A new detector for neutron beam monitoring

Similar documents
Neutron capture and fission reactions on. sections, -ratios and prompt -ray emission from fission. 1 Introduction and Motivation

Neutron imaging with a Micromegas detector

Detecting low energy recoils with Micromegas

Present and Future of Fission at n_tof

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

PoS(FNDA2006)010 FAST NEUTRON DETECTORS BASED ON MICROMEGAS TECHNOLOGY. S. Andriamonje * I. Giomataris and J. Pancin

GEM: A new concept for electron amplification in gas detectors

New neutron detector based on Micromegas technology for ADS projects

Neutron cross-section measurements at the n_tof facility at CERN

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Nuclear Instruments and Methods in Physics Research A

Neutron transmission and capture measurements for 241 Am at GELINA

High precision neutron inelastic cross section measurements

Breakdown limit studies in high-rate gaseous detectors

ACTAR TPC: an active target and time projection chamber for nuclear physics

Results with Micromegas modules at LP-TPC

on behalf of CAST Collaboration

Fission cross section measured at n_tof with PPACs

Principles of neutron TOF cross section measurements

Performance of a triple-gem detector for high-rate particle triggering

MICROMEGAS PERFORMANCE BASED IN ARGON- ISOBUTANE AND ARGON-DEMETHYL-ETHER

Determination of the boron content in polyethylene samples using the reactor Orphée

Study of GEM-like detectors with resistive electrodes for RICH applications

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Background optimization for a new spherical gas detector for very light WIMP detection

THE USE OF GE DETECTORS FOR (N,XN) CROSS-SECTION MEASUREMENTS AT INTENSE AND LOW FREQUENCY PULSED NEUTRON BEAMS. Abstract

Neutron capture cross section on Lu isotopes at DANCE

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. Letter of Intent to the ISOLDE and Neutron Time-of-Flight Committee

Neutron capture cross section of 25 Mg and its astrophysical implications

Advances in the Micro-Hole & Strip Plate gaseous detector

Waste Characterization

MICROMEGAS Signal: Numerical Simulation Based on Neon-Isobutane and Neon-DME

Preparatory experiments for cold-neutron induced fission studies at IKI

Fission Fragment characterization with FALSTAFF at NFS

Neutron cross sections in stellar nucleosynthesis: study of the key isotope 25 Mg

The 10 B(n,α 0. γ) 7 Li alpha-particle angular distributions, branching ratios and crosssections measurements for E n. < 3 MeV. ) 7 Li and 10 B(n,α l

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

An introduction to Neutron Resonance Densitometry (Short Summary)

ACTAR TPC: an active target and time projection chamber for nuclear physics. 17/09/2015 T. Roger COMEX 5 1

Arjan Plompen. Measurements of sodium inelastic scattering and deuterium elastic scattering

Solid state silicon + 6 LiF thermal neutron detectors: GEANT4 simulations versus real data

CHARACTERISTICS OF LIGHT CHARGED PARTICLE EMISSION IN THE TERNARY FISSION OF 250 CF AND 252 CF AT DIFFERENT EXCITATION ENERGIES

Gas-filled Detectors

A proposal to study gas gain fluctuations in Micromegas detectors

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

GEM-based photon detector for RICH applications

Electron transparency, ion transparency and ion feedback of a 3M GEM

Neutrons For Science

Measurement of prompt fission γ-ray spectra in fast neutroninduced

Simulation for LHC Radiation Background

Search for low-mass WIMPs with Spherical Detectors : NEWS-LSM and NEWS-SNO

The ACTAR project at SPES Status and perspectives

Nuclear Physics and Astrophysics

A Comparison between Channel Selections in Heavy Ion Reactions

Cross-section Measurements of Relativistic Deuteron Reactions on Copper by Activation Method

Tracking Detectors at HEP

Micro Pixel Chamber with resistive electrodes for spark reduction

EEE4106Z Radiation Interactions & Detection

arxiv: v1 [astro-ph.im] 6 Dec 2010

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

Performance test of triple GEM detector at CERN n_tof facility

NEW DEVELOPMENTS IN GASEOUS DETECTORS. Fabio Sauli. CERN, Geneva, Switzerland

Am cross section measurements at GELINA. S. Kopecky EC JRC IRMM Standards for Nuclear Safety, Security and Safeguards (SN3S)

R&D on Astroparticles Detectors. (Activity on CSN )

Contrabands detection with a low energy electron linac driven photoneutron source

Recent developments on Micro-Pattern Gaseous Detectors

Large high-efficiency thermal neutron detectors based on the Micromegas technology

