Strain gauge measurement uncertainties on hydraulic turbine runner blade

Similar documents
Available online at ScienceDirect. Procedia Engineering 133 (2015 ) th Fatigue Design conference, Fatigue Design 2015

Efficient runner safety assessment during early design phase and root cause analysis

What is a Strain Gauge? Strain Gauge. Schematic View Of Strain Gauge

Numerical simulation of pressure pulsations in Francis turbines

Investigation on fluid added mass effect in the modal response of a pump-turbine runner

Strain Measurement on Composites: Errors due to Rosette Misalignment

CFD configurations for hydraulic turbine startup

Computational Simulation of Dynamic Response of Vehicle Tatra T815 and the Ground

Averaging effects of a strain gage

Effect of Plasticity on Residual Stresses Obtained by the Incremental Hole-drilling Method with 3D FEM Modelling

Self-weight loading of horizontal hydraulic cylinders with axial load

Heat transfer coefficient distribution over the inconel plate cooled from high temperature by the array of water jets

Effect of Specimen Dimensions on Flexural Modulus in a 3-Point Bending Test

The influence of disc friction losses and labyrinth losses on efficiency of high head Francis turbine

The stiffness tailoring of megawatt wind turbine

Analysis of flow characteristics of a cam rotor pump

Damping of materials and members in structures

Excerpt from the Proceedings of the COMSOL Conference 2010 Boston

Fatigue Crack Analysis on the Bracket of Sanding Nozzle of CRH5 EMU Bogie

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

CFD evaluation of added damping due to fluid flow over a hydroelectric turbine blade

Application of the Shannon-Kotelnik theorem on the vortex structures identification

Deflections and Strains in Cracked Shafts due to Rotating Loads: A Numerical and Experimental Analysis

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 9

Validation of simulation strategies for the flow in a model propeller turbine during a runaway event

Natural frequency analysis of fluid-conveying pipes in the ADINA system

A HIGHER-ORDER BEAM THEORY FOR COMPOSITE BOX BEAMS

PLEASURE VESSEL VIBRATION AND NOISE FINITE ELEMENT ANALYSIS

Flow behaviour analysis of reversible pumpturbine in "S" characteristic operating zone

AE3610 Experiments in Fluid and Solid Mechanics TRANSIENT MEASUREMENTS OF HOOP STRESSES FOR A THIN-WALL PRESSURE VESSEL

Slide 1. Temperatures Light (Optoelectronics) Magnetic Fields Strain Pressure Displacement and Rotation Acceleration Electronic Sensors

Resolution of tower shadow models for downwind mounted rotors and its effects on the blade fatigue

Study of the influence of heat transfer of a CLT beam through FEM

Implementation of an advanced beam model in BHawC

Errors Due to Transverse Sensitivity in Strain Gages

Finite Element Simulation of Eddy-Current Flaw Detection Systems

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

3-D Finite Element Modelling of a High Pressure Strain Gauge Pressure Transducer. M. H. Orhan*, Ç. Doğan*, H. Kocabaş**, G.

Bending Load & Calibration Module

Analysis of the Impact of Major Influencing Factors on the Waveform of the Surface Eddy Current Probe for Electroconductive Nonmagnetic Pipe Thickness

NUMERICAL AND EXPERIMENTAL METHOD TO ALIGN 2500 TF PRESS COLUMNS

Experimental and Finite Element Analysis of a T-Joint Welding

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

Effect of magnetostrictive material layer on the stress and deformation behaviour of laminated structure

Sensors, Signals and Noise 1 COURSE OUTLINE. Introduction Signals and Noise Filtering Sensors: Strain Gauges. Signal Recovery, 2017/2018 Strain Gauges

Coupled vibration study of the blade of the flexible wind wheel with the low-speed shafting

Iraq Ref. & Air. Cond. Dept/ Technical College / Kirkuk

Modal Based Fatigue Monitoring of Steel Structures

Study on the natural air cooling design of electronic equipment casings: Effects of the height and size of outlet vent on the flow resistances

Reliability analysis of different structure parameters of PCBA under drop impact

Self Field Measurements by Hall Sensors on the SeCRETS Long Sample CICCs in SULTAN

