The X- ray Integral Field Unit calibra5on plan

Similar documents
The Athena X-ray Integral Field Unit

New generation X-ray telescope

Athena status and a focus on its timing capabilities

Athena Athena+ Towards a European Large X-ray Observatory. Mike Watson University of Leicester. Athena+

Future X-rayX Spectroscopy Missions. Jan-Willem den Herder

The perspective of X-ray galaxy clusters with the XIFU/Athena instrument

The Athena X-ray Observatory (and its X-ray Integral Field Unit) Didier Barret Ins=tut de Recherche en Astrophysique et Planétologie

ATHENA Mission Design and ESA Status. David Lumb ESA Study Scientist MPE Jan 13 th 2012

Advanced Telescope for High Energy Astrophysics

Calibration of the IXPE Instrument

ASTRO-H ASTRO-H and future missions in JAXA program. Tadayuki Takahashi PI/Project Manager on behalf of the ASTRO-H team

The High Resolution X-ray Spectrometer, SXS, on the Astro-H mission

AC Fabian, M. Cappi, J Sanders. Cosmic Feedback from AGN

Paul Plucinsky on behalf of Randall Smith on behalf of the ESA JAXA NASA IXO team

Chandra was launched aboard Space Shuttle Columbia on July 23, 1999!!!

Hitomi constraints on the atomic codes

X-ray Quantum Calorimeter (XQC)

H- and He-like X-ray emission due to charge exchange

The X-Ray Universe. Potsdam University. Dr. Lidia Oskinova Wintersemester 2008/09

ATHENA : the Advanced Telescope for High ENergy Astrophysics. LTD16 Conference. Centre de Congrès WTC, Grenoble, France July 20th - 24th 2015

Discovery of Emission Lines in the X-ray Spectrum of the Perseus Cluster

Neutron Stars at X-ray Wavelengths: NASA's Constellation-X Mission. Divas Sanwal (JHU/GSFC) Constellation-X NASA GSFC

Lecture 7 Pumping & Popula3on Inversion*

Geant4-based simulations of the background for the erosita space observatory (with connections to IXO and Suzaku)

Centre for Electronic Imaging

INTEGRAL/IBIS calibration status

RCUS. MIT Kavli Institute. 1 Summary. 2 Diffuse Sky Simulation. MEMORANDUM November 16, 2017

Simula'ons as a tool for higher mass resolu'on spectrometer: Lessons from exis,ng observa,ons

Contamination WG Summary

Performance Testing of the Astro-H Flight Model 3-stage ADR

The EBIT Calorimeter Spectrometer: a new, permanent user facility at the LLNL EBIT

A NEW GENERATION OF GAMMA-RAY TELESCOPE

SDO/EVE/ESP and SOHO/ SEM Inter-Calibration and Degradation

Diamond Neutral Par0cles Spectrometer at JET and proposal for ITER

XMM-Newton SOC Technical Note

Remote and surface X ray experiments of small bodies. T. Okada (JAXA, Japan)

IBIS - IN FLIGHT CALIBRATION ACTIVITIES

EPIC Straylight. telescopes/sieves/rga revisited. David Lumb, Athena Study Scientist

NIST Research on Spectroscopy and Collisional-Radiative Modeling of Highly-Charged Ions of Tungsten

On ground and in-flight calibration. Fabio Muleri INAF-IAPS

Ares V Astronomy Workshop Ames, April Generation-X: A Mission Enabled by Ares V

Evaluation of the capabilities of the XMM-Newton SciSim from the EPIC calibration point-of-view. André Burzlaff, FH Aachen

This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

Simultaneous XMM-Newton Radio Observations of the Mode-switching Radio Pulsar PSR B Wim Hermsen 1,2

Computational Challenges from Imaging X-ray Polarimetry. Herman L. Marshall (MIT) and the IXPE Team

AGN Selec)on Techniques. Kris)n Kulas Astro 278 Winter 2012

Gravity and the Universe

Physics of the hot evolving Universe

XMM-Newton - Chandra Synergy: Maximizing their Future Science Impact over the Next Decade

