Supporting Information

Similar documents
Per and Polyfluoroalkyl Substances (PFAS) in AFFF Formulations and Groundwater

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Supporting Information. Sweetened Swimming Pools and Hot Tubs

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

8 Laboratory of Environmental Pollution Control and Remediation Technology, Sun

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of Polyfluoroalkyl Substances (PFAS) in Food Products

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Supporting Information. Detection and Occurrence of Chlorinated By-products of Bisphenol A, Nonylphenol and

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

16 Malachite green 17 Leucomalachite green

HPLC-MS of the Initial Perfluorinated Surfactants and Shorter Chains:

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Direct Determination of Small Organic Acids in Sea Water by IC-MS

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Coupling Large Volume Injection for Aqueous Samples and Organic Extracts with LC-Tandem Mass Spectrometry

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

Determination of urea in ultrapure water by IC-MS/MS

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

DISCLAIMER: This method:

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

ROOT UPTAKE AND TRANSLOCATION OF PERFLUORINATED ALKYL ACIDS BY THREE HYDROPONICALLY GROWN CROPS

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Conc n of A OAs present (um) Conc n of B OAs present (um)

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

CASE STUDY 3: Quantitative and Qualitative Analysis of Perfluoroalkyl Substances (PFASs) in Wildlife Samples Using the Xevo G2-XS Q-Tof GOAL

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Acrylamide (electrophoresis grade), AR grade captopril, L-cysteine, glutathione,

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Agilent ESI and APCI sources: for polar to non-polar compounds

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

Determination of Pharmaceuticals in Environmental Samples

A biphasic oxidation of alcohols to aldehydes and ketones using a simplified packed-bed microreactor

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Figure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Determination of trace anions in concentrated hydrofluoric acid

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

QTOF Training Manual

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Application Note. Abstract. Authors. Environmental

Analysis of Polar Metabolites using Mass Spectrometry

Mechanistic Insights into Chloride Ion Detection from the Atmospheric-Pressure Afterglow of an Argon Inductively Coupled Plasma

4.1 MATERIALS 4.2 EQUIPMENTS

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Fumonisin. Fumonisin B 1 Fumonisin B 2. Fumonisin B 3. CAS No.:

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS Tatsuya Ezaki 1, Nobutake Sato 1, Jun Yonekubo 1,

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Transcription:

1 Supporting Information 2 3 Discovery and implications of C 2 and C 3 perfluoroalkyl sulfonates in aqueous film forming foams (AFFF) and groundwater 4 Krista A. Barzen-Hanson a and Jennifer A. Field b* 5 a Department of Chemistry, Oregon State University, Corvallis, OR 6 7 b Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis, OR 8 * Corresponding author 9 10 11 12 13 14 15 16 17 18 19 20 21 Chemicals. LC-MS grade methanol (> 99%) and GC grade 2,2,2-trifluoroethanol (> 99%) were purchased from Fisher Scientific (Fair Lawn, NJ). HPLC grade ethyl acetate (> 99%) and sodium chloride (> 99%) were purchased from Sigma Aldrich (Saint Louis, MO). B&J Brand reagent water (HPLC grade, > 99%) and hydrochloric acid (6N) were purchased from VWR (Radnor, PA). Reagent grade ammonium acetate was acquired from Avantor Performance Materials (Center Valley, PA). The PFS-MXA mixture of perfluoroalkyl sulfonoic acids (PFSAs) [perfluoro-1-butane sulfonate (PFBS), perfluoro-1-hexane sulfonate (PFHxS), perfluoro-1-heptane sulfonate (PFHpS), perfluoro-1-octane sulfonate (PFOS), and perfluoro-1-decane sulfonate (PFDS)] was purchased from Wellington Laboratories (Guelph, Ontario, Canada) in methanol with concentrations ranging from 1.77-1.93 µg/ml. The purity of the individual PFSAs in the PFS- MXA solution is > 98%. A mixture of mass-labeled perfluoroalkyl carboxylate and sulfonate S1

