TOTAL 6 STACK MONITORS ~ GAS, PARTICULATE GROSS BETA-GAMMA ~ IODINE ~ TRITIUM ~ C-14

Similar documents
FEATURES: CAM-TC CAM-TCI

New Test Results For Physical Separation Of Tritium From Noble Gases And It s Implications For Sensitivity And Accuracy In Air And Stack Monitoring

SOUTHERN NUCLEAR COMPANY VOGTLE ELECTRIC GENERATING PLANT UNITS 1 AND 2 NRC DOCKET NOS AND

Radiological Air Sampling NISP-RP-03

Teacher: Mr. gerraputa. Name: Which two radioisotopes have the same decay mode?

New Developments in Tritium Monitors

RADIATION PROTECTION

Design and Use of an Interim Noble Gas Effluent Monitor at Columbia Generating Station

Instruments for Radiation Protection

ESTIMATION OF RADIONUCLIDE RELEASES IN ATMOSPHERE FROM CERNAVODA NPP BASED ON CONTINUOUS GASEOUS EFFLUENT MONITORING

2100TR Liquid Scintillation Counter

AIR SAMPLING PROGRAM/METHODS RCT STUDY GUIDE State the primary objectives of an air monitoring program.

Chem 100 Section Experiment 12 Name Partner s Name. Radioactivity

GUIDE TO LABORATORY SURVEYS. Introduction

SECTION 8 Part I Typical Questions

PHYSICS 176 UNIVERSITY PHYSICS LAB II. Experiment 13. Radioactivity, Radiation and Isotopes

1 of 16 1/28/2014 2:35 PM. Search

Radiation Detection. 15 th Annual OSC Readiness Training Program.

2) Explain why the U-238 disintegration series shown in the graph ends with the nuclide Pb-206.

RANGE OF ALPHAS. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

ARMUG New CAM Developments. Arran Morgan MSc Physicist

Applied Nuclear Science Educational, Training & Simulation Systems

Applied Nuclear Science Educational, Training & Simulation Systems

OVERVIEW OF THE TRITIUM-IN-AIR MONITORING SYSTEM OF CERNAVODA NPP U1 ROMANIA MODERNIZATION AND IMPROVEMENT PROJECT

Unit 13: Nuclear Practice Packet Regents Chemistry: Practice Packet: Unit 13 Nuclear Chemistry

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

Distillation purification and radon assay of liquid xenon

METHOD TEST METHODS FOR MEASURING RADIONUCLIDE EMISSION FROM STATIONARY SOURCES

A Method of Quantifying Noble Gas Releases Douglas Wahl Exelon Limerick Generating Station

Atomic Notation (or Nuclear Symbol): Shorthand for keeping track of protons and neutrons in the nucleus

Survey Meter OD-01 Address: Phone: Fax: URL:

Radioactivity INTRODUCTION. Natural Radiation in the Background. Radioactive Decay

Radioactive effluent releases from Rokkasho Reprocessing Plant (1) - Gaseous effluent -

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

FoodScreen Radiological Food Screening System

A Fast Responding Continuous Tritium-in-Air Monitor with Multi Stream Sampling for Area Monitoring

M E E T I n s t r u m e n t s G.m.b.H.

Gammaspectroscopy at the Loviisa NPP. Laura Togneri,

Development of Continuous Inflow Tritium in Water Measurement Technology by using Electrolysis and Plastic Scintillator

Unit 2. Instrumentation. Experts Teaching from Practical Experience

Impact of Weather House Design on REMP Air Sampler Results. Heather Baxter, Senior Scientist, Duke Energy

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

Noble Gas Control Room Accident Filtration System for Severe Accident Conditions (N-CRAFT)

Performance Characterization of A New Cam System M.J. Koskelo 1, J.C. Rodgers 2, D.C. Nelson 2, A.R. McFarland 3 and C.A. Ortiz 3

IEC Tritium Standard

DOE 2.06 Air Sampling Program/Methods Study Guide 00ICP319 Rev.00 Page 1 of 21

2) Estimate your annual radiation dose from background radiation.

AUTOMATIC AND INTERACTIVE ANALYSIS SOFTWARE FOR BETA- GAMMA COINCIDENCE SYSTEMS USED IN CTBT MONITORING

Fundamentals of Particle Counting

Safety Standards. of the Nuclear Safety Standards Commission (KTA) Monitoring the Discharge of Radioactive Substances from Research Reactors

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

da u g ht er + radiation

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

Detection of Xe135 at Nuclear Reactor of Unit 2, Fukushima Daiichi Nuclear Power Station. November 4, 2011 Tokyo Electric Power Company

Name of research institute or organization: Bundesamt für Gesundheit, Sektion Umweltradioaktivität, Bern