MICROMECHANICAL ANALYSIS OF FRP COMPOSITES SUBJECTED TO LONGITUDINAL LOADING

Load Cell Design Using COMSOL Multiphysics

Stress and Displacement Analysis of a Rectangular Plate with Central Elliptical Hole

6 th Pipeline Technology Conference 2011

Theoretical Manual Theoretical background to the Strand7 finite element analysis system

Identification of welding residual stress of buttwelded plate using the boundary element inverse analysis with Tikhonov's regularization

Strain Gages. Approximate Elastic Constants (from University Physics, Sears Zemansky, and Young, Reading, MA, 1979

Design and Development of Impact Load Sensor for Dynamic Testing Purposes

Chapter 5 Structural Elements: The truss & beam elements

Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

Indentation tests of aluminium honeycombs

ARTICLE A-8000 STRESSES IN PERFORATED FLAT PLATES

FIELD INSTRUMENTATION AND ANALYSIS OF PROTOTYPE AND EXISTING LIGHT POLES ON THE BRONX-WHITESTONE BRIDGE. Final Report. Ian C. Hodgson.

ROTATING RING. Volume of small element = Rdθbt if weight density of ring = ρ weight of small element = ρrbtdθ. Figure 1 Rotating ring

Schur decomposition in the scaled boundary finite element method in elastostatics

Investigation of Bucket Wheel Excavator Lattice Structure Internal Stress in Harsh Environment through a Remote Measurement System

A Simplified Eigenstrain Approach for Determination of Sub-surface Triaxial Residual Stress in Welds

MENG 302L Lab 6: Stress Concentration

Metrological Characterization of Hardness Indenter Calibration System

Propagation of Uncertainty in Stress Estimation in Turbine Engine Blades

QUESTION BANK Composite Materials

Chapter 2. Formulation of Finite Element Method by Variational Principle

ELECTRONIC SENSORS PREAMBLE. This note gives a brief introduction to sensors. The focus is. on sensor mechanisms. It describes in general terms how

Determination of power requirements for solid core pulp screen rotors

Burst Pressure Prediction of Multiple Cracks in Pipelines

Burst pressure estimation of reworked nozzle weld on spherical domes

Special edition paper

Predicting Fatigue Life with ANSYS Workbench

STRAIN ANALYSIS OF HDPE BUTT FUSION JOINT IN SIDE BEND TEST

The Strain Gauge. James K Beard, Ph.D. Rowan Hall Auditorium November 2, 2006

Lab Exercise #5: Tension and Bending with Strain Gages

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Force and Displacement Measurement

On propagation of Love waves in an infinite transversely isotropic poroelastic layer

Bending of Simply Supported Isotropic and Composite Laminate Plates

Strain Gage Calibration Factors for Constant Room Temperature Conditions. Gage Resistance, Gage Factor and Transverse Sensitivity Coefficient)

KINK BAND FORMATION OF FIBER REINFORCED POLYMER (FRP)

TOWARDS A VALIDATED PIPELINE DENT INTEGRITY ASSESSMENT MODEL

Development of high-efficiency Stirling cryocoolers for high temperature superconducting motors

Exact solutions to model surface and volume charge distributions

Study on the construction of the shaft used in naval propulsion

ANALYTICAL PENDULUM METHOD USED TO PREDICT THE ROLLOVER BEHAVIOR OF A BODY STRUCTURE

EFFECTS OF THERMAL STRESSES AND BOUNDARY CONDITIONS ON THE RESPONSE OF A RECTANGULAR ELASTIC BODY MADE OF FGM

Multi-Capacity Load Cell Concept

Finite Element Formulation for Prediction of Over-speed and burst-margin limits in Aero-engine disc

PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Data Logger V2. Instruction Manual

Fracture Test & Fracture Parameters of Self Compacting Concrete using ANSYS. Zeel Vashi 1,Megha Thomas 2 I. INTRODUCTION

Transcription:

IOP Conference Series: Earth and Environmental Science Strain gauge measurement uncertainties on hydraulic turbine runner blade To cite this article: J Arpin-Pont et al 2012 IOP Conf. Ser.: Earth Environ. Sci. 15 062042 View the article online for updates and enhancements. Related content - The role of high cycle fatigue (HCF) onset in Francis runner reliability M Gagnon, S A Tahan, P Bocher et al. - Evaluation of RSI-induced stresses in Francis runners U Seidel, B Hübner, J Löfflad et al. - Fatigue analyses of the prototype Francis runners based on site measurements and simulations X Huang, J Chamberland-Lauzon, C Oram et al. Recent citations - Fatigue life estimation of Francis turbines based on experimental strain measurements: Review of the actual data and future trends Alexandre Presas et al This content was downloaded from IP address 148.251.232.83 on 07/03/2019 at 13:47

Strain gauge measurement uncertainties on hydraulic turbine runner blade J Arpin-Pont 1, M Gagnon 1, S A Tahan 1, A Coutu 2 and D Thibault 3 1 Mechanical Engineering Department, École de technologie supérieure, 1100 Notre- Dame Street West, Montreal, QC H3C 1K3, Canada 2 ANDRITZ-Hydro LTÉE, 6100, Trans-Canada Highway, Pointe-Claire, QC H9R 1B9, Canada 3 Institut de recherche d Hydro-Québec (IREQ), 1800 Boul. Lionel Boulet, Varennes, QC J3X 1S1, Canada E-mail: jeremy.arpin-pont@gadz.org Abstract. Strains experimentally measured with strain gauges can differ from those evaluated using the Finite Element (FE) method. This difference is due mainly to the assumptions and uncertainties inherent to each method. To circumvent this difficulty, we developed a numerical method based on Monte Carlo simulations to evaluate measurement uncertainties produced by the behaviour of a unidirectional welded gauge, its position uncertainty and its integration effect. This numerical method uses the displacement fields of the studied part evaluated by an FE analysis. The paper presents a study case using in situ data measured on a hydraulic turbine runner. The FE analysis of the turbine runner blade was computed, and our numerical method used to evaluate uncertainties on strains measured at five locations with welded strain gauges. Then, measured strains and their uncertainty ranges are compared to the estimated strains. The uncertainty ranges obtained extended from 74 με to 165 με. Furthermore, the biases observed between the median of the uncertainty ranges and the FE strains varied from -36 to 36 με. Note that strain gauge measurement uncertainties depend mainly on displacement fields and gauge geometry. 1. Introduction In this paper, we introduce a numerical method to evaluate the uncertainties of strain measurements. Strains have a significant influence on mechanical analyses, such as lifetime estimation. Accurately determining strains and stresses is not as simple as it might seem. Experimental, analytical and numerical methods can be used to determine strain levels. Typical experimental methods involve the use of strain gauges to measure strains at specific locations on the surface of a part [1, 2]. In comparison, the Finite Element Method (FEM) is a numerical method used to estimate strain levels. Both methods have their respective simplifications which introduce uncertainties in the estimated strains. These uncertainties in turn can produce significant differences between the values estimated by FEM and those measured with strain gauges. The list of uncertainty sources is large, as shown in figure 1. In this paper, the uncertainties studied will be limited to the ones generated by the combination of the behavior of a welded gauge, its position uncertainty and its integration effect. The proposed numerical method incorporates Monte Carlo simulations to evaluate the extent of these uncertainties. For each Monte Carlo simulation, the displacement fields estimated with FEM are Published under licence by Ltd 1