Large Area X-ray Propor.onal Counter (LAXPC) instrument and ini.al science results (from payload verifica.on phase)

X-ray burst science with Astrosat

Outline. Great X-Ray Observatories. a ThousandPictures. CCD Spectral Resolution & Discerning Orders. X-Ray Grating Spectrometers

A search for burst spectral features with NICER. Jérôme Chenevez Gaurava Jaisawal DTU Space

An end-to-end X-IFU simulator: constraints on ICM kinematics

X- & γ-ray Instrumentation

The EMPIRE survey: CO(1-0) emission across nearby disks. Diane Cormier. Marie-Curie Fellow, AIM/CEA Saclay

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Phonon-Mediated Distributed Transition- Edge-Sensor X-ray Detectors

ENERGY SCALE IN EPIC-PN TIMING MODE

Development of a 3D-Imaging Calorimeter in LaBr 3 for Gamma-Ray Space Astronomy

Galaxy Clusters with XEUS. Silvano Molendi Stefano Borgani Stefano Ettori

Week 13, Lecture 3 Radia2on Detectors 1

Integral Field Spectroscopy. David Burnham & Trystyn Berg

X-Ray observability of WHIM and our new mission concept DIOS Intergalactic. Oxygen. Surveyor ) Noriko Yamasaki ISAS/JAXA

NuSTAR Bringing the High Energy Universe into Focus. IACHEC 2016 Pune 1

XMM-Newton Calibration

SMILE Solar wind Magnetosphere Ionosphere Link Explorer Novel and global X-ray imaging of the Sun Earth connection

Lynx and Exoplanet Science. Rachel Osten, STScI & JHU

RGS CALIBRATION STATUS

The Sun as a Typical Star. Stellar Spectra. Stellar Spectroscopy

The Future of Neutrino Mass Measurements: Terrestrial, Astrophysical, and Cosmological Measurements in the Next Decade. Seattle February 8-11, 2010

Theore&cal evalua&on of fluorescence emission and energy deposi&on in air generated by electrons

Planning and Analyzing WFIRST Grism Observa:ons

Studying microquasars with X-ray polarimetry

Gamma-ray satellites Fermi Gamma-ray Space Telescope

Measuring the Neutron Star Mass-Radius Relationship with X-ray Spectroscopy

The WFIRST High La/tude Survey. Christopher Hirata, for the SDT November 18, 2014

NuSTAR observation of the Arches cluster: X-ray spectrum extraction from a 2D image

Status and Calibration of the erosita X ray Telescope

When a Standard Candle Flickers: The Dimming of the Crab Nebula. Gary Case

Gamma- Rays from SN2014J

IV. Surface analysis for chemical state, chemical composition

NuSTAR s Extreme Universe. Prof. Lynn Cominsky NASA Education and Public Outreach Sonoma State University

Problem Solving. radians. 180 radians Stars & Elementary Astrophysics: Introduction Press F1 for Help 41. f s. picture. equation.

Deciphering the accretion structure in Vela X-1

Ground Calibration of X-ray CCD Detectors with Charge Injection for the X-ray Imaging Spectrometer on Astro-E2

arxiv: v1 [astro-ph.im] 18 Jul 2018

The EarthCARE mission: An active view on aerosols, clouds and radiation

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

XMM-Newton Optical-UV Monitor: introduction and calibration status OM instrument and calibration

Comets observed with XMM-Newton

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

arxiv: v1 [physics.ins-det] 9 Apr 2016

Application of atomic data to quantitative analysis of tungsten spectra on EAST tokamak

Science Update SBAG July, Andrew Cheng (JHU/APL) Karl Hibbitts (JHU/APL) Eliot Young (SwRI)

Scin/lla/on of liquid neon Photon Detec/on at 27 K

NuSTAR. The Nuclear Spectroscopic Telescope Array Extragalac6c Program. Andrea Marinucci Università degli Studi Roma Tre. on behalf of the NuSTAR team

Advanced beam manipula/ons

Transcription:

The X- ray Integral Field Unit calibra5on plan Ins5tut de Recherche en Astrophysique et Planétologie April 10 th 2018-13 th IACHEC Mee5ng - Avigliano Umbro

