Investigations on warm dense plasma with PHELIX facility

Similar documents
GA A25842 STUDY OF NON-LTE SPECTRA DEPENDENCE ON TARGET MASS IN SHORT PULSE LASER EXPERIMENTS

Innovative XUV- und X-ray-Spectroscopy to explore Warm Dense Matter

HED Physics. 1) By means of laser-driven shock waves (LMJ as driver, PETAL as a backlighter)

Development of a WDM platform for chargedparticle stopping experiments

Cauchois Johansson x-ray spectrograph for kev energy range

The PETAL+ project X-ray and particle diagnostics for plasma experiments at LMJ - PETAL

X pinch as a source for X-ray radiography

PoS(ECPD2015)042. Hardened x-ray crystal spectrometer. Speaker. C. Reverdin 1, L. Lecherbourg, V. Dervieux, D. Gontier, B. Loupias. S.

Spectral analysis of K-shell X-ray emission of magnesium plasma produced by ultrashort high-intensity laser pulse irradiation

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

Laser-driven proton acceleration from cryogenic hydrogen jets

Stigmatic X-ray imaging using a single spherical Laue crystal

EXTREME ULTRAVIOLET AND SOFT X-RAY LASERS

Application of Proton Radiography to High Energy Density Research

Measurement of Long-Scale-Length Plasma Density Profiles for Two-Plasmon Decay Studies

Laser Plasma Monochromatic Soft X-ray Source Using Nitrogen Gas Puff Target

188 L. Jakubowski and M.J. Sadowski temperature. Some examples of the registered X-ray images are shown in Fig.1. Figure 1. X-ray pinhole images from

Ion Acceleration from the Interaction of Ultra-Intense Laser Pulse with a Thin Foil

Experimental X-Ray Spectroscopy: Part 2

An Overview of Laser-Driven Magnetized Liner Inertial Fusion on OMEGA

Monochromatic 8.05-keV Flash Radiography of Imploded Cone-in-Shell Targets

Part XI. Optimising Femtosecond K α Sources

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

SPARCLAB. Source For Plasma Accelerators and Radiation Compton with Laser And Beam

Wolter Imaging On Z. Chris Bourdon, Manager Z Imaging and Spectroscopy Julia Vogel, LLNL; Ming Wu, SNL ICF Diagnostics Workshop, October 5 th 2015

Laser ion acceleration with low density targets: a new path towards high intensity, high energy ion beams

Set-up for ultrafast time-resolved x-ray diffraction using a femtosecond laser-plasma kev x-ray-source

PHYSICS OF HOT DENSE PLASMAS

Calibration and validation of computer models for radiative shock experiment

An Overview of Laser-Driven Magnetized Liner Inertial Fusion on OMEGA

ION ACCELERATION FROM ULTRA THIN FOILS

plasma optics Amplification of light pulses: non-ionised media

High Energy X-ray Spectroscopy for Radiography and Atomic Physics Investigations in Laser Produced Plasmas

Energetic neutral and negative ion beams accelerated from spray target irradiated with ultra-short, intense laser pulses

Observation of MeV multicharged ions and hot electrons accelerated by a 65-fs laser pulse

Photoelectron spectroscopy Instrumentation. Nanomaterials characterization 2

Ultrafast X-Ray-Matter Interaction and Damage of Inorganic Solids October 10, 2008

The MIT Nuclear Products Generator for development of ICF diagnostics at Omega / Omega EP and the NIF

Fundamental investigation on CO 2 laser-produced Sn plasma for an EUVL source

Study of matter in extreme conditions using 4th generation FEL light sources

X ray and XUV phase contrast diagnostics for ELI NP

Presented at the Michigan Institute for Plasma Science and Engineering

Institute for Laser Technology

The MID instrument.

