Electrodes - Connect/Replace. Reagents - Install/Replace. Select method ph electrode calibration. Reagent calibration.

Similar documents
Reagents - Install/Replace. Select method/sequence. KF Reagent calibration Running KF titration methods. Running SAC sequences

Electrodes for ph measurements. - when you need to be sure...

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

BIOGAS Titration Manager

Automatic titrators, TitroMatic

Titration Workstations

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

Fig. Electrochemical Cell/ Potentiometric Titration

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

ph Probe ReallyEasyData com

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA. Background

TitraLab 580 and 585. KF Titration Workstations. Reference Manual D21T083

symphony Reference Electrodes

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

TitraLab 870. Reference Manual. ph/ep/ip/ec/ise Titration Workstation D21T060

Operating Instructions for Ammonium ISE Specifications

USER MANUAL. Aquamax TAN

Titration of a strong acid with a strong base with Cobra4

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

Karl Fischer Volumetric Titration Theory and Practice

POTENTIOMETRIC TITRATIONS & SOLUBILITY EQUILIBRIA

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

Concise laboratory catalogue

ION570. Reference Manual. Ion Analyser D21M073

TitraLab 854 and 856. ph-stat Titration Workstations. Reference Manual D21T054

symphony Multisensor Probes

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

PH700 Benchtop ph Meter Instruction Manual

Experimental Procedure. Lab 406

ION570. Reference Manual. Ion Analyser D21M073

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

User Manual. Compact Titrator G10S/G20S

Volumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Bante210 Benchtop ph Meter Instruction Manual

Reference Electrode Salt Bridge Kit

Chemistry MultiMeasure Sensor PS-2170

Experiment C-10 Titration of a Strong Acid and a Strong Base

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

MassWWP Standard Operating Procedure L-6 ph and Alkalinity Rev.0 Page 1 of 12

425 Jordan Road SOP. No. 10 Rev. No. 1.3 Troy, NY Date: 03/14/2012 Page 1 of 7

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

From 1 ppm to 100% Karl Fischer water content determination

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Easy and reliable KF titrations From 1 ppm to 100%

Mobile coulometer for water determination anywhere you want

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Acid-Base Titration. Evaluation copy

Electrochemistry LEC Potentiometric ph titration (phosphoric acid in a soft drink) What you need: What you can learn about

6 Acid Base Titration

INTRODUCTION TO ACIDS, BASES AND TITRATION

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

Titration Catalog. Systems and Autosampler

Manual ph Probe & Oxidation Reduction Potential Probe Models 6528A and 6528B

Guide to ph Analysis.

Conductometric Titration & Gravimetric Determination of a Precipitate

Karl-Fischer Titration the method for determining water

STANDARD OPERATING PROCEDURE

WATER ANALYSIS The ph Value. The Redox Potential. ALMEMO ph and Redox Measurement. The Electrical Conductivity

Automatic Potentiometric Titrator

Acid-Base Titration. Sample

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Chemistry Potentiometric Titration of a Chloride-Iodide Mixture

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

iworx Sample Lab Experiment GB-2: Membrane Permeability

Karl Fischer Titrator

Nanotechnology Sensors

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator

Determining the K sp of Calcium Hydroxide

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant

Operating Instructions. EasyPlus Titration Easy ph / Easy Ox / Easy Cl / Easy Pro

Mixtures of Acids and Bases

Titration of Acids and Bases

12.01 Determination of the isoelectric point of an amino acid (glycine)

INE-DDB-303A Portable Conductivity Meter Instruction Manual

Acid-Base Titration. Volume NaOH (ml) Figure 1

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

ph Electrode basics ph Electrodes Model 19 B /1 =1 m 24 B /1 =1 m

ACID-BASE TITRATION (MICROSCALE)

User instructions. Gel filled ORP/Redox electrode: Model MTC10101, MTC10103, MTC10105, MTC10110, MTC10115 or MTC10130

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Related concepts Electrolyte, electrical conductance, specific conductance, ion mobility, ion conductivity, conductometry, volumetry.

Chematest 25. Operator s Manual A Swan Analytical Instruments AG CH-8340 Hinwil/Switzerland ANALYTICAL INSTRUMENTS

To explore solubilities and reactivities of different metal ions. To identify ions present in unknown solutions using separation methods.

Potentiometric measurement of ph

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Compact ph Measuring Instruments With Pro Engineering

KEM SET. for Beverage. Gas volume Internal gas pressure Air content Oxygen concentration Inside pressure Density Brix

Transcription:

Short-For t-form Reminders Electrodes - Connect/Replace Reagents - Install/Replace Select method ph electrode calibration Reagent calibration Running methods Running sequences Direct measurements Maintenance recommendations Storage recommendations Spare parts & accessories Electrodes Calibration standards & solutions D2T066 Printed by Radiometer Analytical SAS 2008-09B Short-Form Reminders

Short-Form Reminders 2

Only one key press to check the electrodes in use! Electrodes - Connect/Replace Form no. and 2 Select method Electrodes to be connected Install electrode system GND Temp Pt-Pt Ref E Socket Electrode REF Single reference electrode TEMP Temperature sensor GND Single metal electrode Pt-Pt Double metal electrode E/E2 Other electrode types Example: phc240-a to address TIM/E (socket E on rear panel).

