INVESTIGATIONS OF NEUTRON EMISSION IN A COLD FUSION EXPERIMENT IN PALLADI UM

Similar documents
Observation of High Multiplicity Bursts of Neutrons During Electrolysis of Heavy Water with Palladium Cathode Using the Dead-Time Filtering Technique

PRELIMINARY RESULTS OF COLD FUSION STUDIES USING A FIVE MODULE HIGH CURRENT ELECTROLYTIC CELL

Influence of gas conditions on electron temperature inside a pinch column of plasma-focus discharge

SILVER NEUTRON ACTIVATION DETECTOR FOR MEASURING BURSTS OF 14 MEV NEUTRONS

COLD FUSION RESULTS IN BARC EXPERIMENTS

Charged particles from Ti and Pd foils

Anomalous Excess Heat by D 2 O/Pd Cell under L-H Mode Electrolysis

Plasma Accelerator for Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

D-D FUSION NEUTRONS FROM A STRONG SPHERICAL SHOCK WAVE FOCUSED ON A DEUTERIUM BUBBLE IN WATER. Dr. Michel Laberge General Fusion Inc.

NUCLEAR PRODUCTS IN A GAS-LOADIND D/PD AND H/PD SYSTEM

Nuclear reactions produced in an operating electrolysis cell. Abstract

EXCESS HEAT GENERATION, NEUTRON EMISSION, AND CELL VOLTAGE CHANGE IN D 2 O LiOD-Pd SYSTEMS

2012 ANS WINTER MEETING NOVEMBER 11-15, 2012

Development of portable neutron generators based on pinch and plasma focus discharges 1

Yasuhiro Iwamura, Takehiko Itoh, Nobuaki Gotoh and Ichiro Toyoda

Reproduction of Fleischmann and Pons experiments

25. Corroborating Evidence for "Cold" Fusion Reaction

STUDIES OF ELECTROLYTIC AND GAS PHASE LOADING OF PALLADIUM WITH DEUTERIUM

ANOMALOUS ENHANCEMENT OF DD-REACTION, ALPHA- EMISSION AND X RAY GENERATION IN THE HIGH- CURRENT PULSING DEUTERIUM GLOW-DISCHARGE WITH

Neutron Burst Emissions from Uranium Deuteride and Deuterium-loaded Titanium

EVIDENCE FOR PRODUCTION OF TRITIUM VIA COLD FUSION REACTIONS IN DEUTERIUM GAS LOADED PALLADIUM

Monte Carlo simulations of neutron and photon radiation fields at the PF 24 plasma focus device

Teflon lid. O ring. Catalyst. Catalyst Chamber. Electrolyte (H 2 SO 4 + de-ionized H 2 0)

Alternate Interpretation of the Original Fleischmann and Pons Experiments

Calibration and applications of modern track detectors CR-39/PM-355 in nuclear physics and high temperature plasma experiments

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

Six Ion Gun Fusion Experiment (SIGFE) Findings and Future Work

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

Dedicated Arrays: MEDEA GDR studies (E γ = MeV) Highly excited CN E*~ MeV, 4 T 8 MeV

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

Powerful Nanosecond Single- Shot Technique for Detection of Illicit Materials and Explosives

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Comments on the possible observation of d-d fusion in sonoluminescence (Reference-31 in Taleyarkhan et al. [2002] 1 )

LAB 4: Gamma-ray coincidence spectrometry (2018)

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

THE PRECURSOR OF "COLD FUSION" PHENOMENON IN DEUTERIUM/ SOLID SYSTEMS

Neutron TOF spectroscopy in a single-shot nanosecond neutron pulsed technique for a disclosure of hidden explosives and fissile materials

NUCLEAR EMISSIONS FROM TITANIUM HYDRIDE/DEUTERIDE INDUCED BY POWERFUL PICOSECOND LASER BEAM

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

Electrochemically induced nuclear fusion of deuterium

EXCESS HEAT AND UNEXPECTED ELEMENTS FROM AQUEOUS ELECTROLYSIS WITH TITANIUM AND PALLADIUM CATHODES

CR-39 TRACK DETECTORS IN COLD FUSION EXPERIMENTS: REVIEW AND PERSPECTIVES. A. S. Roussetski

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

FIG. 1. "Flower-like" configuration of filaments used for modelling. Magnetic field values for this configuration can be described analytically. Induc

