TEST REPORT No. : XMML Date : Jan.06, 2012 Page: 1 of 12

Testing of Ancaster Limestone. Prepared for: Phil Kerry Goldholme Stone Ltd. Irnham Grange Irnham Road Corby Glen Grantham Lincolnshire NG 33 4 NE

IT-AP INFORMATION REGARDING THE CE MARK

Testing of Lincolnshire Limestone. Prepared for: Phil Kerry Goldholme Stone Ltd. Irnham Grange Irnham Road Corby Glen Grantham Lincolnshire NG 33 4 NE

ISO 178 INTERNATIONAL STANDARD. Plastics Determination of flexural properties. Plastiques Détermination des propriétés en flexion

Stone Construction Products Physical and Mechanical Characterisation. Vera Pires

TEST REPORT No. 50 PERFORMED TESTS:

TEST REPORT No. Date : Page:

Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation 1

ISO 178 INTERNATIONAL STANDARD. Plastics Determination of flexural properties. Plastiques Détermination des propriétés en flexion

product manual H-3030, H-3032, H-3033 Concrete Beam Tester

Wikipedia.org BUILDING STONES. Chapter 4. Materials of Construction-Building Stones 1

TEST REPORT No. : XMML Date : Apr. 26, 2010 Page : 1 of 15

Project PAJ2 Dynamic Performance of Adhesively Bonded Joints. Report No. 3 August Proposed Draft for the Revision of ISO

EVALUATION OF GRAMPIAN SAND SANDSTONE

STONE Pietra del Cardoso

10/15/2016. Building stones

RECOMMENDED APPLICATIONS AND FINISHES TABLE

Effects of Basalt Fibres on Mechanical Properties of Concrete

Terms and Conditions of Participation. for the Goethe-Institut's "Advent Calendar 2018" lottery at and Instagram

Table of Contents. Foreword... xiii Introduction... xv

CONCRETE TECHNOLOGY LABORATORY

Physical Properties Testing Technical Bulletin

Paseo Recoletos, nº Madrid TEST REPORT

New Policies on Chemical Environmental Management in China. Gao Yingxin Chemical Registration Center of MEP September 9, 2010

Experimental study of mechanical and thermal damage in crystalline hard rock

Statistical Report on the Access to Information Act

STEEL. General Information

ULTRASONIC PULSE METHOD THE CEMENT STRENGTH EVALUATION TOOL

Capricorn Panel Research Survey Terms and Conditions

GATE SOLUTIONS E N G I N E E R I N G

GB/T / ISO 527-1:1993

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Test Report n 0412/11 of the 28 th September 2011

Laboratory 4 Bending Test of Materials

Thursday 17 May 2012 Morning

ACRIFIX. Adhesives and Auxiliaries

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German

Loading tests of threaded inserts for determination of tensile and shear resistances

Tensile stress strain curves for different materials. Shows in figure below

INTERNATIONAL STANDARD

3 Flow properties of bulk solids

STONE. What is Dimension Stone? 3/23/17

Salt Crystallization in Hydrophobic Porous Materials

Experiences with the use of the Rock Manual, 2 nd edition, and EN13383 in selecting appropriate test methods and frequencies

D y E y = E y. Legend:

Guide to Registration Requirements for Active Substance Manufacturers, Importers and Distributors in Ireland

Control Standard for Handling Chemical Substances in Products, Parts and Materials

CE : CIVIL ENGINEERING

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

Diamond Wire Cutting Test in Nordic Winter Time

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate

TFI Report Sound Absorption Impact Sound Insulation

Manual Railway Industry Substance List. Version: March 2011

Accelerated Testing Methodology for Long Term Durability of CFRP

Predicting Los Angeles abrasion loss of rock aggregates from crushability index

Mechanics of Earthquakes and Faulting

GIs and the Community trade mark system the practice of the OHIM (ECTA round table on Geographical Indications and the Community Trade Mark System)

University Physics (Prof. David Flory) Chapt_14 Thursday, November 15, 2007 Page 1

TFI Report Sound Absorption Impact Sound Insulation

Product Data Sheet PD-0037-B

Correlation between wide wheel abrasion (capon) and Bohme abrasion test results for some carbonate rocks

ROCK TUMBLING: An Experimental Investigation of Physical Weathering

MATERIAL and/or SAMPLE to be tested : CERAMIC TILES;

Hydrocarbon Fluid Wave and it's resonance G.K. Batta*, D.S. Manral, G.V.J. Rao, and S.K. Basha, Oil India limited, India

