First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Similar documents
First Stage Analysis of the Energy response and resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Construction of the CALICE High Granular Scintillator Based Electromagnetic Calorimeter Prototype and Its Response to Electrons

Status of Simulation Tools for ScECAL of ILD

Electromagnetic calorimetry for the ILC

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

CALICE Test Beam Data and Hadronic Shower Models

CALICE scintillator HCAL

Status of the CALICE analog calorimeter technological prototypes

Combined Calorimeters Properties Part 1.

Validation of Geant4 Physics Models Using Collision Data from the LHC

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Digital Imaging Calorimetry for Precision Electromagnetic and Hadronic Interaction Measurements

Test setup, APDs,, preamps Calibration procedure Gain monitoring with LED Beam test results Future R&D options

Digital Calorimetry for Future Linear Colliders. Tony Price University of Birmingham University of Birmingham PPE Seminar 13 th November 2013

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Hadronic energy reconstruction in the combined electromagnetic and hadronic calorimeter system of the CALICE Collaboration

Simulation study of scintillatorbased

Dual readout with tiles for calorimetry.

G. Gaudio, M. Livan The Art of Calorimetry Lecture V. The state of art Towards ILC calorimetry

Upgrade of the CMS Forward Calorimetry

arxiv: v1 [hep-ex] 18 Feb 2009

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

SciBar and future K2K physics. F.Sánchez Universitat Aútonoma de Barcelona Institut de Física d'altes Energies

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

A study of silicon sensor for ILD ECAL

Functions Represent SiPM Response Especially Linear Behavior After Saturation

arxiv: v1 [physics.ins-det] 23 Oct 2017

Les Premières Données dans ATLAS et le Calorimètre à Argon Liquide

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

ATLAS Hadronic Calorimeters 101

Response curve measurement of the SiPM

Studies of the ATLAS hadronic Calorimeter response to muons at Test Beams

Commissioning of the ATLAS LAr Calorimeter

ATLAS Tile Calorimeter performance for single particles in beam tests

The Electromagnetic Calorimeter of the HERA-B Experiment

Simulation and validation of the ATLAS Tile Calorimeter response

Calorimeter test-beam results with APDs

First Data Quality of the CALICE Test Beam 2008

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

5 Hadronic calorimetry

Characterisation of Silicon Photomultipliers for the T2K Experiment

NA62: Ultra-Rare Kaon Decays

ATLAS Tile Calorimeter Calibration and Monitoring Systems

What detectors measure

Study of TileCal Sampling Fraction for Improvement of Monte-Carlo Data Reconstruction

Muon reconstruction performance in ATLAS at Run-2

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

Information about the T9 beam line and experimental facilities

Calorimetry in particle physics experiments

LHCb Calorimetry Impact

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

A gas-filled calorimeter for high intensity beam environments

ABSTRACT RESULTS OF BEAM TESTS OF A PROTOTYPE CALORIMETER FOR A LINEAR COLLIDER

Calorimeter for detection of the high-energy photons

Calibration and Performance of the ATLAS Tile Calorimeter During the LHC Run 2

Calorimetry I Electromagnetic Calorimeters

arxiv: v2 [nucl-ex] 6 Oct 2008

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

7th International Conference on New Developments In Photodetection

ATLAS NOTE October 12, 2009

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

Performance of the MCP-PMT for the Belle II TOP counter

Identifying Particle Trajectories in CMS using the Long Barrel Geometry

The First Large Application of MPPC: T2K Neutrino Beam Monitor INGRID

arxiv: v1 [physics.ins-det] 22 Dec 2013

Particle Flow Algorithms

The reaction p(e,e'p)π 0 to calibrate the Forward and the Large Angle Electromagnetic Shower Calorimeters

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

FoCal Project in ALICE. Yota Kawamura for the ALICE FoCal collaboration TCHoU workshop 2018/3/15

Digital Hadron Calorimetry for the Linear Collider using GEM Technology

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

The Fast Interaction Trigger Upgrade for ALICE

Granularity of ATLAS Tile Calorimeter studied through simulations

HL-LHC Physics with CMS Paolo Giacomelli (INFN Bologna) Plenary ECFA meeting Friday, November 23rd, 2012