22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 internal standards (MPFAC-MXA) containing perfluoro-1-hexane[ 18 O 2 ]sulfonate ([ 18 O 2 ]- PFHxS) and perfluoro-1-[1,2,3,4-13 C 4 ]octanesulfonate ([ 13 C 4 ]-PFOS) was purchased from Wellington Laboratories in methanol at a concentration of 2 mg/l and are between 94% and 99% isotopically pure. Sample Extraction Method. Diluted sample (AFFF or groundwater) was added to a 15 ml polypropylene centrifuge tube (VWR) containing 0.97-1.0 g of sodium chloride. All samples for QTOF-MS and LC-MS/MS analyses were acidified with 10 µl of 6N HCl, but only samples for LC-MS/MS analysis were spiked with 1.05 ng of each isotopically-labeled internal standard. Samples for all analyses were extracted three times using 10% (v/v) 2,2,2- trifluoroethanol in ethyl acetate. Modified LC Method. Chromatographic separations were achieved using an Agilent (Santa Clara, CA) 4.6 x 12.5 mm x 5 µm Zorbax silica guard column connected in series to a 4.6 x 12.5 mm x 5 µm Zorbax propylamine (NH 2 ) guard column. The silica-nh 2 guard columns were connected in series to an Agilent 4.6 x 100 mm x 3.5 µm Zorbax Eclipse Plus C18 analytical column. The aqueous mobile phase composition (A) was changed to 3% methanol in HPLC-grade water. The pre-column between the LC pumps and the 6-port valve was removed from the system, and no background PFAS contamination from the LC was observed in solvent blanks. A shallow convex gradient was used to separate the analytes (Figure S1). The mobile phase composition was 3% MeOH in HPLC-grade water (A) and 10 mm ammonium acetate in HPLC-grade MeOH (B). Samples were loaded onto the guard columns for the first 3 minutes in 0% B. At 2.6 minutes, the needle, needle loop, and injector valve were bypassed to reduce gradient dwell time. The gradient was ramped to 25% B at 3.5 min and to 50% B at 4.5 min. At S2

45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 6 min, the gradient was at 65% B and increased to 90% B at 10 min. The B mobile phase increased linearly from 10 min to 15 min (100% B) and was then held at 100% B for 4 min. The columns were allowed to reequilibrate at initial conditions for 8 min prior to the next injection. The flow rate was constant at 0.5 ml/min. QTOF-MS Parameters. In scanning mode, quadrupole time-of-flight mass spectrometry (QTOF-MS; ABSciex, Framingham, MA) data was collected in 2200 cycles with a period cycle time of 1380 ms, a pulser frequency of 18.079 khz, and an accumulation time of 250.0 ms. The curtain, nebulizer (gas 1), and drying (gas 2) gases were 25 psi, 50 psi, and 40 psi, respectively. The ionspray voltage was set at 4500 V with a temperature of 500 C, a collision energy of -10 V, and a declustering potential of -80 V. The starting and ending masses were 70 and 1000, respectively, for the survey scan. For the dependent (product ion) scan, the accumulation time was 180 ms, and the collision energy was -40 V. The starting and ending masses were 40 and 1000, respectively. Data were collected simultaneously from survey and product ion scanning modes. The instrument was calibrated with the APCI Negative Calibration Solution (ABSciex) before each sample was injected. Error about the Mass Defect (CF 2 scale). The error about the mass defect (CF 2 scale) was determined using the uncertainty about the accurate mass (up to 5 ppm error). 1 From Eq 1 (main text), multiplying the error in the accurate mass by a constant did not change the magnitude of the error. Therefore, the mass (CF 2 scale) also had maximum error of 5 ppm. Similarly, in Eq 2 (main text), subtracting a constant from the mass (CF 2 scale) resulted in no change in the magnitude of the error. Thus, the mass defect (CF 2 scale) had a maximum error of 5 ppm. S3

