Tips & Tricks GPC/SEC: Protein Analysis with Size-Exclusion Chromatography

Similar documents
Tips & Tricks GPC/SEC: Inter-Detector Delay

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Tips & Tricks GPC/SEC: From a Chromatogram to the Molar Mass Distribution

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

The power of multi-detector SEC in the analysis of antibodies

Protein separation and characterization

An Introductions to Advanced GPC Solutions

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

GPC/SEC An essential tool for polymer analysis

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

How to use GPC/SEC for compositional analysis

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Sepax SRT -C, Zenix -C SEC Phases

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Benefit of light scattering technologies (RALS/LALS/MALS) and multidetection characterization in life science research?

Tips & Tricks GPC/SEC: Branching Analysis

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Polymer analysis by GPC-SEC. Technical Note. Introduction

Use of SEC-MALS. (Size Exclusion Chromatography - Multi Angle. Light Scattering) for protein quality and characterization

II. The physico-chemical properties of proteins

Liquid Chromatography

Optimizing GPC Separations

EcoSEC - semi-micro GPC/SEC system for high throughput polymer analysis

Size Exclusion Chromatography in the Presence of an Anionic Surfactant

Field-Flow Fractionation of Macromolecules and Structures That Cannot be Characterized by Conventional GPC/SEC Techniques

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

Macromolecular Chemistry

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Particle Characterization Laboratories, Inc.

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

How switching mobile phases can improve your OMNISEC results

Introduction to Pharmaceutical Chemical Analysis

Liquid Chromatography

ProPac WCX-10 Columns

GPC/SEC Column Selection & Method Development

INTRODUCTION. Amino acids occurring in nature have the general structure shown below:

High Performance Liquid Chromatography

Biochemistry. Biochemical Techniques HPLC

Sem /2007. Fisika Polimer Ariadne L. Juwono


Dr. Christoph Johann Wyatt Technology Europe GmbH Copyright Wyatt Technology Europe GmbH All Rights reserved 1

Meet Our Uncle: 12 Stability Applications on One Platform

Static and dynamic light scattering. Cy Jeffries EMBL Hamburg

Analysis of PEGylated Proteins with Agilent AdvanceBio SEC Columns

Chapter 31 Gas Chromatography. Carrier Gas System

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

HPLC Background Chem 250 F 2008 Page 1 of 24

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Chapter 14. Molar Mass Distribution.

Interaction of Gold Nanoparticle with Proteins

Introduction. Chapter 1. Learning Objectives

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

High Performance Liquid Chromatography

Setting the Standard for GPC. Complete Guide for GPC / SEC / GFC Instrumentation and Detection Technologies. The Right Instrument for Your Application

Chromatography and Functional Group Analysis

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

GPC / SEC Theory and Understanding

CEE 697z Organic Compounds in Water and Wastewater

Cation Exchange HPLC Columns

Polymer Analysis by Gel Permeation Chromatography

Protein Synthetic Lipid Interactions

Differentiation of polymer branching and composition using the Mark Houwink plot

NAME IV. /22. I. MULTIPLE CHOICE. (48 points; 2 pts each) Choose the BEST answer to the question by circling the appropriate letter.

Glyphosate in all its forms

Sample characterization: Quality control and sample handling prior to data collection

Chromatography. Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

Sample preparation and characterization around SAXS

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

Polymers Reactions and Polymers Production (3 rd cycle)

Bis sulfone Reagents. Figure 1.

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

CHAPTER 6 GAS CHROMATOGRAPHY

Kang, Lin-Woo, Ph.D. Professor Department of Biological Sciences Konkuk University Seoul, Korea nd Semester

GPC/SEC Troubleshooting Volume 1

Latest Developments in GPC Analysis of Adhesive and Sealant Polymers Mark Pothecary PhD Americas Product Manager Malvern Instruments

MODERN HPLC FOR PRACTICING SCIENTISTS

The ph-responsive behaviour of aqueous solutions of poly(acrylic acid) is dependent on molar mass

Features or compounds? A data reduction strategy for untargeted metabolomics to generate meaningful data

Effects of Secondary Interactions in Size Exclusion Chromatography

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Luminescence transitions. Fluorescence spectroscopy

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

OVERVIEW INTRODUCTION

Shodex TM ODP2 HP series columns

Chromatography and other Separation Methods

LS Spectrometer. The DLS and SLS system for sophisticated research

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Transcription:

