IFS 125HR. Innovation with Integrity. FT-IR Spectrometer for Highest Spectral Resolution FT-IR

Similar documents
CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

EM 27/SUN Series. Innovation with Integrity. For Atmospheric Measurements FT-IR

Which Optistat is right for you?

Near-Infrared Spectroscopy of Nitride Heterostructures EMILY FINAN ADVISOR: DR. OANA MALIS PURDUE UNIVERSITY REU PROGRAM AUGUST 2, 2012

Microscopy Cryostat System

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

Clark Atlanta University Center for Surface Chemistry and Catalysis Instrument Capabilities

Introduction to Fourier Transform Infrared Spectroscopy

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

Introduction to Fourier Transform Infrared Spectroscopy

In-Situ FTIR Spectroscopy and Metrology of a Tungsten CVD Process

FTIR Spectrometer. Basic Theory of Infrared Spectrometer. FTIR Spectrometer. FTIR Accessories

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FT-IR

Fourier Transform Infrared. Spectrometry

FIRST HIGH-RESOLUTION ANALYSIS OF PHOSGENE 35 Cl 2. CO AND 35 Cl 37 ClCO FUNDAMENTALS IN THE CM -1 SPECTRAL REGION

Chem Homework Set Answers

Advanced Spectroscopy Laboratory

Introduction to FT-IR Spectroscopy

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

Thermal And Near infrared Sensor for carbon Observation (TANSO) On board the Greenhouse gases Observing SATellite (GOSAT) Research Announcement

Application Note # AN112 Failure analysis of packaging materials

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Characterization and Calibration of a Fourier Transform Spectroradiometer for Solar UV Irradiance Measurements

Instrumental Analysis: Spectrophotometric Methods

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

Terahertz absorption spectra of highly energetic chemicals

Regular Reflectance and Transmittance Measurements of Transmissive Materials Using a STAR GEM Optical Accessory

Fourier Transform Spectrograph Development Project

LIBSlab ANALYZERS ANALYZERS

REPORT DOCUMENTATION PAGE

novaa 800 D Atomic Absorption Spectrometer

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

ABB Remote Sensing Atmospheric Emitted Radiance Interferometer AERI system overview. Applications

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Abstract. Introduction

Spectroscopic Measurements of Optical Elements For Submillimeter Receivers

requency generation spectroscopy Rahul N

Chapter 3. Infrared Reflectance Spectra of Tholins

DIODE- AND DIFFERENCE-FREQUENCY LASER STUDIES OF ATMOSPHERIC MOLECULES IN THE NEAR- AND MID-INFRARED: H2O, NH3, and NO2

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

Atomic Absorption Spectrometer ZEEnit P series

Optical Frequency Comb Fourier Transform Spectroscopy with Resolution beyond the Path Difference Limit

Vibrational Spectroscopies. C-874 University of Delaware

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Fourier Transform Infrared Spectrometry

IRMS. perspective. Isotope Ratio Mass Spectrometry.

25 Instruments for Optical Spectrometry

C101-E107B UV Shimadzu UV-VIS-NIR Spectrophotometer

EXPERIMENTAL DETERMINATION OF SPECTRAL AND ANGULAR DEPENDENT OPTICAL PROPERTIES OF INSULATING GLASSES

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

Far UV Performance of the LAMBDA 850/950 UV/Vis and UV/Vis/NIR Research Spectrophotometers

Process Analytical Technology Diagnosis, Optimization and Monitoring of Chemical Processes

PERSPECTIVE STABLE ISOTOPE RATIO MS

Quantum Northwest, Inc. Product overview

Environmental Analysis and White Cell applications FTIR Spectroscopy

Mid-IR Methods. Matti Hotokka

Lecture 0. NC State University

Supplementary Figure 1 Comparison of single quantum emitters on two type of substrates:

Accurate Measurement of Transmittance and Reflectance for Engineering Applications

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

Ion Pump Applications

New advances in folded pathlength technology for Process Tunable Diode Laser Absorption Spectrometers (TDLAS)

Absolute Radiance Re-Calibration of FIRST

Probing vacuum ultraviolet energy levels of trivalent gadolinium by two-photon spectroscopy

