Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Similar documents
Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

of mass spectrometry

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

HILIC Method Development in a Few Simple Steps

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. You are productive solving your chromatography challenges

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Confirmation and Quantitation of THC in Oral Fluid Using an MRM Method on a GC-Triple Quadrupole MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Thermo Scientific TriPlus RSH Autosampler Integrated Sampling System. you are productive. solving your chromatography challenges

Introduction to Fourier Transform Infrared Spectroscopy

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Thermo Scientific GasBench II

Automated and accurate component detection using reference mass spectra

Fast, Effective XPS Point Analysis of Metal Components

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Introduction to Fourier Transform Infrared Spectroscopy

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

Analysis of Alkylphenols Using GC-MS/MS and Automated SRM Development

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Nitrogen/Protein determination of infant food by the Thermo Scientific FlashSmart Elemental Analyzer using helium or argon as carrier gases

Monitoring Protein PEGylation with Ion Exchange Chromatography

for XPS surface analysis

Application Note GCMS-03 Reliable high-throughput quantification of melamine and related analogs below regulatory limits in food using the EVOQ GC-TQ

Hydrophilic Interaction Liquid Chromatography: Method Development Approaches

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

IN QUALITATIVE ANALYSIS,

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Determination of urea in ultrapure water by IC-MS/MS

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

MetWorks Metabolite Identification Software

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

[ Care and Use Manual ]

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

Determination of Carbon d13c isotopic composition from DIC samples

GC-MS Screen for the Presence of Melamine, Ammeline, Ammelide and Cyanuric Acid

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Analysis of Plasticizer Contaminants in Beverages and Milk using an Automated System Based on Turbulent-flow Chromatography Coupled to LC-MS/MS

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Advances in Sample Preparation for Accelerated Solvent Extraction

Analysis of Silicone Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

Elemental Analysis: CHNS/O characterization of polymers and plastics

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

MiSeq System. Denature and Dilute Libraries Guide

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

Transcription:

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis A. Caruso, M. Santoro, P. Magni, S. Pelagatti, and R. Facchetti Thermo Fisher Scientific, Milan, Italy

Overview Purpose: Exploring the possibility to perform the sample preparation steps necessary for the derivatization of analytes in a fully automated and reliable way with the use of the same robotic sampler used for sample injection into the gas chromatograph. Methods: As an example of application, we screened dairy products for melamine and its derivates presence via GC-MS/MS. Results: The outcomes are positive, and precise results show it is possible to reliably automate sample preparation operations with full automatization of GC-MS analysis. Introduction Sample derivatization is often used in GC and GC/MS analyses to enhance the volatility of certain compounds. Strong intermolecular attractions between polar groups such as NH, SH or OH, groups can create hydrogen bonds that lead to molecular attraction and reduce volatility. Replacing hydrogen in these groups by alkylation, acylation, or silylation significantly increases volatility, especially in compounds with multiple polar groups. Typically, the replacement of active hydrogens with trimethylsilyl groups leads to volatile derivatives that can readily undergo GC analysis. A typical silylation reaction requires the addition of a reagent such as MSTFA, TMCS, or BSTFA in presence of a base in an anhydrous and heated environment and may last several minutes. The length of the reaction, and the fact that often these additions of liquid reagents must be carried out manually are downsides of the process and negatively affect overall laboratory throughput. The introduction of a system capable of handling much of the sample preparation process automatically can increase laboratory throughput and free the operator from the most tedious, time-consuming and error-prone steps. The Thermo Scientific TriPlus RSH autosampler is an example of such a system. The TriPlus RSH autosampler is a versatile automatic sampling platform that is also capable of advanced sample preparation cycles, enabling excellent precision and reproducibility and ensuring unattended and reliable operations. 2 Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

FIGURE 1. TriPlus RSH autosampler, Thermo Scientific TRACE 1310 GC and TSQ 800 mass spectrometer Preparation Cycles The TriPlus RSH has the capability to perform sample preparation by using prep cycles. Prep cycles are precompiled, software-driven sets of operations for the TriPlus RSH autosampler that allow users to go beyond standard injection functions. Using prep cycles, the instrument can perform sample preparation procedures, such as calibration curve building, dilutions or derivatizations in an unattended, reliable and fully automated fashion. The TriPlus RSH autosampler can automate these cycles with the innovative Automatic Tool Changing Station (ATC), which can hold multiple syringes and automatically change them, as an example for switching from liquid to headspace to SPME analyses in the same sequence or simply to handle different liquid volumes with the utmost precision (See Figure 2.) FIGURE 2. TriPlus RSH ATC station. Thermo Scientific Poster Note PN10388_ISCC_2014_E_05/14S 3

