SWARM ABSOLUTE SCALAR AND VECTOR MAGNETOMETER BASED ON HELIUM 4 OPTICAL PUMPING

Similar documents
An isotropic earth field scalar magnetometer using optically pumped helium 4

On the calibration of a vectorial 4 He pumped magnetometer

The Swarm Vector Field Magnetometer (VFM): instrument commissioning & performance assessment José M. G. Merayo

The NMR Inverse Imaging Problem

Chemistry 431. Lecture 23

Overhauser Magnetometers For Measurement of the Earth s Magnetic Field

Magnetic Field measurements with Csmagnetometers

Optical Pumping in 85 Rb and 87 Rb

Fundamental MRI Principles Module Two

Fundamental MRI Principles Module 2 N. Nuclear Magnetic Resonance. X-ray. MRI Hydrogen Protons. Page 1. Electrons

On Electron Paramagnetic Resonance in DPPH

Atomic magnetometers: new twists to the old story. Michael Romalis Princeton University

Nuclear spin maser with a novel masing mechanism and its application to the search for an atomic EDM in 129 Xe

Micromechanical Instruments for Ferromagnetic Measurements

Progress on the Design of the Magnetic Field Measurement System for elisa

NMR, the vector model and the relaxation

Electron Paramagnetic Resonance

Schematic for resistivity measurement

NMR Spectroscopy Laboratory Experiment Introduction. 2. Theory

EQUIPMENT INTERFACE LOAD CHARACTERIZATION IN ACOUSTICS

Laser MEOP of 3 He: Basic Concepts, Current Achievements, and Challenging Prospects

Introduction to MRI. Spin & Magnetic Moments. Relaxation (T1, T2) Spin Echoes. 2DFT Imaging. K-space & Spatial Resolution.

NMR of CeCoIn5. AJ LaPanta 8/15/2016

Optical Magnetometry Using Nitrogen-Vacancy Centers

LONG-LIVED QUANTUM MEMORY USING NUCLEAR SPINS

Double-Resonance Experiments

COPYRIGHTED MATERIAL. Production of Net Magnetization. Chapter 1

Bioengineering 278" Magnetic Resonance Imaging" Winter 2010" Lecture 1! Topics:! Review of NMR basics! Hardware Overview! Quadrature Detection!

Part I. Principles and techniques

Optical pumping of rubidium

Development of Testing Methods for Absolute Magnetometers and Some Test Results of the Overhauser Magnetometer POS-1

THE MAGSAT SCALAR MAGNETOMETER

NUCLEAR MAGNETIC RESONANCE. The phenomenon of nuclear magnetic resonance will be used to study magnetic moments of nuclei.

Electron spins in nonmagnetic semiconductors

Piezoelectric Actuator for Micro Robot Used in Nanosatellite

Introduction of Key Concepts of Nuclear Magnetic Resonance

An introduction to Solid State NMR and its Interactions

HYPERFINE STRUCTURE CONSTANTS IN THE 102D3/2 AND 112D 3/2 STATES OF 85Rb M. GLOW

Spin resonance. Basic idea. PSC 3151, (301)

Lecture 4 Scanning Probe Microscopy (SPM)

High Sensitivity Optically Pumped Quantum Magnetometer

Supplemental Material to the Manuscript Radio frequency magnetometry using a single electron spin

Nuclear Magnetic Resonance Imaging

Precision Interferometry with a Bose-Einstein Condensate. Cass Sackett. Research Talk 17 October 2008

Ion traps. Trapping of charged particles in electromagnetic. Laser cooling, sympathetic cooling, optical clocks

Biomedical Imaging Magnetic Resonance Imaging

Compendium of concepts you should know to understand the Optical Pumping experiment. \ CFP Feb. 11, 2009, rev. Ap. 5, 2012, Jan. 1, 2013, Dec.28,2013.

Topics. The concept of spin Precession of magnetic spin Relaxation Bloch Equation. Bioengineering 280A Principles of Biomedical Imaging

Last Name _Piatoles_ Given Name Americo ID Number

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar.