Radioactivity. PC1144 Physics IV. 1 Objectives. 2 Equipment List. 3 Theory

THE PRECURSOR OF "COLD FUSION" PHENOMENON IN DEUTERIUM/ SOLID SYSTEMS

Fig.1 Pyrex glass cell

How to Cause Nuclear Reactions at Low Energy and Why Should You Care

DETECTION OF ANOMALOUS ELEMENTS, X-RAY AND EXCESS HEAT INDUCED BY CONTINUOUS DIFFUSION OF DEUTERIUM THROUGH MULTI-LAYER CATHODE (Pd/CaO/Pd)

Absorption and Backscattering ofβrays

EEE4106Z Radiation Interactions & Detection

POSTER EVIDENCE FOR FAST NEUTRON EMISSION DURING SRI S SPAWAR/GALILEO TYPE ELECTROLYSIS EXPERIMENTS #7 AND #5, BASED ON CR-39 TRACK DETECTOR RECORD

EXCESS HEAT PRODUCTION IN Pd/D DURING PERIODIC PULSE DISCHARGE CURRENT IN VARIOUS CONDITIONS

AUTORADIOGRAPHY OF DEUTERATED Ti AND Pd TARGETS FOR SPATIALLY RESOLVED DETECTION OF TRITIUM PRODUCED BY COLD FUSION

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

SPAWAR Systems Center-Pacific Pd:D Co-Deposition Research: Overview of Refereed LENR Publications

Reinterpreting the Results of the Fleischmann and Pons Cold Fusion Experiments

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

Nuclear product ratio for glow discharge in deuterium

Shielded Scintillator for Neutron Characterization

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

Radionuclide Imaging MII Detection of Nuclear Emission

A.DE NINNO, A. FRATTOLILLO, A. RIZZO. ENEA C.R. Frascati,Via E. Fermi 45, Frascati (Rome), Italy E. DEL GIUDICE

SEARCH FOR COHERENT DEUTERON FUSION BY BEAM AND ELECTROLYSIS EXPERIMENTS

on basis of the Geant4 simulations

Alpha-Energies of different sources with Multi Channel Analyzer

Fast Neutron Imaging for SNM Detection

188 L. Jakubowski and M.J. Sadowski temperature. Some examples of the registered X-ray images are shown in Fig.1. Figure 1. X-ray pinhole images from

Neutron emission asymmetries from linearly polarized γ rays on nat Cd, nat Sn, and 181 Ta

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

The 46g BGO bolometer

Large area scintillation detector for dosimetric stand with improved light collection

Louis Baum University of Michigan, REU Student Summer UM Nuclear Sciences Group

JRC Place on dd Month YYYY Event Name 1

CHARGED PARTICLE EMISSIONS AND SURFACE MORPHOLOGY OF THE Pd/PdO:Dx AND THE TiDx TARGETS UNDER AN ELECTRON BEAM EXCITATION

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

CR-39 Results Obtained Using Pd/D Co-deposition. Pamela A. Mosier-Boss Lawrence P.G. Forsley

INTRODUCTION EXPERIMENTAL

SEARCH FOR NUCLEAR PHENOMENA BY THE INTERACTION BETWEEN TITANIUM AND DEUTERIUM

Neutron emission from D 2 gas in magnetic fields under low temperature. Summary. 1:Introduction

RADIATION DETECTION AND MEASUREMENT

RICE UNIVERSITY GAMMA-RAY SPECTRA FROM BE 3 AND N 1^ WITH C 12. Hsin-Min Kuan A THESIS SUBMITTED IN PARTIAL FULFILLMENT OF THE

Time-Resolved Liquid Scintillation Counting

Review of recent experiments carried out on the 1MJ Plasma-Focus PF-1000U device.

Response function measurements of an NE102A organic scintillator using an 241 Am-Be source

Construction and Physics of the Dense Plasma Focus device

Quality Assurance. Purity control. Polycrystalline Ingots

Generation of DD Reactions in a Ferroelectric KD2PO4 Single Crystal During Transition Through Curie Point (T c = 220 K)

Calorimetric Principles and Problems in Pd-D 2 O Electrolysis

PLK VICWOOD K.T. CHONG SIXTH FORM COLLEGE Form Seven AL Physics Radioactivity

Radiation Detection. 15 th Annual OSC Readiness Training Program.

