ApplicationNOTE Abstract

Similar documents
ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

IN QUALITATIVE ANALYSIS,

Investigating Source, Age, Maturity, and Alteration Characteristics of Oil Reservoirs Using APGC/MS/MS Analysis of Petroleum Biomarkers

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

[ Care and Use Manual ]

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

2017 Source of Foreign Income Earned By Fund

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

ANALYSIS OF BASIC COMPOUNDS

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Keysight Technologies Oxygen-Free High-Resolution Electrochemical SPM. Application Note

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

This document is a preview generated by EVS

Quick Guide QUICK GUIDE. Activity 1: Determine the Reaction Rate in the Presence or Absence of an Enzyme

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

of mass spectrometry

Microbial DNA qpcr Multi-Assay Kit Clostridium perfringens Pathogenicity

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Keysight Technologies Instrumented Indentation Testing with the Keysight Nano Indenter G200. Application Note

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

EXPRESSION MORE PEPTIDES. MORE PROTEINS. MORE REPRODUCIBILITY. MORE QUANTIFICATION.

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Appendix B: Detailed tables showing overall figures by country and measure

Global Data Catalog initiative Christophe Charpentier ArcGIS Content Product Manager

READY TO SCRAP: HOW MANY VESSELS AT DEMOLITION VALUE?

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Export Destinations and Input Prices. Appendix A

PosterReprint INTRODUCTION

Keysight Technologies Measurement Uncertainty of VNA Based TDR/TDT Measurement. Application Note

Mathematics. Pre-Leaving Certificate Examination, Paper 2 Higher Level Time: 2 hours, 30 minutes. 300 marks L.20 NAME SCHOOL TEACHER

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

1.7µm Fortis C18 UHPLC Columns

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Highly Sensitive and Rugged GC/MS/MS Tool

GC-MS. Commonly done on low resolution (1 dalton) quadrupole instruments in the selected ion (mass) mode. e.g. Hewlett-Packard MSD, VG Trio and

GC-APCI IMS of Diesel

Introduction to Fourier Transform Infrared Spectroscopy

U.S. EPA Method 8270 for multicomponent analyte determination

Nigerian Capital Importation QUARTER THREE 2016

Author. Abstract. Introduction

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

ORGANISATION FOR ECONOMIC CO-OPERATION AND DEVELOPMENT

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

MetWorks Metabolite Identification Software

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

04 June Dim A W V Total. Total Laser Met

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Introduction to GC/MS

Monitoring Protein PEGylation with Ion Exchange Chromatography

Keysight Technologies Measuring Substrate-Independent Young s Modulus of Low-k Films by Instrumented Indentation. Application Note

[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly.

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

2006 Supplemental Tax Information for JennisonDryden and Strategic Partners Funds

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

AN1755 APPLICATION NOTE

IDENTIFICATION OF ORGANOMETALLIC COMPOUNDS USING FIELD DESORPTION IONIZATION ON THE GCT

Bilateral Labour Agreements, 2004

A Prior Distribution of Bayesian Nonparametrics Incorporating Multiple Distances

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

protein interaction analysis bulletin 6300

ENVIRONMENTAL analysis

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Cyclone Click to go to the page. Cyclone

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Introduction to Fourier Transform Infrared Spectroscopy

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Keysight Technologies Young s Modulus of Dielectric Low-k Materials. Application Note

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

[ XEVO G2-XS QTOF ] EXTRAORDINARY POSSIBILITIES FOR YOUR EVERYDAY ANALYSIS

Transcription:

Abstract It has long been known that a range of non-native, stable, saturated hydrocarbon biomarkers present in crude oil extracts could be used to identify the original facie from which the oil was formed. Routine analysis is completed using Gas Chromatography (GC) with Mass Spectrometric (MS) detection using a single quadrupole analyser. Selective Ion Recording (SIR) of the 217Da fragment ion is used to identify the steranes of interest. However, this type of analysis is prone to interferences from other families of compounds found in rock oil extracts including hopanes, methyl steranes and bicadinanes. In this paper we will show, through the use of a Waters Micromass Quattro micro GC triple quadrupole mass spectrometer, that specificity can be improved through the use of GC/MS/MS to selectively identify branched steranes (and hence the rock oils facie) while eliminating interferences seen during SIR analysis. THE IDENTIFICATION OF SOURCE ENVIRONMENT FROM THE ANALYSIS OF ROCK OIL EXTRACTS UTILIZING THE HIGH SELECTIVITY OF TRIPLE QUADRUPOLE GAS CHROMATOGRAPHY/MASS SPECTROMETRY David S. Douce 1, Peter Abohlin 2 & Awang Awang Sapawi 2, 1 Waters Corporation, Atlas Park, Simonsway, Manchester, M22 5PP, UK 2 Petronas Research and Scientific Services, Off Jalan Ayer Itam, Kawasan Institusi Bangi, 43000 Kajang, Salangor Darul Ehsan, Malaysia Steranes are one such group of biomarkers. These have been identified as the resultant saturated skeletal backbones of sterols found to be present in a number of higher plants (terrigenous) and algae (sea and fresh water associated). Figure 1 shows the structural backbone and the respective side groups for C27- C30 steranes. The key shows the variation in carbon chain length which is used to determine the organism and hence environment from which the oil was produced (1,2). X=H C27 sterane is ubiquitous in all organic matter X=CH 3 C28 sterane algal (fresh water or marine)/bacterial contribution X=C 2 H 5 C29 sterane Terrigenous (higher plant) material Introduction The use of biomarkers for the specific identification of the environment (ecosystem) from which oil is produced has become an important issue in recent years. Such biomarkers can be produced from organic compounds present in the original organic source material. Some of these compounds are converted through a number of complex chemical reactions during diagenesis. Diagenesis is a low temperature process prior to deep burial and thermal maturation. During this process the reduction of oxygen moities and unsaturated regions result in the production of non native, stable, saturated hydrocarbon biomarkers in crude oil. These biomarkers can be used to identify the original organic molecule and hence identify the source organism. This ultimately results in the identification of the environment (facies) from which the oil was produced. X=C 3 H 7 C30 sterane algae from a marine environment Figure 1. The sterane structure, relevant side chain length, the associated organism and hence environment from which the compound was produced. These trace components from crude oil source rock extracts can be difficult to specifically identify due to the complexity of the extract. The current method used for sterane analysis is GC/MS (single quadrupole instrument) using Selective Ion Recording (SIR) of a known fragment (217 Da) from the sterane molecule. However, it is known that a number of compounds, e.g. bicadinanes from tree resins, hopanes and methyl steranes, can co-elute with many of the steranes, and produce a fragment ion of 217 Da. These compounds can be at much higher concentrations than the steranes of interest swamping the signal and making the unambiguous identification of these biomarkers difficult.

Experimental Two South East Asia samples were prepared for analysis from significantly different facies, these were a marine ecosystem and a terrigenous (higher land plant) ecosystem. The source rock was solvent extracted and the resulting residue was fractionated by polarity to produce a non-polar hexane fraction. The samples were analysed on an Agilent 6890 GC attached to a Waters Micromass Quattro micro GC triple quadrupole mass spectrometer operated in EI+ mode (Figures 2 & 3). The samples were injected splitless (1ul injection). Helium was used as carrier gas with a constant flow rate of 1.0 ml/min. The injector temperature used was 250 C. The GC capillary column employed was a J&W Scientific DB-5MS column, 30 m x 0.25 mm i.d. x 0.25 um film thickness. The temperature of the transfer line was held at 280 C during the chromatographic run. The temperature ramp rate employed was 120 C (1min hold) to 300 C (8 minutes hold) at 15 C/min, producing a total run time of 38 minutes. Selective Ion Recording (SIR) The ion source was operated at 200 C with an electron energy of 70 ev and a trap current of 150 ma. The corresponding selected ions for each compound, the analogous fragment formula and their associated dwell times can be seen in Table 1. Figure 2. Waters Micromass Quattro micro GC MS System. GC OVEN Compounds Steranes/ Bicadinanes/ Hopanes/ Methyl steranes SIR fragment 217 217 217 Fragment formula C 16 H 31 C 16 H 31 C 16 H 31 Dwell Time (secs) 0.1 0.1 0.1 GC INTERFACE REMOVABLE INNER SOURCE PRE-FILTER POST-FILTER HEXAPOLE COLLISION CELL Bicadinanes/ Hopanes 119 119 C 14 H 23 0.1 C 14 H 23 0.1 CONVERSION DYNODE Detector REMOVEABLE ION SOURCE PHOSPHOR ISOLATION VALVE PHOTOMULTIPLIER QUADRUPOLE QUADRUPOLE (MS1) (MS2) Figure 3. Waters Micromass Quattro micro GC schematic. Bicadinanes 369 C 30 H 54 0.1 Table 1: Compound type, their associated SIR fragment mass, fragment formula and dwell time.

Multiple Reaction Monitoring (MRM) The ion source was operated at 200 C with an electron energy of 70 ev and a trap current of 150 ma. The collision gas for the MRM transitions was argon with the gas pressure in the collision cell being held at 5e- 3 mbar. The following ion transitions, molecular formula, their associated dwell time and collision energy can all be seen in Table 2. Compounds MRM Formula Dwell Molecular Fragment Collision Time formula formula energy (secs) C27 Sterane 372.4 >217.2 C 27 H 48 C 16 H 31 0.1 10 C28 Sterane 386.4>217.2 C 28 H 50 C 16 H 31 0.1 10 Figure 4. SIR analyses of an oil formed in a marine environment. C29 Sterane 400.4 >217.2 C 29 H 52 C 16 H 31 0.1 10 C30 Sterane 414.4>217.2 C 30 H 54 C 16 H 31 0.1 10 Bicadananes 412>369 C 30 H 52 C 27 H 45 0.1 10 Table 2: Compound type, their associated MRM transitions, molecular formula, fragment formula, dwell time and collision energy Results Figures 4 and 5 show the SIR analyses of oils formed in a marine and terrigenous environment respectively showing the selected ions described in Table 1. The 85 Da channel shows the oil sample containing a high concentration of alkane compounds while the 369 Da and 191 Da channels show the presence of a number of bicadinane and hopane components. The bicadinanes are significantly more concentrated in the terrigenous sample (Figure 5, 369 Da ion) due to the fact that the compounds originate from a resin exuded from higher plants (3). The 217 Da channel shows the presence of not only C27-C30 steranes but also any bicadinane, hopanes and methyl sterane interferences. Figure 5. The SIR of an oil formed in a terrigenous environment.

Figure 6. MRM analysis of marine oils Figures 6 and 7 show the MRM analysis of the marine and terrigenous oils with the five MRM transitions described in Table 2. The presence of the four steranes (their associated isomers) are confirmed from the relevant transitions displayed. The presence of C28 steranes in figure 6 indicates an algal contribution and with the significant quantities of C30 steranes this confirms the marine environment. The presence of C29 steranes in this sample also identifies the presence of some plant life. However, the low levels of the bicadinanes confirm the environment to be non terrigenous. Figure 7 shows a higher quantity of C29 steranes compared to the C28 sterane (possibly from freshwater algae or bacteria) and indicates a terrigenous rather than a marine environment. The lack of any C30 steranes and the presence of a significant quantity of bicadinane material further confirm this. Figure 7. MRM analysis of terrigenous oils.

Conclusions Through the use of the Waters Micromass Quattro micro GC triple quadrupole mass spectrometer we have been able to specifically identify C27-C30 steranes and use the information to accurately identify the facie of the rock oil under investigation. Comparison with the SIR analyses clearly identifies the difficulties encountered when undertaking such an investigation on a single quadrupole instrument and that for rapid unambiguous routine analysis a triple quadrupole mass analyser is required. The bicadinane interferences seen in the SIR experiments are clearly identified and shown to cause no interference when the same samples are analysed by MRM. References 1. Interpreting Molecular Fossils in Petroleum and Ancient Sediments. Kenneth. E. Peters and J. Michael Moldovan 1993. Prentice-Hall Inc, New Jersey. ISBN 0-13-086752-7 2. Biomarkers for Geologists A practical Guide to the Application of Steranes and Triterpanes in Petroleum Geology. AAPG Methods in Applications Series No 9. Douglas. W. Waples and Tsutomu Machchara. 1991 The American Association of Petroleum Geologists. ISBN 0-89181-659-3 3. Peter Abohlin and Awang Awang Sapawi, Private Communication.

Sales Offices: AUSTRIA 43 1 877 18 07 AUSTRALIA 61 2 9933 1777 BELGIUM AND LUXEMBOURG 32 2 726 1000 BRAZIL 55 11 5543 7788 CANADA 800 252 4752 X2205 CZECH REPUBLIC 420 2 617 11384 DENMARK 45 46 59 8080 FINLAND 358 9 506 4140 FRANCE 33 1 3048 7200 GERMANY 49 6196 400600 HONG KONG 852 29 64 1800 HUNGARY 36 1 350 5086 INDIA 91 80 2837 1900 KOREA 82 2 820 2700 MEXICO 52 55 5524 7636 THE NETHERLANDS 31 76 508 7200 NORWAY 47 6 384 6050 PEOPLE S REPUBLIC OF CHINA 86 10 8451 8918 POLAND 48 22 833 4400 PUERTO RICO 787 747 8445 RUSSIA/CIS 7 095 931 9193 SINGAPORE 65 6278 7997 SPAIN 34 93 600 9300 SWEDEN 46 8 555 11 500 SWITZERLAND 41 62 889 2030 TAIWAN 886 2 2543 1898 IRELAND 353 1 448 1500 ITALY 39 02 27 4211 JAPAN 81 3 3471 7191 UK 44 208 238 6100 US 800 252 4752 WATERS CORPORATION 34 Maple St. Milford, MA 01757 U.S.A. T: 508 478 2000 F: 508 872 1990 www.waters.com Waters, Micromass, Micromass Quattro micro are trademarks of Waters Corporation. Trademarks are the property of their respective owners. 2004 Waters Corporation Produced in the U.S.A. September 2004 720000982EN EN&LW-PDF