PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Similar documents
Precision measurements of the radio emission in air showers with LOFAR

arxiv: v1 [astro-ph.he] 11 May 2017

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Short review and prospects of radio detection of high-energy cosmic rays. Andreas Haungs

Analytic description of the radio emission of air showers based on its emission mechanisms

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

arxiv: v1 [astro-ph.he] 12 Feb 2013

The cosmic-ray energy spectrum above ev measured with the LOFAR Radboud Air Shower Array

Radio Detection of Cosmic Rays with LOFAR. Heino Falcke

An introduction to AERA. An Introduction to the Auger Engineering Radio Array (AERA)

The effect of the atmospheric refractive index on the radio signal of extensive air showers using Global Data Assimilation System (GDAS)

Contributions of the LOFAR Cosmic Ray Key Science Project to the 35th International Cosmic Ray Conference (ICRC 2017)

arxiv: v1 [astro-ph.im] 5 Nov 2018

Towards a fast and precise forward model for air shower radio simulation

The Tunka-Rex Experiment for the Detection of the Air- Shower Radio Emission

NuMoon: Status of Ultra-High-Energy Cosmic-Ray detection with LOFAR and improved limits with the WSRT

arxiv: v1 [astro-ph.im] 2 Jun 2017

What the radio signal tells about the cosmic-ray air shower

arxiv: v1 [astro-ph.he] 8 Jul 2012

What we (don t) know about UHECRs

Ultra-short Radio Pulses from High Energy Cosmic Rays

Thunderstorm electric fields probed by extensive air showers through their polarized radio emission

Geosynchrotron radio emission from CORSIKAsimulated

The KASCADE-Grande Experiment

Tunka Radio Extension: Overview and Recent Results

Neutrinos with a cosmic ray detector. Cosmic rays with a neutrino detector

Implications for the Radio Detection of Cosmic Rays

Detecting High Energy Cosmic Rays with LOFAR

On the Combined Analysis of Muon Shower Size and Depth of Shower Maximum

Parameters Sensitive to the Mass Composition of Cosmic Rays and Their Application at the Pierre Auger Observatory

Radio-detection of UHECR by the CODALEMA experiment

Measurement of the cosmic ray spectrum and chemical composition in the ev energy range

Published in: 7th International Conference on Acoustic and Radio EeV Neutrino Detection Activities

Mass Composition Study at the Pierre Auger Observatory

PoS(AASKA14)148. Precision measurements of cosmic ray air showers with the SKA

PoS(ICRC2017)326. The influence of weather effects on the reconstruction of extensive air showers at the Pierre Auger Observatory

Latest results and perspectives of the KASCADE-Grande EAS facility

From the Knee to the toes: The challenge of cosmic-ray composition

arxiv: v1 [astro-ph.he] 5 Oct 2012

Radiowave Detection of Ultra-High Energy Neutrinos and Cosmic Rays

ON THE WAY TO THE DETERMINATION OF THE COSMIC RAY MASS COMPOSITION BY THE PIERRE AUGER FLUORESCENCE DETECTOR: THE MINIMUM MOMENTUM METHOD

The Gerasimova-Zatsepin effect

Atmospheric electric fields during thunderstorm conditions measured by LOFAR Trinh, Thi Ngoc Gia

Depth of maximum of air-shower profiles at the Pierre Auger Observatory: Measurements above ev and Composition Implications

arxiv: v1 [astro-ph.he] 14 Jul 2017

Tim Huege for the LOPES collaboration

The cosmic ray energy spectrum measured using the Pierre Auger Observatory

The Pierre Auger Observatory Status - First Results - Plans

arxiv: v1 [astro-ph] 29 Jun 2008

arxiv: v1 [astro-ph.im] 9 Apr 2013

Detection of Cosmic Rays at Ultra-High Energies with Phase I of the Square Kilometre Array (SKADS) Olaf Scholten and Heino Falcke