Magnetic Resonance Spectroscopy EPR and NMR

Electromagnetics in COMSOL Multiphysics is extended by add-on Modules

Nuclear Magnetic Resonance Imaging

Precision Spectroscopy of Excited. States in Rubidium

MIT Department of Nuclear Science & Engineering

The Theory of Nuclear Magnetic Resonance Behind Magnetic Resonance Imaging. Catherine Wasko Physics 304 Physics of the Human Body May 3, 2005

Zeeman Effect. Rabia Aslam Chaudary Roll no: LUMS School of Science and Engineering. Friday May 20, 2011

OPTICAL GAIN AND LASERS

DYNAMIC ROTARY TORQUE MEASUREMENT USING SURFACE ACOUSTIC WAVES

Sensors: a) Gyroscope. Micro Electro-Mechanical (MEM) Gyroscopes: (MEM) Gyroscopes. Needs:

In-Situ Observation of the Phase of a Microwave Field using Single-Atom Nonlinear Optics

Electron spin resonance

A Hands on Introduction to NMR Lecture #1 Nuclear Spin and Magnetic Resonance

Geology 228/378 Applied & Environmental Geophysics Lecture 8. Induced Polarization (IP) and Nuclear Magnetic Resonance (NMR)

Optical pumping and the Zeeman Effect

Electron Spin Resonance. Laboratory & Computational Physics 2

Supplementary Information

Zeeman Effect. Alex Povilus Physics 441- Fall 2003 December 20, 2003

A GENERALIZED THEORY OF DOUBLE-RESONANCE LASER-PUMPED HELIUM-4 MAGNETOMETERS. Michael K. Plante

Supplementary Information to Non-invasive detection of animal nerve impulses with an atomic magnetometer operating near quantum limited sensitivity.

440. Simulation and implementation of a piezoelectric sensor for harmonic in-situ strain monitoring

Theory of double resonance magnetometers based on atomic alignment

Citation IEEE Transactions on Magnetics (201.

Time Resolved Faraday Rotation Measurements of Spin Polarized Currents in Quantum Wells

V27: RF Spectroscopy

The steady state magnetic resonance absorption signal: a common. Department of Physics, University of Utah, 115 S E.

BUILDING LOW-COST NANO-SATELLITES: THE IMPORTANCE OF A PROPER ENVIRONMENTAL TESTS CAMPAIGN. Jose Sergio Almeida INPE (Brazil)

The Physical Basis of the NMR Experiment

Excitation of high angular momentum Rydberg states

Ultrasensitive Atomic Magnetometers

Cambridge International Examinations Cambridge International Advanced Subsidiary and Advanced Level

Presentation of the Prototype of an Automated DIFlux

NMR Imaging in porous media

Gravity Probe B Data Analysis Challenges, Insights, and Results

Biophysical Chemistry: NMR Spectroscopy

Optical Pumping in Rubidium

PROGRESS TOWARDS CONSTRUCTION OF A FERMIONIC ATOMIC CLOCK FOR NASA S DEEP SPACE NETWORK

Some Topics in Optics

Ruby crystals and the first laser A spectroscopy experiment

MR Fundamentals. 26 October Mitglied der Helmholtz-Gemeinschaft

Journal of System Design and Dynamics

Optics, Optoelectronics and Photonics

Supplementary Figure 1. Spin-spin relaxation curves for three La 1.8-x Eu 0.2 Sr x CuO 4 samples.

Stimulated Emission. Electrons can absorb photons from medium. Accelerated electrons emit light to return their ground state

ELECTRON SPIN RESONANCE & MAGNETIC RESONANCE TOMOGRAPHY

Attitude Determination and Control System Design for STU-2A Cubesat and In-Orbit Results

KCET PHYSICS 2014 Version Code: C-2

Disordered Solids. real crystals spin glass. glasses. Grenoble

Measuring Spin-Lattice Relaxation Time

Practical work: Active control of vibrations of a ski mock-up with a piezoelectric actuator

Transcription:

