DYNAMIC SORPTION. Dynamic Sorption Breakthrough Analyzer. Gas Purification

Similar documents
DYNAMIC SORPTION. Dynamic Sorption Breakthrough Analyzer. Gas Purification. Ceramics. Energy. Carbons. Pharma

Water & Vapor Sorption

Water & Vapor Sorption

VersaWin. Gas Sorption Data Reduction Software

ChemStar. ChemStar TPx. TPx. Catalysts. Ceramics. Energy. Carbons. Zeolites. Polymers. chemisorption analyzer

VersaWin DA DR DH HK QSDFT SF. Gas Sorption Software

Chemisorption Analyzer. ChemStar TPx. Catalysts. Ceramics. Energy. Carbons. Zeolites. Polymers Quantachrome Corporation Rev.

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

High-Pressure Volumetric Analyzer

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

autosorb automated gas sorption analyzer surface area, pore size, chemisorption

Perseverance. Experimentation. Knowledge.

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

AutoChem II 2920 A Catalyst Characterization Laboratory

XEMIS NEXT GENERATION GRAVIMETRIC SORPTION ANALYZER

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

The Vacuum Sorption Solution

autosorb automated gas sorption analyzer

evo=evolution QUADRASORB evo Surface Area & Pore Size surface area & pore size analyzer Catalysts Ceramics Energy Carbon Pharma

Investigation of Mixed Gas Sorption in Lab-Scale. Dr. Andreas Möller

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

Your partner in Science!

autosorb automated gas sorption analyzer

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

AutoChem II 2920 The Cayalyst Characterization Laboratory

Compact Orifice FlowMeter

Porous Solids for Biogas Upgrading

C80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group

Adsorption of Polar and Nonpolar Vapors on Selected Adsorbents: Breakthrough Curves and their Simulation

surface area & pore size analyzer GAS SORPTION Catalysts Ceramics Energy Carbons Zeolites Pharma

surface area & pore size analyzer GAS SORPTION Catalysts Ceramics Energy Carbons Zeolites Pharma 2014 Quantachrome Corporation Rev 1

Adsorption Processes. Ali Ahmadpour Chemical Eng. Dept. Ferdowsi University of Mashhad

High Pressure Chemistry. Hydrogenation & Catalysis Tools.

Characterizing Today s Materials Discovering Tomorrow s Welcome

Rapid Catalyst Screening Reactors

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

IRMS. perspective. Isotope Ratio Mass Spectrometry.

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Ultrasonic Gas Flow Meter

Simply Better Pipetting

TGA Thermal Gravimetric Analysis

Gravimetric Analysers for the Characterisation of the Sorption Properties of Materials.

ICP-MS. High Resolution ICP-MS.

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

473-SHX Dew Point Mirror

Novel Zeolite Adsorbents

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

MARINELLI BEAKERS CATALOG

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Noble Gas Control Room Accident Filtration System for Severe Accident Conditions (N-CRAFT)

Fusion UV/Persulfate TOC Analyzer

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

Adsorption (Ch 12) - mass transfer to an interface

Possibilities and Limits for the Determination of. Adsorption Data Pure Gases and Gas Mixtures

DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System

Thermo Finnigan LTQ. Specifications

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

Supporting Information

QDTL. Liquid Mass Transfer and Diffusion Coefficient Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

STATE-OF-THE-ART ZEOLITE CHARACTERIZATION: ARGON ADSORPTION AT 87.3 K AND NONLOCAL DENSITY FUNCTIONAL THEORY (NLDFT)

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

Coflore Agitated Cell Reactor

ION CHROMATOGRAPHY SYSTEM S 150

Hiden Isochema IMI Series. Manometric Gas Sorption Analyzers.

Pressure Swing Adsorption: A Gas Separation & Purification Process

University Wet Chemistry Analyzer Packages

FT-ICR Mass Spectrometer QUANTRA. Technical Description September quantra

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Simply better pipetting!

Dynamic simulation of DH house stations

473 Dew Point Hygrometer

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Building multiple adsorption sites in porous polymer networks for carbon capture applications

Lecture 7. Sorption-Separation Equipment

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

costech instruments ECS 4010 Elemental Combustion System CHNS-O

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Kjeltec 2300 Analyzer Unit

Hiden HPR60 Molecular Beam Mass Spectrometer System

MM 2. Innovation with Integrity. The new Generation of Mobile Mass Spectrometers. Defence CBRNE