Study of Performance Improvement for Air Shower Array with Surface Water Cherenkov Detectors

arxiv: v1 [astro-ph.he] 28 Jan 2013

THE PIERRE AUGER OBSERVATORY: STATUS AND RECENT RESULTS

arxiv: v1 [astro-ph.he] 26 Oct 2010

Senior Design Proposal

arxiv: v2 [astro-ph.im] 1 Jul 2015

UHE Cosmic Rays and Neutrinos with the Pierre Auger Observatory

Published in: 7th International Conference on Acoustic and Radio EeV Neutrino Detection Activities

Radio emission from cosmic ray air showers: Simulation results and parametrization

Ultra- high energy cosmic rays

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

arxiv: v1 [astro-ph.im] 14 Sep 2017

UC Irvine UC Irvine Previously Published Works

A CORSIKA study on the influence of muon detector thresholds on the separability of primary cosmic rays at highest energies

The Pierre Auger Observatory in 2007

A method of observing Cherenkov light at the Yakutsk EAS array

STUDY ON MASS COMPOSITION OF EXTENSIVE AIR SHOWER WITH ULTRA HIGH ENERGY COSMIC RAYS USING Q PARAMETER AND THEIR MUON COMPONENT

Longitudinal profile of Nµ/Ne in extensive air showers: Implications for cosmic rays mass composition study

Search for clustering of ultra high energy cosmic rays from the Pierre Auger Observatory

Radio-detection detection of UHECR by the CODALEMA experiment

P. Tinyakov 1 TELESCOPE ARRAY: LATEST RESULTS. P. Tinyakov. for the Telescope Array Collaboration. Telescope Array detector. Spectrum.

Status and results from the Pierre Auger Observatory

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

arxiv: v1 [astro-ph] 30 Jul 2008

Ultra-High-Energy Cosmic Rays: A Tale of Two Observatories

Correlation between the UHECRs measured by the Pierre Auger Observatory and Telescope Array and neutrino candidate events from IceCube

Search for isotropic microwave radiation from electron beam in the atmosphere

Overview and Status of the Lunar Detection of Cosmic Particles with LOFAR

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

arxiv: v1 [astro-ph.he] 8 Apr 2015

Study of high muon multiplicity cosmic-ray events with ALICE at the CERN Large Hadron Collider

arxiv: v1 [astro-ph.he] 25 Mar 2015

PoS(ICRC2015)424. YAC sensitivity for measuring the light-component spectrum of primary cosmic rays at the knee energies

Experimental Constraints to high energy hadronic interaction models using the Pierre Auger Observatory part-i

7 th International Workshop on New Worlds in Astroparticle Physics São Tomé, September 2009 THE AMIGA PROJECT

The air-shower experiment KASCADE-Grande

Search for EeV Protons of Galactic Origin

Cosmic Rays - in Poland

Studies of Ultra High Energy Cosmic Rays with the Pierre Auger Observatory

Study of Number of photons at axis Shower with different de/dx and Fluorescence Yield

arxiv: v1 [astro-ph.he] 31 Dec 2018

Numerical study of the electron lateral distribution in atmospheric showers of high energy cosmic rays

PoS(ICRC2015)349. TA Spectrum Summary

The optimum distance at which to determine the size of a giant air shower

Recent measurements of ultra-high energy cosmic rays and their impact on hadronic interaction modeling

Search for ultra-high Energy Photons with the Pierre Auger Observatory

arxiv:astro-ph/ v1 20 Sep 2004

arxiv:astro-ph/ v2 27 Apr 2002

PoS(ICRC2015)430. Shower reconstruction performance of the new Tibet hybrid experiment consisting of YAC-II, Tibet-III and MD arrays

Transcription:

PDF hosted at the Radboud Repository of the Radboud University Nijmegen The following full text is a publisher's version. For additional information about this publication click this link. http://hdl.handle.net/2066/157942 Please be advised that this information was generated on 2017-12-05 and may be subject to change.