67 68 69 Quantification by LC-MS/MS. To quantify PFEtS and PFPrS in all AFFF and groundwater samples, chromatographic separations were performed on an Agilent 1100 series HPLC (Santa Clara, CA) that was modified to inject 900 µl. The retention times of each PFSA 70 are listed in Table S2. Details of the modified Backe et al 2 method are outlined above. 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 Analytes were detected using a TQ Detector (Waters Corporation, Milford, MA) triple quadrupole mass spectrometer that was controlled with MassLynx 4.1 (Waters Corporation) and interfaced with an electrospray ionization source. The MS/MS was operated in negative mode and multiple reaction monitoring (MRM). The precursor and product ions for both PFEtS and PFPrS observed by QTOF-MS were added to the LC-MS/MS method. The precursor ion for PFEtS was m/z 199 with daughter ions of m/z 80 and 99, while the precursor ion for PFPrS was m/z 249 with daughter ions of m/z 80 and 99. Capillary and cone voltages were not optimized for PFEtS and PFPrS and were instead based on the optimization of PFBS 2 since no commercial analytical standards were available. Parameters for the remaining PFSAs were used as previously described. 2 Quantification of the PFEtS and PFPrS was performed using the analytical standard for PFBS, the internal standard [ 18 O 2 ]-PFHxS, and 1/x weighted calibration curve. Calibration standards were made in a blank extract, which consisted of reagent water taken through the extraction process. Solvent blanks consisted of 1 ml of blank extract, 500 µl of methanol, and 1.05 ng of each internal standard. Assuming equal molar response to PFBS, whole method limit 86 of detection (LOD) for PFEtS and PFPrS were estimated to be 0.80 and 2.7 ng/l. 2 Whole 87 88 89 method limit of quantification (LOQ) for PFEtS and PFPrS were estimated to be 1.0 and 3.3 ng/l, assuming equal molar response to PFBS. 2 All other PFSAs were quantified as described elsewhere. 2 S4

90 91 92 93 Sets of three quality control samples consisting of one solvent blank and two calibration standards were run every 8-10 AFFF and groundwater samples. Acceptable ranges for the quality control standards were ± 30% of the predicted values and below method LOD for the solvent blank. All solvent blanks were found to be below method LOD for all PFSAs. 94 95 S5

96 Table S1. Concentrations of PFSAs in groundwater samples from Sites A-K. 97 98 99 100 101 Site PFEtS PFPrS PFBS a PFPeS a PFHxS a PFHpS a PFOS a PFNS a PFDS a (ng/l) (ng/l) (ng/l) (ng/l) (ng/l) (ng/l) (ng/l) (ng/l) (ng/l) A 34 1300 4100 8000 260,000 5900 69,000 99 <LOD b B 530 12,000 24,000 14,000 c 170,000 c 4100 c 65,000 c <LOD 26 c C <LOD 19 85 49 740 37 1900 12 <LOD D <LOD 97 220 170 1200 18 130 <LOD <LOD E 31 2100 3100 1800 33,000 4700 550,000 3000 21 F 11 240 600 410 4800 180 7300 26 <LOD G 4000 63,000 210,000 d 220,000 d 880,000 d 23,000 380,000 d 310 9.1 H 1400 17,000 43,000 c 38,000 240,000 c 11,000 c 78,000 c <LOD <LOD c I <LOD 62 130 160 5200 130 2500 <LOD <LOD J 220 2600 5800 4000 42,000 2200 92,000 580 30 K 7500 54,000 58,000 d 70,000 d 360,000 d 23,000 210,000 d <LOD <LOD d a Whole method LOD and LOQ described in Backe et al. 2 b Concentration fell below whole method LOD. c Concentrations taken from Schultz et al. 3 d Concentrations taken from Backe et al. 2 Table S2. Retention times of PFSAs. 102 103 104 105 Retention time (min) PFEtS PFPrS PFBS PFPeS PFHxS PFHpS PFOS PFNS PFDS 8.38 9.24 9.99 10.67 11.32 11.94 12.31 12.72 13.15 S6

100 80 % MeOH (B) 60 40 20 106 0 0 5 10 15 20 25 30 time (min) 107 108 Figure S1. The HPLC gradient conditions used to separate and elute analytes. Flow rate is 0.5 ml/min. 109 110 111 112 113 114 115 116 117 118 119 120 References S1. Vanderford, B. J.; Mawhinney, D. B.; Rosario-Ortiz, F. L.; Snyder, S. A., Real-time detection and identification of aqueous chlorine transformation products using QTOF MS. Anal. Chem. 2008, 80, (11), 4193-4199. S2. Backe, W. J.; Day, T. C.; Field, J. A., Zwitterionic, Cationic, and Anionic Fluorinated Chemicals in Aqueous Film Forming Foam Formulations and Groundwater from U.S. Military Bases by Nonaqueous Large-Volume Injection HPLC-MS/MS. Environ. Sci. Technol. 2013, 47, (10), 5226-5234. S3. Schultz, M. M.; Barofsky, D. F.; Field, J. A., Quantitative Determination of Fluorotelomer Sulfonates in Groundwater by LC MS/MS. Environ. Sci. Technol. 2004, 38, (6), 1828-1835. 121 122 S7