To replace reagents, use the reagent installation procedure Reagents - Install/Replace Form no. 2 and 2 Select method Install reagent system. Enter Reagent window 3. If required, rinse burette 2. 2 then 4. Install reagent bottle and press to flush then if another reagent is already installed

Straightforward method selection Select method Form no. 3 Select method. Enter main 2. 2 Select method menu from list Confirm Check icons You can run the method You can run the method. However a calibration must be performed soon Check the reagents for installation or calibration purposes. Check the electrodes and reagents for calibration purposes Programming error due to missing parameters

Calibrate your electrode ph electrode calibration Form no. 4 Run calibration. Enter Electrode 2. window 3. To run the calibration 4. Enter User ID and temperature, if required, and confirm 5. Rinse electrode(s) and dip in beaker 6. The measurement starts Confirm Calibration can be performed on up to 5 buffers.

Automatic result display Press to save results Results: zero ph and sensitivity View statistics 2 then 2 More cycles/end of analysis Emergency stop Stop Resume analysis

Calibrate your reagent Reagent calibration Form no. 5 Select reagent. Enter Reagent window 2. then to select reagent from list 3. Confirm Run calibration. To run the calibration 2. Enter User ID and temperature, if required, and confirm

3. Enter standard amount then confirm 4. Rinse electrode(s) and dip in beaker 5. Confirm 6. The measurement starts Automatic result display Press to save result View statistics 2 then 2 Stop More tests/end of analysis Resume analysis Emergency stop

Run your analyses Running methods Form no. 6 Run. To run your selected method 2(*). Enter User ID and temperature, if required, and confirm 3(*). Enter Sample ID, sample amount and confirm 4(*). Rinse electrode(s) and dip electrode(s) in beaker then confirm 5. The measurement starts (*) In Run sample start = Shortcut mode, steps 2, 3 and 4 and are chained automatically:. Rinse and dip electrodes in beaker. 2. To start measurements.

Automatic result display (*) Press to save results (*) In Run sample end = Shortcut mode, this window does not appear and the results are displayed. View statistics (*) 2 then 2 (*) In Run sample end = Shortcut mode, this window does not appear. More tests/end of analysis (*) Running new tests/samples in Run Sample start = Shortcut mode: Rinse and dip electrodes in beaker then or 2 (*) In Run sample end = Shortcut mode, this window only appears if several sample replicates have been edited for the method. Stop Del Emergency stop Resume analysis. To resume analysis. Calculations are not performed To end an analysis before the maximum titration time or the maximum volume have been reached. Calculations are performed, if result found

Use your Sample stack for daily analyses Running sequences Form no. 7 Preparing the sample stack. 3 XYZ + 5. Place beaker no. onto the sample changer turntable. 6. 2. Enter a new sample ID and confirm Repeat steps 2 to 5 for each beaker in the sequence 7. Esc then Esc 3. Check the sample test quantity or enter the sample test quantity to place in beaker no. + 4. Confirm

Run SAC sequence. 2(*). Enter User ID and temperature, if required, confirm (*) In Run sample start = Shortcut mode, step 2 is skipped. Emergency stop Stop Resume analysis. To repeat measurements in the same beaker. Stop 2 Next analysis. To start measurements in the next beaker. Stop Del 2 End of analysis. To stop the sequence. To end an analysis before the maximum titration time or the maximum volume have been reached. Calculations are performed, if result found.

A? in the Electrode tab? Check your programming Direct measurements Form no. 8 Live measurements. Select method and 2 2. Connect the electrode(s). See form no. 3. Dip electrode(s) in beaker 4. Enter Electrode menu and 2 5. To select an electrode and display measurements 6. Esc To stop measurements

For burette air bubble removal, run the Flush procedure Maintenance recommendations Form no. 9 Daily Check and maintain electrodes according to manufacturer recommendations. Check that there is no crystallisation at piston level, if so rinse the burette using appropriate solvent to remove crystals. If not sufficient, dismount burette to remove crystals. Check that there is no crystallisation at addition tip end that may block the reagent to pour freely, if so use appropriate solvent to remove crystals. Check the level of reagent in the reagent bottle Empty waste bottle if installed. Remove air bubbles from the burette and tubing by running a Flush procedure from the burette menu. Weekly Reagent glass cylinder piston Reagent Flush the burette with appropriate solvent to ensure complete cleaning of burette and stopcock. Change burette stand Check the piston for leakages. The burette stand must be changed when liquid can be seen between the two sealing lips. Refer to diagram.

Annualy Replace burette stand,, 5, 0, 25, 50 ml and the anti-diffusion tip, part. no.956-309. Frequent use or use with aggressive or concentrated reagents occurring crystallisation risks may severely reduce the burette and anti-diffusion tip lifetime and may consequently require to replace them more frequently. Replace burette stand set of 3 tubing, (stands 5, 0, 25, 50 ml, part number X3T5 and stand ml, part number X3T6). Replace damaged burette accessories: bottle stopper, desiccant tubing. Contact your Radiometer Analytical representative for instrument revision and cleaning. Recommendations of use After installing new burette and/or tubing, before use, check that all tubing fittings are sufficiently tightened to prevent leakage, and that no tubings are crimped (do not over tight fittings) The reagent should be at room temperature before use in the burette. Do not leave burette installed with concentrated base, acid or salt solutions. Always rinse after use, at least daily, to increase stopcock and burette lifetime. Organic solvents: the organic solvents given as reacting with and/or destroying the VITON (Fluorinated polymer) should not be used with our burette stands (example: TetraHydroFurane). The solvents given as simply making inflate the VITON are allowed. Please contact us if you wish to work with solvents destroying the VITON.

Keep your system in tiptop condition! Storage recommendations Form no. 0 Daily Rinse electrodes and delivery tip throughly with distilled water after use. Store the electrode(s) following the instructions given in the respective operating instructions. Overnight and up to week In case of spillages, clean the exterior surface of the instrument with a soft cloth and tepid water. Avoid the accumulation of excess water around the keyboard area. Long-term week or more Run the Remove burette procedure from the Burette menu to remove reagent and rinse burette and tubings. If the system is to be left in the same location, store electrode(s) following the long-term storage instructions given in the respective operating instructions. If the system is to be transported, dismount the burette stand, metal rod, and cell accessories before packing. For transportation, always use the packaging supplied by the manufacturer.

Ordering information at a glance Spare parts & accessories Form no. Part no. Type Description X5T025 X5T026 X5T07 X5T027 X5T028 Burette stands B50 Burette Stand, ml, UV protected with connection tubing B505 Burette Stand, 5 ml, UV protected with connection tubing B50 Burette Stand, 0 ml, UV protected with connection tubing B525 Burette Stand, 25 ml, UV protected with connection tubing B550 Burette Stand, 50 ml, UV protected with connection tubing X3T069 X3T070 X3T0 Replacement parts Delivery tubing with anti-diffusion tip Titrant bottle stopper GL45 assembly with desiccant & suction tubing Titrant bottle stopper GL45 assembly with desiccant & suction tubing for B50 450-020 Fuse, slow blow,.0a, (5 x 20 mm) 92-034 D402, Stirring Magnet, L = 20 mm S72T004 Molecular Sieve, 250 g X3T5 Maintenance Kit of 3 tubes for B5xx (excl, B50) X3T6 Maintenance Kit of 3 tubes for B50 only Polypropylene titration vessels 904-490 Titration Vessel, PP, 40-00 ml (pack of 50 pcs) 904-489 Titration Vessel, PP, 22-45 ml (pack of 50 pcs) 904-488 Titration Vessel, PP, 8-25 ml (pack of 50 pcs) 904-487 Titration Vessel, PP, -9 ml (pack of 50 pcs)

Part no. Type Description Notebook keyboard X3T08 X6T005 X6T006 X6T007 X6T008 X6T009 X6T00 X6T0 Notebook Keyboard Mask Notebook Keyboard 83-keys, PS/2 port, US version Notebook Keyboard 83-keys, PS/2 port, French Notebook Keyboard 83-keys, PS/2 port, German Notebook Keyboard 83-keys, PS/2 port, Danish Notebook Keyboard 83-keys, PS/2 port, Spanish Notebook Keyboard 83-keys, PS/2 port, Italian Numeric Keypad, PS/2 port Balance connecting cables A95Z20 C20Z 9pf/m/25pm (Mettler PE + option 06; Mettler AE + option 02 or 0) A95Z205 C205Z 9pf/2m/25pm (Mettler PE + option 06; Mettler AE + option 02 or 0) A95Z206 C206Z m serial cable for Mettler AM, PM, SM, AT, MT, UMT, PJ, AJ A95Z202 C202Z 9bf/m/25bm (Sartorius MasterPro, QC, MP8-4) A95Z204 C204Z 9bf/2m/25bm (Sartorius MasterPro, QC, MP8-4) A95Z207 C207Z 9pf/.20m/25pm (Precisa, old models) A95Z208 C208Z 9pf/m/RJ45 (Precisa, XB series) For other balances, please consult.

Ordering information at a glance Electrodes Form no. 2 Part no. Type Description Combined ph/reference electrodes Acid/Base titrations E6M33 phc200-8 Combined ph electrode, Red Rod, porous pin junction E6M400 phc240-8 Combined ph electrode, Red Rod, annular junction E6M500 phc2005-8 Combined ph electrode, Red Rod, epoxy body protection E6M50 phc2085-8 Combined ph electrode, Red Rod, with temperature probe E6M300 phc300-8 Combined ph electrode, Ag/AgCl, porous pin junction E6M302 phc3005-8 Combined ph electrode, Ag/AgCl, epoxy body protection E6M305 phc308-8 Combined ph electrode, Ag/AgCl, with temperature probe Single ph electrodes EM006 phg20-8 Glass ph electrode, ø = 7.5 mm, general purpose EM003 phg2-8 Glass ph electrode, ø = 7.5 mm, alkaline samples Combined Metal/Reference electrodes RedOx & Precipitation titrations E3M003 MC305Pt-9 Combined Platinum electrode, Ag/AgCl Ref., Screw cap * E34M004 MC609Ag-9 Combined Silver electrode, Hg/Hg 2 SO 4 Ref., Screw cap * * For use with connection cable, type CL4, part no. A94L4 Single Metal electrodes E34M003 M295Ag Silver Rod, ø = 7.5 mm, PTFE body, banana plug ** E3M00 M24Pt Platinum Plate, ø = 7.5 mm, glass body, banana plug ** ** For use with adapter, type BNC-m/Banana-f, part no. A94P807 Temperature Sensor E5M00 T20 Temperature Sensor, glass

Part no. Type Description Pt-Pt Metal electrodes E32M00 M23Pt2 Double platinum wire, 2 banana plugs *** E32M002 M24Pt2-8 Double platinum staples, short cable *** For use with adapter, type BNC-f/2 Banana, part no. A94P80 ISE electrodes Complexometric & Precipitation titrations E4M002 ISE25Ca Ion Selective Electrode, Calcium, Screw cap * E4M003 ISE25Cl Ion Selective Electrode, Chloride, Screw cap * E4M006 ISE25Cu Ion Selective Electrode, Copper, Screw cap * E4M007 ISE25F Ion Selective Electrode, Fluoride, Screw cap * E4M07 ISEC30F Combined Ion Selective Electrode, Fluoride, Ag/AgCl ref., Screw cap * * For use with connection cable, type CL4, part no. A94L4 Single Reference electrodes E2M009 REF20 Reference Electrode, Red Rod, ø = 7.5 mm, banana plug ** E2M0 REF40 Reference Electrode, Calomel, ø = 7.5 mm, banana plug ** E2M02 REF60 Reference Electrode, Mercurous Sulphate, ø = 7.5 mm, banana plug ** E2M00 REF25 Reference Electrode, Red Rod, double junction, banana plug ** ** For use with adapter, type BNC-m/Banana-f, part no. A94P807

Ordering information at a glance Calibration standards & solutions Form no. 3 Part no. Type Description IUPAC Series ph Standards SM00 ph.679 ph.679 ±0.00 at 25 C, 500 ml SM002 ph 4.005 ph 4.005 ±0.00 at 25 C, 500 ml SM003 ph 6.865 ph 6.865 ±0.00 at 25 C, 500 ml SM004 ph 7.000 ph 7.000 ±0.00 at 25 C, 500 ml SM005 ph 7.43 ph 7.43 ±0.00 at 25 C, 500 ml SM006 ph 9.80 ph 9.80 ±0.00 at 25 C, 500 ml SM007 ph 0.02 ph 0.02 ±0.00 at 25 C, 500 ml SM008 ph 2.45 ph 2.45 ±0.05 at 25 C, 500 ml 4-7-0 Series SM02 ph 4 ph 4.00 at 25 C, 500 ml SM03 ph 7 ph 7.00 at 25 C, 500 ml SM04 ph 0 ph 0.00 at 25 C, 500 ml Electrode Maintenance Solutions S6M00 RENOVO N Normal Cleaning Solution, 250 ml S6M002 RENOVO X Xtra Strong Cleaning Solution, 250 ml C20C370 KS400 Pepsin in HCl Cleaning Solution, 250 ml C20C380 KS40 Thiourea Solution, 250 ml, for junction cleaning C20C300 KS00 KCl Solution, saturated, 500 ml, for Red Rod & Calomel reference C20C500 KS60 K 2 SO 4 Solution, saturated, 500 ml, for Hg/Hg 2 SO 4 reference C20C30 KS20 KCl Solution, saturated with AgCl, 500 ml, for Ag/AgCl reference S2M00 KCl C KCl Crystals, 5 g S9M00 GK ANNEX Electrode Maintenance Kit for ph & reference electrodes