Proc. Int. Symp. for Ultra-High Energy Cosmic Rays (UHECR2014) http://doi.org/10.7566/jpscp.9.010004 Radio detection of air showers with LOFAR and AERA Jörg R. Hörandel 1,2 on behalf of the LOFAR key science project Cosmic Rays and the Pierre Auger Collaboration 1 Radboud University Nijmegen, Department of Astrophysics, IMAPP, P.O. Box 9010, 6500 GL Nijmegen, The Netherlands, http://particle.astro.ru.nl 2 Nikhef E-mail: j.horandel@astro.ru.nl Radio detection of extensive air showers is a new method to measure the properties of high-energy cosmic rays. Recent results are reviewed from the LOFAR radio telescope and the Auger Engineering Radio Array (AERA) at the Pierre Auger Observatory. KEYWORDS: UHECR 2014, cosmic rays, air showers, radio emission, radio detection 1. Introduction To understand the origin of high-energy cosmic rays is one of the open key questions in astroparticle physics [1, 2]. An inspiring article, published in 2003 [3] heralded the renaissance of radio detection of extensive air showers with the ultimate goal to measure the properties of cosmic rays with this technique and the pioneer experiments LOPES [4] and CODALEMA [5] were initiated. The big success of these pathfinders stimulated further investigations of the radio emission of air showers on larger scales, with installations such as Tunka-Rex [6], AERA (Auger Engineering Radio Array) at the Pierre Auger Observatory, and the LOFAR radio telescope. Significant progress has been achieved in the last decade [7] and we now understand the emission processes of the radio waves in the atmosphere. Most of the emission is due to the interaction of the shower with the magnetic field of the Earth, which leads to a transverse current in the shower. In addition to this emission, the overabundance of electrons in the shower that are collected from atmospheric molecules leads to a current in the direction of the shower. 2. Radio Air-Shower Detectors Two modern radio detectors for extensive air showers are the LOFAR radio telescope (in particular, its dense core in the Netherlands) and AERA at the Pierre Auger Observatory in Argentina. The layout of the two set-ups is drawn to scale in Fig. 1. LOFAR radio telescope The LOFAR key science project Cosmic Rays represents one of the six scientific key objectives of LOFAR [8,9]. LOFAR is a digital radio telescope. Its antennas are spread over several European countries and are used together for interferometric radio observations in the frequency range of 10 240 MHz. The density of antennas increases towards the center of LOFAR, which is located in the Netherlands. Here, about 2400 antennas are clustered on an area of roughly 10 km 2. This high density of antennas makes LOFAR the perfect tool to study features of the radio emission created by extensive air showers. Air-shower measurements are conducted based on a trigger received from an array of scintillators (LORA) [10, 11], which results in a read-out of the ring buffers that store the raw voltage traces per antenna for up to 5 s. LOFAR comprises two types of antennas, recording radio emission in low-frequency band from 10 to 90 MHz and also in the high-frequency 010004-1 2016 The Physical Society of Japan

010004-2 AERA Auger Engineering Radio Array 153 antennas >2000 antennas 1 km Fig. 1. Layout of AERA at the Pierre Auger Observatory and the dense core of LOFAR drawn to scale. band (110 240 MHz). AERA at the Pierre Auger Observatory AERA is a radio extension of the Pierre Auger Observatory. The Observatory is a 3000-km 2 hybrid cosmic-ray air-shower detector in Argentina [12,13], with an array of 1660 water-čerenkov detectors and 27 fluorescence telescopes at four locations on the periphery [14]. The area near the Coihueco fluorescence detector contains a number of low-energy enhancements, including AERA. AERA is located in a region with a higher density of water-čerenkov detectors (on a 750 m grid) and within the field of view of HEAT [15], allowing for the calibration of the radio signal using super-hybrid air-shower measurements, i.e., recording simultaneously the fluorescence light, the particles at the ground, and the radio emission from extensive air showers. Since March 2015 AERA consists of 153 autonomous radio-detection stations, distributed with different spacings, ranging from 150 m in the dense core up to 750 m, covering an area of about 17 km 2. Different types of antennas are used, including logarithmic periodic dipoles and active bowtie antennas (named Butterfly antennas [16]) covering the frequency range from 30 to 80 MHz [17,18]. 3. Precision measurement of the radio emission in air showers LOFAR combines a high antenna density and a fast sampling of the measured voltage traces in each antenna. This yields very detailed information for each measured air shower and the properties of the radio emission have been measured with high precision. At the Pierre Auger Observatory air showers are measured simultaneously with various detector systems: radio detectors, fluorescence light telescopes, water-čerenkov detectors, and underground muon detectors. This unique combination yields complementary information about the showers and allows to investigate correlations between the various shower components. Some important aspects of radio emission in air showers are reviewed in the following. We focus on radio emission in the frequency range 30 80 MHz, only one result (Fig. 3 right) deals with higher frequencies.