Photons: Interactions

ATLAS EXPERIMENT : HOW THE DATA FLOWS. (Trigger, Computing, and Data Analysis)

MINOS. Physics Program and Construction Status. Karol Lang The University of Texas at Austin. YITP: Neutrinos and Implications for Physics Beyond

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

CsI Calorimeter for KOTO experiment

New Results from the DREAM project

Available online at Physics Procedia 37 (2012 )

Electroweak Physics at the Tevatron

MEG II 実験の準備状況と 今後の展望 東京大学 素粒子物理国際研究センター 岩本敏幸 他MEG II コラボレーション 2018年9月14日 日本物理学会2018年秋季大会 信州大学 JSPS Core-to-Core Program

Fermilab FERMILAB-Conf-00/342-E CDF January 2001

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

PoS(ICHEP2016)293. The LArIAT experiment and the charged pion total interaction cross section results on liquid argon. Animesh Chatterjee

Adam Para, Fermilab CALOR2010, IHEP, Beijing May 14, 2010 TOTAL ABSORPTION HOMOGENEOUS CALORIMETER WITH DUAL READOUT

arxiv: v1 [hep-ex] 6 Jul 2007

Dual-Readout Calorimetry with a Mo-Doped PbWO4 Electromagnetic Section

Preliminary results from gamma-ray observations with the CALorimeteric Electron Telescope (CALET)

GEANT4 simulation of the testbeam set-up for the ALFA detector

Particle detection 1

Particle Identification Algorithms for the Medium Energy ( GeV) MINERνA Test Beam Experiment

A Calorimeter with Resistive Plate Chambers José Repond Argonne National Laboratory

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

THE AMS RICH COUNTER

Missing Transverse Energy. Performance with CMS

Transcription:

1 2 3 4 First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 28 The CALICE collaboration November 22, 29 5 6 7 8 9 11 12 13 14 This note contains preliminary results of the ScECAL beam test at Fermilab meson test beam line in September 28 and is for the use of members of the CALICE collaboration. Abstract A beam test of the ScECAL prototype module has been performed in the period Aug 19 - Oct 4 28 at FNAL meson beam test facility. This beam test is the first comprehensive beam test for the ScECAL combined with Analog ScHCAL using 1-32 GeV electron, pion and muon beams. As a preliminary result of the first stage analysis, we obtain for the ScECAL a relative energy resolution for single electrons of σ E /E = (1.44±.2)% (15.15±.3)/ E beam (GeV )%, with the quoted uncertainty purely statistical. The deviation from the perfect linear response is found to be less than 6%. 15 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3 31 32 33 34 35 36 37 1 Introduction The International Linear Collider (ILC) experiments are designed to perform high precision measurements using the clear initial states of the electron-positron collider and well reconstructed final state. To characterize final states dominated by gauge bosons and quarks, the reconstruction of jets is one of the key issues. One of the ways to precisely reconstruct jets is to identify and to measure individual particles within jets, by combining calorimetry and tracking. This method, called particle flow approach (PFA) requires highly granular calorimeters. In particular, in the Letter of Intent of ILD[1] recently released, the granularity of the electromagnetic calorimeter (ECAL) is required to be finer than 1. 1. segmentation. The Scintillator ECAL (ScECAL) is one of the proposed concepts for a highly granular ECAL for the ILC, which is designed to have an effective 1 1 lateral segmentation using 1 4.5 scintillator strip. In order to achieve the required 1 1 lateral segmentation, the strips in odd layers are orthogonal with respect to those in the even layers. The proposed detector is a sampling calorimeter, with sensitive layers made of 2 mm thick plastic scintillator and 3 mm thick absorber layers. The scintillation photons are collected by a wavelength shifting (WLS) fiber, inserted centrally, along the longitudinal direction of each scintillator strip and are read out with a Pixelated Photon Detector (PPD). A first ScECAL prototype had a transverse area of 9 9 area and 26 scintillator layers in between 3.5 mm thick tungsten-cobalt absorber layers[2, 3, 4, 5]. The total number of radiation lengths was 18.5. This first prototype of the ScECAL was tested using 1-6 GeV/c positron beams at DESY in March 27. The deviation from the linear behavior of energy response is less than 1% indicating the good linearity in this energy region. The stochastic term of the energy resolution curve, 14%, shows good energy resolution. However, the constant term of the energy resolution 1