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Chapter 4 Nadir looking UV measurement. Part-I: Theory and algorithm

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

VASE. J.A. Woollam Co., Inc. Ellipsometry Solutions

Real-time ppb CO 2 Impurity Detection by an Advanced FTIR- UVF System

integrating-sphere-construction-kits

A DIVISION OF ULVAC-PHI. Quantera II. Scanning XPS Microprobe

Widely Tunable and Intense Mid-Infrared PL Emission from Epitaxial Pb(Sr)Te Quantum Dots in a CdTe Matrix

High Flux Solar Simulator and Solar Photo-Thermal Reactor: Characterization and Design

Low Temperature Physics Measurement Systems

Wolter Imaging On Z. Chris Bourdon, Manager Z Imaging and Spectroscopy Julia Vogel, LLNL; Ming Wu, SNL ICF Diagnostics Workshop, October 5 th 2015

Experiment 24: Spectroscopy

Supplemental material for Bound electron nonlinearity beyond the ionization threshold

Analytical Spectroscopy Review

Abstract... I. Acknowledgements... III. Table of Content... V. List of Tables... VIII. List of Figures... IX

INTRODUCTION Strained Silicon Monochromator Magnesium Housing Windows for Monochromator Shutter and Collimator Fission Detector HOPG Monochromator

Two-electron systems

LASERS. Dr D. Arun Kumar Assistant Professor Department of Physical Sciences Bannari Amman Institute of Technology Sathyamangalam

Investigation of Water Fragments

Emission Limb sounders (MIPAS)

Magnetic Property Measurement System

Extrel is widely respected for the quality of mass spectrometer systems that are

LDLS Laser-Driven Light Source

Beetle UHV VT AFM / STM

Low Vibration Cryogenic Equipment

Analysis of Gamma butyrolactone for registration according REACH. Report no. JK 75/17

A TES Bolometer for THz FT-Spectroscopy

Fabry-Perot Interferometer for atmospheric monitoring useful for EAS detection E.Fokitis 1, K. Patrinos 1, Z. Nikitaki 1

m m lighter 'atom' dominates 2 INFRARED SPECTROSCOPY All modes of vibrations are not IR active.

Upgrade of the FLASH beamlines New diagnostic and beam transport tools

Scanning Kelvin Probe Systems

SPECTROPHOTOMETERS. Visible and UV-Visible

Taking fingerprints of stars, galaxies, and interstellar gas clouds

FLS980 Series Reference Guide

IR spectral characterization of customer blackbody sources: first calibration results

Transcription:

IFS 125HR FT-IR Spectrometer for Highest Spectral Resolution Innovation with Integrity FT-IR

The Benchmark of Ultra-High Resolution Research FT-IR Spectroscopy Picture Source: HZB Three decades ago, Bruker started to set the pace for achieving the highest spectral resolution in FT-IR spectroscopy. The famous IFS 120HR was universally recognized as the winner. The IFS 125HR is the proud successor of the IFS 120HR offering further spectral resolution enhancement and increased measurement sensitivity over a wide spectral range from 5 cm -1 in the far-ir/terahertz up to 50,000 cm -1 in the UV.

IFS 125HR System Design The need for High Resolution Whether you are studying the composition of the stratosphere on top of Germany s highest mountain, the 2,964 meter Zugspitze, or the structure of gaseous molecules in your own research laboratory, you need the highest sensitivity at the highest resolution possible. Studies of physical-chemical primary processes require very high spectral resolution to derive the true molecular quantum motion from the absorption spectra. In addition, high resolution FT-IR spectroscopy is ideal for investigating changes in stratospheric gas concentrations due to its sensitivity and selectivity. Highest Resolution Line Width 0,00067 cm -1 Demonstration of the achievable line width at half height of 0.00067 cm -1 using the CO pure rotational absorption in the far IR by using a 20 cm path length gas cell, 50 co-added scans and a liquid He cooled bolometer detector. Superior Instrument Features Outstanding resolution across the entire spectral range that demonstrates a resolved line width better than 0.0007 cm -1 Optical path difference up to 11 m; resolving power of better than 10 6 Wavenumber precision of 10-7 relative (corresponds to the stability of the reference HeNe laser) Highest measurement sensitivity and instrument stability from 5 cm -1 in the far-ir/thz up to 50,000 cm -1 in the UV Permanently aligned retro reflector interferometer Double-sided interferogram acquisition up to 50cm optical path difference (OPD) Vacuum optics bench evacuable to < 0.02 hpa Vacuum level in the 10-4 hpa range achievable by utilizing a turbo molecular pump Modular optics design with two sample channels Compact version without sample compartment for emission or solar absorption measurements Up to three internal sources and six permanently installed detectors Easy and reproducible detector and beamsplitter exchange Parallel 2-channel 24-bit data acquisition High Resolution Line Shape Accuracy HBr absorption line measured (red) in the MIR spectral range at 0.0035 cm -1 resolution, showing the very close agreement with the calculated (blue) line shape. The residual difference spectrum (red bottom) was ca. 15 times enlarged in the transmittance scale. Advanced Electronics Technology The IFS 125HR is a fully digital FT-IR spectrometer. Its modular design provides the highest flexibility and at the same time the highest instrument performance. The data acquisition is based on free running deltasigma ADCs with true 24-bit dynamic range, which are integrated into the detector preamplifier electronics. The advanced DigiTect TM technology prevents external signal disturbance and guarantees the highest signal-tonoise ratio. Dual channel data acquisition is an integral part of the new electronics and can easily be set up through software control. AC- & DC-coupled signals of the same detector can be achieved with no special hardware required. Utilizing two detectors and a dichroic beamsplitter or a sandwich detector (e.g. InSb/MCT), parallel data acquisition in two different spectral ranges is possible.

The IFS 125HR Optics Bench Double Beam Sample Compartment There are two large chambers with focused beams which accommodate a wide variety of sampling accessories including long path gas cells and cryostats. To enhance flexibility, each sample chamber can be equipped with an additional exit port. Flaps isolate the sample compartment to preserve vacuum in the rest of the optics during sample change or accessory installation. At the sample position, a one-to-one image of the input aperture is provided. The Detector Compartment The detector compartment can house up to four internal and two external detectors. All six detector positions are accessible by beams from either sample chamber and detector selection is under computer control. Up to four liquid nitrogen cooled or room temperature detectors with Bruker s DigiTectTM technology can be mounted internally. The external positions provide room for large liquid helium cooled detectors such as far-ir bolometers or special high sensitivity mid-ir detectors such as Si:B or Ge:Au. For emission studies, a separate detector chamber may be mounted at the collimated beam exit port of the interferometer to maximize energy throughput in the NIR/VIS/UV range. The system includes a closed-loop coolant system for the sources and a vacuum pump which evacuates the bench to a level of <0.02 hpa. Alternatively, the entire optics bench may be purged with dry, clean air or nitrogen. A much lower vacuum level in the 10-4 hpa range can be achieved by connecting a turbo molecular pump to an optional large flange below the scanner chamber. 9-Chamber scanner arm with high precision metal tubes 4 Detector Chamber

1 Scanner drive, gear, steel pulling wire and the two supporting metal tubes of the interferometer scanner 2 Hybrid retro reflector interferometer scanner showing the electromagnetic fine tuning drive and scanning mirror 3 View into the interferometer compartment showing beamsplitter, optics and scanning cube corner mirror 4 View into the detector compartment showing the opto-mechanical DigiTectTM detector adaptations together with the computer controlled moveable mirrors for automatic selection of up to 4 internal room or liquid N2 temperature detectors and for up to 2 external liquid He cooled detectors Scanner Drive Source Options Hybrid Scanner The source compartment of the IFS 125HR can accommodate three water-cooled, computer-selected sources. In addition, there is a computer-selectable port for an ultra-violet source or external emission experiments. The source beam exits at a focus to the interferometer compartment. An optional large source chamber provides more flexibility with up to 3 external inputs. Solar light for atmospheric studies is typically fed into the parallel input port of this chamber. 1 The Interferometer The permanently aligned interferometer has a 30 angle-of-incidence. The narrow angle-of-incidence makes more effective use of the beamsplitter in addition to reducing beam polarization effects. The beam is split to the fixed and moving cube-corner retro reflectors of the modified Michelson interferometer. The moving mirror is translated on a hybrid bearing whose design ensures beam integrity over the extremely long optical path difference, which can be up to 11 meters. 2 3 Interferometer

IFS 125HR Atmospheric Pollutant Analysis Using the Sun as the IR source Atmospheric CO 2 has rapidly increased since the industrial revolution. High resolution FT-IR spectroscopy is ideal for investigating changes in stratospheric gas concentrations due to its sensitivity and selectivity. The sun serves as the infrared source and the composite optical density due to all absorbers along the optical path to the spectrometer is measured at a given wavelength. Areas of Applications Atmospheric Research Stratospheric trace gas analysis Absolute line strength and band shape of atmospheric gases Radiative transfer through the atmosphere Physical Chemistry Ro-vibrational spectroscopy Determination of molecular dynamics Structural analysis of small molecules Spectroscopy of molecular crystals at low temperatures Matrix isolation studies Solid State Physics Single crystal impurities at low temperature Magneto optical splitting Terahertz (THz) high resolution Compact IFS 125HR (w/o sample compartment) in a 20 freight container, as used for atmospheric measurements. Courtesy of Dr. D. Feist, MPI for Biogeochemistry, Jena Careful analysis of the lineshape even allows a concentration profile versus altitude to be obtained. Like the famous Jungfraujoch Observatory in Switzerland, many high altitude research centers around the globe house high resolution Bruker FT-IR spectrometers, for field emission measurements since the 1980s. Besides additional instrument features, the very high accuracy of the instrument line shape and the outstanding wavelength precision are the major reasons that new reference spectra of the HITRAN and IUPAC data collection are measured using the IFS 125HR. Atmospheric Absorption Spectrum Typical solar absorption spectrum, showing some atmospheric constituents. The special line shape - with a broad base and a narrow tip - allows retrieving information about the vertical distribution of the species. Research Applications IFS 125HR s wide range of internal and external accessories provides any solutions needed for the most demanding research studies. Dedicated long path gas cells and low temperature cryostats provide unlimited research possibilities. The multiple input ports allow dedicated emission applications and coupling with external coherent lasers or very brilliant radiation sources for example from electron synchrotrons or free electron lasers. High magnetic field cryostats, ultra high vacuum (UHV) chambers for in-situ chemical vapour deposition (CVD) or molecular beam epitaxy (MBE) studies, and reaction gas cells can be connected to the instrument utilizing the multiple exit beams. Multipath Gas Cell

IFS 125HR Research Applications NIR High Resolution Gas Phase Emission Measurements Even in the visible and ultraviolet (UV) short wavelength spectral ranges, the Fourier transform advantages of wavelength precision and high resolution are present. Therefore Bruker has designed the IFS 125HR for upgrade into this interesting spectral range, where electronic transitions can be studied which are not accessible in the IR. Data compatibility and upgradability make the IFS 125HR an ideal measurement tool for the short wavelength range as well. UV High Resolution Emission Overtone CO 2 absorption band head measured with 20 m path length, 18 hpa pressure, at 0.01 cm -1 spectral resolution in the near IR spectral range using a LN 2 cooled InSb detector, CaF 2 beam splitter and tungsten source. Solid State Cryogenic Analysis Highest resolution data are not only interesting for gas phase samples, but also for single crystalline materials at low temperature. By the adaptation of liquid He/N 2 or cryogenic liquid free, low vibration pulse tube cryostats, sample temperatures of less than 10 K are achievable. Common applications are the quality control of semiconductor material like GaAs. In addition, the external adaptation of cryo-magnetostat systems allow low temperature measurements in the mid and far IR spectral ranges at high magnetic fields up to 11 Tesla. B(As) in GaAs Emission spectrum from a Pt hollow cathode lamp measured at a spectral resolution of 0.11 cm -1 using a solar blind Photo Multiplier Tube (PMT) detector and 2,500 scans. Connection to e-synchrotron Source New high resolution application possibilities are feasible by the use of synchrotron IR-radiation. In particular, due to its high brilliance and its pulsed structure, fast photoreaction kinetics might be applicable in pump-and-probe experiments, even at high resolution. Low temperature measurement of a semi-isolating GaAs single crystal sample at <10 K and 0.01 cm -1 spectral resolution showing the Boron impurity at the As site. A wide-band liquid N 2 cooled MCT and 350 scans have been used for data aquisition. Canadian Light Source installation site with the IFS 125HR optics bench and the Ultra High Vacuum (UHV) tubes guiding the IR synchrotron radiation to the spectrometer input port.

Optical Components & Accessories Spectral ranges Achievable Resolution Sources Beamsplitters Detectors Window Materials Accessories FIR/THz 5 cm -1-650 cm -1 (2 mm - 15 µm) Mid IR 500 cm -1-5,000 cm -1 (20 µm - 2 µm) Near IR 4,000 cm -1-12,500 cm -1 (2.5 µm - 800 nm) Visible/UV 12,500 cm -1-50,000 cm -1 (800 nm - 200 nm) <0.0007 cm -1 <0.001-0.004 cm -1 <0.004-0.012 cm -1 <0.012-0.05 cm -1 Water cooled Hg-Arc and Globar Multilayer and Mylar TM foils of different thicknesses RT DTGS/PE, LHe cooled bolometer, Si:B photo diode Si, Ge, PE, TPX, CsI, KBr, KRS-5 Internal direct path and long path gas cells, LHe and LN 2 cryostats, specular reflectance units, external Cryo- Magnetostats, external single and multi reflection long path gas cells, external input ports Water cooled Globar and Tungsten Water cooled Tungsten Water cooled Tungsten and air cooled Xe lamp MIR/KBr NIR/CaF 2 VIS/Quartz and UV/Quartz Broad, medium and narrow band LN 2 cooled MCT and InSb (with and w/o cold filter), sandwich InSb/MCT Si, Ge, ZnSe, CsI, KBr, KRS-5, CaF 2, Sapphire, Infrasil Quartz Internal direct path and long path gas cells, LHe and LN 2 cryostats, specular reflectance units, external Cryo- Magnetostats, external single and multi reflection long path gas cells, external input ports RT InGaAs, LN 2 cooled InSb (with and w/o cold filter) Si, ZnSe, KBr, KRS-5, CaF2, Sapphire, Infrasil Quartz Internal direct path and long path gas cells, LHe and LN 2 cryostats, specular reflectance units, external single and multi reflection long path gas cells, external input ports Si-diode, GaP-diode, Photo Multiplier (PM) tube CaF 2, Sapphire, Infrasil Quartz, UV/Quartz Internal direct path and long path gas cells,lhe and LN 2 cryostats, specular reflectance units, external single and multi reflection long path gas cells, external input ports For more details regarding the IFS 125HR instrument specifications, its optical components and the available accessories please contact your local Bruker Optics office. Application Support Whether it is going to be on a mountain top or below sea level, we realize that the IFS 125HR requires attention to detail, when it comes to installation and support. Bruker Optics is staffed by expert scientists and engineers that have an in-depth knowledge of instrumentation and applications. Our product specialists are available to help you with method development either remotely or in your lab. Service Support Bruker Optics spectrometers are designed to provide years of dependable trouble-free operation. Should a problem occur, a network of Bruker companies and representatives throughout the world are ready to respond promptly to your needs. Professional installations and a high standard of post-delivery service are commitments Bruker Optics makes to each of its customers. Remote diagnostics in addition to a variety of service contract packages are available for comprehensive support. Technologies used are protected by one or more of the following patents: US 7034944; US 5923422; DE 19704598 Bruker Optics is ISO 9001 certified. Laser class 2 www.bruker.com/optics Bruker Optics Inc. Bruker Optik GmbH Bruker Hong Kong Ltd. Billerica, MA USA Phone +1 (978) 439-9899 Fax +1 (978) 663-9177 info@brukeroptics.com Ettlingen Germany Phone +49 (7243) 504-2000 Fax +49 (7243) 504-2050 info@brukeroptics.de Hong Kong Phone +852 2796-6100 Fax +852 2796-6109 hk@brukeroptics.com.hk Bruker Optics is continually improving its products and reserves the right to change specifications without notice. 2014 Bruker Optics BOPT-4000493-02