ABOUT UNCERTAINTIES IN SIMULATION MODELS FOR BUILDING SYSTEMS CONTROL

Similar documents
PREDICTIVE MODEL-BASED CONTROL OF VENTILATION, LIGHTING, AND SHADING SYSTEMS IN AN OFFICE BUILDING. Vienna University of Technology, Austria

A REPRESENTATIONAL FRAMEWORK FOR BUILDING SYSTEMS CONTROL. Carnegie Mellon University, Pittsburgh PA USA

PREDICTING OVERHEATING RISK IN HOMES

EVALUATION OF THERMAL ENVIRONMENT AROUND THE BLIND ON NON-UNIFOM RADIANT FIELDS A CFD SIMULATION OF HEAT TRANSFER DISTRIBUTION NEAR THE BLINDS

DYNAMIC DAYLIGHT AND SOLAR CONTROL IN TROPICAL CLIMATE

A PRELIMINARY MODEL OF USER BEHAVIOUR REGARDING THE MANUAL CONTROL OF WINDOWS IN OFFICE BUILDINGS

AN INTERNATIONAL SOLAR IRRADIANCE DATA INGEST SYSTEM FOR FORECASTING SOLAR POWER AND AGRICULTURAL CROP YIELDS

Potential daylight resources between tropical and temperate cities a case study of Ho Chi Minh City and Moscow

Thermal Comfort; Operative Temperature in the Sun

SIMULATION-SUPPORTED ROOM ACOUSTICS RETROFIT OF OFFICE SPACES

The Kentucky Mesonet: Entering a New Phase

Chapter 2 Available Solar Radiation

Energy flows and modelling approaches

Forecast.io Driver. Installation and Usage Guide. Revision: 1.0 Date: Tuesday, May 20, 2014 Authors: Alan Chow

A COMPREHENSIVE STOCHASTIC MODEL OF BLIND USAGE: THEORY AND VALIDATION

Simulation of Temperature Stratification in Atriums: Validation of Basic Model Features. Susan Bajracharya

Hourly solar radiation estimation from limited meteorological data to complete missing solar radiation data

Prepared by : USDA Forest Service Northern Research Station Amherst, MA. ibutton Placement Study: Testing Scenarios for Field Implementation

GHI CORRELATIONS WITH DHI AND DNI AND THE EFFECTS OF CLOUDINESS ON ONE-MINUTE DATA

STUDENT MODELLING COMPETITION

EAS 535 Laboratory Exercise Weather Station Setup and Verification

WeatherWatcher ACP. Astronomers Control Panel (V4 or >) Ambient Virtual Weather Station (Pro or Internet editions) ASCOM platform v4.

How to evaluate daylight. Initiated by the VELUX Group

Response function method

Vantage Pro Technical Reference

MICROENCAPSULATED PHASE CHANGE MATERIALS (PCM) FOR BUILDING APPLICATIONS

Application and verification of ECMWF products in Austria

OFFICE DE CONSULTATION PUBLIQUE DE MONTRÉAL

OPTIMIZING BUILDING DESIGNS USING A ROBUSTNESS INDICATOR WITH RESPECT TO USER BEHAVIOR

I N C L U S I V E & S U S T A I N A B L E H O U S I N G I N C A P E T O W N

Daylighting Buildings Nexus November 12, 2009

DEFINING THE PERFORMANCE OF THE DOUBLE SKIN FAÇADE WITH THE USE OF THE SIMULATION MODEL

The document was not produced by the CAISO and therefore does not necessarily reflect its views or opinion.

