Accurate Mass Analysis of Hydraulic Fracturing Waters

Similar documents
Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Agilent All Ions MS/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Application Note. Authors. Abstract. Introduction. Environmental

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Application Note. Edgar Naegele. Abstract

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Agilent ESI and APCI sources: for polar to non-polar compounds

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Application Note. Abstract. Authors. Environmental

GC-APCI IMS of Diesel

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Computer-assisted analysis of complex natural product extracts

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

ANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide

Acknowledgement: 4F-PBP (C14H18FNO) T: +386 (0) E: Vodovodna Ljubljana SLOVENIJA

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

LC-MS Based Metabolomics

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Application Note. Edgar Naegele. Abstract

ANALYTICAL REPORT 1 1P-LSD (C23H29N3O2) N,N-diethyl-7-methyl-4-propanoyl-6,6a,8,9-tetrahydroindolo[4,3-fg]quinoline-9-

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

ANALYTICAL REPORT 1. 4-Me-TMP (C15H21NO2) Remark other NPS detected: none. sample contains some impurities (benzeneacetic acid + others)

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

The new Water Screening PCDL

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Technical Note. Introduction

Agilent G3212 GC-APCI Source

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Characterization of Steroidal Saponins From Two Dioscorea Species Using Liquid Chromatography and the Agilent 6500 Series Accurate-Mass Q-TOF LC/MS

Construction and Use of API Single- Quadrupole MS Spectral Libraries.

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

C Glucose Qualitative Flux Analysis in HepG2 cells

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Analysis of Polar Metabolites using Mass Spectrometry

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

MassHunter TOF/QTOF Users Meeting

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

QTOF Training Manual

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Multiresidue Analysis of 100 Pesticides in Food Samples by LC/Triple Quadrupole Mass Spectrometry Application

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

TANDEM MASS SPECTROSCOPY

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Finding NDMA Precursors Using Accurate Mass Tools with an Agilent 6540 Q-TOF LC/MS

Mass Spectrometry in MCAL

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Journal of Chromatography A, 1067 (2005) Pesticide Residue Research Group, University of Almería, Almería, Spain

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Agilent Standard Operating Procedure

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Introduction to GC/MS

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Finnigan LCQ Advantage MAX

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Transcription:

Application Note Environmental Accurate Mass Analysis of Hydraulic Fracturing Waters Using the Kendrick mass defect with the Agilent LC/Q-TOF MS Authors E. Michael Thurman and Imma Ferrer Department of Environmental Engineering, University of Colorado, Boulder, CO 839 Jerry A. Zweigenbaum Agilent Technologies, Inc. Abstract To detect a set of polypropylene surfactants that may be used as clay stabilizers, scale inhibitors, or surfactants, water samples from hydraulic fracturing were analyzed using a combination of UHPLC and Q-TOF-MS. Because of their structure, with the accurate mass measurement of the Q-TOF, a Kendrick mass defect tool was developed and used to help separate the mixture of polypropylene surfactants and their adducts, present in many hydraulic fracturing samples. This Application Note discusses the chromatography associated with the polypropylene glycol surfactants, in regards to the multiple isomers that form. The polypropylene-glycol surfactants (PPGs) make excellent tracers of hydraulic fracturing wastewaters, since they are not commonly detected in surface and groundwater samples. PPG surfactants have been detected in approximately 2 samples from Colorado, North Dakota, Oklahoma, and Texas.