The derivatization prep cycle can handle the entire process unattendedly and reliably. It offers the possibility of adding derivatizating agents and internal standards, vortexing and incubating samples into an oven or into cooled trays, according to the protocol followed, for a user-selectable time. At the end of a derivatization batch, samples can be automatically injected by the same sampler into a GC or a GC/MS. The derivatization prep cycle is able to handle liquid volumes for samples, standards, and reagents between 1 ml and 10 ml, choosing the proper syringes accordingly, and can work with vial volumes from 2 100 ml, offering the possibility to scale down the volumes used, thus saving money and reducing the chemical waste generated. Automation of Sample Derivatization Procedures in Food Safety Studies The cycle has been used to perform the derivatization step and the injections for the analysis of melamine, cyanuric acid, ammeline, and ammelide by GC-MS in milk products. The sample preparation procedure is carried out manually, in parallel, to validate the results obtained. Melamine is an industrial chemical, commonly used in the manufacture of plastics and colorants; cyanuric acid, ammeline, and ammelide are the metabolites found after ingestion of melamine (Figure 3). With GC-MS/MS, it is possible to determine the content of the four compounds with excellent sensitivity and specificity. The extracted samples must be derivatizated before the analysis. FIGURE 3. Structure of melamine, cyanuric acid, ammelide, and ammeline. Methods The sample preparation and analysis has been performed with the TriPlus RSH autosampler coupled with a TRACE 1310 Gas Chromatograph and a TSQ 8000 triple quadrupole mass spectrometer. The data were collected and processed with Thermo Scientific Xcalibur data system. 4 Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Sample Preparation Common retail milk products were analyzed in parallel with standard solutions of the four analytes, plus the internal standard, prepared at various concentrations. Sample derivatization has been executed manually and via the TriPlus RSH autosampler to compare the results obtained. The sample extraction protocol used follows the US FDA methods for the screening of melamine, ammelide, ammeline, and cyanuric acid (version 2.1) [1] The TriPlus RSH autosampler is used to add 300 µl of a solution of acetonitrile and pyridine (1:1) to the sample extract and then the vial is vortexed for 30 seconds. Next, 200 µl BSTFA with 1 % TMS is added to the vial and is vortexed for 1 min and then incubated at 70 C for 45 min. The previous operation, like the subsequent GC/MS injection, is performed in an unattended fashion by the autosampler. The user must have the requested hardware configuration and syringes, load the samples and reagents onto the tray, and load the prep cycle into a CDS sequence and run it for the number of samples to be analyzed. The entire sample preparation procedure uses the first line of the sample sequence; after that, the usual injection sequence occurs. FIGURE 4. Xcalibur CDS samples calibration sequence. FIGURE 5. Automated Derivatization Prep cycle user interface. Gas Chromatography Oven: starting temperature 75 C for 1 minute, raise to 300 at 15 C/min, hold for 10 minutes Injector: 250 C, carrier gas Helium 1 ml/min, splitless mode for 120 seconds Column: Thermo Scientific TRACE TR5-MS 30 m x 0,25 cm x 0,25 µm Thermo Scientific Poster Note PN10388_ISCC_2014_E_05/14S 5

Mass Spectrometry The TSQ 8000 mass spectrometer was operated in SRM mode with retention times, collision energies, and precursor ions optimized for each analyte. The temperature of transfer line and ion source were, respectively 250 C and 270 C. Results None of the analyzed commercially available milk samples were positive for the presence of melamine or the other target compounds. A milk sample was spiked with the target analytes at a concentration of 12 ppb each and tested via GC-MS/MS. Standard solutions of the four analytes were analyzed at concentrations of 2.5, 5, 10, 50, and 100 ppb each, and showed excellent results in terms of linearity. FIGURE 6. Linearities for melamine and cyanuric acid shown as examples. The results for the milk samples, the standard spiked samples, and the standard solutions obtained with the derivatization procedures done manually were in line with those obtained using the TriPlus RSH autosampler prep cycle. FIGURE 7. SRM results for the compounds screened. 1.) Melamine, 2.) Cyanuric Acid, 3.) Ammeline, 4.) Ammelide. 6 Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Conclusion The TriPlus RSH autosampler is a versatile automatic sampling system that is also capable of advanced sample preparation cycles, enabling excellent precision and reproducibility and ensuring unattended and reliable operations. The powerful platform comprised of the TriPlus RSH autosampler, a TRACE 1300 Series GC, and TSQ 8000 MS, is a sensitive and reliable analytical system capable of derivatizing and analyzing a high number of samples unattendedly, improving laboratory throughput with excellent analytical performances. An example has been shown of the automated derivatization procedure for the determination of contaminants like melamine and related by-products in milk, which provided outstanding linearity and recoveries. Similar automated cycles could be used to accelerate the derivatization procedures for biological and food samples prior to GC and GC/MS analysis, reducing operator time and the chance for errors, minimizing carryover, and reducing the amounts of chemicals used and waste generated, thus decreasing the cost of chemical waste handling. References 1. FDA GC-MS Screen for the Presence of Melamine, Ammeline, Ammelide and Cyanuric Acid. www.thermoscientific.com 2014 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa +43 1 333 50 34 0 Australia +61 3 9757 4300 Austria +43 810 282 206 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China 800 810 5118 (free call domestic) 400 650 5118 Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland +358 9 3291 0200 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9494 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 1 333 50 34 0 Thermo Fisher Scientific, Austin, TX USA is ISO 9001:2008 Certified. Singapore +65 6289 1190 Spain +34 914 845 965 Sweden +46 8 556 468 00 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 PN10388_E 05/14S