used to evaluate the strain measured by a virtual welded gauge located on the Finite Element model, and accounting for the studied uncertainties. The distribution of these strains determines the uncertainty range at the target gauge location. Figure 1. Uncertainties from FEM and Strain Gauge Measures. Using the proposed methodology, the uncertainties of in situ data obtained on a hydraulic turbine runner were evaluated. The data from two runner blades instrumented with ten uniaxial welded strain gauges at five key locations were compared to the strains evaluated by FEM. To understand the differences observed between the two, we used our numerical method to estimate the uncertainty ranges around the estimated strains. For each gauge location, three strain values can be compared: the strain estimated by FEM at the target location, the strains of experimental measurements, and the strain distribution evaluated by virtual gauges placed on the FEM model and accounting for the studied uncertainties. Note that the proposed method is not specific to the sensor used, and could also be applied to other sensor geometries, types and other parts. This paper is structured as follows: first, a review of the studied measurement uncertainty sources is presented. Next, our numerical method is introduced, and is followed by its application on a hydraulic turbine runner blade. Finally, a discussion on the results of the study case and the parameters influencing the uncertainty ranges concludes the paper. 2. Gauge measurement uncertainties A bonded strain gauge is a sensor composed of an electrical wire forming grid lines on a matrix, as shown in figure 3. The electrical resistance of the wire is a function of its length, cross-sectional area and electrical resistivity. This type of gauge is glued directly on the part surface. When the part surface deforms, the gauge also deforms in the same manner; strain readings are obtained from the change in the electrical resistance of the electrical wire of the gauge due to its variations in length and crosssectional area. The relation between the measured strain and the electrical resistance can be approximated by equation (1), where Measured is the strain measured by the gauge following its longitudinal axis; K is the gauge factor (which is a function of the electrical wire material); and R and R are the resistance and the resistance variation of the electrical wire, respectively [2]. Measured 1 R (1) K R In his work, J. Pople [3] listed more than 70 uncertainty sources for strain gauge measurements. Most of them are linked to human factors, but others are inherent to the gauge technology. Uncertainties can be introduced during the positioning of the gauge at a target location, in which case the actual location might differ from the target location combined with an alignment error. Moreover, welded strain gauges behave differently from bonded strain gauges due to their construction. In this paper, the uncertainties produced by the gauge behavior, the location uncertainty which includes positioning and alignment errors, and the integration effect of a welded gauge are investigated. These 2

uncertainty sources are illustrated in figure 2. We consider the other uncertainty sources, presented in figure 1, as controlled or negligible. Figure 2. Definition of uncertainty sources: welded gauge behavior, location uncertainty (including positioning and alignment errors) and integration effect. A unidirectional welded gauge possesses three main components: a thin carrier plate, a bonded gauge and connection cables [4]. The bonded gauge is glued on the thin carrier plate, which is then spot-welded on its periphery to the part surface, as shown in figure 4. Therefore, we obtain the strain measured on the carrier plate rather than the strain from the part surface. Displacement fields on the carrier plate can differ significantly from displacement fields on the part surface, leading to difference in strains and stresses. In our study, the uncertainty generated by the intermediate carrier plate is based on an FEM analysis of the carrier plate from which the displacement fields are obtained as a function of the gauge location. Note that welded gauges are easy to install on the part surface, are ready to use directly after their placement, and can be used in high temperature environments, where glues are not suitable [5]. Figure 3. Bonded strain gauge. Figure 4. Welded strain gauge. Experimentally, welded gauges are however difficult to accurately position at a target location and along a specific orientation, which produces positioning uncertainties. The displacement fields need to be known in order to evaluate the influence of these uncertainties but displacement fields are difficult to assess experimentally. We count few studies which examine the influence of positioning uncertainties [6, 7]. It should be noted that for a bonded gauge, the error on the strain produced by a misalignment in a uniform biaxial strain field was determined by C. Perry in 1969 [8]. This error is a function of three parameters: the ratio of the maximum-to-minimum algebraic principal strain; the angle between the gauge longitudinal axis and the maximum principal strain axis; and the alignment error of the gauge. The method proposed by C. Perry [8] is well adapted to bonded strain gauges but does not account for the behavior of the intermediate carrier plate of welded gauges. The method we propose uses the displacement fields of the carrier plate estimated by FEM and accounts for the positioning uncertainties to evaluate the strain measured by the gauge. These displacement fields also allow the evaluation of the integration error of the gauge. A strain gauge does not measure the strain at its center, but integrates the strains under its active grid surface. Gafitanu and al. [9], and more recently, Younis and Kang [10], both developed different methods to evaluate this integration error. The error is a function of two factors: the size of the active grid of the gauge, and the strain gradient under the gauge, as shown in figure 5. According to Le Goër 3

