APPENDIX I. Line T-198, Structures , over the Ashuelot River, Swanzey, NH

Similar documents
DE PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE

Tennessee Valley Authority. Thermal Assessment of Existing 161kv & 500kv Transmission Lines

Electric Distribution Storm Hardening Initiatives. Paul V. Stergiou Distribution Engineering October 14 th, 2015

1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-cur

188 Equating the moments of above two forces about point O, we get, T y = w x x or y = w x T The maximum dip (sag) is represented by the value of y at

APPENDIX A DEFINITIONS, NOTATIONS, AND SI CONVERSION FACTORS

DISTRIBUTION CONDUCTOR STRINGING EQUIPMENT & TECHNIQUES

EECE421 Power System Analysis. Chapter 4: Transmission Line Capacitance

Composite Conductor Field Trial Summary Report: Western Area Power Administration FARGO

Aerial Power Cables Profile, Sag and Tension Calculations Jorge R. López, MSME, PE José A. López, MSCE, PE

SIGNIFICANCE OF TRANSPOSITION FOR 220KV TOWER

Increasing Transmission Capacities with Dynamic Monitoring Systems

Modern techniques of ice-load assessment and icing maps creation for the design of overhead transmission lines used in the Russian Federation

Calculations of Capacitance for Transposed Bundled Conductor Transmission Lines

CALCULATION OF POWER FREQUENCY FIELDS FROM HIGH VOLTAGE OVERHEAD LINES IN RESIDENTIAL AREAS

Multi Hazard Evaluation of a High Voltage Transmission Network. John Eidinger 1 and Leon Kempner 2

Arak. Power T ransmission Lines. 45 kv

2/23/ WIND PRESSURE FORMULA 2. PERCENT OF ALLOWABLE STRESS 3. FATIGUE DESIGN

BEFORE THE NEW MEXICO PUBLIC REGULATION COMMISSION

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK

URD Cable Fault Prediction Model

Continuing Education Course #207 What Every Engineer Should Know About Structures Part B Statics Applications

1. Major streets, Central Business District (CBD) and school bus routes. 2. Local streets 3. Downtown parking lots

PROCEDURE NO.: SO5-2-6 PAGES: 1 OF 10 CHIEF SYSTEM OPERATOR

KINECTRICS NORTH AMERICA INC. TEST REPORT FOR 774-KCMIL 3M TM COMPOSITE CONDUCTOR

Network Quality and Reliability of Supply

Equilibrium in Two Dimensions

Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur

HIMARC Simulations Divergent Thinking, Convergent Engineering

ARCH 614 Note Set 2 S2011abn. Forces and Vectors

Conductor Replacement Strategy. Eric Desjardins, EIT Hamdy Khalil, P. Eng., PMP Asset Management - BCTC

ACCELERATED ELECTRICAL AND MECHANICAL AGEING TESTS OF HIGH TEMPERATURE LOW SAG (HTLS) CONDUCTORS

Engineering Specification

EGR 1301 Introduction to Static Analysis

How Power is Restored After a Severe Storm. Presented by Stacy Shaw, Safety Director & Nolan Hartzler, GIS Mapping Technician

OPALCO Outage Analysis. December 2017 Board Meeting

USGS Flood Inundation Mapping of the Suncook River in Chichester, Epsom, Pembroke and Allenstown, New Hampshire

TRANSMISSION LINES. All aluminum alloy conductor (AAAC) Aluminum conductor alloy reinforced (ACAR)

G.SRT.C.8: Using Trigonometry to Find an Angle 2

Director, Operations Services, Met-Ed

LOCAL CLIMATOLOGICAL DATA Monthly Summary November 2006

Temperature calculations and LiDAR positions

The Hardening of Utility Lines Implications for Utility Pole Design and Use

ENVG/SC 10110L-20110L PLANET EARTH LABORATORY. Laboratory #9: Surface Hydrology & Map Scale

Composite Conductor Field Trial Summary Report: Western Area Power Administration Phoenix

Vegetation Related Transmission Outage Report

LOCAL CLIMATOLOGICAL DATA Monthly Summary July 2013

Evaluation of the risk of failure due to switching overvoltages of a phase to phase insulation

LOCAL CLIMATOLOGICAL DATA Monthly Summary September 2016

Which expression gives the elastic energy stored in the stretched wire?

Aid to Critical Infrastructure and Key Resources During a Disaster. Pete Grandgeorge MidAmerican Energy Company

A. leg B. hipponamoose C. hypotenuse D. Big Guy. A. congruent B. complementary C. supplementary D. cute little things

ECE 325 Electric Energy System Components 5 Transmission Lines. Instructor: Kai Sun Fall 2015

NEWTON S LAWS OF MOTION (EQUATION OF MOTION) (Sections )

, passing through the point 4, 2

Snow Measurement Guidelines for National Weather Service Snow Spotters

HELIODYNE SOLAR COLLECTOR RACK STRUCTURES FOR HELIODYNE, INC. Structural calculations. Gobi 410 at 45 degrees. for WCM HELIODYNE RACK

Universal bumper to frame hitch for 27,000 33,000 lbs. GVWR trucks. Optional: carbide cutting edge, mushroom shoes, snow deflectors

Saganashkee Slough - McMahon Woods Section 506 Great Lakes Fishery & Ecosystem Restoration Study

CLIMATE CHANGE ASSESSMENT. A. Climate Change Risk Assessment and Adaptation Measures

A Novel Approach for Increasing the Reliability of Power Transmission Lines in Galloping Conditions

Reliability of Transmission Towers under Extreme Wind and Ice Loading

Math 2 Trigonometry. People often use the acronym SOHCAHTOA to help remember which is which. In the triangle below: = 15

Introducing GIS analysis

7.6 Journal Bearings

Town of Oconomowoc Snow & Ice Control Policy

IMPERIAL COUNTY PLANNING AND DEVELOPMENT

ANALYSIS OF DIFFERENT DYNAMIC LINE RATING SYSTEM CONFIGURATIONS IN A DISTRIBUTION LINE

Designing wire-rope tramways

elgian energ imports are managed using forecasting software to increase overall network e 칁 cienc.

6.5 Cables: Concentrated Loads

PW 001 SNOW REMOVAL AND SANDING FOR ROADWAYS AND SIDEWALKS October 6, 2014 (#223-14) Original October 19, 2015; October 15, 2018 Public Works

EE115C Winter 2017 Digital Electronic Circuits. Lecture 6: Power Consumption

Miami-Dade County Overview

Civil & Structural Engineering Design Services Pty. Ltd.

SMALL VIOIHUXHGS. What Is Electricity?

EQUATIONS OF EQUILIBRIUM & TWO- AND THREE-FORCE MEMEBERS

6 INCH W X 5-3/4 INCH D X 8-3/8 INCH H

The Steady Magnetic Fields

St. Vincent College PH : General Physics II. Exam 5 4/8/2016

Severe Weather Watches, Advisories & Warnings

1. Departmental Presentation - Away Goes Trouble Down the Drain - Highway Division. 3. Continued Discussion an Ordinance for Disorderly Residences

Project Charter. $58,000 See attached budget report. shapefile to track poles and pole attachments. Poles are defined as a support structure on

Daily Operations Briefing. Monday, April 2, :30 a.m. EDT

Review of. Florida s Investor-Owned Electric Utilities Service Reliability reports. State of Florida

Dalton Highway Flood - Disaster in the Arctic

OVERHEAD DESIGN MANUAL

Numerical Calculation and Analysis on the Surface Electric Field Characteristics of Hot-Line Robot

JOINT U.S.-CANADA POWER SYSTEM OUTAGE TASK FORCE

THUNDERSTORM/STORM PROCEDURE

Town of Windsor. Department of Public Works

EE301 RESISTANCE AND OHM S LAW

EPRI Lightning Protection Design Workstation

ENGR-1100 Introduction to Engineering Analysis. Lecture 13

Chapter 4 DYNAMICS: FORCE AND NEWTON S LAWS OF MOTION

Tension, Compression, and Shear

Exam IV, Magnetism May 1 st, Exam IV, Magnetism

Static Equilibrium and Elasticity. Luis Anchordoqui

Flood Hazard Zone Modeling for Regulation Development

AS COMPETITION PAPER 2007

Transcription:

APPENDIX I Line T-198, Structures 122-123, 123-124 over the Ashuelot River, Swanzey, NH 1. The location of this crossing is shown on the attached location map marked as Exhibit Ii. 2. The design and proposed construction of this crossing is shown on the attached PSNH Transmission Drawing entitled PROPOSED ADSS LINE, 115 kv. LINE T-198, MILE 10, STR 122-123, 123-124, ASHUELOT RIVER WATER CROSSING, SWANZEY, NEW HAMPSHIRE. (Drawing No. D 7649-511) marked as Exhibit 12. For the Span between STR 122-123 3. Line T-198 crosses the Ashuelot River on H frame wood tangent structures with a span of 420 feet. The largest water width is 82 feet at time of survey. A detail of this structure~has been provided with this Petition as FIGURE 1. Minimum distances to ground for truck traffic of 15.5 feet for the ADSS and 20.1 feet for 115kV open supply per the NESC have been met as 20.6 and 24.2 feet of clearance is provided respectively for the AIJSS and the conductor wires. 4. Surface water elevations for the Ashuelot River were based on information contained in NH GRANIT, which references FEMA information. The normal flood level for this crossing is approximately 460.2 feet. The surface area of the crossing, as required by the NESC (Section 232, Note 19), is approximately 1.6 acres. This is based on the total area of the river for a 1- mile stretch in either direction of the crossing that includes the crossing based on FEMA digital maps and FEMA identified river boundaries. A GIS tool (ESRI ArcView) was used to calculate the surface area polygon. As stated in paragraph 6 of this petition, the minimum required clearances for 115 kv conductor and ADSS cable over water surface areas less than 20 acres is 22.1 and 17.5 feet, respectively. 5. As stated in NESC Table 232-1 Note 18, the surface area shall be enclosed by its high water mark and clearances shall be based on the normal flood level. In this case, the final river elevation at this location during the normal flood is 460.2 feet. As stated in paragraph 6 of this petition and paragraph 4 of this Appendix, the minimum required clearances for 115 kv conductors and ADSS cable over water surface areas less than 20 acres is 22.1 and 17.5 feet, respectively. The sags and clearances to the water surface are as follows:

Shield wires - Due to the fact that the static wires are located above the phase wires, its clearances to the water surface will always exceed the minimum required NESC distance. Conductors (phase wires) The maximum conductor sag for the NESC Heavy Loading weather case is always less than the 285 deg F maximum operating temperature (phase wires) based on PSNH transmission standards. The 285 deg F condition produces the greatest sag in the phase wires and therefore the minimum clearance to the water surface. This design will exceed the minimum clearance requirement of 22.1 feet with a clearance of 27.4 feet under temporary emergency conditions. For ABSS cable - The maximum ADSS sag for a weather case of /2 inch radial ice at 32 deg F, no wind is the weather condition that produces the greatest sag exceeding the NESC Heavy weather condition, and therefore the minimum clearances to the water surface. This design will exceed the minimum clearance requirement of 17.5 feet with a clearance of 23.6 feet. Minimum phase to ADSS clearance The conditions that would produce the minimum clearance between the phase wires and ADSS cable would be at the maximum operating temperature of 285 deg F for the phase wires and 90 deg F for ADSS. Based on NESC Section 235 and Table 235-5(1) b for communication conductors and cables located in the supply space the clearance between the communication cable and 115kV of the same utility is 40 inches (3.33 feet) and its Note 10 which states there is no clearance specified between fiber optic supply cables meeting Rule 230F1b and supply cables and conductors. Note, conservatively, since no clearance is specified, this case and all crossing cases being petitioned meet the minimum clearance diagonally of 40 inches (3.3 feet). Minimum phase to overhead ground wire (static wire) clearance Based on NESC 235E, the weather case that would produce the minimum clearance between the phase wires and the static wires would be a combination of winter weather factors. The phase conductor condition is 30 def F and the static wire condition is /2 radial ice at 30 deg F based on Table 230-1 for Zone 1. Under these conditions the vertical clearance based on NESC Table 235-6(2)a for span wires when parallel to a line is calculated to be 4.8 feet (29 +(ll5kv xl.05 50kV) x 0.4 ). In this case and all the river

crossing cases being petitioned, this minimum NESC clearance of 4.8 feet between the static wire and the phase conductor is met. Minimum clearance between ADSS and wires carried on different supporting structures (i.e. ADSS to distribution power lines) The NESC condition of /2 ice, no wind at 32 deg F provides the minimum NESC clearance between the ADSS cable and wires carried by other structures. Based on Section 233 and Table 233-1, the NESC minimum clearance between AIJSS which meets Rule 230E1 and open supply conductors, 750V to 22kV, is 2 feet. This clearance requirement is met in the case described by this Appendix. For the Span between STR 123-124 6. Line T-198 crosses the Ashuelot River on H frame wood tangent structures with a span of 430 feet. The largest water width is 120 feet at time of survey. A detail of this structure has been provided with this Petition as FIGURE 1. Minimum distances to ground for truck traffic of 15.5 feet for the ADSS and 20.1 feet for 115kV open supply per the NESC have been met as 20.8 and 24.3 feet of clearance is provided respectively for the ADSS and the conductor wires. 7. Surface water elevations for the Ashuelot River were based on information contained in NH GRANIT, which references FEMA information. The normal flood level for this crossing is approximately 459.6 feet. The surface area of the crossing, as required by the NESC (Section 232, Note 19), is approximately 1.6 acres. This is based on the total area of the river for a 1- mile stretch in either direction of the crossing that includes the crossing based on FEMA digital maps and FEMA identified river boundaries. A GIS tool (ESRI ArcView) was used to calculate the surface area polygon. As stated in paragraph 6 of this petition, the minimum required clearances for 115 kv conductor and A]J55 cable over water surface areas less than 20 acres is 22.1 and 17.5 feet, respectively. 8. As stated in NESC Table 232-1 Note 18, the surface area shall be enclosed by its high water mark and clearances shall be based on the normal flood level. In this case, the final river elevation at this location during the normal flood is 459.6 feet. As stated in paragraph 6 of this petition and paragraph 4 of this Appendix, the minimum required clearances for 115 kv conductors and ADSS cable over water surface areas less than 20 acres is 22.1 and 17.5 feet, respectively. The sags and clearances to the water surface are as follows:

Shield wires - Due to the fact that the static wires are located above the phase wires, its clearances to the water surface will always exceed the minimum required NESC distance. Conductors (phase wires) The maximum conductor sag for the NESC Heavy Loading weather case is always less than the 285 deg F maximum operating temperature (phase wires) based on PSNH transmission standards. The 285 deg F condition produces the greatest sag in the phase wires and therefore the minimum clearance to the water surface. This design will exceed the minimum clearance requirement of 22.1 feet with a clearance of 23.2 feet under temporary emergency conditions. For ADSS cable - The maximum ADSS sag for a weather case of 1/2 inch radial ice at 32 deg F, no wind is the weather condition that produces the greatest sag exceeding the NESC Heavy weather condition, and therefore the minimum clearances to the water surface. This design will exceed the minimum clearance requirement of 17.5 feet with a clearance of 19.7 feet. Minimum phase to ADSS clearance The conditions that would produce the minimum clearance between the phase wires and ADSS cable would be at the maximum operating temperature of 285 deg F for the phase wires and 90 deg F for ADSS. Based on NESC Section 235 and Table 235-5(1)b for communication conductors and cables located in the supply space the vertical clearance between the communication cable and 115kV of the same utility at the structure is 40 inches (3.3 feet) and its Note 10 which states there is no clearance specified between fiber optic supply cables meeting Rule 230F1b and supply cables and conductors. Since no vertical clearance is specified, this case meets the minimum clearance diagonally of 40 inches (3.3 feet) at the structure and at mid span because of horizontal separation. Minimum phase to overhead ground wire (static wire) clearance Based on NESC 235E.1, the weather case that would produce the minimum clearance between the phase wires and the static wires would be a combination of winter weather factors. The phase conductor condition is 30 deg F and the static wire condition is /~ radial ice at 30 deg F based on Table 230-1 for Zone 1. Under these conditions the vertical clearance based on NESC Table 235-6(2)a for span wires when parallel to a line is calculated to be 4.8 feet (29 +(ll5kv x1.05 50kV) x 0.4 ). In this case the minimum NESC clearance of 4.8 feet between the static wire and the phase conductor is met through horizontal separation alone.

Minimum clearance between AIJSS and wires carried on different supporting structures (i.e. ADSS to distribution power lines) The NESC condition of 1/2 ice, no wind at 32 deg F provides the minimum NESC clearance between the AIJSS cable and wires carried by other structures. Based on Section 233 and Table 233-1, the NESC minimum clearance between ADSS which meets Rule 230E1 and open supply conductors, 750V to 22kV, is 2 feet. This clearance requirement is met in the case described by this Appendix.

KEENE ROXBURY 148 I 146 145 ~. St ea MARLBOROUGH DUBLIN, 143 ~( T~9CL SWANZE RICHMOND TROY FITZWILLIAM 142 141 140 139 138 137 d 36 d 1135 ~ Bt~ I, (icliew 12 6~ 1134 -t L~nda Th~ 133 132 131 0 130 129 128 WIRE CR~SING 127 126 125 1~4 123 IT $ 121 120 119 118 117 116 115 0 0.1 0.2 0.4 0.6 114 113 112 111 0. 110 I ES :20,000 PublicSenice ~ 1 Of Now~ Hampshire Exhibit II 115 Ky LINE - T-198 SUBSTATIONS MONADNOCK S/S TO EMERALD STREET s/s * STRUCTURES VANDERWEII~ Locus MAP - STRUCTURES 122-124 T-198 CIRCuIT SWANZEY, NH

PLAN VIEW SCALE: 1 =200 SWAMP GRD. WIRE AW. SHOWN 477 KCM ACSR 18/1. SHOWN @ NESC HEAVY (Or, 1/2 ICE, 4LBS WIND) NOTE: CLEARANCE 5.9 BETWEEN GROUND WIRE @ ~ ICE CONDUCTOR @ 3OF NOTE: CLEARANCE 6 BETWEEN GROUND WIRE @ ~ ICE CONDUCTOR @ ~or 477 KCM ACSR 18/1- SHOWN @ 285w ADSS CABLE SHOWN 32r, 1/2 ICE, NO WIND PROFILE SCALE: 1 =200 EXHIBIT 12 VERTICAL 1 2O AD GAO Transmission Business Unit PROPOSED ADSS LINE 1/5 KV. LINE T 198, MILE 10, STR 122 124 ASHUELOT RIVER WA TER CROSSING SWANZEY, NEW HAMPSHIRE ~1~T DRAWING NO. AS NOTED 7/1/08 i~i D 7649 511