Laser trigged proton acceleration from ultrathin foil

Multi-GeV electron acceleration using the Texas Petawatt laser

Laser Plasma Wakefield Acceleration : Concepts, Tests and Premises

X-Ray Photoelectron Spectroscopy (XPS)

Generation of X-Rays in the SEM specimen

X-Ray Photoelectron Spectroscopy (XPS)

Inertial Confinement Fusion Experiments & Modeling

Influence of an intensive UV preionization on evolution and EUV-emission of the laser plasma with Xe gas target (S12)

The MIT Accelerator for development of ICF diagnostics at OMEGA / OMEGA-EP and the NIF

Monte Carlo Simulator to Study High Mass X-ray Binary System

Can laser-driven protons be used as diagnostics in ICF experiments?

A Detailed Postprocess Analysis of an Argon Gas Puff Z-pinch Plasma Using SPEC2D

Secondary Ion Mass Spectrometry (SIMS)

Development of a table top TW laser accelerator for medical imaging isotope production

ULTRA-INTENSE LASER PLASMA INTERACTIONS RELATED TO FAST IGNITOR IN INERTIAL CONFINEMENT FUSION

Laser-driven X-ray sources: realization and future trends

Photofission of 238-U Nuclei

Ultrafast Radiation Chemistry and the Development of Laser Based Electron Sources*

Lecture 1. Introduction

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Intrinsic beam emittance of laser-accelerated electrons measured by x-ray spectroscopic imaging

FLASH SIMULATIONS OF EXPERIMENTS TO EXPLORE THE GENERATION OF COSMOLOGICAL MAGNETIC FIELDS AT LABORATOIRE d'utilisation DES LASERS INTENSES (LULI)

SHIELDING CALCULATIONS FOR THE HARD X-RAY GENERATED BY LCLS MEC LASER SYSTEM R. QIU, J. C. LIU, S. H. ROKNI AND A. A. PRINZ

Laser and pinching discharge plasmas spectral characteristics in water window region

LABORATORY SIMULATION OF MAGNETOSPHERIC PLASMA SHOCKS

Small Quantum Systems Scientific Instrument

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

Electron-Acoustic Wave in a Plasma

PHYS 3650L - Modern Physics Laboratory

Lecture 5. X-ray Photoemission Spectroscopy (XPS)

RELATIVISTIC SPECTROSCOPY OF BLACK HOLES

High-energy collision processes involving intense laser fields

SPARCLAB. Source For Plasma Accelerators and Radiation Compton. On behalf of SPARCLAB collaboration

Evidence of high-n hollow ion emission from Si ions 1 pumped by ultraintense x-rays from relativistic laser 2 plasma 3

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Spectral Lines of Multi-Charged Fluorine from a Plasma Interacting with a Strong Quasimonochromatic Electric Field

This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract

XRD endstation: condensed matter systems

The MEC endstation at LCLS New opportunities for high energy density science

Supporting Information s for

High-Resolving-Power, Ultrafast Streaked X-Ray Spectroscopy on OMEGA EP

CONCEPTUAL STUDY OF A SELF-SEEDING SCHEME AT FLASH2

High energy particles from the Sun. Arto Sandroos Sun-Earth connections

Measurement of CO 2 laser absorption by thin plasma as a 13.5 nm EUV light source!

Introduction to XAFS. Grant Bunker Associate Professor, Physics Illinois Institute of Technology. Revised 4/11/97

Diagnosing OMEGA and NIF Implosions Using the D 3 He Spectrum Line Width

Technical University of Denmark

Abstract... I. Acknowledgements... III. Table of Content... V. List of Tables... VIII. List of Figures... IX

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Spectroscopic Studies of Soft X-Ray Emission from Gadolinium Plasmas

Betatron radiation from a hybrid self-modulated wakefield and direct laser accelerator

Delay-Line Imaging and XPCS

Construction and Physics of the Dense Plasma Focus device

Numerical Modeling of Radiative Kinetic Plasmas

Direct-Drive, High-Convergence-Ratio Implosion Studies on the OMEGA Laser System

CALIBRATION OF A VON HAMOS SPECTOMETER FOR X-RAY SOURCE MONITORING. Capstone Project Report for. Physics 492R. Michael Johnson

Transcription:

