Preparation and characterisation of a sorbent suitable for technetium separation from environmental matrices

Similar documents
URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

TECHNETIUM-99 IN SOIL

Rapid Separations. Activity Radioactive Solutions. Lawrence Jassin Eichrom Technologies LLC March 3, 2008 Pittcon 2008

enable measurement. This method separates these isotopes effectively.

NICKEL-63/59 IN WATER

Determination of 126 Sn in nuclear wastes by using TEVA resin

TECHNETIUM-99 IN WATER

THORIUM, PLUTONIUM, AND URANIUM IN WATER

Analysis of Technetium-99 in Marshall Islands Soil Samples by ICP-MS

Contact Person(s) : Anna Berne APPLICATION

Uranium from water sample

TECHNETIUM-99 IN WATER

LSC for Quality Control of 99m TC Eluate from 99 Mo- 99m Tc Generator

Eichrom Technologies, Inc. Analytical Procedures Rev. 1.5 February 10, 2005 Page 1 of 9

CL Resin based methods for the separation and determination of Cl-36 and I-129 in environmental and decommissioning samples

Outline. Why Are We Concerned? More Concerns

(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)

SAFETY NOTE: Before beginning this procedure, read all of the Material Safety Data Sheets for the chemicals listed in Section 5 of this procedure.

Pu and Np-237 in seawater samples Version /03/14. Summary

ANALYTICAL SEPARATIONS GROUP

Redetermination of Low-level 99 Tc in Planchet Samples by ICP-MS

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

RADIOLOGICAL CHARACTERIZATION Laboratory Procedures

Method NumberUSTUR 150

Automation and Methodology Development for Environmental and Biological Determination of Pu, Np, U and Tc

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Determination of 210 Pb and 210 Po in Water Samples

1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter.

Rapid Methods for the Determination of Sr-90 in Steel and Concrete Samples

Ion Chromatography (IC)

AMERICIUM, NEPTUNIUM, PLUTONIUM, THORIUM, CURIUM, URANIUM, AND STRONTIUM IN WATER

Chemical synthesis (see also reaction scheme, bold underlined numbers in this text refer to the bold underlined numbers in the scheme)

Development of radiochemical analysis strategies for decommissioning activities. Dr. Daniel Zapata-García Environmental radioactivity laboratory, PTB

Sequential Isotopic Determination of Plutonium, Thorium, Americium, Uranium, and Strontium in Air-Filter Sample

ANALYTICAL TASK EXPERIMENTAL PROCEDURE

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Contact Person : Marie Lawrence APPLICATION

Determination of Cl-36 and I-129 by LSC after separation on an extraction chromatographic resin

Matrix and High Loading Effects on Eichrom Resins. Dan McAlister and Phil Horwitz Eichrom Workshop October 31, 2012

Júlio Takehiro Marumo. Nuclear and Energy Research Institute, IPEN CNEN/SP, Brazil

A Rapid Method for Determination of Uranium, Americium, Plutonium and Thorium in Soils Samples. Serdeiro, N.H. and Marabini, S.

and their Use in Food Methods

PHYSICAL CONSTANTS: MELTING POINTS, BOILING POINTS, DENSITY

Supporting Information

Rapid Analytical Methods for Determination of Actinides

Automation of the radiochemical procedures for the sequential separation of radionuclides

Rapid methods for the determination of actinides and Sr in environmental samples

Analytical Systems For NIREX Compliance

CHM 152 Lab 5: Qualitative Analysis updated May, 2011

Chem!stry. Assignment on Acids, Bases and Salts #

Particles in aqueous environments

Stoichiometry. Percent composition Part / whole x 100 = %

IGCSE (9-1) Edexcel - Chemistry

INTRODUCTION TO SOLUBILITY UNIT 3A SOLUBILITY THEORY. There are three classes of compounds which can form ionic solutions:

Rapid separation of uranium and plutonium by extraction chromatography for determination by thermal ionisation mass spectrometry

Nuclear Engineering Seibersdorf GmbH

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

General Chemistry I CHEM-1030 Laboratory Experiment No. 2 Physical Separation Techniques

Revised material in Section 4, Analytical Chemistry

The problems as we saw them were;

Experiment 1: The Borohydride Reduction of 9-Fluorenone to 9-Fluorenol

S4 CHEMISTRY SUMMARY NOTES

V. 6. Transfer Factors of Technetium-99 for Various Plants in Forests

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

4023 Synthesis of cyclopentanone-2-carboxylic acid ethyl ester from adipic acid diethyl ester

Reactions in Aqueous Solution

Procedure for determining airborne particulate uranium and plutonium in air near the ground by alpha spectrometry

2017 Reaction of cinnamic acid chloride with ammonia to cinnamic acid amide

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

Chapter 4: Types of Chemical Reactions and Solution Stoichiometry

TKI CU01 V-1.0_EN Cu separation from irradiated targets 01/12/10

Counting Solutions LSC Technical Tips from Packard

NCEA Chemistry 2.2 Identify Ions AS 91162

Liquid Chromatography

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Hints for Strong Ion Exchange Resins

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Application of Rapid and Automated Techniques in Radiochemical Analysis ---Inspirations from NKS-B Rapid-Tech Project. Jixin Qiao

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

High Performance Liquid Chromatography

An Efficient Total Synthesis and Absolute Configuration. Determination of Varitriol

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

Sample Prep Options for GC users

RECOVERY OF INDIUM FROM SPENT FLAT PANEL DISPLAY WITH SOLVENT-IMPREGNATED RESINS. K. Inoue, M. Nishiura, H. Kawakita, K.Ohto, and H.

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

SEQUENTIAL DETERMINATION OF AMERICIUM, PLUTONIUM AND URANIUM IN LIQUID EFFLUENTS FROM NUCLEAR POWER PLANTS

Analysis - HPLC A.136. Primesep 5 µm columns B.136

CHAPTER Describing Chemical Reactions Reactants Products. New substances produced The arrow means yields TYPES OF EQUATIONS.

Application Bulletin

[ Care and Use Manual ]

Procedure for determining thorium isotopes in wastewater by an extractionchromatographic

URANIUM AND THORIUM-ISOTOPES RADIOCHEMICAL SEPARATION AND QUANTIFICATION OF NORM SAMPLES BY ALPHA-SPECTROMETRY

Universal Indicator turns green. Which method is used to obtain pure solid X from an aqueous solution? A. mixture

1. Ion exchange chromatography

Production of Fluorine-18 by Small Research Reactor

Transcription:

Preparation and characterisation of a sorbent suitable for technetium separation from environmental matrices A. Bartosova, P. Rajec, M. Reich Faculty of Natural Sciences, Department of Nuclear chemistry, Mlynska Dolina CH-1, 842 15 Bratislava 4, bartosova@fns.uniba.sk Abstract An extraction chromatographic material based on Aliquat - 336 anchored on hydrophobisated silica gel support as an ion exchanger, was prepared. Prepared material for column appeared to be suitable for separation of technetium - 99 from environmental matrices. The material properties, sorption characteristic and distribution coefficient of 99m TcO 4 - in various medium was studied. The chemical yield of Tc during separation process was determinated using 99m Tc tracer and gamma measurement. Typical sorption recoveries of Tc for this sorbent from 0.1 M HNO 3 were more than 98 %. Typical desorption recoveries using 8 M HNO 3 were in the range 92 96 %. The commercial TEVA Spec resin from Eichrom Industries for comparison purpose was used as well. Prepared sorbent was conditioned with HNO 3 by washing with 25 ml of 0.1 M HNO 3. The solution containing 35 kbq of 99m TcO 4 - in 0.1M HNO 3 was passed through the column. Tc was eluted by 8 M HNO 3. The activity of 99m Tc in eluent collected in each 1 ml fraction was measured by well type NaI(Tl) detector. It was found that the prepared sorbent is suitable for separation of technetium from environmental matrices and radioactive waste. Introduction 99 Tc is an artificial long live pure beta isotope ( T 1/2 = 2.17x10 5 years ). 99 Tc is produced with high yield during nuclear fission of 235 U (~6%) and has a radiological implication and environmentally risk 1. In aqueous solutions, where no reducing agents are present, 99 Tc exists as a pertechnetate ion, TcO 4 -. Technetium in this form is very mobile in soils, ground and surface waters. 2 Technetium behaves as a nutrient analogue and may be concentrated by plants and deposited on their outer membrane. In humans and animals the pertechnate ion localizes in the gastrointestinal tract and thyroid gland. 3 Several methods have been used to determine 99 Tc in the environment 4. These methods mostly include concentration and purification step of the technetium on an ion exchange. The most commercially ion exchanger used for separation and purification of pertechnetate is TEVA Spec resin, made by Eichrom Technologies. 4 Sorption behaviour of technetium and other metal ions from nitric and hydrochloric acids using TEVA product is shown. Tc (as pertechnate anion TcO 4 - ) has higher distribution coefficient at lower acid concentration contrary to other metals. The aim of this study was to prepare cheap and effective sorbent suitable for 99 Tc determination from environmental samples especially focused on technetium separation from soils 5 and radioactive wastes.