010004-3 Fig. 2. Left: Footprint of an air shower measured with AERA at the Pierre Auger Observatory, the boxes representing the radio-detector stations. The colored background represents predictions of the radio signal according to simulations [19]. Right: The arrival time of the signals, relative to a plane as a function to the distance to the shower axis as measured with LOFAR. The lower right graph illustrates the arrival time differences with respect to a fit (hyperboloid) [20]. Lateral distribution function of the radio signals The footprint of the radio emission recorded at ground level is not rotationally symmetric [19, 21, 22], such as, e.g., the particle content of a shower, see Fig. 2 (left). Radio emission is generated through interactions with the Earth magnetic field, which yields a bean-shaped footprint on the ground. The correct reference system is in the shower plane (perpendicular to the shower axis), with one coordinate axis along the v B direction and the second axis along the v ( v B) direction. Here v is the propagation velocity vector of the shower (parallel to the shower axis) and B represents the direction and strength of the Earth magnetic field. The measured power in the frequency range 30 80 MHz is plotted as a function of the distance to the shower axis in Fig. 3 (left). For example at a distance of 200 m from the shower axis, ambiguities are visible in this one-dimensional projection: the recorded signal strength is a function of the azimuth angle, which results in the visible structure. Historically, the lateral distribution of the radio signal on the ground has often been parameterized with a simple exponential function (e.g., [23]). However, the LOFAR measurements suggest that the radio emission should be parameterized by a more complex expression: a two-dimensional Gaussian function is used to describe the approximately exponential fall-off at large distances from the shower axis. A second (smaller) two-dimensional Gaussian function is subtracted from the first one to describe the ring structure of the signal close to the shower axis. To reproduce the observed bean shape, the centers of both Gaussian functions are slightly offset. The power at position (x, y ) in the shower plane (perpendicular to the shower axis) is described as P(x, y ) = A + exp ( (x X + ) 2 + (y Y + ) 2 ) A exp ( (x X ) 2 + (y Y ) 2 ), (1) σ 2 + Where the parameters are the scaling factors A + and A (where in general A + >> A ), the width of the Gaussian functions σ + and σ, and the centers of the two-dimensional Gaussian distributions (X +, Y + ) and (X, Y ), respectively. First quantitative measurements in the frequency range 120-240 MHz Radio emission from extensive air showers has also been recorded with the LOFAR high-band antennas in the 200 MHz frequency domain [24]. The measured power is depicted in Fig. 3 (right) as a function of the distance to the shower axis. A clear maximum is visible at distances around 120 m in this one-dimensional projection, indicating a clear (Čerenkov) ring structure. Such rings are predicted from theory: rela- σ 2