Introduction Hydraulic fracturing, sometimes called fracking, is the process of removing gas and oil from clay-rich deposits that were previously unproductive because of the low yield of hydrocarbons. The combination of horizontal drilling at great depth (7, to 1, feet below the surface), and the use of a mixture of water, proppants (sand), surfactants, biocides, and other chemicals, has enabled the economic recovery of both gas and oil. This process of hydraulic fracturing has revolutionized gas and oil recovery during the last 1 years. It has created a booming oil business in the western United States, especially in Colorado, Texas, and the Dakotas. One of the concerns with hydraulic fracturing is the large volumes of water that are needed per well, approximately 3 5 million gallons, depending on the depth of the well. Less than half of this water returns to the surface where either recycling or disposal is required. For proper handling, it is critical to know the constituents of this wastewater, organic and inorganic. Thus, there is a need for rapid and accurate measurement of the chemicals in these waters. This Application Note used a combination of ultrahigh performance liquid chromatography (UHPLC) followed by quadrupole time-of-flight mass spectrometry (Q-TOF-MS) to separate and identify many of the chemicals present in the wastewaters. One of the key tools for this process is the Kendrick mass defect. This tool takes advantage of the fact that the polymeric chemicals used in the proppant mixture are based on a polyethylene or polypropylene glycol structure. Various functional groups are added to the end of the surfactants to give the proper hydrophilic/hydrophobic balance needed to move both oil and gas through a sand and water mixture. This Application Note shows how the authors applied LC/Q-TOF-MS with the Kendrick mass defect tool to ascertain the structure of the polypropylene surfactants and their adducts. This Application Note is useful to those who analyze hydraulic fracturing wastewaters, and to those involved with these types of surfactant mixtures in general. Experimental Instruments The Agilent 129 Infinity II LC was used to separate the surfactant mixtures, and was coupled to an Agilent 6545 Q-TOF LC/MS equipped with electrospray Jet Stream technology. Table 1 shows the instrument conditions. Table 1. LC and Q-TOF-MS conditions and analysis parameters. Column Column temperature 25 C Injection volume 1 µl Mobile phase Linear gradient Flow rate Postrun Ion mode Drying gas LC run conditions Sample collection Agilent ZORBAX Eclipse XDB-C8, 4.6 15 mm, 3.5 mm A).1 % Formic acid in water v/v B) Acetonitrile 1 %B for 5 minutes, 1 %B to 1 %B over 25 minutes.6 ml/min 12 minutes Q-TOF MS conditions ESI positive 1 L/min Gas temperature 325 C Nebulizer gas 45 psig Sheath gas 11 L/min at 35 C Capillary voltage Nozzle voltage Fragmentor voltage Skimmer voltage Octopole RF 4, V 1, V 19 V 45 V 75 V Mass range m/z 5 1, Detector rate 2 GHz Resolving power 3, at m/z 1,522 Wastewater samples were collected from various locations in the western United States, including Colorado, North Dakota, Oklahoma, and Texas. To obtain a representative set of both produced and flowback samples, the samples required the cooperation and assistance of oil companies and their partners. This was accomplished with the help of the Environmental Defense Fund and their partners in industry. The samples were collected on-site from oil/water/gas separators. Samples were stored at 4 C for up to one month before analysis. 2

Data analysis The data were processed with Agilent MassHunter software. Optimum mass accuracy was obtained with an automated calibrant delivery system using a low flow of a calibrating solution (calibrant solution A, Agilent Technologies, Inc.) that contained the internal reference masses purine m/z 121.59 and HP-921 m/z 922.98. Results and discussion UHPLC/Q-TOF-MS analysis of hydraulic fracturing waters Figure 1 shows the positive ion electrospray total ion current (TIC) chromatogram for the analysis of a produced water sample from Colorado. This chromatogram shows several sharp narrow peaks in the PEG region as well as peaks that are rounded but symmetrical in the PPG region (Figure 1). Figure 1 shows two distinct mass zones, the earlier region is a PEG region, on which we have published several journal articles 1,2. The PEG region has mass differences of 44.262 mass units on average (retention time of 9 12.5 minutes). The second region of the chromatogram has mass differences of 58.419 ±.2 mass units (retention time of 12.5 19 minutes). This second region suggests a polypropylene unit (CH 2 CH(CH 3 )-O) or PPG region, rather than a polyethylene unit (PEG region). Because of the repeatable unit of 58.419, it is possible to apply the Kendrick mass scale to help identify the compound of interest, as well as its polymeric series and that of its adducts. 1 6 4. A 3.6 3.2 2.8 2.4 2. 1.6 1.2 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3 Acquisition time (min) 1 7 B 1.4 Zoom of PPG region 1.2 1..6 PPG-EO4.2 11.8 PPG-EO9 12.2 12.6 13. 13.4 13.8 14.2 14.6 15. 15.4 15.8 16.2 16.6 17. 17.4 17.8 18.2 18.6 19. 19.4 19.8 Acquisition time (min) Figure 1. UHPLC/Q-TOF-MS with the TIC of a produced water sample, JR-5, from a recently fractured well that shows an area of the chromatogram with a mass separation of 58 mass units from 12 to 19 minutes. The zoomed area is shown in B. 3