Improving the accuracy of solar irradiance forecasts based on Numerical Weather Prediction

teachers and students(gong 2005). For example: square, foot path, lawn area, lakeside area, building of the around. The quality of campus semi-open sp

Tailored high-resolution numerical weather forecasts for energy efficient predictive building control

FIRST CORRELATIONS FOR SOLAR RADIATION ON CLOUDY DAYS IN ITALY

Department of Meteorology University of Nairobi. Laboratory Manual. Micrometeorology and Air pollution SMR 407. Prof. Nzioka John Muthama

PROPOSAL OF SEVEN-DAY DESIGN WEATHER DATA FOR HVAC PEAK LOAD CALCULATION

Project 2. Introduction: 10/23/2016. Josh Rodriguez and Becca Behrens

PAUL RUDOLPH Oriental Masonic Gardens

Group Research Projects

Solar Radiation Protections on Façades: A Case Study in a Hot Semi-Humid Climate

FORECAST OF ENSEMBLE POWER PRODUCTION BY GRID-CONNECTED PV SYSTEMS

Computational Modelling of the Impact of Solar Irradiance on Chemical Degradation of Painted Wall Hangings in an Historic Interior

A SIMPLE MODEL FOR THE DYNAMIC COMPUTATION OF BUILDING HEATING AND COOLING DEMAND. Kai Sirén AALTO UNIVERSITY

Overview of Met Office Intercomparison of Vaisala RS92 and RS41 Radiosondes

IDA ICE CIBSE-Validation Test of IDA Indoor Climate and Energy version 4.0 according to CIBSE TM33, issue 3

Sun to Market Solutions

Global, direct and diffuse radiation measurements at ground by the new Environmental Station of the University of Rome Tor Vergata

An Online Platform for Sustainable Water Management for Ontario Sod Producers

Solar radiation data validation

The impact of urban geometry on the radiant environment in outdoor spaces

A Typical Meteorological Year for Energy Simulations in Hamilton, New Zealand

Automatic Control Laboratory, ETH Zürich

Purdue University Meteorological Tool (PUMET)

Natural Ventilation. CFD modelling of a double-skin facade. Huw Birch. Supervisor: Abigail Hathway

INVESTIGATIONS ON SOLAR THERMAL PROCESS HEAT INTEGRATION WITH PARABOLIC TROUGH COLLECTORS

Sensitivity analysis and validation of an EnergyPlus model of a house in Upper Austria

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Comparison between air temperature measured inside a conventional large wood shelter and by means of present day screens

Aalborg Universitet. Comparative Test Case Specification Larsen, Olena Kalyanova; Heiselberg, Per Kvols. Publication date: 2007

Appendix 4 Weather. Weather Providers

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Development of Optical Light Pipes for Office Spaces

Vertical Illuminance Measurement for Clear Skies in Tehran

Solar Energy Basics II - Estimation of Solar Radiation to a Solar Panel

Table 1-2. TMY3 data header (line 2) 1-68 Data field name and units (abbreviation or mnemonic)

Application and verification of ECMWF products in Austria

INFLUENCE OF THE AVERAGING PERIOD IN AIR TEMPERATURE MEASUREMENT

Development Of A REST API For Obtaining Site-Specific Historical And Near-Future Weather Data In EPW Format

Developments towards multi-model based forecast product generation

Patrick H. Oosthuizen and J.T. Paul Queen s University Kingston, ON, Canada

WeatherHawk Weather Station Protocol

INVESTIGATING GLAZING SYSTEM SIMULATED RESULTS WITH REAL MEASUREMENTS

ARCHITECTURE IN THE DAYLIGHT

A NUMERICAL MODEL-BASED METHOD FOR ESTIMATING WIND SPEED REGIME IN OUTDOOR AND SEMI-OUTDOOR SITES IN THE URBAN ENVIRONMENT

FORENSIC WEATHER CONSULTANTS, LLC

Measurements of Solar Radiation

Application and verification of ECMWF products at the Finnish Meteorological Institute

DELIVERABLE 5.3 Report on Predictive control system development and performance tests 1

Solar radiation and thermal performance of solar collectors for Denmark

Indoor Testing of Solar Systems: A Solar Simulator for Multidisciplinary Research on Solar Technologies

TREES Training for Renovated Energy Efficient Social housing

OPTIMISING THE TEMPORAL AVERAGING PERIOD OF POINT SURFACE SOLAR RESOURCE MEASUREMENTS FOR CORRELATION WITH AREAL SATELLITE ESTIMATES

