Liquid Chromatograph Mass Spectrometer C146-E188
Ultra-High Sensitivity By incorporating newly improved ion optics and collision cell technology, the provides higher multiple reaction monitoring (MRM) sensitivity. A five-fold increase in sensitivity (reserpine, S/N ratio) has been achieved by improving ion focusing and minimizing ion losses between multi-pole lenses. These improvements also yield higher sensitivity for scan mode measurements. This higher sensitivity expands the potential range of LC/MS/MS applications. Ultra-High Speed The was designed to provide significantly higher sensitivity while maintaining the high speed offered by the LCMS-83. Ultrafast MRM transition speeds, up to 555 MRMs per second, are achieved by Shimadzu s UFsweeper collision cell technology, proprietary high-precision quadrupole machining capabilities, and unique high voltage power supply technology. In addition, the features the world s fastest* polarity switching at 15 msec. With this high-speed performance, the can dramatically improve analytical throughput. Ultra-High Reliability MRM optimization in Shimadzu s LCMS systems is based on a rapid series of automated flow injection analyses, requiring only minutes to perform. Multiple compounds can be optimized in an unattended sequence, freeing the analyst from tedious work. MRM parameters optimized for the LCMS-83 can be transferred to the, making it possible to transfer methods between systems. The offers the same ease of maintenance benefits as the LCMS-83, and all consumables, such as desolvation lines (DL) and ESI capillaries, are interchangeable as well. * Per survey result as of May 212 GCMS-QP21 Ultra GCMS-QP21 SE GCMS-TQ83 LCMS-83 LCMS-88 LCMS-22 LCMS-IT-TOF
Ultra-High Sensitivity with UFMS Technology Higher Sensitivity with Improved Ion Optics UF-Lens TM The UF-Lens is a lens system that offers both higher sensitivity and easier maintenance. The optical system integrates two multi-pole RF ion guides for higher sensitivity. In addition, the lens system can be removed without tools for easy cleaning. Sprayer UF-Lens Qarray Multi Pole 1 Q1 Pre-rod Q1 Post-rod Q3 Pre-rod Q1 Q3 Atmospheric Pressure Desolvation Line Skimmer Multi Pole 2 UFsweeper Detector Collision Cell 1 st Vacuum Chamber 2 nd 3 rd 4 th RP Triple Inlets Tmp 4 Stage Differential Pumping System Ion losses between segments are minimized by utilizing quadrupole ion guides. Previous Configuration UF-Lens TM LCMS-83 A comparison of auto-tune Q1 scan results for a standard sample (a mixture of PEG, PPG, and raffinose) obtained from the LCMS-83 and is shown to the right. Target ions used for ESI+ auto-tuning are plotted (m/z 65.5, 168.1, 256.15, 344.2, 652.4, 14.6, and 1224.75). A significant sensitivity increase across a broad molecular weight range for precursor ion transmission is demonstrated. Increase in Sensitivity (83 vs. 84) 5 4 3 2 1 5 1 m/z 15 2 4 Speed Beyond Comparison Enhanced Sensitivity
Higher CID Efficiency with Improved Collision Cell UFsweeper TM The UFsweeper II is a high-sensitivity, high-speed collision cell that features improved ion focusing by using high-speed ion transport technology. This yields better product ion transmission in the collision cell, maintaining signal intensity and suppressing crosstalk, even for high-speed or simultaneous multi-component analysis. The capability for high-throughput analysis is thus maintained at lower levels of detection. Sample Name Precursor m/z Product m/z LCMS-83 CID efficiency CID efficiency Proportional Increase Lidocaine 235.4 86.1 2. 29. 1.4 Atropine 29.1 124.1 7.2 11. Yohimbine 355.1 144. 9.5 15.6 1.6 Tetracaine 265.1 176.1 15.7 32. 2. Doxepin 28.1 17.1 4.4 7.2 1.6 Imipramine 281.1 86.1 16.2 22.1 1.3 Nortriptyline 264.1 233.1 3.8 7.4 1.9 Isopropylantipyrine 231.1 188.9 2.9 1.9 Diazepam 285. 154. 2.4 3.9 1.6 Reserpine 69.3 195.1 3.9 6.6 1.7 The offers higher sensitivity while maintaining the ultrafast performance of the LCMS-83. The figures below show simultaneous analysis of 167 pesticides in MRM positive/negative ion analysis mode. Even though positive and negative ions were LCMS-83 1. ( 1,,) measured simultaneously, both the LCMS-83 and accurately identified all 167 components. In addition, the showed improved sensitivity an average of three times higher for all components. 1. ( 1,,).75.75.5.5.25.25. 5. 1. 15. 2. min. 5. 1. 15. 2. min HPLC Analysis Column Mobile Phase A Mobile Phase B Gradient Program Flow Rate Column Temperature Shim-pack FC-ODS (2. mmi.d. 15 mml., 3µm) 5 mmol/l ammonium acetate - Water 5 mmol/l ammonium acetate - Methanol 15 %B ( min) 4 %B (1 3.5 min) 5 %B (6 min) 55 %B (8 min) 95 %B (17.5 3 min) 15 %B (3.1 4 min).2 ml/min 4 C MS Probe Voltage Nebulizing Gas Flow Drying Gas Flow DL Temperature Heat Block Temperature +4.5 kv (ESI-Positive mode) / 3.5 kv (ESI-Negative mode) L/min 1 L/min 25 C 4 C Liquid Chromatograph Mass Spectrometer 5
