FMP 038 uk 6-07-006 9:34 Pagina (,) New Headquarters : MP FILTRI S.p.A. Italy Via Maggio, n. 3 0060 Pessano con Bornago (Milano) Italy Tel. +39.0/95703. Fax +39.0/9574497-9574088 email: sales@mpfiltri.com http://www.mpfiltri.com USA MP FILTRI USA Inc. 055 Quaker Pointe Drive Quakertown, PA 895 Phone: +.5-59-300 Fax: +.5-59-90 email: sales@mpfiltriusa.com http://www.mpfiltriusa.com GREAT BRITAIN MP FILTRI U.K. Ltd. Bourton Industrial Park Bourton on the Water Gloucestershire GL54 HQ UK Phone: +44.045-85 Fax: +44.045-88 email: sales@mpfiltri.co.uk http://www.mpfiltri.co.uk CANADA MP FILTRI CANADA Inc. 380 Four Valley Drive Concorde Ontario Canada L4K 5Z Phone: +.905-303-369 Fax: +.905-303-756 email: mail@mpfiltricanada.com http://www.mpfiltricanada.com GERMANY MP FILTRI D GmbH Am Wasserturm 5 D-6665 Heusweiler/Holz Phone: +49.06806-850.0 Fax: +49.06806-850.8 email: service@mpfiltri.de http://www.mpfiltri.de RUSSIAN FEDERATION MP FILTRI RUSSIA Shenkursky proed, 3 Building B, office 308 7349 Moscow Phone/Fax: +7 (495) 60-34-83 GSM: +7 (495) 50-54- http://www.mpfiltri.ru FRANCE MP FILTRI FRANCE B.P. 65 7450 Evian Cedex Tel: +33.04-50-7-64-80 Telefax: +33.04-50-7-73-3 email: mpfiltrifrance@wanadoo.fr CMP 006 UK 00 A CHINA MP FILTRI P.O. Box 48-008 Shanghai Phone: +86.-570700 Fax: +86.-57700 sales@mpfiltrichina.com
FMP 038 uk 6-07-006 9:34 Pagina (3,) Pressure filter SERIES Maximum working pressure 40 bar F l o w r a t e s to 7 0 0 l / m i n s. p. a R
FMP 038 uk 6-07-006 9:34 Pagina 3 (,) Product Programme Contamination monitoring products Particle counters calibrated to ISO 7 On-line and In-line counting Bottle sampler options Remote operating capability Windows based software package RS 3 - RS 485 digital bus Suction Filters Flow rate to 60 lpm Tank immersed In-line extern a l In tank with shut off valve Return Filters Flow rates to 500 l/min Pre s s u re to 0 bar In-line extern a l Tank top In single and duplex designs Pressure Filters Flow rates to 700 l/min Pre s s u re from 0 bar to 40 bar In-line Manifold In single and duplex designs Spin-On filters Flow rates to 300 l/min Pre s s u re to 35 bar In-line Tank top
FMP 038 uk 6-07-006 9:34 Pagina 3 (3,) Product Programme Stainless Steel Pressure Filters Flow rates to 00 l/min Pre s s u re from 350 bar to 700 bar In-line Manifold In single and duplex designs In-line Filters Flow rates to 600 l/min Pre s s u res to 50 bar In-line Parallel manifiold version In single and duplex designs Filtration units Flow rates from 5 l/min to 00 l/min In static and mobile designs Accessories Oil filter and air breather plugs Optical and electrical level gauges Pre s s u re gauge valve selectors Pipe fixing brackets Pre s s u re gauges Mechanical Products Aluminium bell housings for motors from 0. Kw to 400 Kw Couplings in aluminium - cast iron - steel Damping rings Support feet Aluminium tanks Inspection doors CMP 006 UK 00 A 3
FMP 038 uk 6-07-006 9:34 Pagina 5 (,) FMP038 4
FMP 038 uk 6-07-006 9:34 Pagina 5 (3,) SERIES FMP038 Working pressure 0 bar Style S Style B B B D.I. D.I. A A 5
FMP 038 uk 6-07-006 9:34 Pagina 7 (,) Technical data Filter body ( M a t e r i a l s ) Head: Anodised Aluminium Housing: Anodised Aluminium Bypass valve: Brass P r e s s u r e Working pre s s u re: 0 bar ( MPa) Test pre s s u re: 60 bar (6 MPa) Burst pre s s u re: 330 bar (33 MPa) Pulsed pre s s u re fatigue test:,000,000 of cycles with variable pre s s u re from 0 to 0 bar ( MPa) Te m p e r a t u r e From - 5 C to + 0 C Bypass valve Opening pre s s u re 6 bar ±0% Other opening pre s s u res on re q u e s t. Elements type Δp Micro f i b re filter elements series N: 0 bar Stainless steel mesh elements series N: 0 bar Oil flow from exterior to interior. Filter Element Area Filter element in stainless steel mesh Length Type HP037, 5 0, 0 0 0, 5 0 5 350 570 700 Pressure drops Δp Housing Values expressed in cm The curves are plotted using mineral oil with density of 0.86 kg/dm 3 to ISO 3968. Δp varies proportional with density. Filter Housing S e a l s Standard Nitrile (NBR) Optional FPM series A series V 0, 0 0 0 8 36 54 7 90 Flow rate l/min Weights without filter elements ( k g. ) L e n g t h FMP038-0.8 FMP038 -.3 FMP038-5. Filter internal volumes ( d m 3 ) L e n g t h FMP038-0.8 FMP038-0.43 FMP038-5 0.35 C o n n e c t i o n s In-line Inlet/Outlet C o m p a t i b i l i t y Bodies compatible with: Mineral oils to ISO 943 - aqueous emulsions Synthetic fluids, water glycol. Filter elements compatible with: Mineral oils to ISO 943 - aqueous emulsions Synthetic fluids, water glycol. Nitrile (NBR) seals series A, compatible with: Mineral oils to ISO 943 - aqueous emulsions Synthetic fluids, water glycol. V series FPM seals, compatible with: Synthetic fluids type HS-HFDR-HFDS-HFDU 5 0 5 0 Bypass valve pre s s u re dro p s 0 4 36 48 60 Flow rate l/min 6
FMP 038 uk 6-07-006 9:34 Pagina 7 (3,) FMP 038 7 6 Dimensions Recommended maximum flow rate - Pre s s u re drop of complete filter equal to Δp.5 bar. - Oil kinematic viscosity 30 mm /s (cst). - Density 0.86 kg/dm 3. - Connections of filter under test G /. Filter Flow rate Filter e l e m e n t l / m i n L e n g t h t y p e Series N A 0 3 0 A 0 6 5 A 0 45 A 6 46 A 5 5 4 M 5 7 A 0 3 3 A 0 6 3 5 A0 50 A 6 58 5 A 5 6 6 Ø 55 M 5 86 A 03 40 A 0 6 4 3 Ch. A 0 58 A 6 6 A 5 7 M 5 9 0 A Threaded Connections Indicator and bypass valve positions can be interc h a n g e d. G / / NPT SAE 8-3/4-6 UNF Side B Bypass valve standard p o s i t i o n Clogging indicator Side C 6 4 Ch. 30 Ø 6,5 Filter Length 5 H mm 50 93 37 P l u g T - Ch. 30 Indicator standard position Side C Bypass valve alternative posit i o n Clogging indicator Side B 7
FMP 038 uk 6-07-006 9:34 Pagina 9 (,) Spare parts FMP038 4 6 5d 5e 5a 5e 5d 3 5b 5c Pos. Description Qty. Series FMP 038 FILTER 038-5 - Complete filter Filter Element See order table See order table 3 Bypass Assembly 0003 (NBR) 000385 (FPM) 4 No Bypass Assembly 00034 (NBR) 000386 (FPM) 5 Seals kit NBR FPM 005030 00503 5a Filter element O-Ring OR 4087 Ø.8 x 3.53 5b O-Ring for housing OR 300 Ø 50.47 x.6 5c Anti-extrusion ring Parbak 36 Ø 5.6 x.8 5d Bonded seal G / - FPM 5e O-Ring OR 050 Ø.4 x.78 - FPM 6 Indicator connection plug T - Indicator See order table 8
FMP 038 uk 6-07-006 9:34 Pagina 9 (3,) Filter assembly FMP 038 HP 037 3 4 5 6 Example: FMP038 B A G A0 N P0 Filter element 5 3 6 Example: HP037 A0 A N P0 Ordering information FMP038 7b 7 a - Filter length 5 - Filter element A03 3 µ Inorganic micro f i b re 5 A06 6 µ Inorganic micro f i b re A0 0 µ Inorganic micro f i b re ßx (c) 0 0 0 see page 9 - Bypass valve A6 A5 6 µ Inorganic micro f i b re 5 µ Inorganic micro f i b re B With bypass side B M5 Stainless steel mesh 5 m (in N style only) C D With side C bypass Without bypass with plug T side B 6 - Filter elements differential pressure E Without bypass with plug T side C N 0 bar F 3 - Seals A V Without connection to bypass valve NBR FPM 7 - Options a) Filter P0 T h readed connection for indicator (without plug T) P0 T h readed connection for indicator (with plug T) P03 Filters without connection for indicator 4 - Connections G G / Pxx Customer request b) Filter element G / NPT P0 MP Filtri standard G3 SAE 8 (3/4-6 UNF) Pxx Customer request DIFFERENTIAL INDICATORS (see page 5) MP Filtri - The filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. All rights reserved The data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or commercial requirements. The colours of the products shown on the cover are purely guideline. Copyright. All rights reserved. 9