The TexasET Network and Website User s Manual

TOTAL COLUMN OZONE AND SOLAR UV-B ERYTHEMAL IRRADIANCE OVER KISHINEV, MOLDOVA

Development of Innovative Technology to Provide Low-Cost Surface Atmospheric Observations in Data-sparse Regions

Analysis of Energy Savings and Visual Comfort Produced by the Proper Use of Windows

Introduction to Numerical Weather Prediction. Mike Leuthold Atmo 336

Aalborg Universitet. Empirical Test Case Specification Larsen, Olena Kalyanova; Heiselberg, Per Kvols. Publication date: 2006

Data Analysis and Mechanical System Performance. Denver Art Museum August 15-16, 2012

Laboratory Exercise #7 - Introduction to Atmospheric Science: The Seasons

personal weather station

TRENDS IN DIRECT NORMAL SOLAR IRRADIANCE IN OREGON FROM

CARLOS F. M. COIMBRA (PI) HUGO T. C. PEDRO (CO-PI)

Solar Radiation and Solar Programs. Training Consulting Engineering Publications GSES P/L

IMPROVED MODEL FOR FORECASTING GLOBAL SOLAR IRRADIANCE DURING SUNNY AND CLOUDY DAYS. Bogdan-Gabriel Burduhos, Mircea Neagoe *

Interview with Dr. Jaya Singh. 1. How critical is weather monitoring in a solar power plant and what are all the parameters to be monitored?

ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS

Transcription:

ABOUT UNCERTAINTIES IN SIMULATION MODELS FOR BUILDING SYSTEMS CONTROL Kristina Orehounig, Matthias Schuss, Claus Pröglhöf, and Ardeshir Mahdavi Department of Building Physics and Building Ecology Vienna University of Technology Vienna, Austria ABSTRACT This paper presents the process and the results of a calibration effort of a thermal simulation model of an existing office building in Vienna, Austria. The model is an integral component of the building s innovative model-based control logic for the operation of windows and shades. To achieve the desirable level of accuracy, sources of uncertainty in the simulation model are identified and treated. In the present contribution, we focus on two sources of uncertainty namely the prediction capability of a calibrated simulation model, and errors in weather predictions. INTRODUCTION In previous research and the respective publications, we have introduced and described the concept and various implementations of a simulation-based approach to building systems control (Mahdavi 08). In this approach, control decisions are made based on a proactive comparison of simulated implications of alternative control actions. The best-performing control option can thus be identified and executed on a regular basis. In a recent implementation effort, we implemented and started to test such a simulation-assisted control system for effective passive room cooling in an office building, in which three rooms were selected and equipped with motorized windows and automated blinds (Pröglhöf et al., Orehounig et al. ). Thereby the control scheme was as follows: at a specific point in time in a typical summer day, the control unit applies simulation to predict how various window and shade operation regimes would affect the indoor temperature over the course of the following hours. The essential advantage of this method is the possibility to bypass conventional airconditioning systems and harness instead the naturally occurring day-night temperature difference toward free space cooling. To endow the window and shade operation unit with predictive capabilities, we developed simulation models for the office spaces using a numeric simulation application. The initial testing phase of the system's operation highlighted the importance of the accuracy of the simulation model's predictions. To achieve the desirable level of accuracy, sources of uncertainty in the simulation model must be identified and treated. In the present contribution, we focus on two sources of uncertainty in the simulation process: i) Simulation model requires input data regarding window positions towards the estimation of the resulting air change rates. We illustrate the potential for the calibration of the simulation process based on the comparison of measured and predicted air change rates given a set of input assumptions. ii) Simulation model's prediction of the future conditions in the office spaces uses weather data forecast as input assumption. Our experiences so far suggest that the implications of weather forecast errors for the reliability of the control system are significant. Preferably, weather predictions should be based on data obtained from a local weather station at the close proximity of the building. METHODS In a recent implementation effort, we started to test a simulation-assisted control system for effective passive room cooling in an office building. The object is a University building located in Vienna (see Figure 1), in which three adjacent rooms were selected and equipped with motorized windows and automated blinds. These three rooms are south facing (Figure 2) and are referred to as R1, R2 and R3. R1 acts as a reference room and was left untouched. The room is equipped with manual internal, simple venetian blinds. The users can open the windows manually. In R2 and R3 the existing windows were partly motorized. R2 was equipped with automated internal venetian blinds and R3 with automated external venetian blinds (Figure 2). Additionally, offices were equipped with indoor environmental sensors for air temperature, humidity, illuminance, flow velocity, and surface temperatures (Figure 3). External environmental data such as temperature, relative humidity, wind speed, wind direction, global horizontal radiation, and diffuse horizontal radiation were collected. Moreover, window opening and shading positions were

