A R E S O N A N T D U M M Y L O A D

Similar documents
Resonant Matching Networks

ELECTROMAGNETIC OSCILLATIONS AND ALTERNATING CURRENT

Single Phase Parallel AC Circuits

MODULE-4 RESONANCE CIRCUITS

AC Circuits Homework Set

Radio Frequency Electronics

RLC Circuit (3) We can then write the differential equation for charge on the capacitor. The solution of this differential equation is

CHAPTER 22 ELECTROMAGNETIC INDUCTION

Electromagnetic Oscillations and Alternating Current. 1. Electromagnetic oscillations and LC circuit 2. Alternating Current 3.

1 Phasors and Alternating Currents

AC Circuits III. Physics 2415 Lecture 24. Michael Fowler, UVa

Supplemental Notes on Complex Numbers, Complex Impedance, RLC Circuits, and Resonance

Physics 240 Fall 2005: Exam #3 Solutions. Please print your name: Please list your discussion section number: Please list your discussion instructor:

Physics 4B Chapter 31: Electromagnetic Oscillations and Alternating Current

Alternating Current Circuits

Pre-Lab. Introduction

Capacitor. Capacitor (Cont d)

Impedance and Loudspeaker Parameter Measurement

RLC Series Circuit. We can define effective resistances for capacitors and inductors: 1 = Capacitive reactance:

MAGNETIC FIELDS & UNIFORM PLANE WAVES

Circuit Analysis-II. Circuit Analysis-II Lecture # 5 Monday 23 rd April, 18

Assessment Schedule 2015 Physics: Demonstrate understanding of electrical systems (91526)

The Farad is a very big unit so the following subdivisions are used in

Ch. 23 Electromagnetic Induction, AC Circuits, And Electrical Technologies

mywbut.com Lesson 16 Solution of Current in AC Parallel and Seriesparallel

Physics 405/505 Digital Electronics Techniques. University of Arizona Spring 2006 Prof. Erich W. Varnes

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur

y(d) = j

SINUSOIDAL STEADY STATE CIRCUIT ANALYSIS

EXPERIMENT 07 TO STUDY DC RC CIRCUIT AND TRANSIENT PHENOMENA

What s Your (real or imaginary) LCR IQ?

Consider a simple RC circuit. We might like to know how much power is being supplied by the source. We probably need to find the current.

Electric Machines I Three Phase Induction Motor. Dr. Firas Obeidat

General Physics (PHY 2140)

Core Technology Group Application Note 3 AN-3

General Physics II (PHYS 104) Exam 2: March 21, 2002

Chapter 33. Alternating Current Circuits

Electricity and Light Pre Lab Questions

3 The non-linear elements

ELECTRO MAGNETIC INDUCTION

RADIO AMATEUR EXAM GENERAL CLASS

To investigate further the series LCR circuit, especially around the point of minimum impedance. 1 Electricity & Electronics Constructor EEC470

Chapter 3: Capacitors, Inductors, and Complex Impedance

Physics 240 Fall 2005: Exam #3. Please print your name: Please list your discussion section number: Please list your discussion instructor:

MAY/JUNE 2006 Question & Model Answer IN BASIC ELECTRICITY 194

THE EFFECT OF DIELECTRIC INSIDE AN INDUCTANCE COIL

What happens when things change. Transient current and voltage relationships in a simple resistive circuit.

Slide 1 / 26. Inductance by Bryan Pflueger

Proceedings of the 13th WSEAS International Conference on CIRCUITS

Electrical Circuits Lab Series RC Circuit Phasor Diagram

Alternating Current. Symbol for A.C. source. A.C.

Assessment Schedule 2016 Physics: Demonstrate understanding electrical systems (91526)

Capacitors. Charging a Capacitor. Charge and Capacitance. L05: Capacitors and Inductors

EE 242 EXPERIMENT 8: CHARACTERISTIC OF PARALLEL RLC CIRCUIT BY USING PULSE EXCITATION 1

How to measure complex impedance at high frequencies where phase measurement is unreliable.

Chapter 32A AC Circuits. A PowerPoint Presentation by Paul E. Tippens, Professor of Physics Southern Polytechnic State University

Laboratory I: Impedance

Driven RLC Circuits Challenge Problem Solutions

1000 to pf (E3 series) Dielectric material K2000 K5000 K14000 Rated DC voltage 100 V 100 V 63 V Tolerance on capacitance ±10% 20/+50% 20/+80%

Impedance/Reactance Problems

An example of answers for the final report of Electronics"

AC Source and RLC Circuits

Chapter 30. Inductance

Module 4. Single-phase AC circuits. Version 2 EE IIT, Kharagpur

LCR Series Circuits. AC Theory. Introduction to LCR Series Circuits. Module. What you'll learn in Module 9. Module 9 Introduction

a. Clockwise. b. Counterclockwise. c. Out of the board. d. Into the board. e. There will be no current induced in the wire

Power Factor Improvement

Chapter 21 Lecture Notes

NMR Instrumentation BCMB/CHEM Biomolecular NMR

PROBLEMS TO BE SOLVED IN CLASSROOM

Alternating Current Circuits. Home Work Solutions

EXP. NO. 3 Power on (resistive inductive & capacitive) load Series connection

Lecture 4: R-L-C Circuits and Resonant Circuits

Sinusoidal Response of RLC Circuits

Electrical Engineering Fundamentals for Non-Electrical Engineers

Power and Energy Measurement

The Basic Capacitor. Dielectric. Conductors

INTC 1307 Instrumentation Test Equipment Teaching Unit 6 AC Bridges

Design of Narrow Band Filters Part 2

ECE 325 Electric Energy System Components 5 Transmission Lines. Instructor: Kai Sun Fall 2015

EE221 Circuits II. Chapter 14 Frequency Response

Name: Class: Date: Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Unit 21 Capacitance in AC Circuits

Voltage vs. Current in a Resistor, Capacitor or Inductor

Outline. Week 5: Circuits. Course Notes: 3.5. Goals: Use linear algebra to determine voltage drops and branch currents.

Lecture 5: Using electronics to make measurements

Content courtesy of Wikipedia.org. David Harrison, CEO/Design Engineer for Model Sounds Inc.

EE221 Circuits II. Chapter 14 Frequency Response

Solutions to PHY2049 Exam 2 (Nov. 3, 2017)

Determining Characteristic Impedance and Velocity of Propagation by Measuring the Distributed Capacitance and Inductance of a Line

Lecture 9 Time Domain vs. Frequency Domain

Short Wire Antennas: A Simplified Approach Part I: Scaling Arguments. Dan Dobkin version 1.0 July 8, 2005

04 Matching Networks. Dipl.-Ing. Dr. Michael Gebhart, MSc

Laboratory I: Impedance

CLUSTER LEVEL WORK SHOP

BASIC ELECTRONICS PROF. T.S. NATARAJAN DEPT OF PHYSICS IIT MADRAS LECTURE-3 ELECTRONIC DEVICES -II RESISTOR SERIES & PARALLEL

R-L-C Circuits and Resonant Circuits

HOW TO SOLVE YOUR ANTENNA MATCHING PROBLEMS

AC Circuit. a) Learn the usage of frequently used AC instrument equipment (AC voltmeter, AC ammeter, power meter).

PHYS 1441 Section 001 Lecture #23 Monday, Dec. 4, 2017

Transcription:

A R E S O N A N T D U M M Y L O A D By Luiz Amaral PY1LL/AC2BR Introduction Our specific problem is to build a dummy load for the 470-510kHz band for a 250W average output power transmitter for that band. An ideal dummy load presents a pure resistive impedance R and independent of the frequency. As it is difficult to be build with common carbon resistors 1, the suggested solution is to use an inductive load (using electric showers resistances, very common in Brazil, as in Figure 1) would form a series R-L circuit on that band of frequencies, with a capacitor C also in series to compensate for the inductive reactance. The impedance of the element R-L is, in the complex representation, Z RL = R + j,l.ω (j the imaginary unity, L the inductance and ω the angular frequency equal to 2.π.f, with f the linear frequency). In a less mathematical language, it means that R is the resistive or real component of the impedance and L.ω the reactive component, with R and L being independent of the frequency. The capacity C must be such to get the resonance, that is, its reactance -1/(ω.C) must be equal to L.ω in module so that we get a total reactance equal to zero and therefore a constant resistive impedance equal to R. The chosen solution For simplicity I decided to choose the simplest solution to control: to use wire resistors even if it creates an inductive load. At least in Brazil, it is cheap and very easy to find wire resistors for electrical showers, in my case, the brand Lorenzetti model Max-Ducha that is split in two parts for the operations winter and summer (as common in such showers) as in Figure 1. 1 The referred difficulty is due the high price of high dissipation non-inductive carbon resistors. The price of commercial dummy loads for higher power is also high.

Combining 5,500W and 4,400W resistances for 220V it is possible to get a total resistance value of 50Ω with a tolerance of 2% with two longer parts of the 5,500W resistance and two full 4,400W resistances. Once assembled the circuit with the referred resistance combination, it was adjusted for 50Ω with an alternating voltage of 60Hz. However two problems arose when trying to use the dummy load on 500kHz band with the resonance capacitor: 1 The resistive component value was much greater than 50Ω. 2 The calculated capacitor value to get resonance by measuring the reactive inductance also was well different from the practical one, that is, the resonant frequency was very far from the expected. A deeper study showed that the problems occurred due the skin effect of the conductor, increasing the resistance with frequency and also due a very important distributed capacitance γ of the resistive coil. The equivalent circuit may be simplified as in Figure 2. R γ L FIGURE 2 The existence of that distributed capacitance γ complicates too much the impedance Z of the circuit that now has a real component r different from R and dependent 2 of γ, ω and L (see Appendix). Z = R(ω) / [(1 - ω 2. L. γ) 2 + ω 2. R 2 (ω). γ 2 ] [I] Note that, if we make γ = 0 in [I], we get r = R(ω), as we must expect for the ideal case with no distributed capacitance. Here a test was performed for verifying if our problem was really due that distributed capacitance. If we stretch the coil wire (it has a helical spring behavior), both the inductance L and the capacitance γ vary and r also varies (as the total wire length doesn t change, the value of R(ω) stays constant). But, if we introduce into the coil a ferrite core, L varies, with R(ω) and γ kept constant. If r now varies, it is due the first term of the denominator of Z, as its second term and the numerator don t vary. The experiment was performed showing that r depends of L and is crescent with it, what justifies an expression for Z as in [I]. This shows that there is a strong dependence between r and L due the distributed capacitance γ. The solution therefore is to make γ and L as smaller as possible. To diminish L, I tried to wind the resistive wire with the odd windings in one direction and the even ones in the opposite direction (coiling with alternate windings inverted) on a pavement ceramics plate. This also affects the distributed capacitance γ. It exists obviously a trade-off between L and γ minimizations, not always easy to quantify. One problem of such winding method is that its ends are on opposite points of the coil, making its bond to the coaxial connector rather difficult. Another way to wind the wire is showed in Figure 3 3, where the ends are close, making easy the physical mounting of the system with the capacitor C and the connector. For the adjustment ease, I used a shorting bar for trimming the value of the resistance r (50Ω in our case). In the working frequency we slide the shorting bar to adjust r. The capacitor C is mounted on the same ceramics insulating base and as a padder 4, adjusted to get the resonance of the device, that is, C must show 2 This dependence in ω has two sources, the indirect by the skin effect, explicit in the form R(ω), and the direct one by the denominator of the expression [I]. 3 This was suggested by Gilson, PU5MPL. 4 The capacitor was assembled on a homemade basis, as the existent in the 500kHz transmitter project, as a published article of the same author.

Pavement ceramics plate Sliding shorting bar Double inverted windings FIGURE 3 a reactance to compensate for the inductive reactance X of the coil given by the imaginary component of the expression [I]. When adjusting C, may be we have to reposition the shorting bar for a fine adjust of the value of r. So, with two adjustable elements (shorting bar and C) we can obtain resistive impedance with the desired value (50Ω) with good precision. In practice we verified that the coiling of Figure 3 showed values very similar to those with inverted alternate turns, but with much more assembling ease. Figure 4 shows the result obtained after the adjustment of both elements to get resonance on 504kHz (the frequency of the programmed test transmissions). We can see the curves of r (formed by small squares) and of X (formed by small circles) in function of the frequency since 470kHz up to 510kHz. We verify that they vary too little as the table below:

Frequency (khz) r (Ω) X (Ω) 470 48.21-6.14 (equivalent to a 55.12nF capacitor) 504 50.05 0.13 (equivalent to a 41nH inductor) 510 50.29 1.18 (equivalent to a 0.37µH inductor) There is no need therefore for retuning of the dummy load when we go through the entire band, though we can do it. Figure 4, however, shows on the vertical line the frequency of 502.15kHz (chosen randomly in the band), where the resistive and reactive components are Rs and Xs, this capacitive and equivalent to a capacity Cs. Figure 5 shows the equivalent circuit with the capacitor C inserted and that resonates with X. C r X FIGURE 5 Figure 6 shows the photo of the ceramic plate assembled with the female connector (PL-259) but without the capacitor and Figure 7 its bottom view. For the measurements were used an antenna analyzer model AIM-4170 from Array Solutions, a function generator model MFG-4202 from Minipa (Brazilian) with output impedance equal to 50Ω and an oscilloscope model V-223 from Hitachi. The measurements with the function generator and oscilloscope was based on the fact that, when the load of a non-inductive load is equal to that of the generator, we have a voltage divider by a factor of 2, that is, with the load connected, the voltage must be one half of that of the open circuit (with no load). These results were perfectly confirmed by using the antenna analyzer.

Figure 8 shows the dummy load ready with its resonance capacitor. The AIM-4170 was used for observe the resonance by adjusting the four bolts of the capacitor (that we see in Figure 8) that adjust its capacity and the shorting bar position that adjusts the resistive component, normally 50Ω on the frequency of interest. It is possible to exist some interaction between both adjusts, that is, after adjusting one parameter, it is possible to trim the other one until the bets result is obtained (this is mainly due the residual existence of a distributed capacitance of the coil). It is important to remember that all adjustments must be done far from metallic surfaces to avoid undesirable interactions that can modify the values of the parameters. Conclusion The presented solution was the construction of a resonant load (narrow band) to replace a high cost high power resistive load (broad band). The usable band of the load, in practice, is far greater than the necessary to cover the band of our interest from 470kHz to 510kHz, especially with the use of a padder capacitor together a shorting bar (the system may be retuned to be adapted to the recently IARU approved 472-479kHz band). As our load was mounted with more than one electrical shower resistive devices, because it is cheap and easy to get in the market 5, splices on the wire were necessary. For greater stability, all splices were soldered with tin. For this, it was necessary to scrape the wire ends to be soldered and twist them for mechanical strength and smaller the temperature of the splices to avoid solder melting during real operation. The preparation was made with a special flux (developed for aluminum, but working fine with resistive nickel alloys), from Brasweld (Brazilian) called Alutin. In an electric shower for 220V and 5,500W, that uses the chosen wire, the current is 25A. Under 110V, the current is 43A. With 450W average power (much greater than the 250W of my transmitter), the current would be 3A, therefore the expected temperature for the wire is very low, in special on the splices where the volume is bigger and the heat doesn t jeopardize the tin solders. Appendix The impedance Z of the circuit of Figure 2 is given by: Z = (R + j. ω. L) / (1 - ω 2. L. γ + j. ω. R. γ) This expression can be written as: Z = {R + j. ω. [L. (1 - ω 2. L. γ) R 2. γ]} / [(1 - ω 2. L. γ) 2 + ω 2. R 2. γ 2 ] Taking the resistive r and reactive X components: r = R / [(1 - ω 2. L. γ) 2 + ω 2. R 2. γ 2 ] X = j. ω. [L. (1 - ω 2. L. γ) R 2. γ] / [(1 - ω 2. L. γ) 2 + ω 2. R 2. γ 2 ] When γ is small, we may write: r = R / (1 2. ω 2. L. γ) When expanding the coil increasing its length, γ is a crescent function with L and therefore the expression 1 2. ω 2. L. γ decreases with L, increasing r. So, if only L is varied (with a ferrite) and r varies less than the process of the coil expansion, it means that γ > 0 and is important in the process. 5 The assembling is simpler with the use of 0.75mm diameter nickel-chrome wire got in the market because it has less puckers and doesn t need splices.