A jump in high sensi5vity high resolu5on spectroscopy Pajot et al. JLTP 2018 Athena/X-IFU XARM/Resolve Weak line sensitivity FoM = A eff /ΔE 20 15 10 5 - Effec5ve area of the Athena/X- IFU instrument compared to current (Chandra/HEGT, XMMNewton/ RGS) or near future (XARM/Resolve, assuming the same response as Hitomi/SXS) X- ray imaging spectrometers in the 0.2 12 kev energy range. DB/X-IFU - x 10 0 0,1 1 10 Energy (kev) Weak line sensi5vity factor of merit of the Athena/X- IFU instrument compared to the next and only high resolu5on imaging spectrometer XARM/Resolve. High resolu5on spectrometry refers to instruments achieving a beser than 10 ev energy resolu5on, a capability now enabled in space by micro- calorimeter arrays 2

X- IFU spectroscopy on clusters simula5ons Barret et al. SPIE 2016 1 O Fe L Mg Si S Ar Ca 10 1 Fe-K Counts/s/keV 10 2 10 3 10 4 Athena X-IFU XMM-Newton EPIC PN Hitomi SXS 0.2 0.5 1 2 5 Energy (kev) - Reconstructed bulk mo5on velocity field of the hot intra- cluster gas for a 50 ks X- IFU observa5on of the central parts of a Perseus like cluster considered at a redshic of 0.1 - Simulated X- IFU spectrum of a z = 1 galaxy group with kt = 3 kev and L X = 1 x 10 44 erg/s for 50 ks. Emission lines from elements which are key to understand chemical evolu5on can be clearly seen. 3

The X- ray Integral Field Unit Parameters Requirements Energy range 0.2 12 kev Energy resolu5on 1 : E < 7 kev 2.5 ev Energy resolu5on: E > 7 kev E/ΔE = 2800 Field of View 5ʹ (equivalent diameter) Effec5ve area @ 0.3 kev > 1500 cm 2 Effec5ve area @ 1.0 kev > 15000 cm 2 Effec5ve area @ 7.0 kev > 1600 cm 2 Gain calibra5on error (peak, 7 kev) 0.4 ev Count rate capability nominally bright point sources 2 1 mcrab (> 80% high- resolu5on events) Count rate capability brightest point sources 1 Crab (> 30% throughput) Time resolu5on 10 µs Non X- ray background (2 10 kev) < 5 10-3 counts/s/cm2/kev (80% of the 5me) 1 goal 1.5 ev, 2 goal 10 mcrab (> 80% high- resolumon events) events - Consor5um led by CNES/IRAP- F, with SRON- NL, INAF- IT and other European partners, NASA and JAXA. 4

X- IFU detectors and dewar 3840 TES microcalorimeters array at 50 mk Associated to a 4 pixels anticoincidence TES detector Pulse tubes and JTs flange Outer vessel (300K) Outer Cold Shield (OCS -100K) Inner Cold Shield (ICS -30K) 4K shield 2K structure Aperture cylinder (allocated volume) Baseline cryochain 50 mk 5

X- IFU calibra5on - Most of the X- IFU top- level calibra5on requirements stem directly from the Athena level - all calibra5ons will be performed at pixel level - some addi5onal requirements may be added by the instrument to lower levels (e.g. door calibra5on) - Experience from work done for HITOMI/SXS and XARM/Resolve micro- calorimeter arrays is essen5al - defini5on of requirements - calibra5on methodology specific to microcalorimeters - on- ground and instrument calibra5on sources (gra5ng monochromators, channel- cut crystal monochromators, EBITs, ) - in- flight targets defini5on - Low energy range will benefit from gra5ng instruments such as ARCUS - physics, astrophysical sources Electron Beam Ion Trap (EBIT) 6

X- IFU calibra5on from ground to space 1.6 cm In-orbit Component (microcalorimeter array, ) SIM (science instrument module) 15 m X-IFU dewar Spacecraft 7