recorded. As to the external environmental conditions, a weather station was installed on the roof of a close-by building. Figure 1 External view of the selected building R1 R2 R3 Figure 2 Floor plan of the three offices Figure 3 Workplaces in R2 with motorized window, internal venetian blinds, and sensors Control approach The potential for the application of a simulationbased natural ventilation control strategy has been addressed, in principle, in our previous publications (Mahdavi & Pröglhöf 04, 05, Mahdavi 08, and Mahdavi et al. 09). The idea was to utilize the day-night difference in outdoor air temperature toward passive space cooling via optimized operation of natural (window) ventilation. Therefore a simulation model was generated and calibrated for the above mentioned building. As to the control scheme approach: At a specific point in time in a typical summer day (d j ), the control unit applies simulation to predict how various window operation regimes would affect the indoor temperature in a building over the course of the following day (dj+1). An "operation regime" denotes in this context which windows, when, how long, and to which extent, are opened. To compare and rank the performance of various control options (alternatives), we applied in this case the Mean Overheating (OHm) of the indoor air in selected spaces (see Equation 1) as the relevant performance indicator. OH m = n i= 1 θi θr n (1) Where θ i denotes indoor air room temperature ( o C) at hour i in day d j+1, θ r the reference indoor air temperature for overheating ( o C), and n the total number of considered hours in day d j+1. This number was considered to be for the office spaces. Note that the term θ i θ r (in Equation 1) is considered only for those hours when θ i > θ r. In our illustrative example, the reference overheating temperature (θ r ) was assumed to be 26 o C. In the control situation, weather forecast information for the following day is used as input information for the simulation runs. In the present emulations, weather predictions are taken at 18:00 for the following 24 hours. These weather predictions were derived from a web-based service (Weather channel 09). Thus, amongst a number of discrete alternative window operation scenarios, one could be selected, which, according to simulation results, would minimize the overheating of the indoor air in the following day. To illustrate this process, Table 1 shows a number of alternative window operation scenarios (schedule and degree of window opening). Simulation process The initial testing phase of the system's operation highlighted the importance of the accuracy of the simulation model's predictions. To achieve the desirable level of accuracy, sources of uncertainty in the simulation process must be identified and treated. In the present contribution, we focus on two sources of uncertainty in the simulation process: 1. Simulation model uncertainties: The simulation model, which is used for the control strategy was generated based on building information (geometry and construction) using a numeric simulation application (EDSL 07, 08). Material properties such as thermal conductivity and specific heat capacity were based on in-situ observations and applicable document archives. Information regarding occupancy, lighting,

equipment, window positions, and shades position was based on monitoring in the office spaces. Air change rates were computed by the simulation application based on input data on window opening positions. To calibrate this computation, measured values of air change (in room R2 and R3) for various window positions on two days in June 09 were used. Simulated and measured air change rates were compared to calibrate the window opening degree. Simulations were run using weather files specifically generated based on data obtained from the local weather station. Simulation results were compared with corresponding measurements (such as room air temperature), resulting in a calibrated simulation model. 2. Weather forecast uncertainties: The weather forecast information used for the simulationassisted passive cooling in buildings, is derived from a web-based meteorological weather service (for the city of Vienna), which provides hourly data regarding air temperature, humidity, wind speed, wind direction, probability of precipitation, and sky condition for the next 48 hours (Weather channel 09). Typical weather files for building performance simulation require air temperature, humidity, wind speed, and wind direction. Moreover, information is needed regarding global horizontal radiation, diffuse horizontal radiation, and cloud cover, which was not provided by the web based service. Instead, this service provides sky condition information in verbal terms such as "clear sky", "partly cloudy", "mostly cloudy", and "sunny". These terms typically refer to the fraction of the sky obscured by clouds (e.g., 0: clear sky, : overcast sky). We used this information to estimate the cloud cover values and further to estimate input data for global and diffuse horizontal radiation. Subsequently, global horizontal irradiance (E G,H ) was approximated as a function of cloud cover (CC) and global clear sky irradiance (E G,C ) according to the relationship which we derived based on empirical data (see Equation 2). Diffuse horizontal radiation was further calculated based on the clearness index, which takes the temperature, humidity, extraterrestrial radiation, and global horizontal radiation into account (Reindl 1990). E 2 G, H = 0.0085 CC EG, C + (2) 0.0174 CC E G, C + 0.8288 E G, C To further explore the extent of weather forecast errors, weather predictions were compared to actual data (for August 09). We used the outcomes of this analysis to further adjust weather predictions (which are generated for the city of Vienna) to the location of our building. RESULTS Control method implementation To test the simulation-based control system's operation, different scenarios were generated (see Table 1) and simulated every evening at 18:00 for the next 24 hours (using the respective weather forecast information). Figure 4 shows, for R3, the predicted indoor air temperature resulting from these alternative control scenarios. Table 2 shows calculated Mean Overheating values for these scenarios. Scenarios with better performance (highlighted in grey in Table 2) were implemented in the actual operation. Figure 5 shows measured indoor air temperatures in all three offices together with the outdoor air temperature for the test period. R3 and R2 were controlled by the simulation-based method. R1 acts as a reference room and remained mostly unoccupied with closed windows. Table 1 Illustrative alternative control scenarios (s1 to s7) for window (W) operation ("f": fully open, "p": 40% open, "c": closed) in selected offices. The operation of the blinds (B) is specified either as "f" (fully open) or "c" (80% closed). s1 s2 s3 s4 s5 s6 s7 hr W B W B W B W B W B W B W B 19 p c p c p c p c c c c c p f p c p c p c p c f f f f f f 21 p f p f p f p f f f f f f f 22 p f p f f f p f f f f f f f 23 p f p f f f p f f f f f f f 00 p f p f f f p f f f f f f f 01 p f f f f f f f f f f f f f 02 p f f f f f f f f f f f f f 03 p f f f f f f f f f f f f f 04 p f f f f f f f f f f f f f 05 p f f f f f f f f f f f f f 06 p f f f f f f f f f f f f f 07 p f f f p f f f f f f f f f 08 p f f f p f f f f f f f f f 09 p f f f p f f f f f f f f f p c f f p c p c f f f f f f 11 p c f f p c p c f f f f f f 12 p c f f p c p c c c f f f c 13 p c c c p c p c c c f c f c 14 p c c c p c p c c c p c p c p c c c p c p c c c p c p c 16 p c p c p c p c c c p c c c 17 p c p c p c p c c c c c c c 18 p c p c p c p c c c c c c c

change rates in buildings. Note that, in the present case, the simulation application's default standard pressure coefficient values were used. We would expect, that even a better reproduction of measured values could be achieved, if pressure coefficients would be computed in a detailed manner using CFD (or empirically obtained via wind tunnel tests). 24.08. 18:00.08. 18:00 26.08. 18:00 27.08. 18:00 28.08. 18:00 s1 s2 s3 s4 s5 s6 s7 Figure 4 Simulation-based predictions of the indoor air temperature in R3 (day d j+1 ) for alternative control scenarios (s1 to s7 as per Table 1) for four days in August 09 Table 2 Comparison of control scenarios (Table 1) based on predicted Mean Overheating (OH m in K) OH m [K] s1 s2 s3 s4 s5 s6 s7 24.8. 0.5 0.4 0.4 0.4 0.3 0.3 0.3.8. 1.2 1.0 1.1 1.0 0.9 0.9 0.9 26.8. 2.1 1.6 1.9 1.8 1.6 1.6 1.5 27.8. 2.9 2.2 2.6 2.3 2.1 2.3 2.2 24.08. 18:00.08. 18:00 26.08. 18:00 27.08. 18:00 28.08. 18:00 Table 3 Measured air change rates in office R2 and R3 on 16 th and 17 th of June 09 Room R2 R3 Window position ACH [h -1 ] Wind speed [m.s -1 ] Wind dir. [ ] open 8.6 6.8 270 partly open 1.6 6.8 270 closed 0.3 3.2 270 open 8.3 2.7 3 partly open 1.1 2.5 45 closed 0.3 1.7 1 Table 4 Simulated versus measured air change rates in office R2 and R3 on 16 th and 17 th of June 09 Room Window position R2 R3 Measured ACH [h -1 ] Simulated ACH [h -1 ] Window opening degree [%] open 8.6 7.6 40 partly open 1.6 1.5 8 closed 0.3 0.3 1.3 open 8.3 8.0 40 partly open 1.1 1.3 8 closed 0.3 0.3 1.3 R1 R2 R3 Ext Figure 5 Measured indoor air temperature in rooms R1 to R3 together with external temperature over the test period Simulation calibration The operation of the system, as documented in the above results, was based on multiple runs with a calibrated simulation engine. As previously noted, the simulation model applied uses window opening degrees (in %) as input information. As part of the simulation calibration process, we compared the results of air change measurements with corresponding simulation results. Measured air change rates for R2 and R3 are shown in Table 3. Table 4 includes, for these, a summary comparison of measured and simulated air change results. We consider these results satisfactory, given the considerable uncertainties involved in simulating air To address the extent of weather forecast errors, weather predictions were compared to actual data (for August 09). Figure 6 shows the Mean relative error of outdoor temperature and irradiance predictions as a function of prediction time horizon (from 1 hour to 18 hours ahead). Predicted temperatures show an error of about -5% fairly independent of the prediction time horizon. Thus, as part of the simulation process calibration, this systematic error was reflected in the simulation input assumptions regarding weather information. Consequently, Figure 7 shows the comparison between the predicted (locally adjusted weather forecasts from the web-based service) and the measured (weather station based) outdoor temperatures for four days in August 09. Predictions were made every day at 18:00 for the following 24 hours.

Mean relative error [%] 40 5 0 5 1h 3h 6h 9h 12h h 18h Temperature predicted hour Irradiance Figure 6 Mean relative error of outdoor temperature and irradiance predictions (August 09) as a function of prediction time horizon (from 1 hour to 18 hours ahead) 24.08. 18:00.08. 18:00 26.08. 18:00 27.08. 18:00 28.08. 18:00 measured predicted Figure 7 Comparison predicted and measured outdoor temperature over a period of 4 days in August 09 Having thus calibrated the simulation model in view of ventilation rates and weather conditions, we could compare measured and predicted indoor air temperatures in the test space (R3). To demonstrate this point, Figure 8 shows, as an example, simulated and measured indoor air temperatures for the actually selected scenarios (grey areas in Table 2) for the four day test period in office R3. 24.08. 18:00.08. 18:00 26.08. 18:00 27.08. 18:00 28.08. 18:00 measured simulated Figure 8 Comparison simulated and measured indoor air temperature R3 resulting from the system's operation DISCUSSION AND CONCLUSION In this paper, we presented the process and the results of a calibration effort related to a thermal simulation model of an existing office building in Vienna, Austria. This model is an integral component of the building's innovative model-based control logic for the operation of windows, shades, and lights. To enhance the prediction capability of the simulation model, it was subjected to a systematic calibration effort. Results of the implementation effort suggest that the predictive simulation-based control approach toward intelligent space cooling is feasible. As Figure 5 suggests, indoor temperatures in R3 (equipped with external shades) display lower values than in R2 (equipped with internal shades), followed by R1 (reference room). Mean Overheating was calcuated for this observation period as 2.9 K in R1, 1.9 K in R2, and 0.9 K in R3 during occupancy hours. The quality of the system operation depends on the reliability of the simulation application's algorithms, relevant input assumptions, as well as input data regarding window positions towards the estimation of the resulting air change rates. The predictive accuracy of the simulation models can be improved via calibration. In the present implementation, we illustrated the potential for the calibration of window position assumptions based on the comparison of measured and predicted air change rates. Likewise, we argued that a good predictive performance of the simulation application requires high-quality and locally adjusted weather forecast data. The resulting calibrated simulation model provided reliable predictions: for the 4-day period depicted in Figure 8, compared pairs of measured and simulated room temperature values showed a mean relative error of -1.2% (simulated values were in average 1.2% lower than the measured values). The corresponding error in terms of RMS amounted to 0.54 K. We are currently exploring potential toward finetuning of system performance through more frequent control state updates. In the implementation illustrated in this paper, simulation-based assessment of alternative control options was conducted once each day (in the afternoon) for the following day. However, such assessments could be performed more frequently (e.g. every hour). This continuous mode of operation with shorter intervals would make it possible to examine, evaluate, and revise control decisions regularly. Moreover, refinements of control scenario generation and selection process are being undertaken using stochastic search routines and genetic algorithms.

ACKNOWLEDGEMENT The research presented in this paper is supported in part by a fund from FFG "Naturally Cool" (Project- Nr: 817575) and by the K-Project "Multifunctional Plug & Play Façade" (Project-Nr: 8075, Project coordinator: Dr. M. Müller, FIBAG). Additional support was provided by TU-GUT, Vienna University of Technology (Project collaborator: G. Hodecek). REFERENCES EDSL 07. A-TAS Theory Manual. EDSL Documentation. EDSL 08. A-TAS Version 8.5. Environmental Design Solutions Limited. www.edsl.net. Mahdavi, A. 08. Predictive simulation-based lighting and shading systems control in buildings. Building Simulation, an International Journal. Springer. Volume 1, Number 1. ISSN 1996-99. pp.. Mahdavi, A., Orehounig, K., and Pröglhöf, C. 09. A simulation-supported control scheme for natural ventilation in buildings. Building Simulation 09, Proceedings of the 11th International Building Performance Simulation Association Conference and Exhibition. Glasgow, Scotland. McElroy L.B., Turley J.S.(Editors) Mahdavi, A., and Pröglhöf, C. 04. Natural ventilation in buildings Toward an integrated control approach. Proceedings of the th congress on air-conditioning, heating, refrigerating. "AMD Sistern". pp. 93 2. Mahdavi, A., and Pröglhöf, C. 05. A model-based method for the integration of natural ventilation in indoor climate systems operation; in: "Building Simulation 05, Proceedings of the 9th International Building Performance Simulation Association Conference and Exhibition, Montreal, Canada". pp. 685-692. Orehounig, K., Mahdavi, A., Pröglhöf, C., and Schuss, M.. Virtual implementation of a simulation-assisted passive cooling strategy in buildings; in: Clima - th REHVA World Congress, Antalya, Turkey. N. Sahin (Editor), 8 pages. Pröglhöf, C., Schuss, M., Orehounig, K., and Mahdavi, A.. Incorporation of a novel passive cooling method in an existing building; in: Clima - th REHVA World Congress, Antalya, Turkey. N. Sahin (Editor), 8 pages. Reindl, D. T., Beckman, W. A., and Duffie, J. A. 1990. Diffuse fraction correlations. Solar Energy, Volume 45, Issue 1, 1990, Pages 1-7. Weather Channel 09. Data download August 09. http://www.weather.com