2 nd EMMI Workshop on Plasma Physics with Intense Laser and Heavy Ion Beams, May 14-15, Moscow Investigations on warm dense plasma with PHELIX facility S.A. Pikuz Jr., I.Yu. Skobelev, A.Ya. Faenov, T.A. Pikuz, S.V. Gasilov Joint institute for High Temperatures RAS

Application of high-resolution x-ray spectroscopy and radiography for investigations of plasma created by PHELIX laser. X-ray diagnostics of temperature, density, ionization state of hightemperature plasma created under interaction of high intense PHELIX laser pulse with structured and homogeneous targets. Observations of the fast ions generated in the PHELIX laser-produced plasma by X-Ray spectroscopy methods. X-ray spectroscopy and radiography of warm dense matter. Diagnostics of MG-magnetic fields generated in the laser-produced plasma by observations of X-Ray plasma satellites and Zeeman splitting of X-Ray spectral lines.

Application of high-resolution x-ray spectroscopy and radiography for investigations of plasma created by PHELIX laser. X-ray diagnostics of temperature, density, ionization state of hightemperature plasma created under interaction of high intense PHELIX laser pulse with structured and homogeneous targets. Observations of the fast ions generated in the PHELIX laser-produced plasma by X-Ray spectroscopy methods. X-ray spectroscopy and radiography of warm dense matter. Diagnostics of MG-magnetic fields generated in the laser-produced plasma by observations of X-Ray plasma satellites and Zeeman splitting of X-Ray spectral lines.

Application of high-resolution x-ray spectroscopy and radiography for investigations of plasma created by PHELIX laser. X-ray diagnostics of temperature, density, ionization state of hightemperature plasma created under interaction of high intense PHELIX laser pulse with structured and homogeneous targets. Observations of the fast ions generated in the PHELIX laser-produced plasma by X-Ray spectroscopy methods. X-ray spectroscopy and radiography of warm dense matter. Diagnostics of MG-magnetic fields generated in the laser-produced plasma by observations of X-Ray plasma satellites and Zeeman splitting of X-Ray spectral lines.

High resolution X-ray X spectroscopy for WDM

The way to produce and investigate WDM Warm plasma T e warm ~ 1-30 ev Hot electrons Hot plasma T e hot ~ 200 1000 ev K α lines of ions with small charges to spectrometer Directly measured value plasma ionization state; T warm e can be determined

X-ray spectrometers and experimental setup Hot plasma (T e ~ 1 kev) on the front side of foil target WDM on the rare side of the foil target (T e ~ 10 ev, N e ~10 23 cm -3 FSSR spectrometers provide high spectral and spatial resolution, simultaneously

Experiment Experiments on COMET LLNL facility // T. Ditmire group, UT Austin and LLNL

Inner-shell KαK of solid Ti, T e = 1 20 ev T e = 1 ev T e = 10 ev T e = 20 ev

Inner-shell KαK of solid Ti, T e = 30 100 ev 30 ev T e =30 ev 50 ev T e =50 ev 100 ev T e =100 ev

Inner-shell KαK of solid Ti, T e = 200 1000 ev 200 ev 500 ev 1000 ev

Effect of laser intensity T e =20 ev T e =18 ev T e =15 ev // T. Ditmire group, UT Austin and LLNL

Effect of Ti foil thickness (Ti +0.1 um Al) 15 ev 13 ev 8 ev

Effect of coating on 25 um Ti foil 18 ev 13 ev 10 ev

Spatial resolution along target plane Kα1 X Kα2 0 um 30 um 60 um 90 um

Spatial resolution and fountain effect Spatial resolution and fountain effect Kα 1 λ ~ 520 um Side peaks Mean Kα1 Max Kα1 Blue edge -800-600 -400-200 0 200 400 600 800 Space dimentions, um

WDM investigations suggestions We suggest in the frame of the EMMI project: Using ultrahigh laser fluxes ~ 10 19-10 20 W/cm 2 to increase spectral brightness and find which of excited levels can exist in strongly coupled plasma by mean of registration K α, K β, K γ, spectral lines To provide higher energy of hot electrons on front target surface, so the investigations of WDM for large Z materials will be available.