Tips & Tricks GPC/SEC: Protein Analysis with Size-Exclusion Chromatography Daniela Held and Thorsten Hofe, PSS Polymer Standards Service GmbH, Mainz, Germany Gel permeation chromatography/size-exclusion chromatography (GPC/SEC) is the standard method to separate samples by molecular size. In protein analysis, size-exclusion chromatography is either applied to detect and quantify aggregation, or to measure the complete molar mass distribution. However, method development is not trivial and the choice of suitable detection options is crucial. Photo Credit: -strizh-/shutterstock.com In contrast to synthetic macromolecules and the majority of biopolymers, most proteins do not exhibit a molar mass distribution (1) but are uniform in molar mass. Nevertheless, fractionating techniques are useful for such monodisperse protein samples because they can identify or monitor potential aggregation. Traditionally size-exclusion chromatography (SEC) can be used to separate stable aggregates from monomers or fragments and, in combination with advanced detection such as light scattering (LS) or mass spectrometry (MS), also to determine their molar mass and size. For protein mixtures with a molar mass distribution (such as gelatins), gel permeation chromatography (GPC)/SEC is applied because it measures the complete molar mass distribution and gives access to a variety of quality (and safety) related results. A major challenge for GPC/SEC protein analysis is the development of a robust method that eliminates undesired interactions with the stationary phase present in the separation column. What are the Advantages and Limitations of GPC/SEC? A major advantage of GPC/SEC is that it is a nondestructive separation technique. It fractionates samples based on the sizes present. GPC/SEC is ideal for reducing the complexity of a sample before applying advanced detection techniques such as MS, LS, or viscometry. The reduction in complexity eases data evaluation and interpretation when compared to direct analysis of nonfractionated heterogeneous samples. Advanced detection can very often be used as an on-line method. If hyphenation is not applicable, GPC/SEC allows the sample fractions collected to be used for further characterization. 4 3

Figure 1: Chromatograms for different proteins and amino acids of different hydrophobicity showing the influence of the ionic strength on the obtained peaks (blue: low ionic strength, red: high ionic strength). In GPC/SEC proteins can be analyzed under native conditions in solution, which is favourable as conformations and protein protein interactions remain intact. Many GPC/SEC separations therefore preserve the biological activities of the macromolecules. On the downside, the conditions for true GPC/SEC separations those only based on the size of the protein in solution can be cumbersome to achieve. Interactions between the sample and the stationary phase are often encountered, resulting in unexpected peak shapes, unstable retention times, and poor recovery. As different proteins exhibit different shapes (for example, globular-, rod-like-, or flexible chains), their sizes in solution often do not correlate directly with molar mass, thereby facilitating the need for more advanced detection methods for molar masses. A thorough method development for protein analysis should comprise of selecting the right column (or column combination) with the matching stationary phase, particle size, and porosity, adjusting the ph and ionic strength of the mobile phase, and selecting the best detection option for a series of samples. An essential part is also evaluating the chromatographic recovery of all components and aggregates present in the sample. Pitfalls in Method Development Proteins need to be analyzed in aqueous solutions and are therefore a subcategory 19 4 3

Figure : Raw data and results for a UV-LS setup used to investigate protein aggregation. The red curve shows the concentration for monomer and dimer, while the dark red lines show the on-line measured molar mass at every elution volume. Figure 3: Overlay of the chromatograms of a monoclonal antibody (mab) (red, UV trace) and the fragments (blue, UV trace) measured on the same column set. of aqueous GPC/SEC. All general method development tips for GPC/SEC are applicable to protein method development as well. The influence of column dimensions, particle size, temperature, flow rate, and injected mass have been described in several GPC/SEC Tips & Tricks instalments ( 5). This article will therefore focus on the special requirements for proteins only. One advantage of proteins over synthetic polymers or large biomolecules is that proteins are usually small and the size distribution within a sample is relatively narrow. The chromatographic benefits of small particles can therefore be fully exploited. In addition, the narrow distribution means that columns with very flat calibration curves (high resolution in a narrow molar mass range) can be used. Silica-based GPC/SEC columns are therefore still preferred for most protein applications. A disadvantage of proteins from a chromatographic point of view is that they have a large number of functional or charged groups and may possess larger hydrophobic parts than other water-soluble macromolecules. These two characteristics make it difficult to develop a true GPC/SEC method with no (or at least minimized) electrostatic and hydrophobic interaction between the column stationary phase and the protein. Interaction can result in adsorption (reduced recovery, often no peaks detectable), shifted elution times (higher or lower elution volumes), or distorted peak shapes (tailing). To avoid or reduce interactions, the ph value, the ionic strength or salt content, and the use of potential organic modifiers need to be adjusted. However, the concentration of the salts or the modifier 0 4 3

added is limited because it also influences the solubility of the sample. If it is not possible to develop a stable GPC/SEC method a change of stationary phase (from the silica column to a polymer-based column) should be attempted. A good starting point for method development is running the protein at its isoelectric point (pi). The pi of a protein is the ph value at which positive and negative charges resulting from the different amino acids comprising the protein are balanced. Neither the positively charged ammonium nor the negatively charged carboxyl groups are dominating here. An ideal GPC/SEC method for every single protein would be run with an aqueous solution with a ph matching the pi. To avoid the cumbersome approach of having a method for every single protein, the ph of the mobile phases is chosen to be close to pi and additional polyelectrolytes monovalent salts, such as sodium chloride or potassium chloride, are added. The electrolyte will help to shield residual charges and reduce the undesired interaction between the proteins and the stationary phase. Another parameter to be considered is the hydrophobicity of the protein. The polarity of the different R groups in the protein is important. Based on the R group an amino acid can be classified as charged, hydrophilic, or hydrophobic. Proteins containing many hydrophobic amino acids, such as leucine, alanine, and valine, are rather hydrophobic and cannot be analyzed under the same conditions as hydrophilic or charged proteins containing amino acids, such as serine, arginine, or histidine. Figure 1 compares the influence of the ionic strength on the chromatograms of proteins with different hydrophobicity. A hydrophilic protein such as chymotrypsinogen A should be measured at high ionic strength; bovine serum albumin (BSA), a protein that is neither hydrophobic nor hydrophilic, can be measured at high and low ionic strengths; and hydrophobic amino acids such as alanine or substituted alanines should be analyzed at low ionic strengths. If the ionic strength is adjusted according to the polarity of the protein the separation will fail. Finally, it should be mentioned that unexpected peak shapes (for example, with tailing) have been shown to be the result of using standard liquid chromatography (LC) equipment and detector cells. To reduce metal protein adducts or undesired protein interactions 1 4 3

Figure 4: Overlay of the molar mass distributions of three different gelatins: silver 0 bloom (red), gold 0 bloom (green). and platinum 40 bloom (blue). it might be required to use bio-inert or biocompatible chromatographic systems and column hardware. Such systems are also of advantage when harsh conditions are applied, such as extreme ph-values or high salt content. Bacteriocides or bacteriostats can help to overcome bacterial contamination. Without this algae growth can occur in aqueous mobile phases within a few hours and may cause severe problems. Detection Options Proteins can be detected using UV detectors. This is highly convenient because UV detectors are easy to use, linear in response over a wide range, and sensitive and baseline stable. Each UV wavelength range has its advantages: 80 nm is very often selected as a standard wavelength. Near UV or longer wavelengths (380 315 nm) detect aromatic amino acids, such as tryptophan. Higher sensitivity is provided by selecting a wavelength in the far UV range (80 00 nm) at low wavelengths such as 0 nm, where the amide peptide bond has a strong absorbance. There are also many setups where two different wavelengths are recorded simultaneously to measure the protein concentration. The combination of this dual-wavelength detection approach has been proposed for purity investigations, where the lower wavelength provides the sensitivity for the low abundant species, while the higher wavelength provides a higher linear range for the major species (the monomer, for example) (6). To overcome the limitation of size-based GPC/SEC separations, either MS or LS detection can be used to determine the molar mass directly. Both methods should be understood as complementary techniques because they offer solutions in completely different application fields. MS is very strong when it is required to determine very specific details about a limited number of individual species of not too high molar mass. MS is by far the most precise and accurate way to determine molar masses. However, when sample complexity and molar masses increase, the density of the resulting mass spectrum makes it very often impossible to interpret the data and assign the results. Fortunately, in these cases LS can be used because this technique is well suited for analyzing polydisperse high molar mass samples. Another advantage is that LS is very sensitive to high molar masses, even at low concentrations. LS can often detect higher aggregates with higher sensitivity than any other detector. The greatest challenge when hyphenating GPC/SEC with MS is the composition of the required mobile phase. Mobile phases in GPC/SEC often contain high concentrations of nonvolatile, MS-incompatible salts, which can lead to problems with contamination of the mass spectrometer and ion suppression. A hyphenated approach is therefore much easier to achieve with LS. There is no need to evaporate the mobile phase. An additional advantage is that for LS detection, structure information is still available, which would be lost with MS detection when the proteins are ionized and vaporized. There are many LS detectors on the market and they mainly differ by the number of angles that simultaneously acquire the scattering intensities (7). The majority of globular proteins are so small in dimension that 90 light scattering is fully sufficient to measure the molar mass. Unfortunately, this also means that it is not possible to measure the size (radius of gyration) with multi-angle light scattering detection (MALLS) for many proteins. Other techniques, such as dynamic light scattering (DLS, also known as QUELS) for measuring the hydrodynamic radius (Rh), must be applied. 4 3