38 39 4 41 42 43 44 45 46 47 48 49 5 51 52 53 54 55 56 57 58 59 6 61 62 curve is found to be 3%. This is rather large and likely due to shower leakage and non-uniformities in the response of strips. The importance of the non-uniformities in the response is corroborated by the analysis of the first testbeam data which showed that the constant term depends on the beam position on the prototype front-face. At the center of the ScECAL surface, the near PPD sides and the other sides of scintillators are adjacently aligned. Therefore, the sensitivity is drastically changed in a small area, when we use the scintillator strips whose sensitivity decreases as the position is away from the PPD. On the other hand, on a position which defined as 2.25 away from the center in both horizontal and vertical directions, the sensitivity is stable with positions even if we use such scintillators. The former is called central region and the latter is called uniform region. The constant term is larger when the beam is aimed into the central region and much smaller when it is aimed into the uniform region [3]. Consequently, spacial care was taken improving the second prototype in order to make uniformity of the response along the strips. The technical improvements will not be described here, however, they will make the object of a future note. The second prototype was build, transversally twice as large as the first prototype, 18 18. The number of layers has been also increased to 3, leading to a total of 21.3 radiation lengths for the whole prototype. Hereafter we denote the ScECAL prototype as the second prototype. In September 28 and May 29 at FNAL, the ScECAL prototype was exposed to electron and hadronic beams up to 32 GeV/c together with the analog scintillator hadron calorimeter (AHCAL) and the Tail Catcher in order to evaluate the combined performance. This note briefly explains the analysis to evaluate the linearity and resolution of the energy measurement by the 2nd ScECAL prototype using only electron beams data taken at FNAL in September 28. The results in this note are very preliminary, because they are estimated without any systematic uncertainty. More detail and comprehensive analysis results will follow in consecutive analyses near future. Figure 1: Photograph of the ScECAL test module in front of AHCAL. First absorber layer of the ScECAL can be seen on the photo. 63 64 The outline of this note is as follows. In Section 2 the detailed description of the ScECAL tested at FNAL is given. The beam line and detector setup are described in Section 3. The 2

67 analysis including the calibration of each strip, the PPD saturation correction and event selection is described in Section 4. The results on the linearity and the energy resolution are given in Section 5 and discussed in Section 6. Finally, summary and outlook are presented in Section 7. 68 2 65 66 The ScECAL Second prototype Figure 2: Right: structure of the ScECAL test module in Sep 28 at FNAL. Left: picture of a sensitive layer showing the MPPC housing (a), the scintillator strip hermetically covered by KIMOTO reflector (b), and holes to introduce LED light for the gain monitoring system (c). 83 A photograph of the FNAL beam-test setup, with the ScECAL prototype in the beam-line in front of the AHCAL and the Tail Catcher is shown in Figure 1. The transverse size of the ScECAL module is 18 18 and the depth 26. The layered structure is visible in Figure 2, left: it has 3 pairs of scintillator and absorber layers with thickness of 3. mm and 3.5 mm respectively. The absorber is made of 88% tungsten, 12% cobalt and.5% carbon, and has Molie re radius of mm. Each scintillator layer has 18 4 scintillator strips of size is 4.5 1., made by extrusion method at Kyungpook National University (KNU). Each scintillator strip is hermetically covered with the reflecting film made by KIMOTO co. In successive scintillator layers, the strips are alternately aligned vertically ( X layers) and horizontally ( Y layers). The coordination in this note is the right hand system and z direction is paralleled with beam direction. The WLS fibers placed in the center of each strip to collect the scintillation photons are Kuraray Y-11 double clad type. They are read out with PPDs made by Hamamatsu KK, the 16-picel MPPCs. We measured the gain, capacitance, dark noise and breakdown voltage for them. The MPPCs were then soldered on a flat cable, and mounted in a housing in the end of each scintillator strip. The total number of readout channels for the ScECAL prototype is 216. 84 3 69 7 71 72 73 74 75 76 77 78 79 8 81 82 85 86 87 Beams and the experimental setup The beam test has been performed at the MT6 experiment area in the Meson Test Beam Facility (MTBF) of FNAL. Electron and charged pion beams with an energy between 1 GeV to 32 GeV were used. Muon beams at 32 GeV were also provided for MIP calibration. 3

