SafeN130 Movable Apparatus for Radioactive Noble Gases Removing
Introduction The movable apparatus for removing radioactive noble gases which is developed from DS SCIENCE INC (Model SafeN130), is a prevention device for the worker's radioactive exposure and the environment pollution by removing the existing radioactive noble gases in the inside air of high pollution area(s/g, PZR etc.) in the building of nuclear power plant during OverHaul(O/H) period. Features Removing the noble gases up to 99% (Xe, Kr, Ar etc.) The bigger removing capacity than the existing removing capacity. about 28times(2.5CFM 70CFM) Movable compact size Easy to use (Convenient Assemble and Disassemble) Moving by 2 person. When the temperature is 4 ~90, the humidity is 10%~99% and the inhaling rate is Developed by Original Korea technology 0.05m 3 /min~10m 3 /min of the inhaling air, the maximum removing rate of this device is following, the decontamination factor (DF, the valuation of output value from input) is in less then 10E+04±100 purification ability, it can impound and remove up to 99% until 100Ci radioactive capacity of all gases. Patent application : Korea, China, UAE 2 3
1st moisture removing device inside CO 2 removing trap Noble gases removing trap Blower inside Movable supplying device for LN 2 2nd moisture removing trap Data Loger LN 2 Storage box Pressure dispersion device 4 5
Test result The analysis test at the former section of the first noble gases removing device - Confirming supplying the Xenon gases in to the trap by supplying variety concentration Xenon(Xe) (680ppm, 455ppm, 240ppm, 87ppm) The analysis test at the rear section of the second noble gases removing trap - Confirming detecting Xenon(Xe) in the gas which is passing first and second noble gases removing trap. As blow table, Xenon(Xe) is not detected. (Total test period : 22hours) The test result, confirming that Xenon gas is absorbed by noble gas removing device and after increasing temperature, the gas is exhausted. (We can confirm the noble gas device absorb the Xenon(Xe)) SafeN130 Specifications Ⅰ. Radioactive noble gases removing device Ⅱ. Supplement device 1. 1st moisture removing device Dimension (mm) : 500(W) x 840(H) x 800(D) Refrigerant : R-22 Weight : About 50kg Power : 220V, 60Hz, 11.5A Condensation exhausting method : Continually natural draining 2. Main instrument 1) 2nd moisture removing trap and CO 2 removing trap Dimension(mm) : 800(W) x Ø165(R) Opening and shutting device : Manual handle Clamp Band : STS 304 Gasket : Silicon Temperature sensor for measuring exothermic temperature of absorbent : Pt-100 Measuring range for Temperature Humidity sensor : TH300(0~100% RH, -40 ~+180 ) Measuring range for CO 2 concentration sensor : 0~5,000ppm 2) Radioactive noble gases removing trap Dimension(mm) : 500(W) x 500(H) x Ø165(R) Opening and shutting device : Manual handle Clamp Band : STS 304 Gasket : Silicon Temperature sensor for measuring cooling temperature of absorbent : Pt-100(-200 ~+400 ) 3) LN 2 Storage box Dimension(mm) : 765(W) x 360(H) x 350(D) Inside capacity : 46 Liters Material of Inside/outside : A.B.S/PR Material of inside insulation : A kind of Polymer insulation 4) Total weight(full) : About 120kg 3. Blower Dimension(mm) : 500(W) x 840(H) x 800(D) Maximum flow rate : 1,560m 3 /hr RPM : 3,410rpm Maximum inhaling rate : 210m 3 /hr(3.5m 3 /min) Flow rate : 2m 3 /min Weight : About 40kg 1. Movable supplying device for liquid nitrogen Dimension(mm) : 643(H) x Ø480(R) Static evaporation rate : < 0.5 Liters/day Filling flow rate : Dripping up to 0.1 Liter/min, depending on application level Max. working pressure : < 300 mbar Storage container volume : 50 Liters Weight(empty) : 13kg Power consumption : avg. 10W, during pumping 50W Power : 115/230V AC with supplied power supply or 12V AC/DC Signal : RS232 for on/off Alarm : On 2. Pressure dispersion device 1) Main-body Dimension(mm) : 980(H) x Ø650(R), 6T Material : Stainless steel 304, etc. Weight : About 80kg Connection Port : Flexible metal horse connection port 24ea, Pressure gauge connection port, ball valve connection port(condensation drain) 2) Pressure gauge Accuracy : ±1.5% of full scale Scale range : 0~10Mpa(0~101.97kgf/cm 2 ) Operating temperature range : -20 ~+65 Connection part : Ball valve 1/2" (Welding on the top of pressure dispersion device) Composition for movable noble gases removing instrument 1st moisture removing device 2nd moisture removing device CO 2 removing trap Radioactive noble gas removing trap Air quick cooling device Liquid nitrogen tank Transportation device for moisture/co 2 removing trap Transportation device for radioactive noble gases removing trap Pressure dispersion device Temperature/Humidity measuring sensor CO 2 measuring sensor Data loger Movable auto supplying device for liquid nitrogen Computer system Manual 3ea 1set OPTIONS KIT(1 DAY: needed 3ea. /8hrs) - 2nd moisture removing trap - CO 2 removing trap - Radioactive noble gases removing trap 4ea 6 7
SafeN130 Movable Apparatus for Radioactive Noble Gases Removing DS SCIENCE INC., have developed movable radioactive noble gases removing instrument for efficient removing noble gases in the radioactive gases waste by analysis technology which is accumulated for many years. DS SCIENCE INC's movable radioactive noble gases removing instrument(safen130) is designed by compact size for moving it through small personnel, and it is designed to maximize the user convenience by easy assembling and disassembling without complex devices. Copyright DS SCIENCE INC. All rights reserved DS SCIENCE INC's advanced technology makes movable instrument for variety place from existing instrument for limitation place, and minimizes the consumption of lots of time and cost. Especially, it can protect the user's safety from pollution sources through exact data. 187, Gwangyeo-ro, Gonjiam-eup, Gwangju-si, Gyeonggi-do, Korea An ISO 9001 : Certified Tel : +82-31-798-6618 Fax : +82-31-798-6619 Homepage : www.dsscience.com E-Mail : dss@dsscience.com