss, however, the low energy tail certainly exists (curve 2). It means that those transmitted ions moving with higher transverse energies and suffering the small angle scattering lose their energy interacting with an inner surface of the capillary. It should be noted that these particles cause only a very modest widening of the initial energy distribution (less than 5 to 6%).

Transmission of proton beams 23 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. Diameters of entrance holes on the face side of the sample. The thickness of anodic alumina wafers was 42 μm. Diameter of entrance holes was in a range of 60-70 nm and the density of holes was 1.2x10 10 cm -2

Transmission of proton beams 24 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. SEM cross-section images of a cleaved sample

Transmission of proton beams 25 Angular distribution of protons with an energy of 190 kev transmitted through the Al 2 O 3 nanostructure sample oriented along the beam axis

Transmission of proton beams 26 Angular distribution of protons with energy of 290 kev transmitted through the Al 2 O 3 nanostructure sample oriented along the beam axis

Transmission of proton beams 27 Angular distribution of 290 kev protons transmitted through the Al 2 O 3 sample at a misorientation angle of 0.07 deg

Transmission of proton beams 28 It should be noted that the FWHM of central peaks in the both angular distributions is considerably narrower than the width of the initial beam. The presented in the last three figures proton beam intensities were measured behind the sample with a thickness of 42 μm that considerably (more than one order of magnitude) exceeds ranges of protons in this material. This is an evidence of an anomalous motion of protons like the hyperchanneling of charged particles along the low-index directions of crystal lattices. The transmission coefficient in this system achieved a few percent if the face part of the sample was covered with a thin Au layer.

Micro and nanocapillary systems 29 The Kumakhov s microcapillary system with a diameter of 30 nm of individual glass capillaries

Application of capillary ion optics 30 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. (A) the glass capillary optics, (B) the X-ray detector, (C) the sea water droplet

Application of capillary ion optics 31 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. PIXE spectrum of sea water

Application of capillary ion optics 32 External PIXE spectrum of a gallbladder tissue

Application of capillary ion optics 33 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. The experimental setup for micro-beam production using a tapered glass capillary (J. Hasegawa et al., NIM B 266 (2008) 2125)

Proton-induced X-ray radiography 34 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. A schematic of quasi-monochromatic X-ray imaging using the glasscapillary-based micro-beam generator

Application of capillary ion optics 35 The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again. An image of a miniature bulb filament taken by Cu K X-rays. Capillary tip: D 25 m, exposure time: 1 h, magnification: 10x (J. Hasegawa et al., NIM B 266 (2008) 2125)

Summarizing 36 We have confirmed that a few hundred kev proton beams are successfully focused by the tapered capillary optics. The areal density of the transmitted beam is enhanced by approximately 20 times. Charging up a face part of the capillary causes the transformation of continues ion beams to oscillating ones. The most of protons (94 95%) in the energy range of 150 to 320 kev transmit the capillary without energy loss. Changing a taper angle from 0.5 deg to 1.7 deg evidences increase of the transmission coefficient more than by 300 times keeping the initial energy spectrum of ions. Compared with the conventional micro-beam facilities, the usage of tapered capillaries is certainly simple and low-cost, thus providing an interesting technique of submicron RBS or PIXE elemental analyses. Moreover, if the ion species are extended to heavier elements, the present method provides highly local versatile maskless ion implantation technique.

Summarizing 37