Zener Diodes PRIMARY CHARACTERISTICS PARAMETER VALUE UNIT V Z range nom.. to V Test current I ZT. to 8 ma V Z specification Pulse current Int. construction Single FEATURES Silicon planar power Zener diodes For use in stabilizing and clipping circuits with high power rating The Zener voltages are graded according to the international E standard. Replace suffix C with B for ± % tolerance AEC-Q qualified Material categorization: for definitions of compliance please see /doc?999 APPLICATIONS Voltage stabilization ORDERING INFORMATION DEVICE NAME ORDERING CODE TAPED UNITS PER REEL MINIMUM ORDER QUANTITY BZX8-series BZX8-series-TR ( mm tape on " reel) /box BZX8-series BZX8-series-TAP per ammopack ( mm tape) /box PACKAGE PACKAGE NAME WEIGHT MOLDING COMPOUND FLAMMABILITY RATING DO- mg UL 9 V- MOISTURE SENSITIVITY LEVEL MSL level (according J-STD-) SOLDERING CONDITIONS 6 C/ s at terminals ABSOLUTE MAXIMUM RATINGS (T amb = C, unless otherwise specified) PARAMETER TEST CONDITION SYMBOL VALUE UNIT Power dissipation Zener current Valid provided that leads at a distance of mm from case are kept at ambient temperature See Table Electrical characteristics P tot mw Junction to ambient air Valid provided that leads at a distance of mm from case are kept at ambient temperature R thja K/W Junction temperature T j C Storage temperature range T stg - to + C Rev.., -Jun- Document Number: 86 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9
ELECTRICAL CHARACTERISTICS (T amb = C, unless otherwise specified) PART NUMBER Notes () Measured with pulses t p = ms () Valid provided that leads are kept at ambient temperature at a distance of mm from case () Measured with f = khz ZENER VOLTAGE RANGE () TEST REVERSE LAEKAGE DYNAMIC RESISTANCE () TEMPERATURE COEFFICIENT OF ZENER VOLTAGE ADMISSIBLE ZENER () V Z at I ZT I ZT I ZT I R at V R Z Z at I ZT Z ZK at I ZT VZ at I ZT I Z V ma μa V %/ C ma MIN. NOM. MAX. MAX. MAX. MIN. MAX. BZX8CV...9 8 < < < -.8 -. 6 BZX8CV.8.. 8 < < < -.8 -. BZX8CV... 8 < < < -.8 -. BZX8CV6..6.8 6 < < < -.8 -. 9 BZX8CV9..9. 6 < < < -. -. 8 BZX8CV..6 < < < -.. BZX8CV.. < < < 6 -.. BZX8CV.8.. <. < < -.. BZX8CV6..6 6 < < <. 9 BZX8C6V.8 6. 6.6 < < <.. BZX8C6V8 6. 6.8. < <. <..6 BZX8CV..9. <. < <..6 BZX8C8V. 8. 8.. < 6. < <.. BZX8C9V 8. 9. 9.6. < 6.8 < <.. BZX8C 9..6. <.. < <..8 BZX8C..6. <. 8. < 8 <..8 9 BZX8C... <. 9. < 9 <..8 88 BZX8C... <. < <..8 9 BZX8C.8.6. <. < <..9 BZX8C6. 6.. <. < <..9 66 BZX8C8 6.8 8 9.. <. < <.6.9 6 BZX8C 8.8.. <. < < 6.6.9 6 BZX8C.8.. <. 6 < < 6.6.9 BZX8C.8.6. <. 8 < < 6.6.9 BZX8C. 8.9 8. <. < <.6.9 BZX8C 8 8. <. < <.6.9 6 BZX8C 8. <. < <.6.9 BZX8C6 6 8 8. <. < <.6.9 BZX8C9 9 6. <. < <.6.9 8 BZX8C 6 6. <. < <.6.9 6 BZX8C. <. 6 < 9 <.6.9 BZX8C 8. <. 9 < <.6.9 BZX8C6 6 6. <. < <.6.9 9 BZX8C6 8 6 66. <. < <.6.9 6 BZX8C68 6 68. <. < <..9 BZX8C 8. <. 6 < <..9 BZX8C8 8 8.. <. 6 < <..9 BZX8C9 8 9 96.. <. 68 < <..9 BZX8C 96 6.. <. < <..9 9. Rev.., -Jun- Document Number: 86 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9
ELECTRICAL CHARACTERISTICS (T amb = C, unless otherwise specified) PART NUMBER Notes () Measured with pulses t p = ms () Valid provided that leads are kept at ambient temperature at a distance of mm from case () Measured with f = khz ZENER VOLTAGE RANGE () TEST REVERSE LAEKAGE DYNAMIC RESISTANCE () TEMPERATURE COEFFICIENT OF ZENER VOLTAGE ADMISSIBLE ZENER () V Z at I ZT I ZT I ZT I R at V R Z Z at I ZT Z ZK at I ZT VZ at I ZT I Z V ma μa V %/ C ma MIN. NOM. MAX. MAX. MAX. MIN. MAX. BZX8BV.6..6 8 < < < -.8 -. 6 BZX8BV.9.6 8 < < < -.8 -. BZX8BV...6 8 < < < -.8 -. BZX8BV6..6.6 6 < < < -.8 -. 9 BZX8BV9.8.9.98 6 < < < -. -. 8 BZX8BV...9 < < < -.. BZX8BV.6..9 < < < 6 -.. BZX8BV.. <. < < -.. BZX8BV6.9.6. < < <. 9 BZX8B6V 6.8 6. 6. < < <.. BZX8B6V8 6.66 6.8 6.9 < <. <..6 BZX8BV...6. <. < <..6 BZX8B8V 8. 8. 8.6. < 6. < <.. BZX8B9V 8.9 9. 9.8. < 6.8 < <.. BZX8B 9.8.. <.. < <..8 BZX8B.8.. <. 8. < 8 <..8 9 BZX8B.8.. <. 9. < 9 <..8 88 BZX8B... <. < <..8 9 BZX8B... <. < <..9 BZX8B6. 6 6.. <. < <..9 66 BZX8B8.6 8 8.. <. < <.6.9 6 BZX8B 9.6.. <. < < 6.6.9 6 BZX8B.6.. <. 6 < < 6.6.9 BZX8B... <. 8 < < 6.6.9 BZX8B 6.. 8. <. < <.6.9 BZX8B 9..6 8. <. < <.6.9 6 BZX8B.. 8. <. < <.6.9 BZX8B6. 6 6. 8. <. < <.6.9 BZX8B9 8. 9 9.8 6. <. < <.6.9 8 BZX8B..9 6. <. < <.6.9 6 BZX8B 6..9. <. 6 < 9 <.6.9 BZX8B. <. 9 < <.6.9 BZX8B6.9 6.. <. < <.6.9 9 BZX8B6 6.8 6 6.. <. < <.6.9 6 BZX8B68 66.6 68 69.. <. < <..9 BZX8B. 6.. <. 6 < <..9 BZX8B8 8. 8 8.6.. <. 6 < <..9 BZX8B9 89. 9 9.8.. <. 68 < <..9 BZX8B 98.. <. < <..9 9. Rev.., -Jun- Document Number: 86 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9
BASIC CHARACTERISTICS (T amb = C, unless otherwise specified) r tha C/W.... t P t v = P. T P I T. - - - - - s t P 88 Fig. - Pulse Thermal Resistance vs. Pulse Duration R tha C/W max. typ. mm lead length 86 Fig. - Thermal Resistance vs. Lead Length r zj Ω P tot W 6. ma I Z 89 C T amb 86 Fig. - Dynamic Resistance vs. Zener Current Fig. - Admissible Power Dissipation vs. Ambient Temperature r zj Ω 6 8 ma r zj Ω V 8 V 6V V ma I Z 86 I Z 86 Fig. - Dynamic Resistance vs. Zener Current Fig. 6 - Dynamic Resistance vs. Zener Current Rev.., -Jun- Document Number: 86 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9
ma V9 V T j = C I Z 6 V6 6V8 8V 8 6 8 9 V Fig. - Breakdown Characteristics V 86 Z ma 6 8 T j = C I Z 9 V V 8 Z Fig. 8 - Breakdown Characteristics PACKAGE DIMENSIONS in millimeters (inches): DO- Cathode identification.86 (.) max. 6 (.) min.. (.6) max. 6 (.) min..6 (.) max. 9 968 Rev.., -Jun- Document Number: 86 ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT /doc?9
Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, Vishay ), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer s technical experts. Product specifications do not expand or otherwise modify Vishay s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive /6/EU of The European Parliament and of the Council of June 8, on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive /9/EC. We confirm that all the products identified as being compliant to Directive /9/EC conform to Directive /6/EU. Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as Halogen-Free follow Halogen-Free requirements as per JEDEC JS9A standards. Please note that some Vishay documentation may still make reference to the IEC 69-- definition. We confirm that all the products identified as being compliant to IEC 69-- conform to JEDEC JS9A standards. Revision: -Oct- Document Number: 9