Title. Author(s) Nakashima, Kenichiro; Kuroda, Naota. Issue Date Copyright 2009 Published by Elsev

Similar documents
Mizoroki-Heck coupling reaction. Ikeda, Rie; Nakashima, Kenichiro; K

Kenichiro; Kuroda, Naotaka

Harada, Shiro; Nakashima, Kenichiro

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM

hydrophilic interaction liquid chro Citation Journal of Separation Science, 38(5

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

A Fluorescence Turn-On Sensor for the Detection of Palladium Ions that Operates Through In-Situ Generation of Palladium Nanoparticles

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

Supporting Information. High-Throughput Screening Protocol for the Coupling Reactions of Aryl Halides Using a Colorimetric Chemosensor for Halide Ions

Appendix II- Bioanalytical Method Development and Validation

ADVANTAME. Not less than 97.0% and not more than 102.0% on the anhydrous basis. Sweetener, flavour enhancer

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

637. Thiamethoxam. HPLC method

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Volume 6, Issue 2, January February 2011; Article-015

Impact factor: 3.958/ICV: 4.10 ISSN:

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

High Performance Liquid Chromatography

High Performance Liquid Chromatography

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

Heterogeneously catalyzed selective aerobic oxidative cross-coupling of terminal alkynes and amides with simple copper(ii) hydroxide

First Prebiotic Generation of a Ribonucleotide from Adenine, D Ribose and Trimetaphosphate

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Rational design of light-directed dynamic spheres

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Voltage-Induced Sample Release from Anion Exchange Supports in Capillary Electrochromatography

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs

IMPROVED CHROMATOGRAPHIC METHOD FOR DETERMINATION OF SODIUM DICLOFENAC IN INJECTABLE SOLUTION AND PREDICTION OF CHEMICAL STABILITY

1Determination of optical purity of N-acetyl-1-naphthylethylamine by chiral chromatography and NMR spectroscopy

Supporting Information

with diode array detection

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

Egualen Sodium Granules

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

A rapid and highly selective colorimetric method for direct detection of tryptophan in proteins via DMSO acceleration

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

Determination of Caffeine by HPLC

462 1 & (2&3 ( 4 5 6" 6 7 ' ("0 / L1 1 % FG &

Determination of Formaldehyde in Aqueous Samples with a Miniaturized Extraction Capillary Coupled to High-Performance Liquid Chromatography

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

8. Methods in Developing Mobile Phase Condition for C18 Column

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

ADVANTAME (TENTATIVE)

H 3 CO H 3 CO S CH 3

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Supporting Information

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

penta-hilic UHPLC COLUMNS

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Asian Journal of Research in Chemistry and Pharmaceutical Sciences Journal home page:

Supporting Information. Visualization of Phagosomal Hydrogen Peroxide Production by A Novel Fluorescent Probe That Is Localized via SNAP-tag Labeling

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

This method describes the identification of the following prohibited colorants in cosmetic products:

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Laboratory of Analytical Chemistry, Faculty of Textile Science, Matsugasaki, Sakyo, Kyoto 606, Japan. Kyoto Institute of Technology,

International Journal of Current Trends in Pharmaceutical Research. International Journal of Current Trends in Pharmaceutical Research

Effect of Column Length on Forecasted Retention Times and Carbon Numbers in an Isothermal and Temperature-programmed Gas Chromatography

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

METHANOLYSIS OF ACETAL

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 9(1), 35-42

CHAPTER 19 PARACETAMOL + IBUPROFEN

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

It s hot! ZIC -chilic

Evolution of Solid Phase Homochirality for a. Proteinogenic Amino Acid

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

Sulfotepp impurities in Chlorpyrifos EC formulations

The photoluminescent graphene oxide serves as an acceptor rather. than a donor in the fluorescence resonance energy transfer pair of

A Combination of Visible-light Photoredox and Metal Catalysis for the Mannich-type Reaction of N-Aryl Glycine Esters

Journal of Chemical and Pharmaceutical Research, 2017, 9(1): Research Article

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

for Acclaim Mixed-Mode HILIC-1 Column

Determination of Gallic acid from their Methanolic Extract of Punica granatum By HPLC Method

Department of Quality Assurance, Luqman College of Pharmacy, GULBARGA (K.S.) INDIA ABSTRACT

Determination of Retention Factors of Aromatic Compounds by Gradient-Elution Reverse-Phase High Performance Liquid Chromatography

Dissolution Test 5 was validated using a Zodiac C18 brand of L1 column. The typical retention time for atorvastatin is about min.

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

Introduction to Pharmaceutical Chemical Analysis

Tomofumi Santa, Taizo Okamoto, Seiichi Uchiyama, Kazuto Mitsuhashi and Kazuhiro Imai*

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

Supporting Information

Supporting Information for

Transcription:

NAOSITE: Nagasaki University's Ac Title Author(s) Fluorogenic derivatization of aryl biphenyl by Suzuki coupling reactio Kishikawa, Naoya; Kubo, Kimiko; Ham Mokhtar Mohamed; Habib, Ahmed; Elfa Nakashima, Kenichiro; Kuroda, Naota Citation Journal of chromatography. A, 1216( Issue Date 2009-10 URL http://hdl.handle.net/10069/22230 Right Copyright 2009 Published by Elsev This document is downloaded http://naosite.lb.nagasaki-u.ac.jp

Fluorogenic derivatization of aryl halides based on the formation of biphenyl by Suzuki coupling reaction with phenylboronic acid Naoya Kishikawa a, Kimiko Kubo a, Sherin Farouk Hammad b, Mokhtar Mohamed Mabrouk b, Ahmed Habib b, Hamed Elfatatry b, Kaname Ohyama a, Kenichiro Nakashima a and Naotaka Kuroda a * a Graduate School of Biomedical Sciences, Course of Pharmaceutical Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan b Department of pharmaceutical analytical chemistry, Faculty of Pharmacy, Tanta University, El-Giesh St., Tanta, Gharbia, Egypt *Corresponding author: Naotaka Kuroda Graduate School of Biomedical Sciences, Course of Pharmaceutical Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan Phone: +81-95-819-2894 Fax: +81-95-819-2444 E-mail: n-kuro@nagasaki-u.ac.jp 1

Abstract The fluorogenic derivatization method for aryl halide was developed for the first time. This method was based on the formation of fluorescent biphenyl structure by Suzuki coupling reaction between aryl halides and non-fluorescent phenylboronic acid (PBA). We measured the fluorescence spectra of the products obtained by the reaction of p-substituted aryl bromides (i.e., 4-bromobenzonitrile, 4-bromoanisole, 4-bromobrnzoic acid ethyl ester and 4-bromotoulene) with PBA in the presence of palladium (II) acetate as a catalyst. The significant fluorescence at excitation maximum wavelength of 275-290 nm and emission maximum wavelength of 315-350 nm was detected in all the tested aryl bromides. This result demonstrated that non-fluorescent aryl bromides could be converted to the fluorescent biphenyl derivatives by the coupling reaction with nonfluorescent PBA. We tried to determine these aryl bromides by HPLC-fluorescence detection with pre-column derivatization. The aryl bromide derivatives were detected on the chromatogram within 30 min without any interfering peak derived from the reagent blank. The detection limits (S/N=3) for aryl bromides were 13-157 fmol/injection. Keywords: Fluorescence derivatization, Phenylboronic acid, Aryl halide, Fluorogenic, Suzuki coupling reaction 2

1. Introduction Fluorescence detection is applied to analyze trace amount of compounds in combination with high-performance liquid chromatography (HPLC) or capillary electrophoresis (CE) because it has high sensitivity and selectivity. However, most of compounds are non-fluorescent or weakly fluorescent. Therefore, fluorescence derivatization reagents have been developed for conversion of non- or weakly fluorescent compounds to highly fluorescence compounds. Up till now, various fluorescence derivatization reagents for a wide variety of functional groups, such as amine, phenol, thiol, aldehyde, ketone and carbonyl groups have been developed [1-4]. However, it is difficult to derivatize the compounds that do not have derivatizable functional group with a typical fluorescence derivatization reagent. We recently developed the fluorescent aryl boronic acid, 4-(4,5-diphenyl-1H-imidazol-2-yl)phenylboronic acid (DPA, a lophine derivative) as a fluorescence derivatization reagent for aryl halides [5]. The derivatization reaction with DPA is based on Suzuki coupling reaction [6], which is a palladium-catalyzed cross-coupling reaction of aryl halides with aryl boronic acids. DPA can convert compounds having an aryl halide in their structures into fluorescent compounds, even in the absence of the derivatizable functional groups for a conventional derivatization reagent. Furthermore, we found that Suzuki coupling proceeded well without the interference with biological compound and this was the practical reaction for biomedical analysis. By using DPA, we have developed the determination method for aryl halide drugs including clofibrate [5], haloperidol [7] and hydroxyzine [8] in 3

biological fluids. However, DPA has strong fluorescence itself and sometimes interfere the detection of target derivatives On the other hand, fluorescence derivatization reagents are categorized in two groups i.e., fluorescence labeling reagent and fluorogenic derivatization reagent [9]. The fluorescent labeling reagent is composed of strong fluorophore and reactive group for reacting with the functional group of the target compounds. In contrast to fluorescent labeling reagent like DPA, fluorogenic derivatization reagent is non-fluorescence itself; however, it reacts with target compound and form fluorescent structure. The fluorogenic derivatization reagent can greatly reduce the interference from fluorescence of the reagent compared with fluorescence labeling reagent. Therefore, we attempted to develop the fluorogenic derivatization reagent for aryl halides based on Suzuki coupling reaction. We selected phenylboronic acid (PBA) as a fluorogenic derivatization reagent for aryl halides. PBA is non-fluorescent mono substituted benzene and the boronic acid works for derivatization reaction. It was expected that the aryl halides reacted with PBA to form fluorescent biphenyl derivatives (Fig. 1). In this study, we employed p-substituted aryl bromide as a model compound of aryl halide. The fluorescence spectra of the products obtained by the reaction of p-substituted aryl bromide with PBA were measured. Subsequently, we established pre-column derivatization HPLC method for aryl bromides to evaluate the analytical performance of the proposed derivatization reaction. 4

2. Experimental 2.1 Material and reagents PBA, 4-bromobenzonitrile (BrPhCN), 4-bromoanisole (BrPhOCH 3 ), 4- bromobenzoic acid ethyl ester (BrPhCOOC 2 H 5 ) and 4-bromotoulene (BrPhCH 3 ) were purchased from Tokyo Chemical Industries (Tokyo, Japan). 4-Phenylbenzonitrile and 4- methoxybiphenyl were from Sigma (St. Louis, MO, USA). Palladium (II) acetate (Pd(OAc) 2 ), potassium fluoride (KF), N,N-dimethylformamide (DMF) were from Nacalai Tesque (Osaka, Japan). Acetonitrile and dioxane were from Kanto Chemical (Tokyo, Japan) and Wako (Tokyo, Japan), respectively. Water was distilled and passed through a Pure Line WL21P system (Yamato, Tokyo, Japan). All other chemicals were the highest purity and quality available. 2.2 Fluorescence spectra measurement of the products by the reaction of aryl bromides with PBA To the dioxane solution including aryl bromides (50 µl), 7.5 mm PBA in dioxane (50 µl), 3.0 m M Pd(OAc) 2 in dioxane and aqueous solution of 30 mm KF (50 µl) were successively added and mixed well. After purging with N 2 (5.0 ml/s) for 5 s, the reaction mixture was heated at 100 ºC for 30 min. After cooling, the reaction mixture was diluted 10 times with a mixture of acetonitrile and 5 mm phosphate buffer (ph 5.5) (50:50, v/v) for the fluorescence measurement. Fluorescence spectra and intensities were measured with a 650-10S fluorescence spectrophotometer (Hitachi, Tokyo, Japan). 5

2.3 Pre-column derivatization HPLC method for aryl bromides The HPLC system consisted of an pump LC-6A (Shimadzu, Kyoto, Japan), a Shimadzu RF-550 fluorescence detector, a 7125 injector with a 20-µL loop (Rheodyne, Cotati, CA, USA), and a FBR-1 recorder (Tosoh, Tokyo, Japan). Chromatographic separation was performed on a Cosmosil 5C18MS (250 mm x 4.6 mm, i.d., Nacalai tesque) by an isocratic elution with a mixture of acetonitrile and 5 mm phosphate buffer (ph 5.5) (60:40, v/v) at a flow rate of 1.0 ml/min. The fluorescence wavelength of the detector was changed according to the time program to detect each derivative at a maximum wavelength. For the derivatization for HPLC analysis, DMF was employed to prepare each solution of aryl bromides, PBA and Pd(OAc) 2 because the peak heights of derivatives obtained using DMF were slightly higher than those obtained using dioxane. A 20-µL portion of the resultant reaction mixture after passing through a membrane filter (0.45 µm, HLC-DISK 3, Kanto chemical) was injected into the HPLC system. Calibration curves were prepared by analyzing five or six different concentrations of standard aryl bromide solutions in triplicate. The detection limits were defined as the concentration corresponding to a signal three times the noise level. 3. Results and Discussion Fig. 2 shows the fluorescence spectra of the reaction mixture of BrPhCOOC 2 H 5 with PBA. The fluorescence was observed at excitation and emission maximum of 290 nm and 350 nm, respectively. Hence, this result presented that BrPhCOOC 2 H 5 was 6

converted to fluorescent compound by the reaction with PBA. On the other hand, the significant fluorescence was not observed from the reagent blank. Table 1 shows the fluorescence characteristics of the products obtained by the reaction of four aryl bromide with PBA. All of the products emit the fluorescence at excitation of 275-290 nm and emission of 315-350 nm. Because these excitation and emission wavelengths were very similar to those of biphenyl, it was strongly suggested that aryl bromides were converted to biphenyls by Suzuki coupling reaction with PBA. BrPhCN and BrPhCOOC 2 H 5, which have electron-withdrawing group at p- position of bromo group, emit stronger fluorescence at relatively longer wavelength regions than BrPhOCH 3 and BrPhCH 3, having electron-donating group. To clarify whether the different fluorescence characteristics was due to the difference of reaction yield or the fluorescence intensity of the products, we measured the fluorescence intensities of standard solution of 4-phenylbenzonitrle and 4-methoxybiphenyl, that are possible reaction products of BrPhCN and BrPhOCH 3 with PBA, respectively. As a result, the fluorescence intensity of 4-phenylbenzonitrile was 3 times higher than that of 4-methoxybiphenyl. Therefore, the fluorescence intensity of the products can be attributed to the fluorescence characteristics of each product. Fig. 3(A) and (B) show the chromatograms obtained by the injection of the reagent blank (PBA) and reaction mixture of aryl bromides with PBA into HPLC system, respectively. Under the HPLC conditions described in experimental section, all the peaks derived from aryl bromides were detected within 30 min. On the other hand, no reagent blank peaks significantly interfering the detection of the aryl bromides were observed on the chromatogram because the PBA is non-fluorescent. In order to confirm that the peaks 7

at 12 and 17 min in Fig. 3(B) were derived from BrPhCN and BrPhOCH 3, authentic 4- phenylbenzonitrile and 4-methoxybiphenyl that corresponds to each derivative were injected into the HPLC system. As shown in Fig. 3(C), the retention times of 4- phenylbenzonitrile and 4-methoxybiphenyl were identical with those of the derivative of BrPhCN and BrPhOCH 3, respectively, which revealed that aryl bromide was converted to biphenyl by the reaction with PBA. The reaction yields for BrPhCN and BrPhOCH 5, were 100 and 97%, respectively, calculated by comparing the peak heights of the reaction products and authentic 4-phenylbenzonitrile and 4-methoxybiphenyl. The derivatization reaction for aryl bromides proceeded with excellent yield. On the other hand, the reaction yields for 4-iodobenzonitrile and 4-chlorobenzonitrile, both of which produce 4- phenylbenzonitrile by reaction with PBA, were 100 and 50%, respectively. The tendency of the reactivity was agreed with the results of our previous report by using DPA [5]. The proposed derivatization method can also be applied to aryl iodide and even aryl chloride. Calibration curves were prepared with a standard mixture of aryl bromides and good linearities (r 2 > 0.999) were observed between the fluorescence intensity as peak height and concentration of aryl bromides up to 50 µm (Table 2). The detection limits of standard aryl bromides ranged from 13 to 157 fmol/injection at a signal-to-noise ratio (S/N) of 3. The sensitivities of BrPhCH 3 and BrPhOCH 3 of the proposed method were 3 and 10 times higher than those of the fluorescence labeling method with DPA [5]. The repeatability of the proposed method was examined at 1 µm and 5 µm of aryl bromides. The relative standard deviations for within-day (n = 5) and between-day (n = 5) runs were less than 7.8 and 8.6%, respectively, for all the analytes. 8

4. Conclusion In this study, we reported a novel fluorogenic derivatization reaction for aryl halides based on the formation of biphenyl derivative by Suzuki coupling reaction of aryl halides with PBA. Because PBA is non-fluorescent compounds, the interference derived from the reagent can be negligible. The pre-column derivatization HPLC based on the proposed reaction allowed the sensitive detection of aryl bromides with the detection limits of 13-157 fmol/injection. We previously demonstrated that Suzuki coupling reaction was well applied to biomedical analysis [5, 7-8], and therefore the fluorogenic derivatization reaction will become a promising tool for the development of sensitive determination method for aryl halides. 9