CCD readout of GEM-based neutron detectors

Bulk Micromegas detectors for large TPC applications

JRC Place on dd Month YYYY Event Name 1

Study of the HARPO TPC for a high angular resolution g-ray polarimeter in the MeV-GeV energy range. David Attié (CEA/Irfu)

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

Neutron cross section measurement of MA

Status and Challenges of CEPC Time Projection Chamber Detector. Huirong On behalf of CEPC Tracking Subgroup

Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

IFIN-HH participation at the n_tof CERN COLLABORATION (I)

Micro-pattern gaseous detectors

Neutron Spectrometry in Mixed Fields: Characterisation of the RA-1 Reactor Workplace

physics/ Sep 1997

two-proton radioactivity discovery of two-proton radioactivity experimental results with TPC s future studies

Test-bench for the Characterization of MicroMegas Modules for the T2K ND280 TPC

Measurement of the 236 U(n,f ) Cross Section in the Neutron Energy Range from 0.5 ev up to 25 kev

Available online at ScienceDirect. Physics Procedia 64 (2015 ) Neutron-induced fission cross section of 240,242 Pu

Results and perspectives of the n TOF experiment.

Precision neutron flux measurement with a neutron beam monitor

Hybrid Gaseous Detector Module for CEPC-TPC

in2p , version 1-28 Nov 2008

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

Contribution of Small Facilities to the study of Nuclear Reactions

High-energy neutron-induced fission cross sections in

Status of evaluated data for neutron induced reactions on 238 U in the resonance region

arxiv:physics/ v1 [physics.ins-det] 2 Aug 2000

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Photofission of 238-U Nuclei

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

Status Report of the NFS collaboration

Nuclear AstroPhysics at ELI-NP: preliminary experiments with ELISSA detector. Giovanni Luca Guardo

Method of active correlations in the experiment 249 Cf+ 48 Ca n

Transcription:

A new detector for neutron beam monitoring European Organization for Nuclear Research (CERN), Geneva, Switzerland in collaboration with Commissariat à l Energie Atomique (CEA), Saclay, France, Instituto Tecnológico e Nuclear (ITN), Lisboa, Portugal, Institute for Reference Materials and Measurements (IRMM), Geel, Belgium, Istituto Nazionale di Fisica Nucleare (INFN), Bari, Italy and The n_tof Collaboration AccApp09: International Topical Meeting on Nuclear Research Applications and Utilization of Accelerators (Vienna 4-8 Mai 2009)

Motivation For the high precision in neutron cross-section measurements, the knowledge of the energy distribution of the neutron flux during the measurements is crucial Need a dedicated detector to measure the neutron flux impinging on the sample placed in the beam; it should be placed upstream of the sample position and of the different detectors in the measurement area. Main characteristics of this detector are: 1) have an in-beam mass as small as possible in order to minimize the perturbation on the neutron beam and to minimize the production of background by the device itself. 2) capable to cover a large range of the neutron energy (from thermal to several MeV) According to these considerations we have developed a new neutron detector equipped with a small-mass device based on Micromegas micro-bulk technology 1

Outline Micromegas for neutron detection The new Micro-Bulk concept Description of the new detector for neutron beam monitoring First results obtained at GELINA and n_tof Conclusion 2

Micromegas for neutrons detection (1) detection of charged particle by ionisation of the gas Main advantages of the Micromegas detector: robust and high resistance to radiation. Micromegas (MICRO Mesh Gaseous Structure) is a gaseous detector developed initially for tracking in high rate high-energy experiments (Y. Giomataris, Ph. Rebourgeard, J.P. Robert, G. Charpak, Nucl. Instr. and Meth. A 376 (1996) 29). The gas volume is separated in two regions by a thin micromesh; 1) Conversion and drift of the ionization electrons 2) Amplification and avalanche process 3) Charge collection in anode pad or strips These qualities have been exploited to develop a new neutron detector (, et al., Nucl. Instr. and Meth. A 535 (2004) 309). that can also be used in a nuclear reactor environment, operating under extreme conditions of intense neutron flux, high gamma ray background and high temperature (J. Pancin, et al., Nucl. Instr. and Meth. A 592 (2008) 104) 3

Need ionizing particules Solid Converter 6 Li+n 4 2 He(2.05MeV )+ 3 1 H(2.73MeV )Q = 4.78MeV 3 Use of two different kinds of neutron reactions for lower energy Micromegas for neutron detection (2) 10 B + n 2 4 He(1.47MeV )+ 3 7 Li(0.83MeV )Q = 2.7MeV 5 n + Fissile elements (with fission threshold for higher energy (< 1 MeV for 232 Th) Gas Converter: Elastic scattering on gas nuclei 1 H(n,n ) 1 H and 4 He(n.n ) 4 He for higher energy Neutron flux for E n fission threshold 4