010004-4 Fig. 3. Total power measured in an air shower as a function of the distance to the shower axis (in the shower plane) as measured by LOFAR in the frequency range 30 80 MHz (left) [22] and 110 190 MHz (right) [24]. tivistic time compression effects lead to a ring of amplified emission, which starts to dominate the emission pattern for frequencies above 100 MHz. The LOFAR data clearly confirm the importance to include the index of refraction of air as a function of height into calculations of the radio emission. Shape of the shower front The precise shape of the radio wavefront is a long-standing issue. In the literature different scenarios have been discussed: a spherical, conical, or hyperbolic shape (e.g. [25]). The LOFAR findings clearly indicate that a hyperboloid is the best way to describe the shape of the measured wavefront [20]. A hyperboloid asymptotically reaches a conical shape at large distances from the shower axis and can be approximated as a sphere close to the shower axis. A measured wavefront of a shower registered with LOFAR is shown in Fig. 2 (right). The time difference relative to a plane is plotted as a function of distance to the shower axis. The line indicates a fit of a hyperboloid to the measured data. The lower part of the graph shows the time differences of the individual antennas with respect to the fit function. Polarization of the radio signal The radio emission in extensive air showers originates from different processes. The dominant mechanism is of geomagnetic origin [4, 26]. Electrons and positrons in the shower are accelerated in opposite directions by the Lorentz force exerted by the magnetic field of the Earth. The generated radio emission is linearly polarized in the direction of the Lorentz force ( v B), where v is the propagation velocity vector of the shower (parallel to the shower axis) and B represents the direction and strength of the Earth magnetic field. A secondary contribution to the radio emission results from the excess of electrons at the front of the shower (Askaryan effect) [27, 28]. This excess is built up from electrons that are knocked out of atmospheric molecules by interactions with shower particles and by a net depletion of positrons due to annihilation. This charge excess contribution is radially polarized, pointing towards the shower axis. The resulting emission measured at the ground is the sum of both components. Interference between these components may be constructive or destructive, depending on the position of the observer/antenna relative to the shower. The emission is strongly beamed in the forward direction due to the relativistic velocities of the particles. Additionally, the emission propagates through the atmosphere, which has a non-unity index of refraction that changes with height. This gives rise to relativistic time-compression effects, most prominently resulting in a ring of amplified emission around the Čerenkov angle, see Fig. 3. By precisely measuring the polarization direction of the electric field at each antenna position, the ratio a between the contributions from the Askaryan effect and the geomagnetic emission is measured. The resulting ratios as measured at the Auger Observatory for individual air showers are shown in Fig. 4 (left) [29]. An average value of a = 14% ± 2% is obtained. At LOFAR the ratio a has been measured as a function of the distance to the shower axis for showers with different zenith angles, as depicted

010004-5 60 40 measurement nr. 20 0-1 -0.5 0 0.5 1 a Fig. 4. Radio emission processes in the atmosphere. The ratio a between contributions due to the Askaryan effect and the geomagnetic emission is plotted as measured at the Auger Observatory for different air showers (left) [29] and as a function of the distance to the shower axis (in the shower plane) for showers with different zenith angles as measured by LOFAR (right) [30]. in Fig. 4 (right) [30]. The figure illustrates that the contribution through the Askaryan effect increases with increasing distance to the shower axis and it is more pronounced for vertical showers (with small zenith angle). Confirmation of simulation codes The detailed investigations of the properties of the radio emission and the comparison between measurements and predictions from simulations demonstrate that the simulation code CoREAS [31] fully describes all relevant features of the radio emission in air showers and the predictions can be used to interpret the measured air-shower data. Probing atmospheric electric fields during thunderstorms Radio detection of air showers can also be used for auxiliary science, such as the measurements of electric fields in the atmosphere during thunderstorms [32 34]. The footprint of the radio emission from an air shower, which developed during a thunderstorm is shown in Fig. 6 (right) [34]. The intensity and polarization patterns of such air showers are radically different from those measured during fair-weather conditions. The figure illustrates the polarization as measured with individual LOFAR antennas (arrows) in the shower plane. An arrow labeled normal indicates the expected polarization direction for fair-weather conditions. LOFAR antennas are grouped into circular stations, of which seven are depicted. The position of the shower axis, orthogonal to the shower plane, is indicated by the intersection of the dashed lines. With the use of a simple two-layer model for the atmospheric electric field, these patterns can be well reproduced by state-of-the-art simulation codes. This in turn provides a novel way to study atmospheric electric fields. 4. Measuring properties of cosmic rays with the radio technique The ultimate objective is to fully characterize the incoming cosmic ray with the radio measurements, i.e., to determine its arrival direction, its energy, and the particle type/mass (see, e.g., [35]).