Proven Ultra-High Performance now with Enhanced Sensitivity Higher Sensitivity for Q1 Full Scan Spectra The maintains the same high-speed scanning (UFscanning) and polarity switching technology (UFswitching) utilized in the LCMS-83. The not only maintains Shimadzu's proprietary high-speed technologies (UF Technologies, Patent pending), which minimize sensitivity losses even at faster scan speeds, it also features improved ion optics, which provide higher sensitivity for MRMs and full scans. A comparison of Q1 full scan spectra for pesticide samples (Methomyl, Carbaryl(NAC), Phoxim, Benfuracarb, and Abamectin B1a) is shown below. The upper spectra were acquired using the and the lower spectra were acquired using the LCMS-83. As shown, the offers significant sensitivity improvements for precursor ions or full scan data. Inten.( 1,,) 2. 4 2 3 1. 3 Inten.( 1,,) 2. 2 3 1. 3 3 Inten.( 1,,) 2. 2 3 3 1. 3.5 5.5 5.5 5 2 3 4 5 6 m/z 15 u/sec LCMS-83 Inten.( 1,,) 2. 2 3 4 5 6 m/z 1 u/sec Inten.( 1,,) 2. 2 3 4 5 6 m/z 5 u/sec Inten.( 1,,) 2. 1. 1. 1..5.5.5 2 3 4 5 6 m/z 15 u/sec 2 3 4 5 6 m/z 1 u/sec 2 3 4 5 6 m/z 5 u/sec 1..5 Higher Sensitivity for MS/MS Acquisition Modes The increased scan sensitivity of the also applies to scan modes specific to triple quadrupole mass spectrometers, such as product ion scanning, precursor ion scanning, and neutral loss scanning. Historically, mass spectrometers have introduced mass deviation in linked scans, such as precursor ion scans or neutral loss scans, when measured at maximum scan speeds. Inten.( 1 5 ) 5. 2.5 Inten.( 1 7 ). 24. 2727 u/sec Precursor ion of m/z 149 251.25 25. m/z Inten.( 1 5 ) 7.5 251.25 5. 2.5. 24. 25. m/z Inten.( 1 7 ) 2. 1..5 6 u/sec Dipropyl phthalate CH 3 m/z 149 84 CH 3 83 3. 4. 5. min 3. 4. 5. min Precursor Ion Scan of Standard Mixture Sample of 8 Phthalate Esters Mass error associated with a rise in scan speed Increase in Scan Speed 3. 3.5 31. 298. 299. 3. 31. 32. 33. m/z Typical triple quadrupole mass spectrometer However, Shimadzu's proprietary UFscanning technology allows performing precursor ion scans or neutral loss scans at high speeds without loss of mass accuracy. In addition, the offers higher sensitivity levels. Precursor scan results for eight kinds of phthalate esters are shown to the left. Scans were performed at two speeds, 2727 u/sec and 6 u/sec. No mass shift is observed at either scan speed, and a significant sensitivity improvement is observed for the. 6 Speed Beyond Comparison Enhanced Sensitivity
Proven Interface for Robust Performance Robust, User-Friendly Interface The LCMS-83 and use the same interface. In LCMS analysis, it is necessary to adjust interface conditions such as temperatures and gas flow rates for optimal desolvation. Spray needle adjustment and probe position are also factors to be evaluated. In both the LCMS-83 and, temperatures and flows are easily controlled through the software. ESI probe position is set by a single easily accessible knob, and spray needle protrusion is adjusted without the need for any special tools or disassembly of the probe. In addition, this capillary incorporates a tapered design, which reduces sample clogging. Signal-to-noise test results are shown right. Sensitivity specifications (S/N > 1 Central position Locking screw Position adjustment knob 2mm +3mm Attach/detach with a single flip of a lever Integrated ESI Capillary for the and S/N > 2 for the LCMS-83) were satisfactorily obtained at each of four probe positions (from 1mm to +2mm), demonstrating the interface s robustness. ( 1,) 6. 5. 4. 1 3. 2. 1.. 5.25 5.5 min S/N: 172 LCMS-83 ( 1,) 6. 5. 4. 1 3. 2. 1.. 4. 4.25 min S/N: 191 ( 1,) 6. 5. 4. 3. 2. 1.. 5.3 5.4 5.5 min S/N: 148 ( 1,) 6. 5. 4. 3. 2. 1.. 7.25 7.5 min S/N: 895 ( 1,) 6. 5. 4. +1 3. 2. 1.. 3.25 3.5 min S/N: 147 ( 1,) 6. 5. 4. +1 3. 2. 1.. 4. 4.25 min S/N: 286 ( 1,) 6. 5. 4. +2 3. 2. 1.. 3.2 3.3 3.4 min S/N: 217 ( 1,) 6. 5. 4. +2 3. 2. 1.. 