and Avril [2] and Gafitanu and al. [9], the integration effect could generate a difference of 30% between the measured strain and the strain at the center point of the gauge. Figure 5. Influence of integration effect. It should be noted that these uncertainties depend on the displacement fields in the neighborhood of the target location and the gauge geometry. In our study, the gauge geometry is known from specifications while displacement fields are estimated using an FEM model. 3. Numerical model The numerical methodology developed in this study allows the estimation of the studied uncertainties using the displacement fields from the FEM. In our methodology, a Virtual Welded Gauge (VWG) is first generated numerically on the FEM surface. The VWG is positioned near the target location by accounting for positioning and alignment uncertainties. Since the accurate position of a gauge can be unknown during the experimental measurements, positioning uncertainties are generated using random distribution laws. These uncertainties determine an area around the target location in which the VWG can be positioned. From the position of the VWG, displacements at the welding points on the periphery of the carrier plate are obtained by the interpolation of the displacement fields of the FEM surface. At welding points, the displacements of the carrier plate are assumed to be the same as those on the FEM surface. From these imposed displacements, a 2D FEM analysis of the carrier plate is computed. The rectangular carrier plate is meshed with 4-node shell elements. Nodes are positioned at the welding points on which the displacements are imposed. Therefore, the displacement fields obtained on the carrier plate can be compared to the displacement fields of the FEM part surface, as shown in figure 6. In this figure, a VWG is located on the FEM surface with positioning and alignment errors. The longitudinal displacement field isolines (mm) of the FEM surface and of the welded gauge carrier plate are plotted. We notice that even if the displacement fields are similar on the left side of the carrier plate, significant discrepancies are observed on the right. These discrepancies then influence the reading of the carrier plate strain gauge. Figure 6. Virtual Welded Gauge created on an FEM part model surface. Positioning errors: 12 mm in longitudinal axis X ; 8 mm in tangential axis Y ; 6 angular. Longitudinal displacement fields UX are plotted as isodisplacement lines (mm). 4

Using the displacement fields of the carrier plate, the strain measured by the VWG is evaluated by taking into account the gauge integration effect. In this case, the integration method on the all filaments length developed by Gafitanu and al. [9] is used. In this method, the strain from each grid line of the gauge gl j is determined with equation (2), where L 0 and L are respectively the initial and final length of the grid line j. U 1 and U 2 are the displacement vectors at the extremity points 1 and 2 of the grid line j, as shown in figure 7. These displacements are interpolated from the displacement fields of the 2D FEM model of the carrier plate. The final strain VWG is estimated using equation (3), in which n is the number of grid lines of the gauge. Figure 7. Strain determination for each grid line of the gauge. gl j 1/2 2 2 L L L ( L 0 0 U2 X U1 X ) ( U2 Y U1 Y) L0 (2) L L L 0 0 0 n j 1 gl j VWG (3) Finally, Monte Carlo simulations are carried out to evaluate uncertainties. For each simulation, a VWG is generated next to the target location with random positioning uncertainties. The distribution of strains evaluated by the VWGs is computed and can be compared to the FEM strain at the target location, and to experimental values. Our assumption is that the difference observed between the median of the strain distribution obtained using our numerical method and the FEM strain at the target location can be assimilated to the bias observed between experimental measurements and original FEM analysis results. An overview of the methodology is presented in figure 8. The method incorporates the following assumptions. We assume that the uncertainties observed are only due to the welded gauge behavior, the positioning uncertainties and the integration effect. These three sources of uncertainties depend on the displacement fields in the neighborhood of the target location. These displacement fields are estimated by FEM. However, because of the inherent uncertainties on FEM (see figure 1), the results cannot be considered to be exactly representative of actual displacement fields. This is combined with the assumption that displacements at the welding points of the carrier plate can be interpolated linearly from the displacement fields of the FEM surface. The displacements at the end of the grid lines are also interpolated linearly from the displacement fields of the carrier plate. It is assumed that the strain is uniform along each individual grid line of the gauge. Finally, the bonded gauge location on the carrier plate is known and the positioning uncertainties of the bonded gauge on the carrier plate are considered negligible. n 5