Measurement of induced radioactivity in air and water for medical accelerators

Page 2. Draw one line from each type of radiation to what the radiation consists of. Type of radiation. What radiation consists of

IGCSE Physics 0625 notes: unit 5 Atomic Physics: Revised on 01 December

CHAPTER 4: NUCLEAR INSTRUMENTATION MODULE 2: LOG RANGE DETECTORS

She uses different thicknesses of sheets of paper between the source and the sensor. radioactive source

Protection against environmental ionizing (mainly gamma)

A training overview of basic theory and application of alpha discrimination

SLAC Radioanalysis Laboratory

Radiation Detection and Measurement

Activity 11 Solutions: Ionizing Radiation II

Energy loss of alpha particles - Prelab questions

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

... (1) The diagram shows how aluminium sheet is rolled to form foil of constant thickness. rollers source of radiation

Introduction to gamma spectroscopy on a budget. Daniel Emes SA Radiation

Radiation Glossary. Radioactive material dispersed in the air in the form of dusts, fumes, particulates, mists, vapors, or gases.

CHEMISTRY 130 General Chemistry I. Radioisotopes

Figure 1. Time in days. Use information from Figure 1 to calculate the half-life of the radioactive isotope.

RADIOPHARMACY PURPOSE

Quiz, Physics & Chemistry

L-35 Modern Physics-3 Nuclear Physics 29:006 FINAL EXAM. Structure of the nucleus. The atom and the nucleus. Nuclear Terminology

Phys 243 Lab 7: Radioactive Half-life

UNIQUE SCIENCE ACADEMY

How many protons are there in the nucleus of the atom?... What is the mass number of the atom?... (Total 2 marks)

Series CCR-39S Multi-Throw DC-12 GHz, SP7T & SP8T Latching Coaxial Switch

FLIGHT EVALUATION OF A COMPACT AIRBORNE TRACE GAS ANALYSIS SENSOR PROOF-OF- CONCEPT

APPENDIX H DESCRIPTION OF FIELD SURVEY AND LABORATORY ANALYSIS EQUIPMENT

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

Air Filter Alpha Spectrometry Report

Series CCR-39S Multi-Throw DC-12 GHz, SP9T & SP10T Latching Coaxial Switch

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

Name Date Class NUCLEAR CHEMISTRY. Standard Curriculum Core content Extension topics

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

HOW ADVANCED PYROMETERS INCREASE THERMAL PROCESS REPEATABILITY AND PRODUCT QUALITY

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

RADIOACTIVITY IN THE AIR

Six decades of environmental radioactivity measurements. Sven P. Nielsen

Statistical Uncertainty What, When, Why and How RETS/REMP Workshop Jim Key Key Solutions, Inc.

10-year industry best core warranty. 2-year warranty on balance of unit.

A Brief Overview of Radiation and Analytical Water Testing for Radiological Contaminants.

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

Nuclear Physics. AP Physics B

Transcription:

FEATURES: SIX CHANNEL SIMULTANEOUS MEASUREMENT SENSITIVE TO: H-3 10-7 μci/cc CO2 10-8 μci/cc Organic C-14 10-7 μci/cc READS DIRECTLY IN μci/cc or Bq/l REAL TIME FLOW MEASURMENT DYNAMIC BACKGROUND COMPENSATION ALARM & CAN ACTUATE REMOTE CONTROLS CAN ERATE IN PRESENCE OF OTHER RADIOACTIVE GASES (See Chart) MICRO PROCESSOR ERATION DIGITAL ACCURACY INCLUDES DATA, ANALYSIS, DATA ARCHIVE & DATA RETRIEVAL USB & ETHERNET PORTS RUGGED CABINET TIONAL: CASTER OR SKID MOUNTED CABINET IP33 PWR & BWR Produce Tritium 10 Curie/Giga-Watts per Year

APPLICATION: All six models, the TOTAL-6 Stack Monitors and the CAM-33 are good for Nuclear Power Plants, Stacks, Room Air, etc. They are sensitive, rugged stack or effluent monitors. The TOTAL-6 series stresses Tritium and C-14 detection. The CAM-33 series stresses particulates, Iodine, and Nobel Gas. The CAM-33-6 monitor has the most channels for 6 simultaneous measurements of Gross Beta/Gamma Particulates, Alpha Particulates, Noble Gas, Iodine, Tritium, & C-14. NOTE: See the TOTAL-6 Series Stack Monitor Chart & the flow diagrams included here for details to help you select the detector suite that best serves your need. See Spec Sheet details for the CAM-33 Series. Commercial versions are available for research labs, room air, glove boxes and other applicable uses. TRITIUM & 14 CO 2 MEASURMENT DESCRIPTION: The subtractive balanced chamber electrometer circuit and optional Radon Rejection decreases background effects to negligible levels. The deionized and filtered intake reduces to negligible levels spuriosity based on smokes, dusts, and existing ionization in the air. Inlet and outlet hoses provide return of monitored air to source: interiors of fume hoods and exhaust stacks, etc. All instruments are calibrated at the factory. Calibration check may be performed in the field with a license exempt µcurie level Beta source Measurement Ranges of Optional Detectors From 4 Decade Model 6 Decade Model Tritium 10-7 10-3 10-1 uci/cc Inorganic C-14 10-8 10-4 10-2 uci/cc Organic C-14 10-9 10-5 10-3 uci/cc Alpha particulate 5 x 10-8 10-4 uci/cc

DETECTOR TYPE 1 MINUTE 1 HOUR 10 HOURS 1 DAY 1 WEEK T OF RANGE ALPHA 6 x 10-10 µci/ml 1 x 10-11 µci/ml 3.7 x 10-7 Bq/ml 1 x 10-12 µci/ml 3.7 x 10-8 Bq/ml 6 x 10-13 µci/ml 2.4 x 10-8 Bq/ml 1 x 10-13 µbq/ml 4 x 10-9 Bq/ml 1.0 Bq/ml PARTICULATE BETA-GAMMA 6 x 10-10 µci/ml 1 x 10-11 µci/ml 3.7 x 10-7 Bq/ml 1 x 10-12 µci/ml 3.7 x 10-8 Bq/ml 6 x 10-13 µci/ml 2.4 x 10-8 Bq/ml 1 x 10-13 µbq/ml 4 x 10-9 Bq/ml 1.0 Bq/ml IODINE 3 x 10-9 µci/ml 1 x 10-11 µci/ml 3.7 x 10-7 Bq/ml 1 x 10-12 µci/ml 3.7 x 10-8 Bq/ml 6 x 10-13 µci/ml 2.4 x 10-2 Bq/ml 1 x 10-13 µbq/ml 4 x 10-9 Bq/ml 0.1 Bq/ml GAS- STANDARD RANGE 6 x 10-7 µci/ml 1 x 10-7 µci/ml 3.7 x 10-3 Bq/ml 2.7 x 10-8 µci/ml 1 x 10-3 Bq/ml 1 x 10-8 µci/ml 3.7 x 10-4 Bq/ml 2.7 x 10-9 µbq/ml 1 x 10-4 Bq/ml 10 15 Bq/ml POST- ACCIDENT 4 X 10 21 Bq/ml

SERIES STACK MONITORS Airborne Activity Model TOTAL-6- TCI (1) TOTAL-6- TCO (1) TOTAL-6- TC CAM- 33-1P CAM- 33 CAM- 33-4 CAM- 33-6 Chemical Tritium H3 Form T2, HTO T 2 O YES YES YES NO YES Carbon C-14: Inorganic Organic CO 2 Various YES YES YES YES Particulate Alpha YES Particulate Beta YES YES YES YES Iodine YES YES YES YES Noble Gas: Gross/All YES YES YES YES YES Argon Xenon Krypton Radon RX - RX Number of Channels: YES = Measures Separately RX = Rejects = Optional NOTE: Models TOTAL-6-TCO & TOTAL-6-TCI work best if no other nuclides are present See Spec Sheet details for the CAM-33 series.

SPECIFICATIONS: ELECTRONICS: Circuit: Calibration: Alarm: Remote Alarm: Output: On-Board Computer: Background: Smoke, Dust & Ion Elimination: WEIGHT & DIMENSIONS: See CAM-33 series Spec Sheet for Details Electrometer circuit amplifies net difference between a 2 liter Tritium internal chamber & a background chamber of similar size & configuration. Can be calibrated internally with Tritium (or HTO) & 14 CO 2 gas, OR on a Gamma calibration course; OR can be checked at a single point with an external (not provided) Beta source. Organic Carbon Channel can be calibrated with C-14 disk source. High Level: Red flashing light plus warbling sound System Fault Alarm: White steady light 3 Relays provided for operators use USB Port & ethernet port Optional 0-5 volt or 4-20 ma. Data Archive & Data Retrieval Dimensions: 23"W x 66"H x 36"D Shipping Weight: Essentially eliminated by subtractive balanced chambers. Optional - Radon Rejection Filter and deionizer reduce effects to negligible levels. 635 lbs. Interconnection to / from port of other gas or particulate monitors Serial Printer Higher Tritium Count Rate using Both Proportional Detectors for Tritium Measurement TIONAL: Remote Alarm (audio & visual) (Model RDX-8) includes 25 of cable. Can be used to 500 feet. Casters or Skid Mounted Additional Lead Shielding for Greater Gamma Rejection 4-20 ma for computer.

TOTAL-6-TCI-H 3 TOTAL-6-TCO-H 3

TOTAL-6-TC

CAM-33-4 CAM-33-6