How do you explain HPLC? 2 AZURA Educational System for tomorrow s HPLC professionals

calorimeter heat flow calorimetry, power compensation calorimetry

Freezing point osmometry

Mining Analyzer XRF-3360

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

High Pressure DSC Differential Scanning Calorimeter

ISEmax CAM40/CAS40. Technical Information

473 Dew Point Hygrometer

Mining Analyzer XRF-3360

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

UDK. Distillation Units Series. A Full Range of Solutions for Kjeldahl Distillation LABSOLUTIONS

Transcription:

Dynamic Sorption Breakthrough Analyzer Gas Separation Breakthrough Curves Industrial Adsorbents Multi Component Adsorption Material Research Energy Chemical Engineering Energy Storage Gas Storage Carbons Separation Technologies Environmental Zeolites 2016 Quantachrome Corporation 0516 07121 Rev 2

dynasorb OVERVIEW INTRODUCTION Industrial adsorbents such as active carbons, zeolites and silica gels are widely used in adsorptive separation processes on a multi-ton scale. The after-treatment of exhaust gasses, the removal of carbon dioxide in biogas plants, purification and fractionation of natural gas, air separation, respiratory protection and separation of isomers are just a few examples where adsorptive separation is employed as the most efficient and economic separation technique. A complete understanding of the complex processes taking place in a fixed bed reactor is the key to achieving the best separation performance. The dynasorb BT series provides unique capabilities to investigate complex dynamic sorption processes in a uniquely safe and easy-to-use bench-top instrument. Industrial adsorbents can be investigated under authentic process conditions in a broad temperature and pressure range with adjustable gas flow rates and well-defined gas compositions. ADSORBER The stainless-steel adsorber can accommodate representative sample amounts (up to 100 ml) to simulate an authentic fixed bed adsorber with realistic gas flow conditions. Four temperature sensors along the adsorber axis monitor the release/consumption and propagation of heat within the fixed bed due to adsorption/desorption of gas molecules. The direction of gas flow through the adsorber can be switched between up- and down-stream to allow investigation of bed regeneration, adsorption-desorption cycles, and long-term stability of the adsorbent. Sample preparation can be performed in-situ using either inert gas flux or vacuum at temperatures up to 400 C. Regulating the temperature of the inlet gas and the adsorber allows for uncompromised temperature control throughout the measurement. High precision mass flow controllers are used for quick and stable gas mixing and flow rate control. The adsorber pressure is regulated automatically up to 10 bar and a differential pressure detector monitors the pressure drop between adsorber inlet and outlet. Determination of breakthrough curves Gas Separation Investigation of kinetic performance of adsorbents Investigation of co-adsorption and displacement phenomena a b d Determination of sorption selectivity Reasonable downscaling of industrial separation processes c e Energy Dynamic adsorption and desorption experiments Determination of single- and multi-component adsorption data Investigation of heat profiles along the adsorber bed Carbon Measurement of adsorption in the presence of water or others vapors a b Adsorber pressure Intelligent lighting c Adsorber with four(4) temperature sensors d TCD bypass valve Zeolites e Up to four(4) gas input and one(1) vent output 1

dynasorb OVERVIEW SAFETY A robust adsorber design, protective doors, an illuminated working area, and a clearly structured PC-control interface assure a safe and convenient instrument operation. The adsorber pressure is continuously measured and displayed on the front of the instrument, even if the instrument is turned off. Work area illumination changes from white to red when the heating mantle temperature exceeds 80oC, indicating an elevated temperature in the work area. Safety guard sensors for the detection of flammable gasses are standard in all dynasorb BT instruments. In the event of a gas leakage the instrument is brought to an idle state and shut off automatically. SIGNAL DETECTION The adsorber outlet gas composition is measured with a built-in Thermal Conductivity Detector (TCD) situated in a thermostatted environment for most precise and stable signal detection. The TCD is pre-calibrated by the manufacturer for 13 common gas mixtures. You are working with a different system? No problem! Due to fully automated bypass calibration, almost any binary mixture can be detected. The additional mass spectrometer control capability allows for the quick and easy interfacing of an optional mass spectrometer. FEATURES Easy and intuitive PC-control Automated processing of sequential adsorption and desorption experiments In-situ sample preparation Countercurrent gas flow capability Automated regulation of the adsorber pressure up to 10 bar Up to 4 high precision mass flow controllers Automated built-in gas mixing Evaporator option for introduction of water and other vapors Measurement of inlet and outlet gas composition Temperature control of inlet gas and adsorber Determination of heat profiles within the adsorber bed with four temperature sensors Monitoring of pressure drop along the adsorber Built-in thermal conductivity detector (TCD) Optional gas analysis via interfaced Mass Spectrometer Safety guard sensor for flammable gases for automatic shut down Enhanced Safety by intelligent illuminated workspace Characterizing Today's Materials Discovering Tomorrow's Zeolites Carbon Energy Gas Separation 2

BENEFITS Gas Separation Large Flow Range Investigation of mixture equilibrium and kinetics, downscaling of industrial processes. Temperature Regulated Inlet Gas and Adsorber For uncompromised temperature control during the measurement. Built-in Sample Preparation Up to 400 C Investigation of hydrophilic materials (i.e., Zeolites and silica gels). Linear Heating Rates Up to 10 K/min Slow and controlled heating of sensitive materials. Automated Gas Mixing No need for multiple pre-mixed gas tanks, increasing flexibility of measurement conditions. Automated Counter Current Operation Downscaling industrial PSA-processes. PC Control and Data Acquisition Completely programmable for operator-free analysis. Four Temperature Sensors in Column Monitoring of heating profiles during adsorption and desorption processes. Differential Pressure Sensor Observation of pressure drop in the column. Built-in Thermal Conductivity Detector (TCD) Automated time-resolved measurement of outlet gas composition. Bypass Connection Measurement of inlet gas composition before analysis. Automated Pressure Regulation Completely programmable for operator-free performing of pressure steps. Optional Gas Analysis via Interfaced MS Investigation of ternary and more complex systems. Battery-Backed Pressure Display Monitoring of column pressure, even when power is off. Safety Guard Sensor Automatic shut down and warning in PC software after reaching 1% C x H y in manifold (i.e., caused by leaks). Switching Illumination Light in working area switched from white to red, if the column temperature is above 80 C (preventing of accidental contact with hot surfaces). Energy SPECIFICATIONS Adsorber 1 Number of mass flow controllers 1 2 standard, 3 or 4 optional Max. pressure [bar] 10 Sample preparation in-situ Temperature range heating mantle ambient to 400 C Carbon Temperature range circulator bath -20 C to 90 C Height 80 cm (31.5 in) Width 95 cm (37.5 in) Zeolites 3 Depth Weight (approximate) 60 cm (23.5 in) 200kg (440 lbs) 1 Mass flow controllers are available in different ranges (0.1, 0.2, 0.5, 1, 2, 5, 10, 20 L/min) for optimal instrument configuration with respect to customer s needs.

SOFTWARE dynawin The user-friendly control software dynawin provides real-time control and programmable operation of all system functions, such as gas flow rates and gas compositions, flow paths and direction of flow, temperature ramps and dwell times, etc. The Software assists the user in the configuration of complex adsorption and desorption sequences. Analysis sequences can be processed fully automated and unattended. The definition of intelligent start/stop criteria provides unprecedented flexibility and facilitates a most efficient and economic operation (conserving gas usage). Further software features are: Real-time data presentation Manual mode control Demo mode for operator training and education Historical data trending System alarm settings User account management (hierarchy of user access levels) Well-structured log files Auto-save function The status of all sensors and valves, the path and direction of gas flow, and all relevant system information for safe and convenient operation can be viewed at a glance on the controlling PC. dynasim The Included simulation software dynasim provides sophisticated data reduction and simulation capabilities, such as: Integration of breakthrough curves Comprehensive parameter studies Simulation and prediction of breakthrough behavior and heat profiles Calculation of single- and multi-component adsorption data Determination of selectivity, affinity, and kinetic coefficients Complex calculations or basic research, dynasim accommodates it all, making it a powerful tool for both industry and academia. Contact your local representative or call 1.800.989.2476 (in USA/Canada) to request pricing information. 4 Zeolites Carbon Energy Gas Separation

SOFTWARE Comparison of a measured breakthrough curve (red) with the simulated breakthrough behavior (blue) computed with dynasim. Integration of consecutive adsorption-desorption cycles. Calculated multi-component sorption equilibria. A typical breakthrough curve (red) with the corresponding temperature signal (black) measured at the bottom of the adsorber bed. Gas Separation Energy Carbon Breakthrough curves of a binary gas mixture in helium carrier gas. Zeolites 5 Calculated multi-component sorption equilibria showing total loading (yellow) and partial loading (red and blue).