MEASUREMENTS OF PARTICULE EMISSION SPECTRA IN PROTON INDUCED REACTIONS OF INTEREST FOR THE DEVELOPMENT OF ACCELERATOR DRIVEN SYSTEMS

Characteristics of Excess Heat in Pd D 2 O+D 2 SO 4 Electrolytic Cells Measured by Seebeck Envelope Calorimetry

Cross Calibration for using Neutron Activation Analysis with Copper Samples to measure D-T Fusion Yields

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

Absorption and Backscattering of β-rays

ICF Burn-History Measurements Using 17-MeV Fusion Gamma Rays

DETECTORS. I. Charged Particle Detectors

Our Galileo Project March 2007 report

Transcription:

NVESTGATONS OF NEUTRON EMSSON N A COLD FUSON EXPERMENT N PALLAD UM M. Szustakowski, J. Farny, M.!'luniak,. A. Nowak, P. Parys, W. Skrzeczanowski, R. Socha, J. Teter, J. Wolski, J. Wolowski, E. Woryna nstitute of Plasma Physics and Laser Microfusion 00-908 Warsaw, P.O. box 49, Poland 1. NTRODUCTON The experiments dealing with performance of nuclear fusion at room temperature actually create a great sensation and are carried out in various laboratories [1,2}. This interest arises from the results achieved by Fleischmann and Pons, and it r? suts from their paper [1] that there exists a possibility of obtaining an ignition owing to nuclear fusion reactions during "usual" electrochemical process - namely the electrolysis of D 0 with use of the system of Pd Pt electrodes. These fusion reactions of the type of 3HefO.82 MeV) + n(2.45 MeV) D + D-- { T(1.01 MeV) + p(3.02 MeV) are connected with neutron emission. From this reason the measurements of the yield and behaviour of neutron emission give the information about processes of interest. At theppu~ the cold fusion experiments have been conducted from the beginning of April 1989. n the first experiment the reliable evidence of neutron emission was obtained. A number of irregularly repeated neutron pulses of the level of 10 5 per pulse was recorded. The measurements of the neutron emission, in this experiment, were performed with the use of three independent methods employing the 2.5 MeV neutron spectrometer, the scintillation neutron detector as well as the nuclear track detector. Neutron emission had been first recorded after 106 hours of the electrolysis process of D:zO. The correlation between the neutron emission and measured temperature effects has not been observed. The recorded electrode temperature changes were clearly connected with the polarization current density. n the next our experiments, besides diagnostic methodes listed above, the silver activation neutron detectors ~nd the triple coincidence system have been employed. n these experiments a disagreement, between results obtained by means of the nuclear track detectors and other diagnostic systems, appeared. This disagreement will be discused in the next sections. 2. EXPERMENTAL ARRANGEMENT 2.1. Experimental conditions The scheme of the experimental arrangement used in the first experiment is shown in Fig. 1. The glass vessel, in which the electrolysis had been driven, was in cylinder shape 90 mm in diameter and 200 mm in height. The 0.5N NaOD solution in D:zO (99.8% enhancement) as an electrolyte was used. Palladium electrode (a massive cylindrical rod cathode) was 10 md in diameter and 124 mm in height, while the platinum grid of the 35 mm in diameter and 100 mm in height was used as an anode. During the first experiment the palladium electrode temperature was being continuously checked by means of a thermocouple. During the first experiment the current density was changed from 12.5 to 105 ma/cm:2. n the next experiments similsr geometry of electrodes and current densities were employed with one exception in which electrodes in the form of cylinders were used. n the last experiment the solution of 6LiOD in DzO was used as the electrolyte. 299