Digital Mapping License Agreement

Strain Gage Calibration Factors for Constant Room Temperature Conditions. Gage Resistance, Gage Factor and Transverse Sensitivity Coefficient)

TECHNICAL NOTE PREDICTION OF PAVEMENT SURFACE SKID RESISTANCE AND THE EFFECT OF SMALLER CHIP SIZE

PHY218 SPRING 2016 Review for Final Exam: Week 14 Final Review: Chapters 1-11, 13-14

REQUEST FOR QUOTATION (RFQ) FOR PROCUREMENT OF THERMO HYGROMETER -UNDP GLOBAL FUND

STANDING COMMITTEE ON GEOGRAPHICAL INDICATIONS QUESTIONNAIRE TO NATIONAL GROUPS

1. What would be the value of F1 to balance the system if F2=20N? 20cm T =? 20kg

DuPont Zenite LCP. liquid crystal polymer resin PRODUCT AND PROPERTY GUIDE

SOUTH AFRICAN NATIONAL STANDARD. Modulus of elasticity and modulus of rupture in static bending of fibreboards Amdt 1

Experiment Five (5) Principal of Stress and Strain

Standard Practice for Heat Aging of Plastics Without Load 1

Welcome to the Spreadsheet for Linear Buckling Analysis of Stiffened Plate Panels (as per DNV RP-C-201)

ASTM upvc Schedule 80

Anemometer Thermometer Hygrometer

Letter to non European Union customers

DECLARATION OF PERFORMANCE No. 37/X-PIR/OBO

PIEDRA NATURAL ASERRADA Y DE CANTERÍA, S.L

Basic Examination on Assessing Mechanical Properties of Concrete That Has Suffered Combined Deterioration from Fatigue and Frost Damage

TFI Report Sound Absorption Impact Sound Insulation

Calibration of Temperature Block Calibrators

SVENSK STANDARD SS-EN :2005. Konststen Provningsmetoder Del 6: Bestämning av beständighet mot plötslig temperaturförändring (termisk chock)

Impact resistance of laterally confined fibre reinforced concrete plates

Specific Accreditation Guidance. Infrastructure and Asset Integrity. Measurement Uncertainty in Geotechnical Testing

PRODUCT SPECIFICATION

Rock and fluid thermodynamics control the dynamics of induced earthquakes

Transcription:

Page 1 of 12 RESULTS REPORT OF TEST Report Nº: IE141804 PETITIONER D. Gregorio Berná BATEIG PIEDRA NATURAL, S.A. CAMÍ DE CASTELLA 112, B.º ESTACION 03660 NOVELDA ALICANTE NIF: A03099405 FURTHER INFORMATION: Specimen/s: DELIVERY REGISTRATION SPECIMEN IDENTIFICATION NOTE Nº: DATE: ACCORDING TO APPLICANT: MATERIAL: QUANTITY: RECEPTIÓN: 72116 23/05/2014 Bateig Azul-Galaxy Natural Stone 76 tiles Sent by the applicant Test/s Carried out Nº: DESCRIPTION REGULATION: 1 Determination of water absorption at atmospheric pressure UNE-EN 13755:2008 1 Determination of apparent density and open porosity UNE-EN 1936:2007 1 Determination of the abrasion resistance UNE-EN 14157:2005 1 Determination of uniaxial compressive strength UNE-EN 1926:2007 1 Determination of rupture energy UNE-EN 14158.2004 1 Determination of resistance to salt crystallisation UNE-EN 12370:1999 1 Determination of the slip resistance by means of the pendulum tester UNE-EN 14231:2004 1 Determination of water absorption coefficient by capillary UNE-EN 1925:1999 1 Determination of frost resistance UNE-EN 12371:2011 Paterna, on Thursday 12 nd of June 2014 Signed: Dª Rocío Correoso Cano Technician of the Natural Stone Laboratory Signed: Mr. José Manuel Cuevas Castell Responsible of the Natural Stone Laboratory RESPONSIBILITY CLAUSES 1 st AIDICO is only responsible for the results on the analysis methods used and recorded in this document and referred, exclusively, to the material or specimens described on it and which remain in this power, and only those shall be covered by the legal responsibility of the centre. Unless otherwise stated, the samples have been freely chosen and sent by the applicant. 2 nd This Institute shall not be held responsible for the misconstruction or misuse of this document, the partial copying of which is strictly forbidden without AIDICO s written consent. 3 rd The results of this report are a property of the applicant and AIDICO shall nor disclose them to third parties without the applicant s prior consent. 4 th None of the indications registered on this document shall be a guarantee for the trade names mentioned. 5 th In case of discrepancies among test reports, a decisive verification shall be carried out at AIDICO s head office. Likewise the applicant shall be held responsible of advising this centre about any complaints which he may receive caused by a result different to the one on the report issued by AIDICO and, if he does not do so, he shall exempt this centre from any responsibilities.