X-ray and ion radiography of WDM

Laser generated plasma as a source of probe radiation Intense laser pulse is unique and useful tool to generate a flux of X-ray photons as well as energetic charge particles, simultaneously Both fluxes can be used for shadowgraphy imaging and absorption measurements of different objects and processes including low contrast structures in plasma Following diagnostic opportunities can be realized Ion and proton radiography X-ray absorption imaging and spectroscopy X-ray phase contrast imaging Source size is important to provide spatial and spectral resolution, spatial coherency Energy of probing particles and monochromatization are important to provide the sensitivity on density and chemical staff of an object Source brightness and scheme luminosity are important to provide wider dynamic range, precise measurements and image quality

X-ray monochromatic backlighting scheme Features: - Backlighter and object are inside Rowland circle = High luminosity = Higher spatial resolution - Angle of radiation incidence is far from normal one = Wide spectral range = Spatial resolution tunable Sagittal and tangential focuses are not on the same position. By choosing detector position the spatial resolution along each direction can be tuned up. Monochromatic scheme allows to measure object density or chemical staff in precise according to probe radiation absorption

Experimental setup Main laser: 1 ns, 2ω, 300 J, d = 400 um I = 5*10 13 W/cm 2 Backlighting laser: 1 ns, 2ω, 250 J, d = 150 um, I = 10 15 W/cm 2 // M. Koenig group, LULI Ecole Polytechnique Spherical crystal: Quartz, 2d = 4.912 A II reflection order Curvature 150 mm Magnification 10

Target design Holder Pusher Shock wave generation in CH sliver ns laser Composite pusher CH 10 um + Al 10 um + CH 10 um CH sliver

Calibration results 8 um 20 um resolution

Shock wave density measurements X-ray backlighting image in V Heα spectral line Transmission Holder Shocked CH Due to spectral selectivity of backlighting image the density profile of the object can be measured in precise. with spatial resolution along shock front. The maximum compression of 2.85 is obtained for shock wave in CH sliver

Shock wave evolution and velocity In order to resolve the evolution of imaging object the delay between main and backlighter laser pulses can be aligned t = 5 ns t = 9 ns Shock front velocity is measured to be equal 19 km/s During the propagation the cylindrical symmetry of shock front is stable

Diagnostic Obstacle Brightness of x-ray source preferably depends on laser energy not by pulse intensity On upgraded LULI facility 50 J in 1 ps is available now instead of 500 J in 1 ns before. X-ray source has brightness not enough for monochromatic shadowgraphy imaging. Temporary solution: Change to proton radiography diagnostics in quite the same experimental setup. RCF film instead of X-ray crystal Solution: Special design for backlighting target. Increase of detector sensitivity

Proton radiography imaging results No ambient gas Ar 20 bar Secondary structure Jet Jet Jet Nozzle Delay 10 ns 5 ns Amb. flow 30 ns Probe proton energy ~ 5 MeV Proton radiography is perfect to image the evolution of plasma structures but not for quantitative measurements on their densities. Further development of soft X-ray diagnostics is on demand.

WDM investigations suggestions 2, 3 We suggest in the frame of the EMMI project: To study shock compression in WDM for higher Z materials, metals, by means of x-ray monochromatic shadowgraphy and ion radiography. To develop hard X-ray backlighting imaging using fs PHELIX beam to produce bright source of probe radiation.

Conclusion Conclusion Available devices and methods High resolution spectrometers Spherically bent crystals Modeling of spectra Backlighting schemes Absorption and phase contrast Forthcoming tasks Create and study of Super dense plasma Hot dense plasma Warm dense plasma Effective sources for ion- and proton-radiography Images of nanoscale foils and biological samples Measurement of MG magnetic fields Monocromatic imaging of shock waves and plasma jets Modeling of astrophysical phenomena in laboratory Investigation of new spectroscopy phenomena