2.2. Neutron emission measurement A detailed scheme of the neutron measurement systems used scintillation probes in the first experiment is shown in Fig. 2. The probe named NS consisted of the NE-213liquid scintillator and PM tube This probe was connected to the pulses counter via n-~ discriminator, so only pulses from the neutron recoil protons could be counted. The overall efficiency of the NS probe (including measurement geometry) was equal to 0.3%. The probe named consisted of the NE-102A plastic scintillator and PM tube and was connected to the pulses counter via amplitude discriminator only; so this probe was able to count pulses from neutron recoil protons pulses as well as the ~-rays from a reaction n + p_d +!(2.5 MeV). The overall efficiency of the probe was 3.5%, especially because of the plastic scintillator volume which was about six times larger than the liquid one. n this case the neutrons could be slowed down (in the scintillator) to energies at which the n-p reaction became effective. The time gate of NS probe operating was 500 s (each measurement was carried out in a time interval equal to 500 s). The time gates for measurements with use of detector had been chosen to 50, 40 and 20 s, respectively, and for time gates of 40 and 20 s discriminator levels were increased. The plastic nuclear track detectors (CR-39 type) were placed close to the wall of the glass vessel. Before experiments they were calibrated with use of Am-Be neutron source as well as by means of the "plasma focus" discharge, in which the short (about 100 ns) neutron pulses were emitted ~bout 10 9 neutrons in one pulse). The -neutron registration efficiency of these track detectors, 9, determined by these methods amounted to 2x1 0-3 The CR- 39 track detectors were employed in all our experiments. The scheme of neutron measurement system used in the next experiments is shown in Fig. 3. This system consisted of three scintillation probes, N3 and SND with the NE-102A scintillators. Scintillation probes were connected to a triple coincidence system and, parallely, to counters. The probe named SND was connected also to an oscilloscope in order to mea sure the time duration of neutron pulses. Aside from scintillation probes the two silver activation neutron detectors were used in this serie of experiments. The neutron registration efficiency 1] of these detectors was about 10~ to 10-6, respectively. 3. RESULTS AND DSCUSSON All the neutron emission acts registered during the first experiment are presented in Fig. 4. The main feature of the neutron emission in our experiment was its pulsed character. The time duration of the single neutron pulse was much shorter than 1 s. The main part of neutron pulses was recorded only by one (l detector. Only in two cases the neutron pulses were recorded by two detectors (NS and ) simultaneously. This can be attributed to the following facts: - the probe had the overall efficiency about one order of magnitude greater than the NS, - the probe could register the neutron recoil protons and T-ray from the n-p reactions "simultaneously", but the NS probe could not, because it had the n-( discriminator; - if the time duration of the neutrons pulse had been shorter than about 10 ps, then, because of the dead time of the NS probe electronic system, the neutron pulse was not registered and/or it was counted as a background. The absolute neutron yield measured in this experiment, by track detector (5x109) neutrons in compare with neutron yield registered in one pulsed discharge recorded by and/or NS detectors show multiple emission of very short (.1t < 10 ms) neutron pulses. However, our detectors were not optimized for registration of such short and intense neutron radiation pulses, and probably were not able to record a significant part of them. Unfortunately, in our experiments such clear evidence of the pulsed neutron emission was not obtained. Furthermore, the measurements results had obtained by means of neutron spectrometer provided the evidence that there was not any continuous neutron emission. However, in all our experiments the track detector results indicated the total neutron yield on the level of 3x10 8-5x10 9. So there is a serious disagreement between the track detectors results and those obtained by other diagnostics (scintillation probes, silver activation detectors). 300

- Pd Pt-+- NS CR-39 TRACK =-=:.r DETECTOR - --- GLASS VESSEL L.- Pb SHELDS -_----' Fig. 1. The scheme of the experimental arrangement: NS - 2.5 MeV neutron spectrometer, - scintillation neutron counter, electrolyte O.5N NaOD solution in D 2 0 (99.8%) a) b) f22222722 2 2222221 NE213 " " liquid 1 PM Tube Pb shield - 50" 5 0 m~v~z~ze:zaz2;(izr?2z:zz~z~j2ezz2z::ad scintillator?~o.3% n -T DSCRM COUNTER plastic scintillator Fig. 2. Neutron registration systems used in the first experiment: a 2.5 MeV neutron spectrometer, b - scintillation neutron counter, ~ - total registration efficiency (including the geometry of measurements) 301

Time gate 40s Ql g ~ '0 c: '0 U E Ql Ql a. en.-,., ~-- ------+o.= Ul Synchr. pulse Time gate 2ms COUNT..._.::O.::.s:::ci::.:".::.os~co:.:o2:p:::e,---...J Fig. 3. Neutron registration systems used in the next experiments N [counts] 3000 1500 backgrounds 1000 ~ NS 500 NS ~ --- ---- 1 -_11]J _l[d_ JL _ 106 110 135 140 t[h] Fig. 4. Detailed time history of the neutron emission: NS - neutron spectrometer, Ne - neutron counter, --- - background 302

n the near future experiments the authors will try to explain these disagreements which, mayby are connected with the specific time and space charakter of neutron emission. We wish to thank W. Alifanow, H. Wlodarczyk and W. Trocinski for their help and assistance during this experiment. REFEREES 1. M. Fleischmann, S. Pons, Electrochemically induced nuclear fusion of deuterium, Journal of Electroanalytical Chemistry, March,1989. 2. S.E. Jones et al. and J. Rafelski, Observation of cold nuclear fusion in condensed matter, March, 1989. 303