SWARM ABSOLUTE SCALAR AND VECTOR MAGNETOMETER BASED ON HELIUM 4 OPTICAL PUMPING Jean-Michel Leger (1), François Bertrand (1), Thomas Jager (1), Matthieu Le Prado (1), Isabelle Fratter (2), Jean-Claude Lalaurie (2) (1) CEA, LETI, MINATEC, F38054 Grenoble, France Email : jean-michel.leger@cea.fr (2) Centre National d'etudes Spatiales 18 Avenue Edouard Belin, 31401 Toulouse Cedex 9, France Email : isabelle.fratter@cnes.fr INTRODUCTION The Absolute Scalar Magnetometer (ASM) developed by CEA-LETI in partnership with CNES is an optically pumped 4 He magnetometer which shall provide absolute scalar measurements of the magnetic field with high accuracy and stability for the calibration of the Vector Field Magnetometer (VFM) developed by the Danish National Space Center. In addition and on an experimental basis the ASM will be able to operate as a vector field magnetometer. Both operating principle and related performances are detailed in the following paragraphs. ASM OPERATING PRINCIPLE Scalar field measurement The ASM is an optically pumped 4 He magnetometer based on an electronic magnetic resonance whose effects are amplified by a laser pumping process [1-2], as detailed on Fig. 1. A fraction of the atoms of a 4 He gaz cell are first excited to the 2 3 S 1 metastable state by means of a high frequency discharge. This energy level is split by the static magnetic field B 0 into three Zeeman sublevels. As the energy gap E between the levels is directly proportional to the ambient scalar field B 0, its determination allows the measurement of B 0 (1). E = γħb 0 where γ is the 4 He gyromagnetic ratio for the 2 3 S 1 state [3] (1) The measurement of B 0 is then performed by exciting and detecting the paramagnetic resonance between the Zeeman sublevels. To generate the resonance an oscillating radiofrequency field B 1 is applied on the 4 He gaz cell: when its frequency matches the Larmor frequency of the Zeeman sublevels (ω 0 = γb 0 ) the magnetic resonance occurs and transitions are induced between the sublevels. Fig. 1. 4 He energy diagram and ASM principle of operation

However, at thermal equilibrium the sublevels are almost equally populated and no significant change induced by the resonance can be detected. To finally enhance and detect the resonance, a selective pumping from one of the Zeeman sublevel to the 2 3 P 0 state is performed thanks to a frequency tuned linearly polarized laser light. The resulting disequilibrium between the Zeeman sublevels populations improves the resonance signal amplitude by several orders of magnitude while the monitoring of the intensity of the laser light transmitted through the 4 He cell allows its detection. Vector field measurement The ASM magnetometer can also provide a vector measurement of the magnetic field using the information provided by the superimposition of 3 low frequency orthogonal magnetic fields onto the B 0 field seen by the 4 He sensing cell (2). ρ B tot = ρ B 3 j ρ 0 + β cos( ω jt) e j (2) j= 1 The vector measurement is simply obtained by processing the scalar output measurement containing the principal harmonics at the ω j pulsations. The vector field reconstruction in the ASM reference frame is finally achieved thanks to a specific calibration process [2] from which the vector modulation amplitudes β j and their respective orientations e j in the ASM frame are derived. ASM HARDWARE ARCHITECTURE To take full advantage of the scalar magnetometer performances we defined an architecture that is free of the orientation effects common to all standard scalar magnetometers based on magnetic resonance. Each of the following processes has to be taken into account to guarantee the sensor isotropy: the distribution of atoms on the three sublevels 2 3 S 1 resulting from optical pumping cycle is directly depending on the relative orientation θ F between the static magnetic field B 0 and the polarization of the laser E 0. only the component of the radiofrequency field B 1 orthogonal to the magnetic field B 0 actually induces resonating transitions between Zeeman sublevels. for a linearly polarized pumping beam, the amplitudes of the resonance signals used for the magnetic field B 0 measurement reach an extremum when the polarization direction E 0 is perpendicular to the magnetic field B 0. We have finally chosen to control the beam polarization direction through a rotation of a polarizer placed in front of the 4 He cell and we have also designed the radiofrequency excitation coils so that the resulting radiofrequency field is parallel to the linear polarizer: whatever the relative orientation of the sensor with respect to the magnetic field direction, both polarisation E 0 and radiofrequency field B 1 directions can always be adjusted perpendicularly to the static field B 0. The resulting magnetometer is thus perfectly isotropic. The final instrument assembly consists of an electronic box (Digital Processing Unit) installed within the platform and a sensor mounted at the tip of the boom (to minimize the magnetic perturbations from the satellite) connected to the electronic box by a bundle of optical fibers and electrical cables (harness). As a cold redundancy has been required for the instrument, a specific sensor bracket has been designed to mechanically interface two identical sensors with the satellite boom, each sensor being connected to a dedicated DPU. Both ASM sensor and ASM DPU functional architectures are depicted on Fig. 2. The ASM sensor is made of: a PEEK based rotor comprising: - the 4 He cell containing a low pressure helium gas which is the sensing part of the sensor - HF electrodes used to apply an electric discharge to the 4 He gas thus transferring some of the atoms from the 1 1 S 0 ground state to the 2 3 S 1 metastable level - RF coils used to apply a RF field to the excited helium atoms to induce the magnetic resonance between the Zeeman sublevels of the 2 3 S 1 metastable level - a linear polarizer whose rotation ensures optimal pumping conditions of the 4 He gas - a retro reflector used to reflect the laser light back through the cell to the DPU