Table 1: A list of trigger systems for particles including the pressure of C erenkov counter. 88 89 9 91 92 Particle p(gev/c) muon electron electron electron electron electron electron electron 32 1 3 6 12 16 25 32 Trigger 2 2 C erenkov pressure 345 hpaa (outer) 345 hpaa (outer) 345 hpaa (outer) 138 hpaa (outer) 138 hpaa (outer) 138 or 3 hpaa (outer) 3 hpaa (outer) The setup of the beam line is shown in Figure 3. For trigger purpose, a C erenkov counter placed upstream the experimental area was used, together with some combinations of plastic scintillators of different sizes. A pair of 2 2 trigger counters was used for the muon runs whereas for pion and electron runs, the trigger counters are. The combinations of trigger counter and the pressure of the C erenkov counter for the particles are listed in Table 1. Figure 3: Configuration of the beam line at the MT6 in FNAL. a shows the ScECAL, b shows AHCAL and c shows the Tail catcher. 93 94 95 96 The electron beam momentum was tuned at 1, 3, 6, 12, 16, 25, 32 GeV/c. Momentum spread of the provided beams is.2%[6]. Beams were injected into the central and uniform regions of the ScECAL (Section 1), respectively, in order to check the improvement in uniformity for the scintillator response. 4

97 98 99 1 2 3 4 5 6 7 8 9 1 111 112 113 114 115 116 4 Analysis 4.1 Detector calibration with MIP-like particles The first step in the analysis is the calibration of the strips using muons in order to measure the energy deposits by a Minimum Ionizing Particles (MIPs). This analysis gives the converting factor between ADC counts and the number of MIPs. The muon-tuned beam contains almost no electrons or pions because of the iron dumper put on beam line upstream of our experiment site. Therefore, the MIP events are only required to have the same X and Y hit position of channels at least in different X and Y layers, respectively. A hit is defined as a signal larger than the mean value of the pedestal by at least three standard deviations of the pedestal. For each channel, the MIP response is obtained by fitting the distribution of the charge deposited by the MIP-like events, in ADC counts, with a Landou function convoluted with a Gaussian function. The MIP calibration factor is the most probable value (MPV) of the distribution. Four typical charge distributions for MIP events are shown in Figure 4. The distribution of MIP calibration factors of 216 channels is shown in Figure 5. The averaged MIP calibration factors of 216 channels is 16 ADC counts. It is significantly larger than the corresponding standard deviation of the pedestal which is 15 ADC counts. Statistical uncertainty of the MIP response on each channel is less than.6% even in the worst channels. There are five dead channels due to broken photo-sensors or too high levels of background noise. The dead channels are either in the half of the ScECAL which is furthest downstream or on the side of the calorimeter. Therefore, the contribution of the dead channels to the energy measurement is negligible. Figure 4: Typical ADC charge distributions for MIP events in four different strips. The purple lines show the fitting result by a Landau function convoluted with a Gaussian function. The blue lines show the mean values of pedestal peaks. 5

Figure 5: The distribution of MIP calibration factors of 216 channels. 117 118 119 12 121 122 123 4.2 The correction of MPPC saturation The MPPC response has a saturation behavior according to its intrinsic property. Prior to the FNAL beam test, the MPPC saturation was measured on a test-bench, for which the setup is presented in Figure 6. A strip similar as the ones used for the prototype module was illuminated with a pico-second laser pulse. The photons which came through one of two cross sections of the WLS fiber in the strip were read out by a MPPC and the photons which came through the cross section on the other side, were read out by a PMT. PC Pulse Generator Programmable Delay Gate Generator ADC ns Gate Ch.1 Ch.2 Voltage Power Supply Vover : 3 V H.V. Power Supply 8 V Polarized Filter Controller MPPC PMT Laser Controller Pico-sec Light Pulser ( 4nm,Violet) Thermostatic Chamber (25 ) Figure 6: Setup of the response curve measurement using pico-second laser system, the scintillator strip and the MPPC. 6

Figure 7 shows the MPPC response as a function of absolute amount of photons measured by photomultiplier. It indicates that the saturation of response of MPPC appears in a region of large light input. This saturation behavior is represented by; Figure 7: The response of MPPC as the function of PMT in ADC counts. Red line shows the fitting result by Eq. 1 ( ϵnin )) N fired = N pix (1 exp, (1) N pix 124 125 126 127 128 129 13 131 132 133 134 135 136 137 138 139 14 where N fired is the number of photons detected by MPPC, N pix is the number of pixels on the MPPC, ϵ is the photon detection efficiency and N in is the number of photons incident in the MPPC sensitive area. By fitting Equation 1 to the MPPC vs PMT curve in Figure 7, the fitting parameter N pix is determined to be 2424 ± 3. The actual number of pixels is 16. We think this result shows that the photon generation in the scintillator has a time duration which allows some pixels to be active again in the allocated time window, hence allowing to be hit more than once in an event. In order to apply the correction for each channel, we use the inverse function of Equation 1. The input of the function, N fired should be an absolute number of photons as the output signal of the relevant channel. Therefore, the ADC counts of the output signals of the strip should be converted to the number of photons. To convert the ADC counts to the number of photons, the ratio of the ADC counts per photon for each channel has to be known. An LED calibration system to get such ADC-photon ratio was embedded in the prototype module and the LED calibration runs were implemented. The ADC-photon rations for the respective channels are obtained as the averages of the half of every data acquisition days. For 3% of all channels, the LED calibration system had problems. Therefore, the average of the ADC-photon ratios of all available channels are used for such channels. The details for the LED calibration will be discussed in the consecutive notes which will follow this result in near future. 7

2 4 5 1 c c 1 5 c c c 2 c / c 2 5 e su m 141 142 143 4.3 Energy spectra Using the set of calibration factors obtained in Section 4.1, the deposited energy is obtained in MIP units by summing the calibrated response over all strips; E total = 3 72 l=1 s=1 E ls /c ls, (2) 144 where i and s are the layer and strip indices, E ls is the measured energy corrected for MPPC saturation and c ls is the calibration factor on a corresponding strip. The corrected measured 145 146 147 148 149 15 151 152 energy, E ls is obtained as the following; ( E ls = n pixr ADC photon,ls log 1 N ) ADC,ls/R ADC photon,ls, (3) n pix where n pix is the effective number of pixels and R ADC photon is the ratio of ADC counts to the number of detected photons for each strip, both n pix and R ADC photon were obtained in the Section 4.2, and N ADC,ls is the number of ADC counts as the response of each strip. The spectra of the deposited energy for several beam momenta are shown in Figure 8. These spectra include some contaminations of pions and muons. In Section 4.4, the selection of the electrons from these sample is described. Counts / 27.5 MIPs 1 GeV 3 GeV/ 6 GeV/ 12 GeV/ 16 GeV/ 25 GeV/ 32 GeV/ Deposit-enegy in ScECAL (MIPs) Figure 8: The energy spectra on the ScECAL after the calibration and MPPC saturation correction without any cuts to select electron events. 153 154 155 4.4 Purification of electron events The selection criteria to purify the electron events are as follows: 1. the shower maximum in the ScECAL should be upstream with respect to the 2th layer, 8