010004-6 [m] 400 + 350 300 250 200 150 100 50 0 300 400 500 600 700 800 900 1000 1100 Distance to X max [g/cm Fig. 5. Determining the properties of cosmic rays with radio measurements [22]. Left: Energy of the cosmic ray (determined from simulations and measured with the LORA air shower array) as a function of the integrated measured radio power. Right: Width of the footprint of the radio emission as a function of the distance to the shower maximum. 2 ] Arrival direction A precise description of the shape of the shower front is essential to correctly reconstruct the direction of the incoming cosmic ray. Different shapes have been investigated at LO- FAR as discussed above [20]. Reconstructing the arrival directions of the same measured showers with different wavefront shapes results in differences in the reconstructed arrival directions of typically less than 1 between a plane and a hyperboloid and typically less than 0.1 between a cone and a hyperboloid. Based on these investigations it is expected that the angular resolution for the arrival direction of the shower is better than 1. Corresponding analyses at the Auger Observatory are under way, expecting a similar precision. Energy The parameters of the function to model the intensity pattern of the radiation on the ground (as described above) are sensitive to the properties of the shower-inducing cosmic rays [22]. The integral of the measured power density is proportional to the shower energy. This is illustrated in Fig. 5 (left). The shower energy is plotted as a function of a parameter, that is proportional to the integrated power. The measured signal strength is corrected for a factor, which depends on the angle between the shower axis and the direction of the geomagnetic field. This is necessary, since the dominant geomagnetic emission strongly depends on this angle. The shower energy is determined in two ways in the figure: it is derived from Monte Carlo simulations (using CORSIKA [36] and CoREAS) and it has been measured with the particle detector array at LOFAR (LORA). A clear correlation can be seen between the shower energy and the measured radio intensity on the ground. A very sophisticated analysis is ongoing at the Auger Observatory [37 39]. The energy content of the radio emission in air showers in the frequency range 30 80 MHz has been measured on an absolute scale. A 1 EeV air shower, arriving perpendicularly to the geomagnetic field radiates 15.8 MeV in the radio frequency regime. Since radio emission is not suffering from attenuation in the atmosphere and the radiation strength can be calculated from first principles, measuring the radio emission seems to be a very promising tool to establish the absolute energy scale of air-shower detectors. Depth of the shower maximum Several methods are studied at LOFAR and the Auger Observatory to derive the type of the incoming cosmic ray or its atomic mass A from the radio measurements. The key is to measure the depth of the shower maximum in the atmosphere, which is proportional to ln A. The width of the measured footprint is proportional to the geometrical distance from the antennas to the position of the shower maximum. This correlation is shown in Fig. 5 (right). This method is used at LOFAR and at the Auger Observatory to estimate the cosmic-ray mass [19, 22]. To obtain a precise value of the depth of the shower maximum for each shower, we apply the

010004-7 Fig. 6. Left: Determining the depth of the shower maximum from the radio measurements. The χ 2 values of simulated showers are shown as a function of the depth of the shower maximum [40]. Right: Footprint of the radio emission of an air shower, which developed during a thunderstorm [34]. following procedure, originally developed at LOFAR and now also applied at the Auger Observatory [19, 40]. The shower direction and energy are obtained from the measured signals in the particle detectors and the radio antennas. With these parameters simulations are initiated, simulating the development of air showers and the accompanying radio emission, using the CORSIKA and the CoREAS codes, for primary protons and iron nuclei. Due to fluctuations in the individual particle interactions in an air shower this results in cascades with a wide distribution for the depth of the shower maximum (all of them having the same energy and direction of incidence as the measured one). The predicted signals in the particle detectors and the radio antennas are then compared to the measurements. A χ 2 method is used to determine the simulated shower which best matches the measured values. This yields a value for the depth of the shower maximum. The method is illustrated in Fig. 6 (left). The χ 2 values are depicted as a function of the depth of the shower maximum X max.a parabola is fitted to the χ 2 values and the minimum of this function gives the estimated X max value for the measured shower. With this method X max is determined with an accuracy of 17 g/cm 2 at LOFAR. At the Auger Observatory this method is used to compare the depth of the shower maximum as obtained from the radio measurements with the X max values measured with the fluorescence detectors. Quantitative analyses of the achieved accuracy are under way. At the Auger Observatory other mass-sensitive observables are also investigated: the shape of the shower front is sensitive to the geometrical distance to the shower maximum; the shape of the shower front is approximated with a hyperboloid and the angle between the shower plane and the hyperboloid (at large distances from the shower axis) is sensitive to X max. The spectral shape of the measured radio signal is also sensitive to X max [41]. This could be a very promising method for a sparse radio array, where the only measurable radio signals are detected in a small number of radio detectors. References [1] J. Blümer, R. Engel, J. Hörandel, Prog. Part. Nucl. Phys. 63 (2009) 293. [2] M. Nagano, A. Watson, Rev. Mod. Phys. 72 (2000) 689. [3] H. Falcke, P. Gorham, Astropart. Phys. 19 (2003) 477. [4] H. Falcke, et al., Nature 435 (2005) 313.

010004-8 [5] D. Ardouin, et al., Nucl. Instr. Meth. A 555 (2005) 148. [6] D. Kostunin, et al., Nucl. Instrum. Meth. A 742 (2014) 89. [7] T. Huege, Braz. J. Phys. 44 (2014) 520. [8] M. van Haarlem, et al., Astron. Astrophys. 556 (2013) A2. [9] P. Schellart, et al., Astron. Astrophys. 560 (2013) A98. [10] S. Thoudam, et al., Nucl. Instrum. Meth. A767 (2014) 339. [11] S. Thoudam, et al., Astropart. Phys. 73 (2015) 34 [12] J. Abraham, et al., Nucl. Instr. Meth. A 523 (2004) 50. [13] J. Abraham, et al., Nucl. Instrum. Meth. A 620 (2010) 227. [14] A. Aab, et al., Nucl. Instr. Meth. A 798 (2015) 172. [15] C. Meurer, N. Scharf, Astrophys. Space Sci. Trans. 7 (2011) 183. [16] D. Charrier, Nucl. Instrum. Meth. A 662 (2012) S142. [17] P. Abreu, et al., JINST 7 (2012) P10011. [18] P. Abreu, et al., Nucl. Instrum. Meth. A 635 (2011) 92. [19] J. Schulz, et al., Proceedings 34th International Cosmic Ray Conference, Den Haag (2015), Proceedings of Science (ICRC2015) 615. [20] A. Corstanje, et al., Astropart. Phys. 61 (2015) 22. [21] A. Nelles, et al., Astropart. Phys. 60 (2015) 13. [22] A. Nelles, et al., JCAP 1505 (05) (2015) 018. [23] H. Allan, Progress in Elementary Particles and Cosmic Ray Physics, J.G. Wilson and S.G. Wouthuysen eds., North Holland, 1971, p. 169. [24] A. Nelles, et al., Astropart. Phys. 65 (2014) 11. [25] W. Apel, et al., JCAP 1409 (09) (2014) 025. [26] D. Ardouin, et al., Astropart. Phys. 31 (2009) 192. [27] V. Marin, Proceedings, 32nd International Cosmic Ray Conference, Beijing, 1 (2011) 291. [28] A. Bellétoile, et al., Astropart. Phys. 69 (2015) 50. [29] A. Aab, et al., Phys. Rev. D 89 (5) (2014) 052002. [30] P. Schellart, et al., JCAP 1410 (10) (2014) 014. [31] T. Huege, M. Ludwig, C. W. James, ARENA 2012, AIP Conf. Proc. 1535 (2013) 128. [32] S. Buitink, et al., Astron. Astroph. 467 (2007) 385. [33] W. Apel, et al., Adv. Space Res. 48 (2011) 1295. [34] P. Schellart, et al., Phys. Rev. Lett. 114 (16) (2015) 165001. [35] W. D. Apel, et al., Phys. Rev. D 90 (6) (2014) 062001. [36] D. Heck, et al., Report FZKA 6019, Forschungszentrum Karlsruhe (1998). [37] C. Glaser, et al., AIP Conf. Proc. 1535 (2013) 68. [38] C. Glaser, et al., Proceedings 34th International Cosmic Ray Conference, Den Haag (2015), Proceedings of Science (ICRC2015) 364. [39] A. Aab, et al., Submitted to: Phys. Rev. D (arxiv 1508.04267). [40] S. Buitink, et al., Phys. Rev. D 90 (8) (2014) 082003. [41] S. Grebe, et al., AIP Conf. Proc., 5th Int. ARENA Workshop 2012 1535 (2013) 73.