References [1] M. Yamaguchi and J. Ishida In: T. Toyo oka, Editor, Modern Derivatization Methods for Separation Sciences: Reagent for FL Detection, Wiley, Chichester (1999), p. 99. [2] K. Nakashima, Biomed. Chromatogr. 17 (2003), 83. [3]. T. Fukushima, N. Usui, T. Santa, K. Imai, J. Pharm. Biomed. Anal. 30 (2003) 1665. [4] S. Uchiyama, T. Santa, N. Okiyama, T. Fukushima, K. Imai, Biomed. Chromatogr. 15 (2001) 295. [5] N. Kuroda, S. Sugihara, Y. Sugihara, M. Wada, N. Kishikawa, Y. Ohba, K. Nakashima, J. Chromatogr. A 1066 (2005) 119. [6]. A. Suzuki, J. Organomet. Chem. 576 (1999) 147. [7] N. Kishikawa, C. Hamachi, Y. Imamura, Y. Ohba, K. Nakashima, Y. Tagawa, N. Kuroda, Anal. Bioanal. Chem. 386 (2006) 719. [8] S.F. Hammad, M.M. Mabrouk, A. Habib, H. Elfatatry, N. Kishikawa, K. Nakashima, N. Kuroda, Biomed. Chromatogr. 21 (2007) 1030. [9] Y. Ohkura, M. Kai, H. Nohta, J. Chromatogr. B 659 (1994) 85. 10

Figure captions Fig. 1. Scheme of the proposed fluorogenic derivatization reaction for aryl bromide. Fig. 2. Fluorescence spectra obtained from the reaction mixture of BrPhCOOC 2 H 5 with PBA and the reagent blank. Excitation spectra with the emission wavelength at 350 nm of the product (A, solid line) and the reagent blank (B, dashed line). Emission spectra with the excitation wavelength at 290 nm of the product (C, solid line) and the reagent blank (D, dashed line). Fig. 3 Chromatograms of (A) reagent blank, (B) reaction mixture and (C) authentic biphenyls. Peaks: 1, BrPhCN derivative; 2, BrPhOCH 3 derivative; 3, BrPhCOOC 2 H 5 derivative; 4, BrPhCH 3 derivative; 1 4-phenylbenzonitrile; 2, 4-methoxybiphenyl. Sample concentration: 25 µm for all compounds. 11

HO R Br B R = CN, OCH 3, COOC 2 H 5, CH 3 Aryl bromide (non-fluorescence) + HO Phenylboronic acid (non-fluorescence) Pd(OAc) 2 Base R Biphenyl derivative (fluorescence) Fig. 1 Scheme of the proposed fluorogenic derivatization reaction for aryl bromide. 12

(A) (C) Relative fluorescence intensity (B) (D) 220 260 300 340 380 420 Wavelength, nm Fig. 2. Fluorescence spectra obtained from the reaction product of BrPhCOOC 2 H 5 with PBA and the reagent blank. Excitation spectra with the emission wavelength at 350 nm of the product (A, solid line) and the reagent blank (B, dashed line). Emission spectra with the excitation wavelength at 290 nm of the product (C, solid line) and the reagent blank (D, dashed line). 13

(A) (B) (C) 1 1 Relative fluorescence intensity Relative fluorescence intensity 2 3 Relative fluorescence intensity 2 4 0 15 30 Retention time, min 0 15 30 0 15 Retention time, min Retention time, min Fig. 3 Chromatograms of (A) reagent blank, (B) reaction mixture and (C) authentic biphenyls. Peaks: 1, BrPhCN derivative; 2, BrPhOCH 3 derivative; 3, BrPhCOOC 2 H 5 derivative; 4, BrPhCH 3 derivative; 1 4- phenylbenzonitrile; 2, 4-methoxybiphenyl. Sample concentration: 25 µm for all compounds. 14

Table 1 Fluorescence characteristics of the reaction products of aryl bromides with PBA Aryl bromide ex em RFI a BrPhCN 285 335 91 BrPhOCH 3 280 330 36 BrPhCOOC 2 H 5 290 350 100 BrPhCH 3 275 315 33 a Relative fluorescence intensity; BrPhCOOC 2 H 5 taken as 100 Table 2 Calibration curves and detection limits for aryl bromides Aryl bromide Calibration curve a Detection limit b, Range, µm Slope c Intercept c r 2 µm (fmol/injection) BrPhCN 0.008-50 25.12 ± 0.007 8.38 ± 0.52 0.999 0.003 (13) BrPhOCH 3 0.06-50 6.54 ± 0.53 0.65 ± 0.70 1.000 0.013 (67) BrPhCOOC 2 H 5 0.02-50 20.38 ± 0.36 7.30 ± 0.85 1.000 0.007 (33) BrPhCH 3 0.1-50 1.08 ± 0.03 0.44 ± 0.10 1.000 0.03 (157) a Peak height (cm) versus concentration (µm). b Detection limit at a S/N ratio of 3. c Data presented as mean ± S.E. of three experiments. 15