156 157 158 159 16 161 162 163 164 165 166 167 168 169 17 171 172 173 174 2. the deposited energy on the shower maximum layer in the ScECAL should be greater than; MIPs for 1 GeV/c, 2 MIPs for 3 GeV/c, 4 MIPs for 6 GeV/c, 8 MIPs for 12 GeV/c, MIPs for 16 GeV/c, 15 MIPs for 25 GeV/c, and 2 MIPs for 32 GeV/c, 3. the deposited energy on the shower maximum layer in AHCAL should be less than 2 MIPs, 4. the deposited energy on the most downstream layer of AHCAL should be less than.4 MIPs, 5. and 6. the gravitational center of electromagnetic shower in ScECAL should be within ±4 from the ScECAL center in the x and y direction, respectively. The first three selection criteria are meant to reject pions, 4th is to reject muons and 5th and 6th are to reject the events which have shower leakage to the side surface of the detector. Figure 9 left shows the effect of cuts and Figure 9 right shows the shape of the spectrum after all cuts for one of the 25 GeV/c runs. The spectrum is fitted well with a Gaussian function in the range including 9% of the function area, i.e. between ± 1.65 σ. On the other hand, the similar distribution for the 1 GeV/c runs show that pions remain in lower energy region of the electron peak. We discuss this issue more in Section 5.2 and Section 6.2. Figure 9: Effect of cuts on the 25 GeV events in a run (Run63533), left. Black histogram shows the energy distribution before any cuts, sky blue and purple histograms show the effect of the first cut and the 1st + 2nd cuts, respectively, and yellow shows the effect of 1st - 3rd cuts, but events remain with additional 4th - 6th(red) cuts are almost same as the after 1st - 3rd cuts. Right plot shows the spectrum after all cuts and the red curve shows the fitting results. 175 176 177 For every selection cut, we investigate the variations of the deposited energy in the ScECAL prototype and its resolution when changing the cut values. The deposited energy is determined as the mean value of the fitted Gaussian function. The stability of the deposited energy in the 9

e so l u t i o E n e r g y r n D e p o s i t e n e r ( % ) 3. 2 3. 4 3. 6 178 179 18 181 182 183 184 prototype with the selection on the shower maximum can be seen on Figure for 32 GeV electrons. Nominally, the shower maximum is required to be upstream layer 2 and when no such cut is applied (cut value fixed to 31 in the figure), the mean deposited energy varies by less than.5% and the energy resolution by less than.5%. This suggests that the cut does not induce any significant bias due to the rejection of the large electromagnetic showers. It was checked that for any of the applied selection criteria and for all beam momenta, the stability of the deposited energy is better than.1% and the resolution stability better than 1%. Ratio of mean of E( varied cut/nominal cut ) 1.6 1.4 1.2 1.9998.9996.9994 15 2 25 3 Cut on Max.-energy-layer in ECAL Ratio of sigma of E( varied cut/nominal cut ) 1.1 1.5 1.995.99 15 2 25 3 Cut on Max.-energy-layer in ECAL Figure : Cut variation of deposited energy on the shower maximum cut (left) and cut variation of the energy resolution on the same cuts (right). The nominal cut value is 2th layer. 185 4.5 Variation of deposited energy depending on Run g y i n ( M L I P ) E CA 3 4 3 6 1 2 3 4 5 6 7 1 2 3 4 5 6 7 3 8 Run 53533 Run 53532 Run 53531 Run 5352 Run 53519 Run 53518 Figure 11: Run variations for 25 GeV/c runs. Left shows the deposited energies with their statistical uncertainties. Although each uncertainty is represented with a horizontal bar, it is too small to appear in the plot. Right shows their resolutions. 186 187 The variation of the deposited energy and of the energy resolution over different 25 GeV electron runs is shown in Figure 11, where the uncertainties are statistical only. Although the

188 189 19 191 192 193 194 195 196 197 198 199 2 21 22 23 24 25 fluctuation of the resolution is consistent with statistical fluctuations, this is not the case for the deposited energy, which seems to be affected by large systematic uncertainties, still under investigation. To avoid this systematic uncertainty in the energy resolution, we calculate the resolution for each beam momentum as the weighted average of resolutions for respective runs. Without any systematic uncertainty, we use the same way for the calculation of the deposited energy in this note. For all beam momenta, such behaviors exist. The details will be discussed in Sections 5 and Section 6. 5 Results 5.1 Linearity of energy response Figure 12 shows the deposited energy in the ScECAL prototype as the function of beam momentum. The lines are results of linear fitting. The red line and dots are for the uniform region beam incidence, the blue line and dots are for the center region beam incidence, and the black line and dots show the combined results. There is no significant difference between the results for the uniform region and the center region. Although Figure 12 shows the almost good linearity, the deviations from the linear behavior in Figure 13 shows that the linearity is not enough ( < 6% ). A possible reason of this variation is gain variation of photo-sensor by temperature change. We will apply the temperature correction in the next note. The other origins of the deviation are discussed in Section 6. Deposit energy in ECAL (MIP) 5 4 3 2 Slope = 145.28 ±.1 ( combined ) Slope = 147.83 ±.1 ( center ) Slope = 142.37 ±.1 ( uniform ) 2 3 Beam momentum ( GeV/c ) Deviation from linear (%) 2 15 5-5 - -15-2 2 3 Beam momentum ( GeV/c ) Figure 12: The deposited energy in the ScECAL as the function of the beam momentum. The lines show the results of linear fitting with forced zero offset. The red line and dots are for the uniform region beam incidence, the blue line and dots are for the center region beam incidence, and the black line and dots show the combined results. Figure 13: Deviation from the linear behavior of the deposited energy as the function of the beam momentum. 26 27 28 5.2 Resolution of energy response Figure 14 shows the resolution of the deposited energy in the ScECAL prototype as the function of beam momentum. Again, the red line and dots are for the uniform region beam incidence, the 11

Table 2: The constant numbers of the terms of resolutions for the center region, uniform region, and combined results. Region Constant(%) Stochastic(%) Center 1.59±.3 14.8±.4 Uniform 1.21±.4 15.67±.5 Combined 1.44±.2 15.15±.3 29 2 211 212 213 blue line and dots are for the center region beam incidence, and the black line and dots show the combined results. The lines are fitting results with the function of; σ E = σ 1 constant σ stochastic Ebeam (GeV ), (4) where, E is the deposited energy, σ is the standard deviation of the fitted Gaussian function, and σ constant and σ stochastic are the fitting parameter for this function, and E beam is the beam energy. Table 2 shows obtained fitting parameters for the uniform region, center region and combined. / E (%) σ E 2 18 16 14 12 8 6 4 2 const. = 1.44 ±.2 ( combined ) stat. = 15.15 ±.3 const. = 1.59 ±.3 ( center ) stat. = 14.8 ±.4 const. = 1.21 ±.4 ( uniform ) stat. = 15.67 ±.5.5 1 1/ P beam ( GeV -1/2 /c -1/2 ) Figure 14: The resolutions of ScECAL response of energy as the function of beam momentum. The red curve and dots are for the uniform region beam incidence, the blue curve and dots are for the center region beam incidence, and the black curve and dots show the combined results. 214 215 216 217 218 219 22 The uncertainties in Table 2 are only statistical uncertainties. Although the constant term for the uniform region is smaller than for the center region, the small constant term for the uniform region is rather made by the larger resolution values at small beam momenta less than 6 GeV, because of the correlation between the constant term and stochastic term of the resolution. Additionally, between the uniform region and the center region, there is almost no difference of the resolution at beam momenta greater than 12 GeV. Therefore, the performance of the center region is not worse or rather better than the performance of the uniform region. 12