Kendrick mass scale Table 2 shows the result of applying the Kendrick mass scale to a series of masses in a produced water sample from hydraulic fracturing, sample JR-5 from Colorado. To understand a series of hydrocarbons that differed in mass by a methylene group, CH 2, Kendrick used a filtering technique, which is named after him 3. The Kendrick mass scale has been applied to other series, but only recently to PEGs 1 and PPGs 2. The application of the Kendrick mass scale first involves the determination of the Kendrick mass scaling factor. This factor is determined by dividing the nominal mass of the repeating polypropylene glycol unit (58 mass units) by the calculated exact mass of the same unit (58.4186481) for a scaling factor of.999278714. When this scaling factor is multiplied by the measured accurate mass, the resulting mass is called the Kendrick mass. The Kendrick mass defect is defined as the Kendrick nominal mass minus the Kendrick accurate mass, which for PPG PO4 is 273 272.971 =.29. All PPGs in Table 2 have the same Kendrick mass defect within an error of.1. The concept of the Kendrick mass is that if two compounds have the same repeating chemical structure, that is, (CH 2 (CH 3 )CH-O), there will be an addition of the exact mass of that group, that is, 58.419 mass units, to each new compound in the chromatogram. Thus, when the scaling factor is multiplied by the measured masses, all ions that differ by the CH 2 (CH 3 )CH-O group will have the same Kendrick mass defect. Thus, it is only necessary to obtain the correct formula and structure for one of the unknown polypropylene glycols. All other unknown polypropylene glycols can be calculated as either one unit longer or shorter depending on the gain or loss of the 58.419 unit. MS/MS Identification of PPG surfactants Once the Kendrick series is identified, an ion is selected for MS/MS analysis. Figure 2 shows a typical mass spectrum for the produced water sample, JR-5, with three prominent adducts for the suspected PPG-PO7. The adducts are proton, ammonium, and sodium. Table 2. Kendrick mass for a suite of polypropylene glycol surfactants from PPG-EO4 to PPG-EO9, with an average mass difference of 58.419 ±.2 mass units, from a produced water sample (JR-5) from hydraulic fracturing located in Colorado. The ion measured is the sodiated adduct. Retention time (min) Ion measured m/z Kendrick mass Kendrick mass defect Ion adduct 12.9 273.1676 272.971.29 Na+PPG-PO4 14.4 331.294 33.971.29 Na+PPG-PO5 15.6 389.2515 388.971.29 Na+PPG-PO6 16.4 447.2935 446.971.29 Na+PPG-PO7 17.6 55.3349 54.97.3 Na+PPG-PO8 18.8 563.3764 562.97.3 Na+PPG-PO9 1 7 1..9.7.6.5.3.2.1 H + adduct 425.3116 Based on matching the retention times of the adducts, either the proton or the ammonium adduct is then chosen for MS/MS analysis. Figure 3 shows the fragmentation pattern for the PPG PO7 standard, which matched the fragmentation of the putative PPG-PO7 sample. NH 4 + adduct 442.3387 Na + adduct 447.2935 416 418 42 422 424 426 428 43 432 434 466 438 44 442 444 446 448 45 452 454 456 458 46 Mass-to-charge (m/z) Figure 2. The MS spectrum of a putative PPG-PO7 with the proton, ammonium, and sodium adducts shown. 4