The Micro-bulk concept* The micro-bulk principle consists of a manufactured grid starting from a coppered kapton film deposited on an anode of coppered epoxy. Copper and the Kapton are attacked by a chemical process in order to form : - a grid coppers - insulating kapton pillars with a thickness of the used film (50 or 25 microns) - anode copper Use of this procedure makes it possible to obtain a perfect alignment of the MicroMesh, the kapton pillars and the reading srtips. *Invented by I. Giomataris and R. De Oliveira 5

Performances of the Micro-Bulk Good overall energy resolution has been obtained: 10.5% at 5.9 kev of the Fe-55 X- ray source, 5.5% at 22 kev of the Cd-109 X- ray source, <1.5% with Am-241 a source. The combination of the high resolution and the fact that it is a gas detector allowed us to observe a favourable peak/valley ratio for the fission fragment distribution of 252Cf. 6

New development for transparent detectors Four new transparent (challenge*) Micro-bulk (F1 to F4) Vd is the negative High Voltage applied on the drift electrode, Vm is the negative High Voltage applied on the MicroMesh. The difference between Vd and Vm determines the gain applied on the detector Ar-Isobutane mixed gas has been used, the percentage of 2% of the Isobutane has been chosen to have a non-flammable gas for the use in CERN tunnel. *Ring in place of the epoxy support allows to have a detector with very thin material 7

Method to cover a large range of the neutron energy 10 B In order to cover the full range from thermal to above 1 MeV, two standard reactions have been chosen: 235 U(n,f) and 10 B(n,α). The 235 U(n, f) reaction is suited above a few 100 ev. 235 U Below that energy the resonance structure of 235 U(n, f) does not allow a precise determination of the neutron flux without taking into account detailed and complicated corrections. use of 2nd standard reaction 10 B(n,α) The combination of both elements ( 10 B and 235 U) makes it possible to have an excellent detector to measure the energy distribution of the neutron in a large neutron energy range from thermal to several MeV. 8

The Micromegas Micro-bulk for neutron beam monitoring Two Micromegas detectors equipped with very thin material Drift Electrode (1) The sputtering method has been used at CERN for the 10B (from B4C) deposit (very high evaporation temperature), on a copper coated kapton, 12.5 µm of kapton and 1 µm of copper Drift Electrtode (2) The 235U (1 mg U-235 (99.94%) sample was deposited on 1.2 µm of aluminised Mylar at JRC-IRMM in Geel using the evaporation method. To minimize the heating of the sample, a special device based on water-cooling has been fabricated. Micromesh + Anode strip = Micro-Bulk (5 µm Cu+ 25 µm Kapton + 5 µm Cu ) 9

Results obtained at GELINA facility The GELINA neutron source is based on a linear electron accelerator producing an electron beam The accelerated electrons produce Bremsstrahlung radiation in a uranium target, which in turn, by means of photonuclear reactions, produces neutrons. b) Na filter a) Neutron reaction product spectra from 10 B and 235 U b) Reaction rate as a function of neutron energy for 10 B and 235 U A premixed Ar + 10%CH 4 has been used 10

Result obtained during the short commissioning of the new target of the CERN n_tof facility (November 2008) (1) Neutron reaction product spectrum from 10 B (the use of the premixed gas of Ar + CF 4 + C 4 H 10 allows to distinguish clearly the contribution of the two components (1.47 MeV alpha and 0.83 MeV 7 Li) of the reaction products of the neutrons on 10 B). Neutron reaction product from 235 U (the peak at ch. ~240 is due to the saturation of the flash-adc). Due to the very limited beam time, which was dedicated for the test of the new lead target, the statistics accumulated were rather poor but sufficient to validate that this new concept can be used as a neutron beam monitoring device. 11

Result obtained during the short commissioning of the new target of the CERN n_tof facility (November 2008) (2) 10 B µmegas sample: ~1 µm, 3.5 cm ø 235 U µmegas sample: 1 mg, 2.0 cm ø 235 U FIC2 sample: 12.79 mg, 5 cm ø Fission Ionisation Chamber (FIC) 60% discrepancy between µmegas 10 B and µmegas 235 U ( 10 B mass uncertainty) 50% discrepancy between FIC2/µMEGAS and official capture * L FIC2 = 192.65 m (L 2004 + 10 cm new mod) L µmegas = 182.0 m *bad alignment (0.9 mm) of the collimator Φ=1.8 cm 12

Conclusion We have developed a new neutron detector based on Micromegas Micro-Bulk technology. A challenge was launched to obtain a neutron transparent detector as a monitor of the neutron beam. That concerns not only the design of the detector but also the manufacturing of the neutron/charged particle converters. The first results show clearly the capability to use this type of detector for the future measurements on the neutron beam line. 13