4.5 5. min S/N: 1315 S/N test data for 1 pg reserpine FIA (upper: and lower: LCMS-83) measured using fixed parameters (ESI+, 69.3 > 195., CE: -37, dwell: 197 msec, and pause: 3 msec) after auto-tuning. Easy Method Transfer MRM parameters for the LCMS-83 can be used in systems. Optimization of MRM parameters is an early step in LCMS method development. Shimadzu has streamlined the MRM optimization process with a rapid and simplified approach based on automated flow injection analysis. Several method packages, which contain chromatographic and optimized MRM conditions for a variety of analytes, including residual pesticides, veterinary drugs, and forensic drugs of abuse, have also been released. Laboratories employing LCMS-83 MRM conditions will be able to transfer these MRMs directly to the. To demonstrate this, a method for the simultaneous analysis of 167 pesticides was transferred without modification from the LCMS-83 to the. Increased sensitivity was obtained for all compounds; three example chromatograms are shown below. 1 ppb: Cloquintocet-mexyl(9.5X) 1 ppb: Pyrazosulfuron-ethyl(7.4X) 1 ppb: Linuron(5.2X) ( 1,) ( 1) ( 1,) ESI+ 336.2>238. 1.25 ESI+ 415.2 >182.1 ESI 246.9 >16. 1.25 84 1. 1..75.75.5 84 1. 84.5.5.25.25 83 83 83... 18. 19. min 5.5 6. 6.5 7. min 14. 14.5 15. min Liquid Chromatograph Mass Spectrometer 7
Ultra-High Reliability to Withstand Wide Range of Complex Matrices Exceptional Durability Blood plasma samples were spiked with verapamil and warfarin, and then deproteinized according to the pretreatment process indicated below. The area values from 45 consecutive analyses were then plotted. Simultaneous analysis of verapamil by ESI+ and warfarin by ESI was performed. Chromatograms for the 1st, 25th, and 45th measurements are shown below. This resulted in 1 pg on-column area repeatability of 4.18 % for verapamil and 6.61 % for warfarin. Area 1 4 3. 2.5 2. 1..5 Verapamil Warfarin Column: Shim-pack XR-ODS II (2. mmi.d. 5 mml, 2.2 µm) Mobile Phase A: 5 mmol/l ammonium acetate water Mobile Phase B: Acetonitrile Gradient Program: 6 %B ( min) 9 %B (1 3. min) 6 %B (3.1 4.5 min) Flow Rate:.4 ml/min.. 5 1 15 2 25 3 35 4 45 Injection 2 µl plasma sample Add 2 µl Acetonitrile, 5 µl 5 % methanol aqueous solution and 5 µl verapamil and warfarin standard solutions. Vortex and centrifuge (1 rpm, 3 min.) followed by freeze drying. Add 5 µl dilution solution. Vortex and centrifuge (12 rpm, 5 min.). ( 1,) 6. 5. 4. 3. 2. 1.. ( 1,) ( 1,) 1 st injection 6. 5. 4. 3. 2. 1.. 25 th injection 6. 5. 4. 3. 2. 1.. 45 th injection.3.4.5.6.7 min.3.4.5.6.7 min.3.4.5.6.7 min Ultra Fast Speed Combined with Lower Femtogram Detection Using the same chromatography parameters as described above, analysis of plasma samples spiked with 4 fg/µl verapamil and warfarin were injected into the for signal to noise determination. For 1 fg on-column, a S/N ratio of 146 (rms) was obtained for verapamil and 3 (rms) for warfarin. The resulting lower limits of detection for S/N = 3 (rms) were 2.5 fg for verapamil and 9.88 fg for warfarin. 12 1 8 6 4 Verapamil Warfarin 455.25 >165.5(+) 3 37.2 >16(-) 25 2 15 1 Compounds Verapamil Warfarin S/N: 1 fg on column (rms) 146 3 LOD(fg) Calculated at S/N = 3 2.5 9.88 2 5.25.5 min.5.75 1. min Chromatograms of 1 fg Verapamil and Warfarin On-Column 8 Speed Beyond Comparison Enhanced Sensitivity
Single Vendor Solution Provides Seamless Operation LabSolutions LCMS Version 5 LabSolutions LCMS Version 5 is integrated workstation software used to control LCMS-22/83/84 systems. Full HPLC control is included for LC-VP and Prominence modules, and for the Nexera UHPLC series. Standard data processing features include a Quantitation Browser, which is useful for quantitative processing of multiple analytes, and a Data Browser for overlaying chromatograms. The Data Browser allows the user to analyze and compare multiple sets of data, such as peak detection data or LCMS spectra in the same window. It also allows LC and MS data to be linked, which is especially useful when searching for or identifying compounds. In addition, the popular report function was expanded to enable printing results in a wider variety of formats. Automatic MRM Optimization Optimizing MRM parameters is an important step when creating quantitative methods for triple quadrupole mass spectrometers. LCMS-83/84 systems optimize MRM parameters using automated flow injection analysis, an optimization function included LabSolutions