221 222 223 224 225 226 227 228 229 23 231 232 233 234 235 236 237 238 6 Discussions 6.1 Linearity of energy response The fluctuation of the deposited energy between runs induces a large systematic uncertainty in the deposited energy. One of the possible reason of this fluctuation is the effect of the temperature variation of the detector. The temperature monitoring was implemented during the data taking, and overall effect of temperature variation on each channel was investigated in May 29 beam test. It changes MIP calibration factors by 3.5% per one Kelvin. However the temperature data in September 28 had problems that it sometimes did not work or had large noise. Therefore, we are still trying to recover the temperature data. The MPPC saturation correction is applied using a Equation 3 with only one parameter; the number of the effective pixels, n pix. This number is larger than the actual number of pixels, 16, because the timing structure of incoming photons allows some pixels to become active again during the event. Since there is a possibility that the timing structure is depending on the deposited energy and the incident particle species, the behavior of MPPC saturation should be studied in more detail and the systematic uncertainty from MPPC correction should be estimated. Another possible origin of the deviation is some energy leakage toward lateral sides and the downstream. We will investigate the detail of the leakage in the near future. 6.2 Resolution of energy response 246 239 There is no significant difference between the energy resolution for the uniform region and the 24 center region. This result indicates that the uniformity of response of the scintillator strips has 241 been improved from the prototype used at DESY. The constant term is reduced by a factor two 242 with respect to the previous prototype. 243 The reduced χ 2 of Gaussian fitting to the every spectra are almost around one and a few 244 runs have 1.5 but less than two. However, for one GeV/c beams, the average of the reduced χ 2 245 is 2.7 because of their leading peaks. The beam at FNAL beam test includes both pions and electrons. Although we used the Ĉerenkov counter to select particles, the electron beam includes 247 an amount of pions. Especially for 1 GeV beam, pion rejection is difficult and the samples after 248 all cuts still include pions. We confirmed that the resolution decreases as the region of Gaussian 249 fitting decreases. The systematic uncertainty from this uncertainty should be estimated and more 25 effective cuts to reject pions are needed in the next step. 251 252 253 254 7 Summary and outlook The ScECAL beam test has been performed using pion - electron mixed beam in the momentum range 1-32 GeV/c. As a result of the first-stage analysis, the energy resolution combined the uniform region and the center region is found to be; σ constant = 1.44 ±.2% (5) σ stochastic = 15.15 ±.3% (6) 255 256 257 258 Deviations from linear behavior of the energy measurement are found to be less than 6%. However, these results are very preliminary because they are estimated without any systematic uncertainties. We already found some behaviors suggesting the presence of systematic uncertainties. Several effects need to evaluate these uncertainties and they are listed in the following; 13

259 26 261 262 263 264 265 266 267 268 269 27 271 272 273 274 275 276 277 278 279 28 281 282 283 284 285 286 287 288 289 29 291 292 293 Variation by the temperature should be estimated and corrected. The pion contamination should be reduced with more effective selection criteria and the systematic uncertainty from the pion contamination should be estimated. More precise MPPC saturation correction should be studied and the systematic uncertainty from the correction is needed. Significant variation of the deposited energy in runs should be understood and corrected. The effect of wide distribution of MIP calibration constants on the energy resolution and the systematic uncertainty from this variation should be studied. The energy leakage and the uncertainty from the leakage should be estimated. To study these problems, a comparison of the data to the results of a realistic Monte Carlo simulation is necessary. Moreover, we took the other data set in both September 28 and May 29 for the studies as the following; to study the influence of the incident angle of particles, tilted detector runs were implemented, to study the performance on two particle separation, neutral pion runs were implemented, to study the detail position dependence of response, the beam position was precisely changed in some runs, and to study the performance of the combined detector, ScECAL, AHCAL, and Tail catcher, charged pion beam runs were implemented. Analyses for these data set are ongoing or will be started. References [1] ILD Concept Group, The International Large Detector Letter of Intent (29). [2] CALICE analysis note 5. The scintillator ECAL beam test at DESY, 27 - First results. http://www.hep.phy.cam.ac.uk/ drw1/analysisnotes/can-5/can-5.pdf [3] CALICE analysis note 6. The scintillator ECAL beam test at DESY, October 29, 27 - Update 1. http://www.hep.phy.cam.ac.uk/ drw1/analysisnotes/can-6/can-6.pdf [4] CALICE analysis note 7. The scintillator ECAL beam test at DESY, April 8, 28 - Update 2. http://www.hep.phy.cam.ac.uk/ drw1/analysisnotes/can-7/can-7.pdf [5] CALICE analysis note 12. The scintillator ECAL beam test at DESY, June 4, 28 - Update 3. http://www.hep.phy.cam.ac.uk/ drw1/analysisnotes/can-12/can-12.pdf [6] Private discussion with the run coordinator of the beam control room of FNAL. 14