CUSTOMIZED AND FLEXIBLE Customized The number and range of mass flow controllers is determined by the customer s needs. Mass flow controllers are available in different flow ranges 0.1, 0.2, 0.5, 1, 2, 5, 10, 20 L/min). With respect to the application, a suitable set of up to four MFC s can be configured for optimal experimentation. Flexible: The number and range of MFC s can be changed at any time in field up-grades. Several options and accessories are available for further customizing dynasorb BT analyzers for individual needs and applications. Alternative Adsorber Sizes The standard adsorber is 3 cm in diameter and 18 cm in length for the investigation of representative sample amounts of about 100 ml. Four temperature sensors measure the evolution and propagation of heat profiles along the adsorber axis. Alternative adsorber sizes are available to investigate smaller sample amounts. Circulator Option A single circulating bath can be used for the precise temperature control of the inlet gas and the adsorber between -20 C and 90 C. Beaker Option The Beaker Option gives the user the opportunity to regulate the temperature of the adsorber column. The configuration, installed options, and current status of the system are visible at a glance on the main display. Optional Mass Spectrometer With the Mass Spectrometer Option, a Pfeiffer mass spectrometer (ThermoStar or OmniStar ) can be controlled by the dynawin software. Controlling includes turning the filaments on/off and starting/stopping data acquisition with the Pfeiffer QUADERA Software. Optional Mass Flowmeter A Mass Flowmeter can be included in the manifold to measure the mass flow after the adsorber column. Since, prior to 100% breakthrough the mass flow entering the column can be different from flow coming out, especially in high concentrations, measuring the actual flow allows the software to compensate for the difference. Vacuum Option With the Vacuum-Option, a vacuum pump can be connected to the instrument. The software allows the activation of the pump to evacuate the manifold and the adsorber column during pretreatments or analyses. In addition to a more effective sample pretreatment, this option will allow the emulation of a VPSA-process (Vacuum-Pressure Swing-Adsorption) with one adsorber column. Evaporator Option This option injects a liquid into a flash evaporator which is then mixed with a carrier gas stream, introducing a vapor at controlled concentration. This allows the evaluation of the adsorption charateristics of an adsorbent in the presence of a vapor (e.g. water) or the separation of the vapor from a gas. Zeolites Carbon Energy Gas Separation 6

For almost half a century Quantachrome s scientists and engineers have revolutionized measurement techniques and designed instrumentation to enable the accurate, precise, and reliable characterization of powdered and porous materials. We have an unwavering commitment to providing state of the art technology, along with superior and unparalleled customer service and support. Our commitment to customers is to support you before, during, and after the sale throughout the lifetime of our instruments. This is a big commitment because our products are so robust and reliable that we regularly find many still in use for decades. Renowned innovator for today s porous materials community. Quality Function Dependability The quality of Quantachrome s after sales service support is the reason we are proud to maintain life time relationships with our customers. Field Service Spare Parts Application Lab Lifetime Application Support Our global service staff assure you that Quantachrome Instruments will continue to be the reliable engines of material characterization laboratories. We offer you the flexibility of choosing from service contracts tailored to provide you with the response time, service package, and spare parts discounts that best fit your needs. Quantachrome spare parts are certified to work with our instruments. We provide rapid response spare parts orders, and keep large inventories of replacement parts and hardware available. Our fully equipped, state-of-the-art powder characterization laboratory, LabQMC (www.labqmc.quantachrome.com, qc.lab@quantachrome.com), provides the option of contracting for expert testing services. Laboratory services are also available to validate the applicability of our products prior to your purchase using your actual samples. We view the field support of our instruments as an essential component of our business strategy. Our expert scientists are always available to answer questions on applications, or the use of our instruments. We do this as a standard service regardless of whether you have a service contract with us or not. Corporate Headquarters-USA Quantachrome Instruments 1900 Corporate Drive Boynton Beach, FL 33426 Tel: + 1 800. 989 2476 + 1 561. 731.4999 Fax: + 1 561. 732.9888 email: qc.sales@quantachrome.com www.quantachrome.com China Quantachrome Representative Office www.quantachrome.com.cn email: order.china@quantachrome.com Tel: 400.650.1652 + 86.21.528 28278 United Kingdom Quantachrome UK Ltd. www.quantachrome.co.uk email: info@quantachrome.co.uk Tel: + 44 (0) 1252 819 719 Germany Quantachrome GmbH & Co. KG www.quantachrome.de email: info@quantachrome.de Tel: + 49 (0) 8134 93240 Japan Quantachrome Instruments Japan G.K. www.quantachrome.co.jp email: sales.japan@quantachrome.com Tel: 044.829.1525 India Quantachrome India www.quantachrome.com email: pankajkadam@quantachromeindia.in Tel: + 91 22 2589 5858 Your local Representative: Partners in Science Quantachrome has a scientific research department who are world renowned experts in material characterization. Our staff, led by Dr. Matthias Thommes, conduct collaborative research projects with leading material research labs around the world. They regularly publish articles in leading peer reviewed journals, and speak at technical symposiums around the world. Trademarks and registered trade mark are the property of their respective owners. 2016 Quantachrome Corporation 0516 07121 Rev. 2 Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability