X- ray Photoelectron Spectroscopy and its application in phase- switching device study

Similar documents
Introduction to X-ray Photoelectron Spectroscopy (XPS) XPS which makes use of the photoelectric effect, was developed in the mid-1960

Electron Spectroscopy

Lecture 5. X-ray Photoemission Spectroscopy (XPS)

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

Advanced Lab Course. X-Ray Photoelectron Spectroscopy 1 INTRODUCTION 1 2 BASICS 1 3 EXPERIMENT Qualitative analysis Chemical Shifts 7

QUESTIONS AND ANSWERS

Energy Spectroscopy. Ex.: Fe/MgO

Photoemission Spectroscopy

Photoelectron spectroscopy Instrumentation. Nanomaterials characterization 2

Energy Spectroscopy. Excitation by means of a probe

5) Surface photoelectron spectroscopy. For MChem, Spring, Dr. Qiao Chen (room 3R506) University of Sussex.

Birck Nanotechnology Center XPS: X-ray Photoelectron Spectroscopy ESCA: Electron Spectrometer for Chemical Analysis

X-Ray Photoelectron Spectroscopy (XPS)

Auger Electron Spectroscopy (AES)

Lecture 5-8 Instrumentation

Electron Spettroscopies

Special Properties of Au Nanoparticles

Lecture 23 X-Ray & UV Techniques

Methods of surface analysis

X-Ray Photoelectron Spectroscopy (XPS)

Photoelectron Spectroscopy. Xiaozhe Zhang 10/03/2014

X-ray Photoelectron Spectroscopy (XPS)

The Use of Synchrotron Radiation in Modern Research

Studying Metal to Insulator Transitions in Solids using Synchrotron Radiation-based Spectroscopies.

ABC s of Electrochemistry: X-Ray Photoelectron Spectroscopy (XPS) Madhivanan Muthuvel

Name: (a) What core levels are responsible for the three photoelectron peaks in Fig. 1?

XPS & Scanning Auger Principles & Examples

PHOTOELECTRON SPECTROSCOPY (PES)

Fig 1: Auger Electron Generation (a) Step 1 and (b) Step 2

XPS Depth Profiling of Epitaxial Graphene Intercalated with FeCl 3

Reduced preferential sputtering of TiO 2 (and Ta 2 O 5 ) thin films through argon cluster ion bombardment.

Characterization of Secondary Emission Materials for Micro-Channel Plates. S. Jokela, I. Veryovkin, A. Zinovev

Ma5: Auger- and Electron Energy Loss Spectroscopy

X-Ray Photoelectron Spectroscopy (XPS) Auger Electron Spectroscopy (AES)

X-ray Photoelectron Spectroscopy/ Electron spectroscopy for chemical analysis (ESCA), By Francis Chindeka

Probing Matter: Diffraction, Spectroscopy and Photoemission

IV. Surface analysis for chemical state, chemical composition

Supplementary Information

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

5.8 Auger Electron Spectroscopy (AES)

Auger Electron Spectroscopy (AES) Prof. Paul K. Chu

Photoelectron Spectroscopy Evidence for Electronic Structure Guided-Inquiry Learning Activity for AP* Chemistry

The Benefit of Wide Energy Range Spectrum Acquisition During Sputter Depth Profile Measurements

Properties of Light and Atomic Structure. Chapter 7. So Where are the Electrons? Electronic Structure of Atoms. The Wave Nature of Light!

Group Members: Your Name In Class Exercise #6. Photon A. Energy B

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Determining Chemical Composition. Of Sputtered Uranium Oxide Thin Films. through X-Ray Photoelectron Spectroscopy

Auger Electron Spectroscopy *

Semiconductor Physics and Devices

Local Anodic Oxidation of GaAs: A Nanometer-Scale Spectroscopic Study with PEEM

X-Ray Photoelectron Spectroscopy (XPS)-2

Metal Deposition. Filament Evaporation E-beam Evaporation Sputter Deposition

Table 1: Residence time (τ) in seconds for adsorbed molecules

X-Ray Photoelectron Spectroscopy (XPS)-2

Surface Analysis - The Principal Techniques

Photon Interaction. Spectroscopy

1 Electrons are emitted from a metal surface when it is illuminated with suitable electromagnetic radiation. ...[1]

X-Ray Photoelectron Spectroscopy: Theory and Practice

Fig Photoemission process.

Chapter Six: X-Rays. 6.1 Discovery of X-rays

Dr. Tim Nunney Thermo Fisher Scientific, East Grinstead, UK Dr. Nick Bulloss Thermo Fisher Scientific, Madison, WI, USA Dr. Harry Meyer III Oak Ridge

Photoelectric Effect Experiment

1 Introduction COPYRIGHTED MATERIAL. 1.1 HowdoweDefinetheSurface?

Electronic Supplementary Information. Molecular Antenna Tailored Organic Thin-film Transistor for. Sensing Application

3. Experimental Methods and Instrumentation.

1. What is the minimum energy required to excite a mercury atom initially in the ground state? ev ev ev

4. Inelastic Scattering

MODERN TECHNIQUES OF SURFACE SCIENCE

Inelastic soft x-ray scattering, fluorescence and elastic radiation

Optimizing Graphene Morphology on SiC(0001)

Photoelectron Spectroscopy using High Order Harmonic Generation

X-ray Photoemission Spectroscopy (XPS - Ma4)

ATOMIC STRUCTURE, ELECTRONS, AND PERIODICITY

Chemistry Instrumental Analysis Lecture 2. Chem 4631

Modern Physics Lesson 1: Intro to Quantum Mechanics and Photoelectric Effect Lesson 2: Energy Levels Lesson 3: E = mc^2 Lesson 4: Standard Model of

The design of an integrated XPS/Raman spectroscopy instrument for co-incident analysis

structure and paramagnetic character R. Kakavandi, S-A. Savu, A. Caneschi, T. Chassé, M. B. Casu Electronic Supporting Information

An Introduction to Auger Electron Spectroscopy

AES - Auger Electron Spectrosopy

EE 527 MICROFABRICATION. Lecture 5 Tai-Chang Chen University of Washington

Chapter 37 Early Quantum Theory and Models of the Atom. Copyright 2009 Pearson Education, Inc.

MSE 321 Structural Characterization

Nova 600 NanoLab Dual beam Focused Ion Beam IITKanpur

The photoelectric effect

Particle Detectors and Quantum Physics (2) Stefan Westerhoff Columbia University NYSPT Summer Institute 2002

Photoelectric Effect

FEASIBILITY OF IN SITU TXRF

CHARACTERIZATION of NANOMATERIALS KHP

Advantages of coincident XPS-Raman in the analysis of mineral oxides species

6. Analytical Electron Microscopy

For the next several lectures, we will be looking at specific photon interactions with matter. In today s lecture, we begin with the photoelectric

Half-Integer Quantum Conductance States

Chapter 9: Quantization of Light

Solid Surfaces, Interfaces and Thin Films

Surface and Interface Characterization of Polymer Films

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Auger Electron Spectroscopy Overview

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

The Franck-Hertz Experiment David Ward The College of Charleston Phys 370/Experimental Physics Spring 1997

Applications of XPS, AES, and TOF-SIMS

Transcription:

X- ray Photoelectron Spectroscopy and its application in phase- switching device study Xinyuan Wang A53073806 I. Background X- ray photoelectron spectroscopy is of great importance in modern chemical and material science, which is also known as electron spectroscopy for chemical analysis (ESCA) for learning the surface elemental composition and speciation of solid substrate within 10nm depth. The surface of solids plays a crucial when perceiving with the outer environment as it is often quite different from the underlying material, thus making the physical properties varies such as adhesion, biocompatibility, and interfacial electrical properties and so on. If the composition and speciation of solid surface can be figured out, we are able to understand the inner principles of how they interact with external forces and explore material mortification methods to satisfy further application. ESCA, first introduced by Kai Seigbahn, is the origin of XPS technology. By irradiating materials with x- ray beam, the electrons are kicked off and their kinetic energy and numbers are analyzed. Its abilities in identifying and quantifying the elemental composition of the outer 10 nm or less of any solid surface with all elements from Li U detectable and revealing the chemical environment where the respective element exists in are realized since then. In this paper, we mainly talk about the basic physics of XPS and how measurements are made with instruments. Then a simple example is given which shows the procedures of analyzing XPS data results focusing on Tantalum oxide. After that figures in the reference paper are further introduced revealing the significant role of XPS to understand semiconductor fundamentals. II. Basic Principles XPS is based on photoelectric effect which was first noted by Heinrich Hertz and explained by Albert Einstein. He showed that this induced electron emission from metallic objects if the energy transfer was greater than the biding energy between the electron and the respective metal atom, and creatively introduce the concept of the photon a massless particle with no charge which is the quantum of electromagnetic radiation in quantum field. Its energy and momentum can be expressed with

E = hv p = ħk where h is Plank s constant, v is its frequency and k is its wave vector. When a photon hits the material which cause electrons from atomic orbitals or bands moving out to the vacuum level, the photoemission process happens. This process require energy high enough to overcome the attraction from nuclei, in other words the initial energy of photon should be larger than the emitted electron s binding energy. Following the energy conservation rule, hv = E! + E!"# hv is the photon energy, E! is the electron binding energy with respect to vacuum level prior to ionization and E!"# is the kinetic energy of photoelectron. Generally E! is taken place by E! + φ relative to Fermi level. Here is a schematic figure showing how the photoemission process takes place, Figure 1. The photoelectron emission process Subsequently, as the emitted electron leaves a hole in lower energy level, electrons from upper levels will drop to its nearest lower level which also results in photon emission, called Auger process. With the above description, X- rays are found ideally suited to probe the core levels of a solid, which generally show no dispersion due to their highly localized atomic- like character. Two crucial parameters to describe the XPS ability are surface specificity and sensitivity. An electron has a limited flight mean path in solid before losing part of its energy. When X- rays penetrating the solid, almost all the photoelectrons will lose energy at the depth above 10nm, leading to that the signals only exist at the surface

region. Sensitivity is dependent on the photoelectron cross section and the spectral background. The photoelectron cross section describes the yield of electrons produced as a function of the impacting photon energy. This also gives the reason why Hydrogen and Helium are not detectable in solids because of their low photoelectron cross sections. III. XPS Instrumentation A XPS instrument primarily contains three parts, 1) An X- ray source 2) Extraction optics and energy filter (energy analyzer) 3) A detection system And within the instrument the environment should keep the photoemission process not affected by external electric or magnetic fields. Besides the emitted electrons should be able to traverse from the sample to detector and not modified during the analysis. Thus a vacuum condition is necessary in XPS to satisfy the above requirements. Figure 2. The schematic system of SPS instrument The above figure shows a schematic system of XPS. The source is the unit from which X- rays are produced/directed onto the sample. There are generally two options of sources in self- contained XPS instruments, the standard and monochromatic. Monochromatic source with Al- Kα1 emissions are increasingly popular due to the ability to produce a focused X- ray beam without the requirement of the source being in close proximity to the sample and the narrower energy spread of the resulting X- rays. X- rays of narrower energy spread than this can only be produced in synchrotrons. The energy resolution in XPS is primarily dependent on the source.

Energy filters used in XPS tend to consist of CHAs. These are heavily favored over CMAs due to their superior energy resolution and the fact that when operated under the CAE mode, these provide a constant energy resolution over the entire B.E.XPS range of interest. In addition, little variation in B.E.XPS values is noted once the sample analyzer distance is optimized. CHAs also allow for the incorporation of transfer lenses. SMAs, a variant of the CHA, are also used in imaging. Detectors are comprised of some form of EM. The type used depends on the information of interest. If counts over some large area are required, multiple channeltrons placed along the energy- dispersive axis of the energy filter are the best option. Additional information that is, imaging of the spatially dispersed and/or angularly dispersed data can be acquired using an MCP detector when combined with CHA or SMA. Imaging can be carried out in one of several modes, with the parallel mode providing the best spatial resolution. IV. XPS Data Analysis XPS requires little in the way of sample preparation. Indeed, all that is generally required is that (a) The sample be of a size amenable to that of the instrument (b) The surface of interest remains clean before and during analysis (c) The surface of the sample be ultrahigh vacuum (UHV) as well as X- ray compatible To better understanding the data analyzing process in XPS, I refer to the data measured during my undergraduate study on bilayer Tantalum oxide based resistive- switching memory device. The device consists of two layers of different compositional tantalum oxide. About 40nm- thick TaO! was deposited by RF reactive magnetron sputtering at pressure of 6.3 10!! Torr with 3.3% O! partial pressure in Ar and O! ambient. Next, 25nm- thick Ta! O!!! was deposited at the pressure of 2 10!! Torr with 6% O! partial pressure. First we get a wide- scan or survey spectrum of a somewhat dirty silicon wafer, showing all elements present. A survey spectrum is usually the starting point of most XPS analyses because it shows all elements present on the sample surface and allows one to set up subsequent high- resolution XPS spectra acquisition. The following figure shows a quantification table indicating all elements observed, their binding energies, and their atomic percentages, from which obvious peaks of O and Ta are observed.

Figure 3. The survey spectrum of bilayer tantalum oxide Notice here there exists a C- 1s peak which is used as ensuring accurate calibration of the gap φ between two energy references E!"##$% and E! in insulator. The C- 1s peak arising from adventitious carbon. Adventitious carbon arises from the adsorption of aliphatic hydrocarbons from the atmosphere, which includes that present under UHV. These are useful since they can provide an effective internal reference check but only if the C- 1s from these adsorbates on the respective surface is well- known to within 0.1 ev. XPS depth analysis was done to study the element composition and structure in the surface of tantalum oxide of which the thickness is within 10nm. The figure below shows the atomic percentage of O1- s and Ta4- f. The concentration of Ta rises after 600s etching, which indicates a transform from oxygen- rich layer to oxygen- deficient layer. Figure 4. The atomic concentration of Ta and O along depth High- resolution spectrums of two elements in the bilayer strucutre are separately displayed at different etching times. The choice of 200s and 1040s is dependent on the above concentration comparison between O and Ta, in order to show the difference of

two tantalum oxide layers. The raw data spectrum (black) is fitted with several components or chemical states. At 200s etching time, the more oxidized forms of Ta (Ta! O! ) appear at higher binding energies at about 28.9eV and 27.2eV, which are Ta4 f!/! and Ta4 f!/!. Besides the typical Ta 4f two peaks at the surface, the profile spectra can be decomposed into many other peaks indicating tantalum suboxides. When look at the O1- s spectra, it can actually be fitted with two Gaussian components centered between 531~532eV. Figure 5. O and Ta spectrum at etching time 200s In the 1040 etching time spectrums, the so- called metallic form of Ta exhibits a set of doublet peaks at around 22±0.2eV. Also new strong doublet attributed to Ta suboxide forms clearly, and the Ta 4f doublet changes its typical form to a shallow peak with significantly increased intensity. The variation of the intensity of the different peaks indicates that tantalum suboxides and metallic Ta dominate in the oxygen- deficient layer. Figure 6. O and Ta spectrum at etching time 1040s

V. Application in the paper The reference paper uses similar method to analysis its device structure and composition. Figure 7 shows the atomic percentage by fitting O- 1s, Al- 2p, and W- 4f peaks. The concentration of O rises after 2000s etching time and declines after 4000s, which indicates an existence of oxygen- rich layer. Figure 7. XPS depth profile of Al/W:AlOx/WOx/W/Al stack In order to distinguish this oxide layer, O 1s peaks were analyzed as shown in Figure 8. Four etching times 2200s, 4200s, 6200s, and 7800s with distinct compositions were chosen for analysis. The O- 1s spectra at the points 1 and 4 show a singlet peak at 532:1±:5eV and 530:8±:5eV which correlate to AlOx and WOx seperately. The O- 1s peaks at points 2 and 3 are the combination of these two peaks. The separating curves confirm the oxide layer transformed from AlOx to WOx. The spectra of Al- 2p and W- 4f shows peaks at different binding energies which are correlated to different chemical state. This work is of much importance to study the device structure and to further modify the parameters in fabricating process aiming to improve its properties. First of all, it helps us to understand the inner mechanism of how the device works. The metal oxide based resistive- switching memory is a good example to display the mentioned importance. As the electrical characteristics of layers with different composition varies and may even lead to some unexpected results. The XPS analysis offers confirmation or correction on previous guess as well as arouse new conceptions.

Figure 8. O 1s, Al 2p, and W 4f XPS spectra Figure 9. Summary of the concentration