Figure 8. Method presentation. 4. Study case The presented methodology was applied to experimental measurements made on a Francis hydraulic turbine runner. A total of ten (10) welded gauges were installed on two (2) blades. Each blade was instrumented at five (5) specific locations, as shown on the figure 9. At each location, strain distributions obtained with our numerical method are compared to FEM strain at the target location and experimental measurements. 6

Figure 9. Position of the gauges placed on the hydraulic turbine blade during measurements. The gauges used are referenced as HBW-35-250-6-UP (Hitec Products Inc.). The distribution laws used to generate positioning and alignment errors were the same for the five locations, and are presented in table 1. These random position laws were estimated from the results of a Reproducibility and Reliability analysis (R&R) realized on a similar runner. This analysis was conducted using several strain gauges repeatedly installed at specific locations, following the experimental conditions of our reference project. Each time a gauge was installed, its positioning errors were accurately measured, and the gauge was removed. The process was repeated until the parameters of the distribution of the positioning uncertainties could be estimated Table 1. Positioning uncertainty distribution laws used for the simulations. Uncertainty Distribution Parameters Position along target axis X (mm) Uniform [ -10; 10 ] Position along tangential axis Y (mm) Uniform [ -6; 6 ] Alignment angle ( ) Uniform [ -5; 5 ] Furthermore, sensibility analyses were carried out to determine the influences of the number of elements in the 2D FEM of the carrier plate and the Monte Carlo simulation number. Stability is obtained with 400 elements and 2x10 3 Monte Carlo simulations. For the study case, we meshed the carrier plate with 551 rectangular elements (30 nodes in length and 20 nodes in width of the carrier plate) and computed uncertainties using 5x10 3 Monte Carlo simulations. 5. Results The strain results obtained are shown in figure 10, with detailed results for each location in table 2. Figure 10. Strain distributions resulting from 5x10 3 Monte Carlo simulations and experimental strain ranges for each of the five locations. Strains are expressed relative to the FEM strain at the target location. 7

Location Table 2. Relative strain results. Numerical method strain results (Microstrain με) Median (Q 50% ) [Q 25% ; Q 75% ] (range ) Measurement (με) range [Min; Max] (range) [Min; Max] (range) 1 36 [21; 83] (62) [10; 172] (162) [-54; -6] (48) 2 4 [-27; 38] (65) [-64; 101] (165) [-38; 29] (67) 3-7 [-20; -2] (18) [-69; 5] (74) [-61; 125] (186) 4-27 [-46; -6] (40) [-81; 45] (126) [-225; -5] (220) 5-36 [-64; -7] (57) [-104; 38] (142) [-177; -79] (98) The relative strains represent the difference between the strains obtained and the expected strain from the FEM at the target location. The boxes represent the first and third quartile (Q 25% and Q 75% ) of the relative strain distribution obtained with our numerical method, the middle line is the median (Q 50% ), and whiskers extend to the extreme values. The measurement ranges are the interval formed by strains observed during measurements. Measured strains were established from three independent measurements made at similar operating conditions. We observe an offset between the calibration values of each measurement, which produces variations in measured strains. Moreover, for each location, two different blades were instrumented. The strain measurement ranges presented in this study include the variations observed between both blades and the three independent measurements. Their statistical distributions, however, have not been determined. 6. Discussion We observe three different result combinations. The first, observed at location 1, is that the strain distribution obtained with our numerical method and the experimental measure range do not overlap. At this location, the FEM strain estimated at the target location is outside the measurement range. The uncertainties estimated with our method cannot explain this difference. In this case, it is possible that assumptions on both FEM and experimental measurements are false. The second combination, observed at locations 2, 3 and 4, is that more than 50% of the strains obtained with our numerical method overlap with the experimental measurement range. For location 4, the FEM strain at the target location is out of the experimental strain range, but the strain distribution estimate with our numerical method cover both the initial FEM results and part of the measurement range. Thus, the studied uncertainties could be considered as a cause of the differences between the FEM strain and experimental strains. A third possibility is observed for location 5. For this gauge, only a small part of the strains estimated with our numerical method overlap with the measurement range. The difference between the FEM strain at the target location and the nearest measured strain is 79 με. We observe that the strain distribution obtained with the numerical method, including the calculated uncertainties, shifted to the same side as the experimental measurements, which can only partially explain the differences observed between FEM and experimental strains. Strain distributions estimated by the virtual welded gauges are directly dependent on the FEM displacement fields around the target location. The geometry of the welded gauge, including the sizes of the carrier plate and of the bonded gauge, are determinant factors in the estimation of the welded gauge behavior error and the integration error. The random distribution laws used to generate the positions of virtual welded gauges are also important due to the importance of the FEM displacement fields. Uncertainty ranges obtained in this study case vary from 74 to 165 με for locations 3 and 2, respectively. The biases of the relative strains obtained vary from -36 to 36 με for locations 5 and 1, 8

respectively. Results are specific to each location and the numerical method has to be applied at each location independently in order to estimate the measurement uncertainties. 7. Conclusions In this paper, we have presented a numerical method, which enables the estimation of measurement uncertainties due to welded gauge behavior, positioning uncertainties and integration effect in strain measurement with welded strain gauges. In this method, the uncertainty ranges are estimated using the part surface displacement fields evaluated with an FEM analysis. Using these displacement fields, Monte Carlo simulations are carried out to estimate the distribution of strains estimated by virtual welded gauges randomly placed in the neighborhood of the target location on the FEM surface. The obtained distribution allows the estimation of the measurement uncertainty ranges. When applied to in situ measurements carried out on hydraulic turbine runner blades, uncertainty ranges obtained extend from 74 to 165 με, while biases vary from -36 με to 36 με. We observe that in some cases, the differences between experimental measured strains and strains evaluated by FEM cannot be explained by our simulation results. In these cases, we consider that the observed differences are due to the assumptions of both FEM analysis and experimental measurements. In most cases, the studied uncertainty could explain the differences between experimental measured strains and FEM strains. However, our numerical method does not include all the measurement uncertainty sources: uncertainties due to the transverse sensitivity of the gauge, the temperature compensation or the signal processing are not taken in account. Moreover, actual geometrical and load differences between the finite element model and the real runner are not considered either. We believe, however, that the two main factors influencing the measurement uncertainty sources are the displacement fields and the gauge geometry. Acknowledgments This study was carried out with the financial support of the Canadian research internship program, Mitacs-Accelerate. The authors acknowledge Andritz Hydro Ltd., the Institut de Recherche d Hydro- Québec (IREQ) and the École de technologie supérieure (ÉTS) for their support, materials and advice. Nomenclature K Gauge factor ΔL Length variation [mm] L 0 Initial gauge grid line length [mm] ΔR Gauge resistance variation [Ω] L Final gauge grid line length [mm] Measured Strain measured by the gauge [με] n Number of grid lines of the gauge gl j Estimated strain for the grid line j [με] R Gauge resistance [Ω] Estimated strain for the Virtual VWG Welded Gauge [με] U Displacement vector of point i [mm] Microstrain [mm/mm x 10 6 ] i References [1] James W F R and Dally W 1991 Experimental Stress Analysis 3rd ed (New-York: McGraw-Hill College Division) [2] Le Goër J L and Avril J 1992 Extensométrie Techniques de l ingénieur R 1850 17 [3] Pople J 1984 Experimental Techniques 8 9 34 38 [4] Vishay Micro-Measurements 2010 Special use sensors weldable strain gages Standard Weldable Patterns Document Number 11519 [5] Avril J 1984 Encyclopédie d analyse des contraintes (Malakoff: Micromesures) [6] Little E G, Ticher D, Colgan D and O Donnell P 2006 Strain 42 207 16 [7] Kobayoshi M and Queenie S H C 2005 Measurement 38 67 76 [8] Perry C 1969 Instruments and control systems 42 10 137 39 [9] Gafitanu M, Barsanescu P D and Poterasu V F 1989 Int. J. Pres. Ves & Piping 41 127 39 9

[10] Younis N T and Kang B 2011 Journal of Mechanical Science and Technology 25 1 163 169 10