The fragmentation first involves the loss of water from the protonated PPG-PO7 (Figure 3). Then, the protonated molecule proceeds to undergo the neutral losses of 58.419 ±.2 in a zipper-like fashion until the last propylene group with a mass of m/z 59.495. The loss of water indicates that the surfactant ends with an OH. This is also confirmed by multiplying the number of repeating units by its mass (58) and subtracting the result from the molecular mass, in this case 18. This is one of the simplest fragmentation patterns one will see in the identification of surfactants. If the surfactant ended with another moiety, this could be determined by the remaining fraction and the accurate mass measurement. Now that we have confirmation of the PPG-PO7, we can extend the Kendrick mass defect to all of the compounds in Table 2, from PPG-PO4 to PPG-PO9. This is the power of using the Kendrick mass defect with closely related surfactant mixtures. Another interesting feature of the polypropylene glycol surfactants is their chromatography, which is shown in the zoomed part of Figure 1. Notice that the peaks are approximately one minute wide. This widening of the peaks is caused by the presence of many isomers for the PPG surfactant mixture 2. PEGs have only one isomer, and give sharp peaks of approximately 12 seconds wide. In contrast, the PPGs have more than 1 tetramers for PPG-PO4, which increases exponentially with each new addition of 58 mass units. Notice the partial separation of the tetramers for the PPG-PO4 in the zoomed portion of Figure 1. This effect is caused by the fact that the PPG molecule is asymmetrical. Thus, the result is that there are 1s of possible isomers by PPG-PO9, with different retention times but the same accurate mass. These isomers 1 4 2. 1.8 1.6 1.4 1.2 1..6.2 4 59.495 58.415 99.83 117.91 6 8 1 12 14 16 18 2 22 24 26 28 3 32 34 36 38 4 42 44 46 48 5 Mass-to-charge (m/z) Figure 3. MS/MS analysis of PPG-PO7. lead to the broadening of peaks from 1 12 seconds per compound to over one minute wide. This characteristic shape of the longer-chain PPGs was found in nearly all hydraulic fracturing water samples (that is, ~2 samples) that we have analyzed and published 2. Thus, PPGs are good indicators of hydraulic fracturing wastewater, since they are not typically found in water samples. An accurate mass database of PPG compounds Once the PPGs are identified (Table 2), it is possible to carry out the process of PPG identification automatically on new samples using a Personal Compound Database (PCD), an accurate mass database inside the MassHunter Software. The database is constructed using a program called the Personal Compound Database Library (PCDL). The formula, name, and structure are entered into the library. Different settings are used to search the unknown samples, such as accurate mass and retention time windows. This process can be automated to rapidly identify PPGs in unknown wastewater samples from hydraulic fracturing using either a PCD or 58.418 58.419 58.419 58.417 58.392 175.1328 193.1426 157.1221 233.1747 291.2166 251.1849 349.2583 OH a PCDL. We used a PCD only (no spectra) on approximately 2 samples from Texas, North Dakota, Oklahoma, and Colorado with detections of the PPGs in most of the samples. This work was carried out with cooperation from the Environmental Defense Fund. Conclusions C 3 H 6 O Exact mass: 58.419 H 2 18.131 47.2975 425.316 The 129 Infinity II LC and 6545 LC/Q-TOF-MS enabled the characterization of polypropylene glycol surfactants from hydraulic fracturing water samples. Applying the Kendrick mass defect to the accurate masses of these PPGs facilitates their rapid identification using MassHunter software. A PCDL can then be constructed and used to identify these compounds in wastewater samples from hydraulic fracturing. Finally, polypropylene surfactants make excellent tracers of hydraulic fracturing wastewaters, since they are not commonly detected in surface and groundwater samples, and are commonly found in hydraulic fracturing wastewaters. 5

References 1. Thurman, E. M.; et al. Analysis of hydraulic fracturing flowback and produced waters using accurate mass: identification of ethoxylated surfactants. Analytical Chemistry 214, 86, 9653 9661. 2. Thurman, E. M.; et al. Identification of polypropylene glycols and polyethylene glycol carboxylates in flowback and produced water from hydraulic fracturing. Journal of Hazardous Materials 217, 323, 11 17. 3. E. Kendrick. A mass scale based on CH 2 = 14. for high resolution mass spectrometry of organic compounds. Analytical Chemistry 1963, 35, 2146 2154. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc. 219 Printed in the USA, January 16, 219 5994-44EN