Fig. 2. ASM functional architecture a PEEK based stator comprising : - the totally amagnetic piezoelectric motor used to drive the rotor and so keep a constant θ F = 90 angle between both polarization and RF field directions and the ambient magnetic field - rotating transformers to ensure contactless electrical connections to the HF electrodes and RF coils integrated on the rotor - a temperature sensor probe - three orthogonal vector coils for the vector mode. The ASM DPU is divided in two stacked modules: the first module consists of the optical part of the DPU (a 1083 nm laser synthesis and the optical interface with the sensor) and the primary to secondary power DC-DC converters. This module can be divided into three subsystems: - an electronic card delivering the secondary voltages (±5V, +3,3V) to all the electronic circuits of the DPU. - the laser source which delivers optical power to the sensor including a Laser Fiber Assembly using a fiber Bragg grating laser whose wavelength can be tuned on the D 0 transition (2 3 S 1-2 3 P 0, λ ~ 1083 nm) thanks to a piezoelectric actuator. - the optical interface circuit including the pump laser diode, photodiodes and their dedicated low noise amplifiers and the electrical bonding for the piezoelectric actuator. the second module contains the main digital and analog circuits, and regroups most of the electrical interfaces with the sensor and the satellite : - the main digital core - electrical interfaces and a test socket - the different data acquisition and signal processing modules - the RF, HF, laser, piezoelectric motor and vector mode drivers Since this CEA-LETI magnetometer technology will be launched and operated in space for the first time, all ASM elements have been validated with respect to the environment specifications of the SWARM mission. A number of ASM specific and complex components such as the fiber Bragg grating laser have been successfully developed and qualified. A picture of the final ASM components including the ASM sensor assembly, the ASM DPU and the optical and electrical harnesses is given in Fig. 3. The different ASM flight models are currently being manufactured and will be available for the SWARM satellites integration in 2010.

Fig. 3. ASM sensor assembly and ASM DPU ASM PERFORMANCES ASM scalar performances Compared to the Overhauser based scalar sensors previously used for the Ørsted and CHAMP missions [4], the scalar resolution has been enhanced to 1 pt/ Hz and the scalar bandwidth previously limited to a few tenths of Hz can be increased up to 300 Hz. For the SWARM mission, the scalar bandwidth has been tuned to 100 Hz so that vector modulations frequencies can be adjusted over a large frequency range below 100 Hz. The ASM scalar bandwidth and resolution are illustrated on Fig. 4. 10 1 10 0 10-1 ASM mean resolution in the [5 Hz -25 Hz] frequency band: 0.915 pt/ Hz ASM bandwidth: 100 Hz DSP in nt/ Hz 10-2 10-3 10-4 10-5 10-6 0 50 100 150 200 250 300 350 400 450 500 frequency in Hz Fig. 4. ASM scalar bandwidth and resolution