X- IFU main calibra5on requirements Requirement Name Athena Mirror X- IFU Comments Absolute effec5ve area on- axis calibra5on (%) Rela5ve effec5ve area, broad- band on- axis (%) Rela5ve effec5ve area, fine structure (%) Knowledge of gain (ev) Energy resolu5on calibra5on (%) Energy redistribu5on calibra5on CAL- EFF- R- 001 10 6 4 CAL- EFF- R- 003 5 (X- IFU), 3 (WFI) 2 3 CAL- EFF- R- 005 1 (TBC) 1 TBD CAL- ENR- R- 001 CAL- ENR- R- 003 0.4 (X- IFU), 10 (WFI) 6 (X- IFU), TBD (WFI) N/A 0.4 N/A 6 CAL- ENR- R- 004 TBD N/A TBD Dead 5me (%) CAL- TIM- R- 001 1 N/A 1 Photon rela5ve 5ming (µs) Non- focused background reproducibility Focused background (%) reproducibility (%) CAL- TIM- R- 003 10 (X- IFU) 5000/80 (WFI) N/A 10 CAL- BKG- R- 001 2 N/A 2 CAL- BKG- R- 002 10 N/A 10 At the 1σ level Over the [0.5-10 kev] bandpass At the 1σ level Over the [0.5-10 kev] bandpass At the 1σ level Working from XARM/RESOLVE req. r.m.s. varia5on in [0.3-7 kev] [allows centroiding to 20 km/s at 7 kev] Over the [0.3-7 kev] bandpass [turbulence to 20 km/s at 7 kev] Working from HITOMI/SXS experience and calibra5on data All dead 5me is introduced during processing and known r.m.s. error (absolute requirement is 50 µs at Athena level) Goal 1%. For observa5ons longer than 100 ks over 9' For observa5ons longer than 100 ks over 9 squared arc minutes 8

High resolu5on spectroscopy Atomic Database/Lab Measurement Needs Energies / wavelength - Athena will measure veloci5es to 20 km/s at 7 kev (~0.006%) or wavelength accuracy to 3 må at 10 Å (~0.03% at 1.2 kev) - Accuracy of wavelength current values is ~1% (Smith+Brickhouse 2014) Natalie Hell, PhD Thesis 2017 9

High resolu5on spectroscopy Atomic Database/Lab Measurement Needs Energies / wavelength - Athena will measure veloci5es to 20 km/s at 7 kev (~0.006%) or wavelength accuracy to 3 må at 10 Å (~0.03% at 1.2 kev) - Accuracy of wavelength current values is ~1% (Smith+Brickhouse 2014) Experiment (various) vs. Calculation (Drake 1988) for He-like (w/resonance) lines (1s2p 1 P 1 1s 2 1 S 0 ) Beiersdorfer + Brown, 2015 10

High resolu5on spectroscopy Atomic Database/Lab Measurement Needs Other parameters mostly related to in- flight data analysis - Collisional excita5on rates! diagnos5c line ra5os - Radia5ve transi5on rates! accurate cascades - Photoioniza5on/absorp5on rates! charge state distribu5on - Charge Exchange cross sec5ons! ioniza5on balance, line ra5os - 11

X- IFU Calibra5on plan Prepared by : - the X-IFU Calibration Team (XCaT): Marco Barbera, Edoardo Cucchetti, Megan Eckart, Philippe Ferrando, Jean-Michel Mesnager, Lorenzo Natalucci, Philippe Peille, Jelle de Plaa, Etienne Pointecouteau - with contribution from: M. Leutenegger, G. Betancourt-Martinez First issue December 2018 (for the Instrument Preliminary Requirement Review) 1. Presenta5on of the document 2. Objec5ves of the calibra5on plan 3. X- IFU calibra5on requirements 4. X- IFU calibra5on strategy outline 6. Specific analysis and software tools 7. Fundamental/lab physics of X-ray emission at high resolution 8. Summary of calibration hardware needs 5. Calibra5on strategy and implementa5on 5.1. Energy scale calibra5on 5.2. Energy resolu5on and redistribu5on calibra5on 5.3. Quantum efficiency calibra5on 5.4. Background 5.5. Straylight 5.6. Timing calibra5on 12

The end / the beginning 13