The most common detector in GPC/SEC for synthetic polymers, the refractive index detector (RI), is also used for protein analysis. However, an RI detector is mainly used in combination with a LS detector because it can determine the refractive index increment, dn/dc, on-line. This sample-related parameter strongly influences the accuracy of light scattering results. It depends on many experimental settings including the LS detector wavelength and the solvent for example. Often an averaged dn/dc of 0.5 ml/g is applied for all proteins, however, care should be taken here because the dn/dc can vary significantly with the protein type (8). All other GPC/SEC detection options can be used. Some proteins can be analyzed with fluorescence detectors with an improved sensitivity and selectivity. Viscometers are becoming more and more common to distinguish between denaturation and aggregation. They can detect density differences and help to identify structure changes. The multidetection approach is already common for the GPC/SEC analysis of synthetic polymers, and is becoming more popular for protein analysis. How Do the Results Look? Figure shows the raw data and results for a UV-LS setup used to investigate protein aggregation. The combined analysis of UV trace and light scattering trace gives direct access to the molar masses of dimer and monomer without column calibration. As the obtained molar mass of the early eluting smaller peak is approximately twice the molar mass of the later eluting larger peak, this is an indication of dimerization. Analyzing the peak areas of the UV trace allows the dimer content to be determined to around %. Figure 3 shows an overlay of the chromatograms obtained for a full length monoclonal antibody (mab) and antibody fragments analyzed on the same set of columns. The red curve shows the UV signal of the full length antibody and its dimers, while the blue curve shows the UV signal of antibody fragments and their high level aggregates. Figure 4 shows the results for a protein exhibiting a molar mass distribution. In the overlay three different gelatins can be clearly differentiated, the molar mass averages and the molar mass distribution can be easily determined. Summary t (1$4&$JTBQPXFSGVMUFDIOJRVFUP investigate protein aggregation. It can separate proteins under native conditions based on their sizes in solution. t 4J[FCBTFETFQBSBUJPODPOEJUJPOT typically require mobile phases with adjusted ionic strengths. Method development should also include recovery investigations. t "EWBODFEEFUFDUJPOPQUJPOT.4PS LS as complementary techniques) can help to overcome GPC/SEC limitations and measure the molar masses directly. t 0UIFSUZQJDBM(1$4&$EFUFDUPSTTVDI as RI or a viscometer, can provide dn/dc (required for LS evaluation) or structural information. References 1. D. Held, The Column 3(8), 3 4 (007).. D. Held, The Column 9(6), 9 1 (013). 3. D. Held, The Column 8(), 8 11 (01). 4. D. Held, The Column 7(), 16 (011). 5. T. Hofe and D. Held, The Column 5(6), 9 1 (009). 6. M.D. Bond, M.E. Panek, Z. Zhang, et al., J. Pharm. Sci. 99(6), 58 97 (0). 7. D. Held and P. Kilz, The Column 5(4), 8 3 (009). 8. H. Zhao, P.H. Brown, and P. Schuck, Biophys. J. 0(9), 9 17 (011). Daniela Held studied polymer chemistry in Mainz, Germany, and works in the PSS software and instrument department. She is also responsible for education and customer training. Thorsten Hofe studied chemistry in Mainz, Germany, and Toronto, Canada. He is the head of the PSS production department (columns, reference material, and polymer synthesis). He is also involved in education and customer training. E-mail: Website: DHeld@pss-polymer.com www.pss-polymer.com 3 4 3