Methods The experimental studies were designed to provide all necessary data to estimate sorption capacity, competitive ion sorption, choice of suitable medium for technetium sorption and desorption processes, properties of prepared sorbent, as well as to determine influence of typical substances appeared after leaching technetium from soil on its distribution coefficient on sorbent. The column used was the same as for TEVA Spec resin (100-150 mm in diameter, volume of 5 ml). Sorbent preparation The active component of the prepared sorbent is an aliphatic quaternary amine Aliquat-336 anchored on hydrophobisated silica gel. Properties of this sorbent are similar to typical strong base anion exchange resins. The column used in this study was constructed of plastic and was 1.5 cm in diameter and 15 cm in height (a total column volume - 5 ml). 60 g of silica gel were dried in the oven at 105 0 C. The dried up silica gel were hydrophobisated with adding twice of 100 ml of 3% solution of Lukooil H / acetone and then dried up and heated for 20 minutes at 180 0 C in an laboratory drying oven. To the dry hydrophobisated silica gel 100 ml of 40 % Aliquat -336/ benzene solution was added. After sorption of Aliquat -336 from solution to silica gel the rest of organic phase was decanted and sorbent was dried up to dryness at room temperature. The final weight of the prepared sorbent was 86 g. There were prepared sorbents with different Aliquat -336 concentration in this study. The concentration of the mixture of Aliquat-336/ benzene was in the range of 10 % - 60%. All concentrations in the range 10-60 % were used for experiments, but the most suitable concentration used for pertechnetate sorption experiments was 40 % Aliquat -336/benzene (described above) due to the highest distribution coefficient of sorbent for pertechnetate and not to be sticky. Method sumary for the sample of soils and radwastes Approximately 35 kbq 99m Tc and 2.5 Bq 99 Tc were added as a yield monitor to 10 g of soil or radwaste. Sample was wetted using 30 ml NH 4 OH and evaporated to dryness. The sample was ashed for 8 hours by 550 0 C and then leached in 50 ml 8M HNO 3 on a hotplate at 125 0 C for 2 h. Centrifuged, filtered and neutralised with 25 ml NH 4 OH until a reddish-brown precipitate was formed. Centrifuged, discard the precipitate and evaporate to dryness. Dissolved the sample in 20 ml of 0.1 M HNO 3. Then the chromatography column contained the prepared sorbent was washed with 20 ml deionised water and then with 20 ml 20 ml of 0.1 M HNO 3. The sample solution was loaded onto the sorbent and then eluated with 25 ml 8 M HNO 3. 1 ml from the eluate was taken for determination of the chemical recovery for gamma measurement of 99m Tc. The rest was evaporate to dryness on a hotplate and dissolved in 5 ml of 0.1 M HNO 3 to determine 99 Tc concentration by scintillation counting.

Results and discusion Study of the influence of various compounds for K D values of TcO 4 using prepared sorbent To determinate and estimate the influence of various ions presented in the soils, various compounds ( Al(NO 3 ) 3, FeCl 3, CaCl 2, K 2 SO 4, MgCl 2, NaCl ) were added to the 0.1 M HNO 3 and the influence of these compounds on the sorption (K D ) of the 99m TcO - 4 values was studied. Figure 1. shows the ionic influence at K D values in 0.1 M HNO 3. The influence of H 2 SO 4,seen in the figure 2., on the sorption of 99m Tc was also tested. To retain Tc onto the prepared sorbent was used 1 M H 2 SO 4 and for stripping 99m Tc was used 8M HNO 3. Fig. 1. Ionic influence at K D values of TcO 4 in 1M H 2 SO 4 medium Fig. 2. Ionic influence at K D values of TcO 4 in 0.1 M HNO 3 0 0 100 10 H 2 SO 4 K 2 SO 4 NaCl FeCl 3 MgCl 2 100 10 FeCl 3 CaCl 2 MgCl 2 NaCl K 2 SO 4 Al(NO 3 ) 3 HNO 3 1 0,01 0,1 1 10 100 w [%] 1 0,01 0,1 1 10 100 w [%] Ca 2+, Mg 2+, Na + ions in the form of chloride have no influence on the K D of pertechnate. Al 3+ - in the form of nitrate decrease K D of pertechnetate because of NO 3 anion and the effect was the same as HNO 3 with higher concentration. Fe 3+ ion has an influence on K D values of pertechnetate. With increasing FeCl 3 concentration a decrease of K D pertechnetate was observed which may be caused due to loss of pertechnate by reduction or by forming of Fe(OH) 3 precipitate. Prepared sorbents had different concentration of Aliquat 336/ benzene added in the range from 10 60 %. For determination of distribution coefficient K D 50 mg of sorbent were taken to extraction tubes with 5 ml solution containing TcO 4 in 0.1 M HNO 3. One tube containing 99m TcO - 4 only was used for determination of 99m Tc counts. Tubes were shaken in rotation shaker for 40 minutes. 1 ml aliquot from each extraction tube was taken for gamma measurement using well-type NaI( Tl ) detector. K D value for TcO 4 were higher for sorbent loaded with higher concentration of Aliquat 336 and the dependence was linear as can be seen from Fig. 3. The sorbent with the concentration 60 % Aliquat 336 / benzene was not suitable for separation process, because such prepared sorbent was sticky.

Fig. 3. K D values of 99m TcO 4 - for various concentration of prepared sorbent 3000 2500 2000 1500 500 0 0 5 10 15 20 25 30 35 40 45 w (Alq/Benzene) [%] Basic characteristics of prepared sorbent with commercial one from Eichrom TEVA are shown in Table 1. The prepared sorbent has similar properties as the TEVA Spec resin. Table 1. Characteristic of TEVA Spec resin and prepared sorbent. TEVA Prepared sorbent Stationary phase Aliquat-336 Aliquat-336 Support acryl ester modified silica gel Available particle diameters 20-50µm, 50-100µm, 100-150µm 54-160 µm Extractant loading 40 % 40 % Bed density[g/ml] 0.35 0.726 Vm, ml/ml of bed 0.68 0.7 Experimentally measured capacity 0.233 mmol Cl - /ml 0.33mmol Cl - /ml Chemical recoveries of 99m TcO 4 - shown in table 2. were measured in 1 ml of solution after each separation step by well- type NaI(Tl) detector. Table 2. Chemical recoveries of 99m TcO 4 - after separation steps Sample ashing precipitation extraction chromatography total recovery Soils1 92.4 77.7 49.5 23.2 Soils2 97.2 78.6 54.2 25.1 Radwastes1 97 73.8 65.6 37.4 Radwastes2 98 79.4 76.6 52.4 CONCLUSION Prepared sorbent is suitable for technetium separation from environmental samples prior to its beta measurement. Results from model matrices showed that this sorbent quantitative retained Tc from the 0.1 M HNO 3 sample and pertechnetate can be eluted from sorbent by 8M HNO 3 with high yield ( more then 94%). The influence of Na +, Mg 2+, K +, Ca 2+ ions on K D values for TcO 4 was not observed. Otherwise, with increasing concentration of FeCl 3 as well as Al(NO) 3 the K D values of pertechnetate is decreasing.

The results of pertechnate separation were found to be reproducible and prepared sorbent is cheap enough to be used in every laboratory. A method was tested to determine technetium-99 in environmental matrices and radioactive waste, using 99m Tc as a yield monitor. Chemical recoveries were typically in the range 23-52%. References [1] Ihsanullah, B. W. East, Application of Plasma Source Mass Spectrometry, 49 [2] T. K. Ikäheimonen, V. P. Vartti, E. Ilus, J. Mattila, Journal of Radioanalytical and Nuclear Chemistry, 252 ( 2002 ) 309 [3] D. M. Beals, Journal of Radioanalytical and Nuclear Chemistry, 204 ( 1996 ) 253 [4] Characteristic of the TEVA Resin Extraction Chromatographic material and packed columns, www.eichrom.com/ products [5] F. Wigley, P. E. Warwick, I. W. Croudace, J. Caborn, A. L. Sanchez, Analytica Chimica 380 ( 1999 ) 73