Anisotropy : ASM-NMR scalar differential (pt) -50-100 -150-200 -250-300 -350 ASM anisotropy : in-orbit configuration Measurement Corrective modeling Remanent and induced contribution in the ASM anisotropy modeling Induced Remanent 150 100 50 0-50 -100-150 -200 Value in pt -400-150 -100-50 0 50 100 150 Rotation in -150-100 -50 0 50 100 150 Rotation in Fig. 5. ASM anisotropy and associated Algo1B corrective modeling for the in-orbit configuration of the ASM sensor The specific ASM errors affecting the scalar magnetic field measurement have been identified and characterized: - the ASM sensor anisotropy, - the vector modulations aliasing (in vector mode only), - the Bloch-Siegert effect [5], - the measurement datation error, - the Pulse Per Second (PPS) time reference accuracy For example the ASM sensor assembly has been characterized and an associated corrective model including both remanent and induced magnetic field contributions has been derived: the results of this characterization for the in-orbit ASM sensor assembly configuration is given on Fig. 5. We could see that the main contribution on the ASM sensor assembly anisotropy is given by a induced magnetic field contribution: although the sensor assembly has been designed and realized with amagnetic materials such as PEEK, their magnetic susceptibilities are not equal to zero (magnetic susceptibilities χ range between 10-6 and 10-5 SI). The measured and calculated maximum error contributions are given in the following table. Corresponding maximum remaining errors after the ASM level 1B algorithms corrections are also given and a final maximum quadratic remaining error on the absolute accuracy about 50 pt is demonstrated. Additional error contributions such as the satellite magnetic moment and the magnetocouplers effect will be corrected at satellite level with the SWARM satellite level 1B algorithms. -250 Error type ASM error before correction Bloch-Siegert error 55 pt (@ 46 µt) Vector aliasing 23 pt (@ 46 µt) ASM in-orbit anisotropy 120 pt PPS precision (5.10-7 x B 0 ) (worst case) 32,5 pt (@ 65 µt) Datation (1 ms x 30 nt/s) (worst case) 30 pt 32,5 pt Remaining error after ASM 30 pt < 5 pt < 5 pt < 25 pt (@ 65 µt) level 1B algorithm correction (instrument error, not (system error, not corrected in the level 1B corrected in the level algorithms) 1B algorithms) Table 1. ASM errors contributions on the scalar measurement (resulting maximum quadratic error σ max : 50 pt)

ASM vector performances While the main objective of the ASM is to provide high resolution scalar measurements for the calibration of the VFM sensor, the ASM is also able to provide in addition vector measurements from its own with a resolution in the nt/ Hz range [2], a vector measurement bandwidth set to 0.4 Hz and a vector absolute precision of about 1 nt. To be properly used, the vector mode has to pass a calibration process detailed in [2], and derived calibration parameters will be used in the ASM vector level 1B algorithm. This is illustrated on Fig. 6 corresponding to the measurements taken during a 3D calibration spiral applied on the ASM sensor, resulting in a preliminary scalar residual lower than +/- 2 nt peak-to-peak. field component (µt) 20 10 0-10 Reconstructed vector magnetic field X Y Z -20 0 0.5 1 1.5 2 2.5 3 time (h) Scalar residual 10 residual (nt) 5 0-5 -10 0 0.5 1 1.5 2 2.5 3 time (h) Fig. 6: preliminary ASM vector calibration (15 µt spiral) CONCLUSION The CEA-LETI has successfully designed and realized an optically pumped 4 He magnetometer which provides absolute scalar magnetic field measurements with a 1 pt/ Hz resolution over a DC to 100 Hz bandwidth. Its final corrected scalar accuracy is better than 50 pt. The ASM instrument is also able to provide vector field measurements with an intrinsic 1 nt/ Hz resolution and a 0.4 Hz bandwidth. All ASM components have been successfully qualified with respect to the environment and performances specifications of the SWARM mission. The different ASM flight models are currently being manufactured and will be delivered for their integration in the SWARM satellites in 2010. REFERENCES [1] Colegrove, F. D. and L. D. Schearer, Optical pumping of helium in the 3S1metastable state, Physical Review, 119, 680 690, 1961. [2] O. Gravrand, A. Khokhlov, J.L. Le Mouël, and J. M. Léger, On the calibration of a vectorial 4He pumped magnetometer, Earth Planets Space, 53, 2001, pp. 949 958. [3] Shifrin V.Y. and al, Experimental Determination of the Gyromagnetic Ratio of the Helium-4 Atom in Terms of that of the Helium-3 Nucleus, IEEE Transactions on Instrumentation and Measurement, Vol.46, No. 2, 1997, pp. 97-100.

[4] D. Duret, J.M. Léger, M. Francès, J.Bonzom and F. Alcouffe, Performances of the OVH Magnetometer For The Danish Oersted Satellite, IEEE Transactions On Magnetics, Vol. 32, No. 5, 1996, pp. 4935-4937. [5] J.A. Hermann and S. Swain, Bloch-Siegert shifts and multi-quantum transitions in spin-one systems, J. Phys. B: Atom. Molec. Phys., Vol 10, No. 11, 1977, pp. 2111-2123.