Page 2 of 12 DETERMINATION OF APPARENT DENSITY AND OPEN POROSITY UNE-EN 1936 :2007 Apdo.8.1 Surface finish : Raw START END Date test 02/06/2014 03/06/2014 Higher Lower Temperature 25,4 21,4 Dimensions of the specimens : 50 x 50 x 50 mm Specimen 1 2 3 4 5 6 Apparent density (kg/m 3 ) 2230 2290 2260 2240 2310 2290 Open porosity (%) 13,6 13,6 13,5 13,4 13,4 13,5 AVERAGE Apparent density (kg/m 3 ) 2270 Open porosity (%) 13,5 ADDITIONAL DATA OF TEST:

Page 3 of 12 DETERMINATION OF UNIAXIAL COMPRESSIVE STRENGTH UNE-EN 1926:2007 Surface finish : Raw Registration date 23/05/2014 START END Date test 27/06/2014 30/06/2014 Specimen 1 2 3 4 5 6 7 8 9 10 Height, h (mm) Average side (mm) Breaking load, F(kN) Compressive Strength (MPa) 50,0 50,0 53,0 50,0 50,0 50,0 50,0 53,0 53,0 53,0 51 51 50 51 52 51 52 50 50 50 230 240 200 200 260 200 210 210 210 210 90,5 91,6 79,2 75,9 97,7 76,5 78,9 83,6 84,2 85,3 Mean value of Compressive Strength, (MPa) 84 Standard deviation (MPa) 7 Coefficient of variation, v 0,085 ADDITIONAL DATA OF TEST:

Page 4 of 12 DETERMINATION OF WATER ABSORPTION COEFICIENT BY CAPILLARY UNE-EN 1925:1999 Surface finish : Raw START END Date test 18/07/2014 18/07/2014 Higher Lower Temperature 23,8 23,4 Dimensions (mm) : 50 x 50 x 50 Specimen 1 2 3 4 5 6 Dimensions (Side) (mm) Water absorption coeficient by capillary (g/m 2.s 0,5 ) Mean value of water absorption coefficient by capillary (g/m 2.s 0,5 ) 50,22 51,84 50,24 51,75 51,67 51,79 11,651 13,028 11,713 12,749 13,027 13,829 12,666 ADDITIONAL DATA OF TEST:

Page 5 of 12 DETERMINATION OF RESISTANCE TO SALT CRYSTALLISATION UNE-EN 12370:1999 Surface finish : Raw START END Date preparation 28/05/2014 2/06/2014 Date test 02/06/2014 27/06/2014 Specimen 1 2 3 4 5 6 Width (mm) 40,98 40,33 40,51 40,38 40,56 40,42 Thickness (mm) 40,43 40,53 41,04 41,21 41,07 41 Length (mm) 40,31 41,03 40,09 40,41 40,42 40,48 Variation of mass M (%) Mean value of variation of mass M (%) 1,35 1,61 1,22 1,11 0,83 0,71 1,14 ADDITIONAL DATA OF TEST : The increment of the weight of the samples is probably caused by the presence of salt crystals in the porous media of the rock.

Page 6 of 12 Photo 1 Photo 2

Page 7 of 12 DETERMINATION OF WATER ABSORPTION AT ATMOSPHERIC PRESSURE UNE-EN 13755:2008 Surface finish : Raw Dimensions of the specimens (mm) : 50 x 50 x 50 mm Registration date 23/05/2014 START END Date test 02/06/2014 05/06/2014 Higher Lower Temperature 25,7 20,3 Specimen Nº 1 2 3 4 5 6 Dimensions (Lade) (mm) Water absorption (%) 51,42 51,26 50,98 51,49 51,34 51,28 5,0 4,8 5,0 5,0 4,9 4,9 Water Absorption medium (%) 4,9 ADDITIONAL DATA OF TEST: COMMENTS :

Page 8 of 12 DETERMINATION OF THE ABRASION RESISTANCE UNE-EN 14157:2005 Surface finish : Honed Dimensions of the specimens : 150 x 150 x 18 mm Registration date 23/05/2014 START END Date test 11/06/2014 11/06/2014 Value of calibration 0,3 PROBETA Specimen Dimensions (mm) 1 2 3 4 5 6 150,14x150,06x18,83 149,95x150,26x18,78 150,14x149,92x19 149,76x150,2x19,11 150,09x150,52x18,52 150,5x148,93x19,37 Dimension of the Groove (mm) 24,5 24,5 26,0 25,0 26,0 26,0 Average Value (mm) 25,33 ADITIONAL DATA OF TEST : COMMENTS :