that allows anyone to optimize parameters easily. Entering precursor ions Selecting parameters to optimize Unknown product ions Optimization results Optimization choices include voltages for Q1 pre-rod, Q3 pre-rod, and Collision Energy. CE optimization finds the optimal value by first searching a wide range at 5 volt steps, then searching again within a ±5 V range around the highest intensity value at 1 volt steps. MRM transitions are determined by selecting the product ions with the highest abundance. This entire series of measurements is performed automatically and a number of analytes can be optimized in an unattended batch run. Optimization results are automatically reflected in method files, and shown in the window above. Values indicated as "Selected" are the selected product ions. The user can easily make edits to the final method. If a product ion is unknown, the software automatically searches for the ion. Liquid Chromatograph Mass Spectrometer 9
Powerful Workflow Solutions LC/MS/MS Method Packages When performing quantitation, system parameters must first be optimized. Shimadzu offers various method packages to eliminate the need for MRM determination and chromatographic method development. Residual Pesticides No. of compounds: 167 Veterinary Drugs No. of compounds: 42 Water Quality Analysis No. of compounds: 44 (Golf Course Pesticides), 32 (Pesticides Targeted for Water Quality Control) Ready-to-Use Methods Shimadzu s method packages contain LabSolutions method files, which include pre-registered MRM parameters with optimized quantitative and reference ions, LC separation parameters, and retention times and peak identification parameters for various compounds. Report templates for outputting quantitation results are also included. By using these method packages, a laboratory can save a great deal of method development time. Methods Easily Customized LabSolutions LCMS Version 5 now allows the transfer of individual MRMs from one method to another. Adding, deleting, and editing of compounds is easily accomplished in an intuitive format. Method packages also include a compound parameter list created in Excel, which enables the creation of new tables that list only the components needed. LC/MS/MS Method Package for Drugs of Abuse: 286 compounds The drugs of abuse method package was developed for both quantitative and qualitative drug screening analysis. The speed of Shimadzu s LCMS allows product ion scans for qualitative confirmation to be employed during MRM quantitation. Shimadzu refers to the use of an MRM response to trigger a product ion scan as Synchronized Survey Scanning (SSS). This method package includes SSS methods for 87 illicit drugs, 15 psychotropics, 7 hypnotics, and 24 other substances, based on input from researchers. In addition, it includes a library populated with compound information and product ion scan spectra for a total of 286 compounds. MRM parameters and product ion spectra measurement parameters have been optimized for each compound. Finally, because of the ease with which methods may be edited, new analytical methods for a shorter list of compounds can easily be generated. ( 1,) 6. 5. 4. 3. 2. 1. Injection Illicit drugs.. 3. 3.5 4. 4.5 5. 5.5 min MRM chromatograms Psychotropics Hypnotics 1 Compounds in Digest Inten.( 1,) Zolpidem CH3 N 235 2. CH3 H3C N N O CH3 1. Other Method selection 221 Illicit drugs Psychotropics Hypnotics 1 digest Other 263 38 2 25 3 m/z MS/MS spectrum 1 Speed Beyond Comparison Enhanced Sensitivity
Profiling Solution Version 1.1 Compatible with LCMS-IT-TOF, LCMS-22/83/84, and GC-MS Data Data File Profiling Solution is software for comparing and contrasting the vast amount of data obtained from multiple chromatographic sets. It extracts and tabulates all peaks found in multiple data files to create the peak tables required for multivariate analysis. Furthermore, Profiling Solution is compatible with both LC-MS and GC-MS instruments, which allows supporting multivariate analysis using a wide variety of analytical methods. Detected Peak Analytical Instrument Multiple Data Data Table Multivariate Analysis Software Optional Ion Source Changing between ESI, APCI and DUIS interface is a completely tool-free operation. APCI DUIS Sample injection ESI probe Corona needle Corona needle Liquid Chromatograph Mass Spectrometer 11
Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 212 Printed in Japan 3655-5211-7ANS