[ Care and Use Manual ]

Similar documents
[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

ANALYSIS OF BASIC COMPOUNDS

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

HILIC Method Development in a Few Simple Steps

IN QUALITATIVE ANALYSIS,

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Quick Guide QUICK GUIDE. Activity 1: Determine the Reaction Rate in the Presence or Absence of an Enzyme

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

A Unique, New, Multipurpose Sorbent Engineered for Reversed-Phase SPE

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Solid Phase Extraction Method Development Tips and Tricks

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

2017 Source of Foreign Income Earned By Fund

Quick and Simple Cleanup for. Medicinal Chemistry. It s BIG.

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

ApplicationNOTE Abstract

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

APPLICATIONS TN Increased Capabilities for the Analysis of Hormones in Drinking and Waste Water Using Solid Phase Extraction (SPE) and LC/MS/MS

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Development for SPE. Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Advances in Sample Preparation for Accelerated Solvent Extraction

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

HPLC Determination of Antidepressants and their Metabolites in Plasma

Sample Prep Options for GC users

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Determination of trace anions in concentrated hydrofluoric acid

1.7µm Fortis C18 UHPLC Columns

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Tecan AC Extraction Plate

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

[ Care and Use Manual ]

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Gemini-NX Performance paired with Axia Technology

Cyclone Click to go to the page. Cyclone

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Appendix B: Detailed tables showing overall figures by country and measure

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

columns IonPac AS17-C Anion Exchange Column

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Thermo Scientific. Anion-Exchange Column

columns IonPac AS22 Anion-Exchange Column

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Export Destinations and Input Prices. Appendix A

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Your Reversed Phase Method

APPLICATIONS TN Peptide Purification Method Development: Application for the Purification of Bivalirudin. Introduction

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Routine MS Detection for USP Chromatographic Methods

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Simplify Sample Preparation [ SAMPLE PREPARATION SOLUTIONS ]

[ a ppl ic at ion no t e ]

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

Global Data Catalog initiative Christophe Charpentier ArcGIS Content Product Manager

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Determination of Additives in Carbonated Beverages

[ Care and Use Manual ]

EVOLUTE EXPRESS SPE Products. Load-Wash-Elute SPE Products

Shodex TM ODP2 HP series columns

columns IonPac SCS 1 Silica Cation Separator

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

protein interaction analysis bulletin 6300

EXPRESSION MORE PEPTIDES. MORE PROTEINS. MORE REPRODUCIBILITY. MORE QUANTIFICATION.

READY TO SCRAP: HOW MANY VESSELS AT DEMOLITION VALUE?

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

Mag Sepharose is available in the following formats (Instructions for use are included): μl TiO 2

CHROMABOND HLB. Introduction. Advantages of CHROMABOND HLB. Technical data

ProPac WCX-10 Columns

MiSeq System. Denature and Dilute Libraries Guide

Transcription:

Oasis HLB DISKS I. Introduction Oasis HLB is a Hydrophilic-Lipophilic-Balanced, water-wettable, reversed-phase sorbent for all your SPE needs. It is made from a specific ratio of two monomers, the hydrophilic N-vinylpyrrolidone and the lipophilic divinylbenzene. It provides superior reversed-phase capacity with a neutral polar hook for enhanced retention of polar analytes. Waters has built a family of SPE sorbents which inherit some key features of this unique substrate: stability at ph extremes and in a wide range of solvents, extraordinary retention of polar compounds, and a relative hydrophobic retention capacity 3 X higher than that of traditional silica-based SPE sorbents like C 18. Contents I. INTRODUCTION II. sample Pre-Treatment III. Solid Phase Extraction for Acidic, Neutral, and Basic Compounds using Oasis HLB iv. Oasis HLB Protocol Charts v. Troubleshooting Water-wettable Oasis sorbents exhibit excellent retention capacity for a wider polarity spectrum of analytes, even if the sorbent bed runs dry during conditioning or sample loading. This means that your SPE methods will be more rugged and robust, obviating the need for repeat preparation. The advantage of having higher retention capacity [k] is that more analytes are retained with less breakthrough improving the recovery and overall reproducibility of your SPE method. Available in a 47 mm diameter disk format and employing 30 μm particle size sorbent, Oasis HLB Disks extend your ability to perform a wide variety of complex sample separations. Oasis HLB Disks 1

II. Sample Pre-Treatment a. Solid Samples: Soil 1. Homogenize the sample with an appropriate solvent to obtain an aqueous based or an organic solvent based extract of the sample. Initial extraction conditions are chosen to maximize analyte recovery, while minimizing matrix interference. In many cases, it may be beneficial to add buffers, dispersive salts, or co-solvents to improve extraction efficiency. 2. Adjust the initial extract to optimize analyte retention onto the SPE sorbent. This can include ph adjustment, solvent adjustment, or solvent exchange through evaporation and reconstitution (refer to Sections IV and V). It may be necessary to centrifuge or filter the sample prior to loading. b. Aqueous Samples: Water, Beverages Adjust ph to maximize analyte retention on the SPE sorbent. Buffer salts and dispersive agents may be used to increase partitioning onto the SPE sorbent. Pretreatment to remove suspended matter prior to SPE treatment may include filtration or centrifugation. c. Non-Aqueous Liquid When appropriate the sample may be diluted with aqueous buffers and organic co-solvents for reversed-phased or mix-mode SPE. If sufficient dilution has occurred, the sample may be treated in a manner similar to an aqueous sample. 6. Elute: Draw through methanol (or other elution solvents), collecting eluates in a suitable device. 7. Evaporate/Reconstitute or Dilute (optional). 8. Inject: Cover collection plate and inject onto column. Note: For the Load and Elute steps, it is recommended that flow rates should not exceed 1.0 ml/min In all other steps, flow rates up to 5 ml/min are acceptable. iv. Oasis HLB Protocol Charts i. Generic Method Oasis HLB SPE Prepare sample (typically acidfy) 4a: Condition 4b: Equilibrate Water 4c: Load sample solution III. Solid Phase Extraction for Acidic, Neutral, and Basic Compounds using Oasis HLB (Note: refer to Table 1 for the recommended volume to be used in each step) 1. Place Oasis HLB cartridge or plate on the vacuum manifold. 2. Condition: Draw through methanol. 3. Equilibrate: Draw through water. 4. Load: Draw through diluted sample. 5. Wash: Draw through 5% methanol in water (v/v). (Release vacuum and discard waste fluids. Insert collection device, replace the cover, and turn on vacuum). 4d: Wash 5% methanol in water 4e: Elute Evaporate and reconstitute (optional) Avoid using methods developed for C 18 or other silica-based cartidges (see note below) Oasis HLB Disks 2

The fast Oasis HLB generic method is ideal for LC/MS/MS analysis The generic method is an excellent starting point since it wor k s for a wide range of compound s, yielding hig h recoveries (> 85%) and consistent results (< 5% RSD) When cleaner backgrounds are required for higher sensitivity or selectivity, the generic protocol can be optimized using a straighforward method development strategy. The strategy uses the full ph range (ph 1 to ph 14) and varies the organic solvent level. Note: Wash and Elute steps developed for C 18 or other silica-based sorbents may not be appropriate for the polymeric Oasis HLB sorbent. ii. Strategy for Optimizing the Generic SPE Method Prepare sample solution either in acid or base Condition Equilibrate Water The strategic procedure to obtain cleaner extracts start with the generic method through the first wash. By adjusting the ph of the additional washes to increase analyte retention, higher concentrations of organic solvent may be applied to remove interferences. The ph is decreased for acidic analytes (below the pka of the compound) to increase retention. The ph is raised for basic compounds (above the pka of the compound) to increase retention. The ph is then changed to elute the analyte. The % solvent in the Wash 2 and Elute steps is determined by varying the % methanol in 10% increments at each ph. Analyze the Wash 2 and Elute samples to determine optimum % methanol. Select the highest % methanol in Wash 2 that does not remove any analytes. Select the lowest % methanol in the Elute step that elutes the analytes. Figure 1: Retention Factor Versus ph For Acids, Bases, and Neutrals Load sample solution Wash 1 5% methanol in water Acidic Compounds Basic Compounds Wash 2 2% formic acid in methanol/water Elute 5% NH 4 OH in methanol/water Wash 2 5% NH 4 OH in methanol/water Elute 2% formic acid in methanol/water Summary With the generic SPE method, one method yields good results for a wide range of compounds. With an optimized method, cleaner extracts can be obtained. Oasis HLB Disks 3

v. Troubleshooting a. Adjustment to Optimize Recoveries Spike an appropriate volume of reagent water with all analytes and internal/surrogate standards. Follow steps 4a-4e in Section II, but use a rack to collect the eluates in the Load (4c), Wash (4d), and Elute (4e) steps in separate collection vessels. In addition, repeat step 4e with a second portion of methanol and collect the eluate. Analyze all four collected fractions. Use the provided table to determine adjustments, if necessary, to optimize sample recovery. If the fraction from this step contains the analyte: Load (4c) Wash (4d) First Elution (4e) Second Elution (4e repeated) Make this adjustment for optimum analyte recovery: The Oasis HLB sorbent has been found to retain ionized analytes more strongly than silica-based reversed-phase sorbents. However, recoveries may be enhanced when analyte ionization is suppressed. For acidic analytes, adjust the sample ph to at least two ph units below the pka of the acid. For basic analytes, adjust the ph to at least two ph units above the pka of the conjugate acid. Recoveries of very polar analytes can be increased by using only water (not 5% methanol in water) as the wash solution. If an acceptable recovery of analyte(s) is obtained in this fraction (usually > 90%), no adjustments are necessary. For very non-polar analytes, methanol may not have adequate elution strength. Stronger solvents such as acetonitrile or ethyl acetate may be substituted, or used in sequence. In addition, for ionizable analytes, methanol may need to be modified with the addition of 2% acid or 2% base, as appropriate. If solvents stronger than methanol or acetonitrile are used for the elution, then a preliminary conditioning step (see step 4a) should be performed prior to the methanol conditioning step. For example, if ethyl acetate is to be used as an eluent, condition the cartridge with ethyl acetate, followed by methanol (4a) and then water (4b). Oasis HLB Disks 4

Sales Offices: Austria and European Export (Central South Eastern Europe, CIS and Middle East) 431 877 18 07 Australia 2 9933 1777 Belgium 32 2 726 1000 Brazil 55 11 5094 3788 Canada 800 252 4752 China 8621 6495 6999 CIS/Russia +7 495 3367000 Czech Republic 42 02 617 11384 Denmark 45 46 59 8080 Finland +358 9 5659 6288 France (33) 1 30 48 72 00 Germany 49 6196 400600 Hong Kong 852 29 64 1800 Hungary 36 1 350 5086 India and India Subcontinent 91 80 2 837 1900 Ireland 353 1 448 1500 Italy 02 265 0983 Japan (81) 3 3471 7191 Korea (82) 2 820 2700 Mexico 5255 5200 1860 The Netherlands +31 (0)76-50 87 200 Norway 47 63 84 60 50 Poland (48) 22 833 4400 Puerto Rico 787 747 8445 Singapore 65 6273 1221 Spain 34 93 600 93 00 Sweden 46 8 555 11500 Switzerland 41 56 676 7000 Taiwan 886 2 2543 1898 United Kingdom 44 208 238 6100 2008 Waters Corporation. Waters, The Science of What s Possible, and Oasis are trademarks of Waters Corporation. November 2008 720002816EN Rev. A KK-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com Oasis HLB Disks 5