Page 9 of 12 DETERMINATION OF RUPTURE ENERGY UNE-EN 14158:2004 Surface finish : Honed START END Date preparation 26/05/2014 28/05/2014 Date test 28/05/2014 28/05/2014 Specimen 1 2 3 4 5 Width (mm) 200,09 200 199,83 200,07 199,89 Thickness (mm) 29,33 29,4 29,02 28,72 30,06 Length (mm) 199,7 199,89 200,35 199,95 199,93 Rupture Energy, W (J) Average Rupture Energy (J) 3 3 3 3 3 3 ADITIONAL DATA OF TEST : COMMENTS :

Page 10 of 12 DETERMINATION OF FLEXURAL STRENGTH UNDER CONCENTRATED LOAD UNE-EN 12372:2007 Surface finish : Saw Dimensions : 300 x 50 x 50 mm START END Higher Lower Preparation date 09/06/2014 16/06/2014 Tª (ºC) 24,5 23,8 Test date 09/05/2014 10/09/2014 Specimen 1 2 3 4 5 6 7 8 9 10 Span distance l (mm) 268,4 269,5 251,2 269,2 270,8 270,4 269,6 270,4 268,1 251,1 Breaking load, F (N) 4760 5010 4570 4380 4710 4900 3910 4900 3490 4690 Thickness along breaking plane (mm) Width along breaking plane (mm) Breaking zone 53,7 53,7 50,0 53,6 53,7 53,9 53,5 54,0 53,7 50,6 50,0 49,8 54,0 49,9 50,3 50,4 50,1 50,1 50,0 53,5 15% l 15% l 15% l 15% l 15% l 15% l 15% l 15% l 15% l 15% l Flexural Strength, R tf (MPa) 13,3 14,1 12,8 12,3 3,2 13,6 11,0 13,6 9,7 12,9 Mean value of Flexural Strength, Rtf (MPa) 12,7 Standard deviation, s (MPa) 1,3 Lower expected value, E (MPa) 9,9 Speed load was 0,25 MPa/s. ADITIONAL TEST DATA:

Page 11 of 12 DETEMINATION OF FROST RESISTTANCE UNE-EN 12371:2002 DETERMINATION OF FLEXURAL STRENGTH UNDER CONCENTRATED LOAD 84 CICLES FREEZE/THAW UNE-EN 12372:2007 START END Higher Lower Preparation date 09/06/2014 10/09/2014 Tª (ºC) 26,8 25,3 Test date 09/05/2014 10/09/2014 Specimen 11 12 13 14 15 16 17 18 19 20 Span distance l (mm) 245,3 248,8 250,0 249,1 249,8 248,6 248,9 268,5 268,7 248,3 Breaking load, F (N) 5000 4520 4420 4710 3940 4030 5000 5000 4910 4130 Thickness along breaking plane (mm) 49,4 50,0 49,7 51,7 50,1 50,1 50,1 53,9 52,7 49,6 Width along breaking plane (mm) 53,8 54,0 53,5 53,7 55,4 53,7 54,0 49,7 49,9 53,8 Breaking zone 15% l 15% l 15% l 15% l 15% l 15% l 15% l 15% l 15% l 15% l Flexural Strength, R tf (MPa) 14,0 12,5 12,5 12,3 10,6 11,1 13,8 13,9 14,3 11,6 Mean value of Flexural Strength, (MPa) 12,7 Standard deviation, s (MPa) 1,3 Lower expected value, E (MPa) 10,1 Variation of flexural strength, R tf (%) 0,0 Speed load was 0,25 MPa/s. ADITIONAL TEST DATA: COMENTS:

Page 12 of 12 DETERMINATION OF THE SLIP RESISTANCE BY MEANS OF THE PENDULUM TESTER UNE-EN 14231:2004 Surface finish : Honed Dimensions of specimens : 200 x 200 x 20 mm Registration date 23/05/2014 START END Date test 09/07/2014 09/07/2014 Size of the rubber sliders : 76 mm. Specimen identification USRV (mean value for test specimen) USRV (of the specimen) Specimen identification USRV (mean value for test specimen) USRV (of the specimen) DRY CONDITIONS 1 2 3 4 5 6 49 56 51 50 50 51 51 WET CONDITIONS 1 2 3 4 5 6 55 59 54 56 55 55 56 ADITIONAL DATE OF TEST: