STUDY OF FLOW AT THE AIR WATER INTERFACE

Similar documents
Water Hammer Simulation For Practical Approach

Increasing calculation accuracy in the design stage of a gas transportation system

Exam #2: Fluid Kinematics and Conservation Laws April 13, 2016, 7:00 p.m. 8:40 p.m. in CE 118

International Journal of Civil Engineering and Geo-Environment. Investigation of Parameters Affecting Discrete Vapour Cavity Model

UNIT II Real fluids. FMM / KRG / MECH / NPRCET Page 78. Laminar and turbulent flow

Reservoir Oscillations with Through Flow

ANALYTICAL AND NUMERICAL SOLUTION FOR A RIGID LIQUID-COLUMN MOVING IN A PIPE WITH FLUCTUATING RESERVOIR-HEAD AND VENTING ENTRAPPED-GAS

Lesson 6 Review of fundamentals: Fluid flow

Comparing Unsteady Modeling Approaches of Surges Caused by Sudden Air Pocket Compression

Hydraulics Prof. Dr. Arup Kumar Sarma Department of Civil Engineering Indian Institute of Technology, Guwahati

CIE4491 Lecture. Hydraulic design

Chapter Four Hydraulic Machines

REE 307 Fluid Mechanics II. Lecture 1. Sep 27, Dr./ Ahmed Mohamed Nagib Elmekawy. Zewail City for Science and Technology

Q1 Give answers to all of the following questions (5 marks each):

5 ENERGY EQUATION OF FLUID MOTION

CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD

Surge Analysis Using Transient Pressure Theory

The Bernoulli Equation

V/ t = 0 p/ t = 0 ρ/ t = 0. V/ s = 0 p/ s = 0 ρ/ s = 0

Mass of fluid leaving per unit time

NPTEL Quiz Hydraulics

Chapter Four fluid flow mass, energy, Bernoulli and momentum

Experiment (4): Flow measurement

ENGINEERING FLUID MECHANICS. CHAPTER 1 Properties of Fluids

Chapter Four Hydraulic Machines

Lecture Note for Open Channel Hydraulics

Table of Contents. Preface... xiii

vector H. If O is the point about which moments are desired, the angular moment about O is given:

FLUID MECHANICS. Chapter 3 Elementary Fluid Dynamics - The Bernoulli Equation

Analytical and Numerical Investigation of Transient Gas Blow down

Design of Restricted Orifice Surge Tank

EXAMPLE SHEET FOR TOPIC 3 AUTUMN 2013

GODUNOV-TYPE SOLUTIONS FOR TWO-PHASE WATER HAMMER FLOWS

UNSTABLE OPERATION OF FRANCIS PUMP-TURBINE AT RUNAWAY: RIGID AND ELASTIC WATER COLUMN OSCILLATION MODES

Where does Bernoulli's Equation come from?

Fluid Dynamics Exercises and questions for the course

Fluid Mechanics. du dy

Chapter 4 DYNAMICS OF FLUID FLOW

Natural Frequencies Behavior of Pipeline System during LOCA in Nuclear Power Plants

Hydraulics. B.E. (Civil), Year/Part: II/II. Tutorial solutions: Pipe flow. Tutorial 1

Dynamic Behavior of a 2 Variable Speed Pump- Turbine Power Plant

FE Fluids Review March 23, 2012 Steve Burian (Civil & Environmental Engineering)

Fluid Mechanics Prof. T.I. Eldho Department of Civil Engineering Indian Institute of Technology, Bombay. Lecture - 17 Laminar and Turbulent flows

Group #4 (Firko, Johnson)

HYDRAULIC TRANSIENTS IN PUMPING SYSTEMS WITH HORIZONTAL PIPES

UNIT I FLUID PROPERTIES AND STATICS


Experiment- To determine the coefficient of impact for vanes. Experiment To determine the coefficient of discharge of an orifice meter.

R09. d water surface. Prove that the depth of pressure is equal to p +.

Objectives. Conservation of mass principle: Mass Equation The Bernoulli equation Conservation of energy principle: Energy equation

Closed duct flows are full of fluid, have no free surface within, and are driven by a pressure gradient along the duct axis.

THE EFFECT OF TWO PHASE (AIR-WATER) FLOW CHARACTERISTICS ON MOMENTUM FLUX DUE TO FLOW TURNING ELEMENTS AT ATMOSPHERIC CONDITIONS

FURTHER INVESTIGATION OF PARAMETERS AFFECTING WATER HAMMER WAVE ATTENUATION, SHAPE AND TIMING PART 2: CASE STUDIES

EXPERIMENT No.1 FLOW MEASUREMENT BY ORIFICEMETER

BERNOULLI EQUATION. The motion of a fluid is usually extremely complex.

MECHANICAL PROPERTIES OF FLUIDS:

For example an empty bucket weighs 2.0kg. After 7 seconds of collecting water the bucket weighs 8.0kg, then:

Compressible Duct Flow with Friction

Transient Phenomena in Liquid/Gas Flow in Pipelines

Binary-coded and real-coded genetic algorithm in pipeline flow optimization

1.060 Engineering Mechanics II Spring Problem Set 4

PUMPING STATION SCHEDULING FOR WATER DISTRIBUTION NETWORKS IN EPANET

IMPLICIT NUMERICAL SCHEME FOR REGULATING UNSTEADY FLOW IN OPEN CHANNEL Mohamed. T. Shamaa 1, and Hmida M. Karkuri 2

Block 3 Open channel flow

Modeling and Analysis of Dynamic Systems

VARIED FLOW IN OPEN CHANNELS

A kinetic scheme for transient mixed flows in non uniform closed pipes: a global manner to upwind all the source terms

MOMENTUM PRINCIPLE. Review: Last time, we derived the Reynolds Transport Theorem: Chapter 6. where B is any extensive property (proportional to mass),

THEORETIC AND EXPERIMENTAL RESEARCH ON THE CHARACTERISTIC DIAGRAMS OF A NEW TYPE OF ROTATING MACHINE WITH PROFILED ROTORS

SOE2156: Fluids Lecture 7

Study fluid dynamics. Understanding Bernoulli s Equation.

AN INDIRECT MEASUREMENT METHOD OF TRANSIENT PRESSURE AND FLOW RATE IN A PIPE USING STEADY STATE KALMAN FILTER

COMPUTATION OF MASS OSCILLATIONS IN A SURGE TANK BY FINITE ELEMENT TECHNIQUE

Basic Fluid Mechanics

Hydraulics Prof Dr Arup Kumar Sarma Department of Civil Engineering Indian Institute of Technology, Guwahati

Hydraulics for Urban Storm Drainage

2 Internal Fluid Flow

COURSE NUMBER: ME 321 Fluid Mechanics I 3 credit hour. Basic Equations in fluid Dynamics

Instructor : Dr. Jehad Hamad. Chapter (7)

Figure 1 Answer: = m

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

BACHELOR OF TECHNOLOGY IN MECHANICAL ENGINEERING (COMPUTER INTEGRATED MANUFACTURING)

dynamics of f luids in porous media

4.1 LAWS OF MECHANICS - Review

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati

HOW TO GET A GOOD GRADE ON THE MME 2273B FLUID MECHANICS 1 EXAM. Common mistakes made on the final exam and how to avoid them

Pressure in stationary and moving fluid Lab- Lab On- On Chip: Lecture 2

Rate of Flow Quantity of fluid passing through any section (area) per unit time

UNIT IV. Flow through Orifice and Mouthpieces and Flow through Notchs and Weirs

CEE 3310 Control Volume Analysis, Oct. 7, D Steady State Head Form of the Energy Equation P. P 2g + z h f + h p h s.

Contents. Diaphragm in pressure pipe: Steady state head loss evolution and transient phenomena. Nicolas J. Adam Giovanni De Cesare

BOOST CIRCUIT CONTROL IN TRANSIENT CONDITIONS

Mass flow determination in flashing openings

Modelling of dispersed, multicomponent, multiphase flows in resource industries. Section 3: Examples of analyses conducted for Newtonian fluids

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

EGN 3353C Fluid Mechanics

Simulation of low pressure water hammer

Pressure in stationary and moving fluid. Lab-On-Chip: Lecture 2

Experimental and Numerical Investigations of the Effect of Net Positive Suction Head on Water Hammer In Pipeline Systems

Introduction to Fluid Machines, and Compressible Flow Prof. S. K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Transcription:

U.P.B. Sci. Bull., Series D, Vol. 7, Iss., ISSN 5-5 STUDY OF FLOW AT THE AIR WATER INTERFACE Diana Maria BUCUR, Eugen Constantin ISBĂŞOIU În această lucrare se urmăreşte analizarea creşterii presiunii şi a vitezei în regimurile de curgere nepermanente, provocată de prezenţa unei pungi de aer în faţa coloanei de apă, într-un sitem conservativ închis sau deschis. Analiza undei de presiune atât în mediul lichid cât şi în mediul gazos se face unidimensional, urmărindu-se efectele propagării undelor, în ipoteza separării coloanei de apă de punga de aer printr-o interfaţă verticală. Aceasta ipoteză simplificatoare duce la limitarea capacităţii predictive a modelului matematic. The object of this study is to determine the pressure and velocity oscillation in transitory flows, caused by the presence of an air pocket in front of the water column. The hydraulic system is conservative, with the downstream end closed or opened. The pressure wave analyze is one-dimensional both in water or air phase. The mathematical model is based on the hypothesis that the water column is separated from air by a vertical interface. This simplifying hypotheses leads to limited predictive capacity of the model. Keywords: air water, air pocket, interface, pressure wave.. Introduction When air gets inside of a pressurized water system, the two fluids move together. The air release can be useful sometimes, because the pressure wave velocity can significantly decrease. But the entrapped air can cause undesirable and consistent pressure oscillations, depending on air quantity and on its location in the pipe. When air is trapped between two water columns it can cause pressure rise over the supplying pressure []. The expulsion through orifices or vanes, followed by the water column, can cause water hammer pressure. If the orifice is relatively small, the flow speed is decelerated. In this situation, the pressure magnitude depends strongly on orifice size. For relatively large size of the orifice, the flow speed increases, but, the impact can be minim, because the pressure wave is decreased. In case of intermediate sizes of the orifice, the air is expulsed fast, and the water can flow with high velocity, affecting the pipe at the impact. Lecturer, Dept. of Hydraulics and Hydraulic Machinery, University POLITEHNICA of Bucharest, România, e-mail: dmbucur@yahoo.com Prof., Dept. of Hydraulics and Hydraulic Machinery, University POLITEHNICA of Bucharest, România, e-mail: ecisbasoiu@yahoo.com

Diana Maria Bucur, Eugen Constantin Isbăşoiu The entrapped air in hydraulic systems is important in transient flow study. The mathematical models can consider, or not, the dynamic behavior of the liquid phase and of the pressure wave in gas mass. Some models consider only the inertial effect of the water column, while most models consider the elasticity of the air pocket. Usually, the mathematical models used to study the effects of air pockets over the transient regimes have simplified configurations. This is mainly caused by reasons such as: - pressure wave speed, because in some systems it can vary from m/s to m/s, depending on air quantity, which is difficult to be determined; - air pockets implosion, which can happen suddenly or slowly. This makes difficult the mathematical determination of air pockets behavior; - the structure of a pipe system is very complicate with a lot of branches, slope changes, aeration shafts and other discontinuities; - rapid transition from free to pressurized flow. The equations used in transient flow study are: Reynolds transport theorem, mass and momentum conservation equation and water hammer equations. For the mathematical model is considered a pipe supplied from a tank with constant pressure head. At the downstream end of the pipe, in front of the water column, there is an air pocket. The water column and the air pocket are separated by a closed vane (SV), which is opened in a very short time. The assumptions made for the mathematical model of the flow are: - the pipe is horizontal. The difference between the model which considers the deformation of water column and the rigid water column model is smaller than % for rapid filling horizontal pipes []; - the air pocket fills the whole section of the pipe; - the air-water interface is vertical (it is assumed that the air pocket is keeping the cylindrical shape); - the evolution of gas mass is polytrophic; - rigid or elastic liquid phase; - cvasistatic or dynamic evolution of gas mass; - one-dimensional study; - the Darcy coefficient is the same as in uniform flow. The difference between maximum pressure in steady flow model and the maximum pressure in the unsteady flow model is less that 5% [].. Pipe closed at downstream end Figure presents the scheme for the case of a rapid filling horizontal pipe closed at the downstream end which contains air. At the moment t = s, the

Study of flow at the air water interface 5 separation vane and the downstream end are closed. In order to obtain the air pocket, the water downstream the separation vane is drained off (through vane DV) and the air gets inside at atmospheric pressure (through AV). The flow parameters are: H, upstream pressure head, v, water column velocity during rapid filling, V air volume, l water column length, D pipe diameter and l a air column length. The pipe length is L = m and the pipe diameter is D = 7 mm. Atmospheric pressure, p = p H R H dx x SV AV l l a Fig.. Scheme for the mathematical model with the pipe closed at downstream end. Considering the displacement of the water column at moment t s the parameters are, V = la A, p = p, m = m = const. ρla A = ρ( la x) A, () so the variation of the air density can be determined considering the length of the air column, l a v DV la ρ ρ = ρ =, or la x x la The pressure variation results as, ρ ρ = x l a. () n p p p x = p = = p ρn ρn n + () x la x la where n is the polytrophic exponent, x is the displacement of water column, A is the flow section area, p is the atmospheric pressure. Because the phenomenon is very fast, the gas mass evolution is considered without heat exchange, so the polytrophic exponent is equal to adiabatic exponent, k. In engineering computations good quality results are obtained for k =. [].

Diana Maria Bucur, Eugen Constantin Isbăşoiu Bernoulli equation between a point at the free surface of the supply tank and a point at the air water interface is v p v p l + x dv + + gh = + + λ v v + ( l + x), () ρw ρw D p with initial values at t =, v and + H = H R ρwg The total pressure head in supply tank H R, is v dv λ gh R = + ( l + x) + ( l + x) v v + D, p ρ w. (5) Thus, the governing equation system becomes dv v = gh R l + x dx = v n x p = p + la x p ρw λ ( l + x) v D v () The system is solved using a program made in MatLAB, with a Runge Kutta method. The numerical simulations are made for different values of the supply head and of the water column lengths. They correspond to an experimental set-up, which in future works will be used to validate the mathematical model. The Darcy coefficient is considered λ =.. Figures and present the pressure oscillations for the minimum and maximum supply head available at the experimental set-up, H R, and for each supply head three different lengths of water column, l. If the displacement of water column, x, regarding to water column length, l, is neglected and the water column length is considered constant [], the mathematical model is simplified and the equation (5) can be written as follows v dv l gh R = + l + λ v v + D p. (7) ρw

Study of flow at the air water interface 7 In this case the governing equations system becomes dv v p λl = gh R v v l ρw D dx = v n la p = p la x ().5 x 5 a).5 x a).5.5.5.5 x 5.5.5.5 b) Pressure p -.5.5.5.5.5.5 Time t - x b).5 x 5 c) x.5 c).5.5.5.5.5 Fig.. Pressure oscillations for H R =. m and l a) 9.5 m, b) 9 m, c).5 m. Fig.. Pressure oscillations for H R = 5. m and l a) 9.5 m, b) 9 m, c).5 m. Figs. and 5 present a comparison between the two governing equations systems () and (), in order to determine the influence of water length displacement, x, over the pressure and velocity oscillations. In the first seconds of the process both models have similar results, so the model can be simplified by considering constant the water column length.

Diana Maria Bucur, Eugen Constantin Isbăşoiu x 5 9 7 5 5 7 9 Fig.. Pressure oscillation for H R =. m and water column length l = 9 m, determined with both models velocity V -[m/s] - - - - 5 7 9 Fig. 5. Velocity oscillations of water column, for H R =. m and water column length l = 9 m, determined with both models. Pipe opened at downstream end The equations system is determined for pressure and air-water interface velocity, in case the downstream end of the pipe is opened and has diaphragm with the cross section A (Fig. ). At the initial moment t = s, the separation vane (SV) is closed. The phenomenon is initiated when the separation vane is suddenly opened (considering a very short time). The flow equations are the same as in the closed pipe case dv p v p λ = gh + v v l + x ρwg ( l + x) l + x ρw D (9) dx = v Because the space occupied by air has the volume, V = A( la x), the variation in time of the air volume is

Study of flow at the air water interface 9 dv dx = A. () Atmospheric pressure, p = p H R H D, A SV Ød v l l a w A Fig.. Scheme for the mathematical model with the pipe opened at the downstream end. The air discharge through the orifice can be expressed as a function of the air pressure p in the pipe n p p n Q = μa = w μa n ρ p dx x n p n, () p where μ is the discharge coefficient, estimated at μ =., n is the polytrophic exponent, and w is the air velocity. The evolution of the phenomenon is considered without heat exchange because it is very rapid. So the polytrophic exponent is equal to the adiabatic exponent, n = k =. []. The continuity equation of the gas mass can be written as dp p dv = k + Q V () The governing equations system in this case is dv dx dp v = gh R l + x = v = k p A( la x) p ρw dx A λ ( l + x) v D + Q v ()

9 Diana Maria Bucur, Eugen Constantin Isbăşoiu The system is also numerically solved with a program made in MatLAB, using a Runge Kutta method. The initial conditions are at the moment t =, when the water column velocity is v =, the displacement x = and the pressure in the pipe, p = p. Numerical computations were made for cases that correspond to the parameters of the experimental set-up, for supply head of H R =. m, water column length, l = 5 m and different orifice diameter, d (, and mm) (Fig. 7); for supply head of H R =. m, orifice diameter d = mm and water column lengths l of 5 m, m, 7 m and m (Fig. ). x 5.5 a). 5.5 5 7 9.5 x 5 b).5.5 5. x 5 c)........5.5.5 Fig. 7. Pressure oscillations for supply head of H R =. m, water column length, l = 5 m and orifice diameter d a) mm, b) mm, c) mm

Study of flow at the air water interface 9 9 x 5 a) x 5 9 b) 7 5 7 5 5 7 9 x 5 c) 5 7 x 5 d) 5.5.5.5.5 Fig.. Pressure oscillations for supply head H R =. m, orifice diameter d = mm and water column length, l a) 5 m, b) m, c) 7 m, d) m To verify the solutions gave by the two elaborated programs, a comparison between the solution obtained in the first case (with downstream end closed) and the solution obtained in the second case, with open downstream end, for which the orifice was considered A =. The results obtained with the two mathematical models are very close as showed in Fig. 9. x 5 a) x 5 b) 5 7 9 Fig. 9. Comparison for a supply head of H R =. m and water column length, l = 5 m, between a) the case with downstream end completely closed and b) the case with downstream end opened with a diaphragm diameter equal to zero.. Conclusions 5 7 9 Two mathematical models were developed to study the pressure oscillation in case of rapid opening of the intake vane. The first model considers

9 Diana Maria Bucur, Eugen Constantin Isbăşoiu the pipe closed at the downstream end and the second one considers the pipe opened with a diaphragm of area A. For both models numerical solving programs were elaborated in MatLAB. Very close results (the same pressure oscillations) were obtained with both programs for a case with common conditions. This confirms the two solutions. The two programs were run with parameters corresponding to those of the experimental set-up. In future works the mathematical models will be compared with the experimental results. The experimental set-up is located in the laboratory of the Hydraulics and Hydraulic Machinery Dpt, University Politehnica of Bucharest and will be operational from September. R E F E R E N C E S [] C.S. Martin, Entrapped air in pipelines, Proceeding of the Second International Conference on Pressure Surges, London, England,FZ- 5, 97 [] E. Cabrera, A. Abreu, R. Perez, and A. Vela, Influence of liquid length variation in hydraulic transients, ASCE Journal of Hydraulic Engineering, Vo. (), pp. 9-5, 99 [] T.K. Fok, A Contribution to the Analysis of Energy Losses in Transient Pipe Flow, A thesis submitted for the Degree of Doctor of Philosophy, University of Ottawa, 97 [] F. Zhou, F. Hicks, P.Steffler, Analysis of effects of air pocket on hydraulic failure of urban drainage infrastructure, Canadian Journal of Civil Engineering, -9, [5] D.M. Bucur, E.C. Isbăşoiu, Airpockets in pipeline systems,university Politehnica of Bucharest Scientific Bulletin, Series D, Vol. 7, No., pp 5-,