New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors

Similar documents
Spectrometric Performances of CdTe and CdZnTe Semiconductor Detector Arrays at High X-ray Flux

New trends in CdTe detectors for X and γ-ray applications

Development and characterization of 3D semiconductor X-rays detectors for medical imaging

Fast Neutron and Gamma-Ray Detectors for the CSIRO Air Cargo Scanner

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Chapter 4 Scintillation Detectors

CZT Gamma Spectrometry Applied to the In-situ Characterisation of Radioactive Contaminations

Development of High-Z Semiconductor Detectors and Their Applications to X-ray/gamma-ray Astronomy

WM2013 Conference, February 24 28, 2013, Phoenix, Arizona, USA

Application of Nuclear Physics

EEE4106Z Radiation Interactions & Detection

Polaris 3-D CdZnTe (CZT) Gamma-Ray Imaging Spectrometers

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

General Overview of Radiation Detection and Equipment

Recent improvements in on-site detection and identification of radioactive and nuclear material

TECHNICAL WORKING GROUP ITWG GUIDELINE ON LABORATORY APPLICATIONS OF HIGH-RESOLUTION GAMMA SPECTROMETRY

Activities at the Laboratory of the Nuclear Engineering Department of the Polytechnic University of Valencia

Detector R&D at KIPAC. Hiro Tajima Kavli InStitute of Particle Astrophysics and Cosmology

Detection and measurement of gamma-radiation by gammaspectroscopy

SCANNING OF CARGO CONTAINERS BY GAMMA-RAY AND FAST NEUTRON RADIOGRAPHY

TECHNICAL WORKING GROUP ITWG GUIDELINE ON IN-FIELD APPLICATIONS OF HIGH- RESOLUTION GAMMA SPECTROMETRY FOR ANALYSIS OF SPECIAL NUCLEAR MATERIAL

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Chemical Engineering 412

1 of :32

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

Radiation Detection and Measurement

Detector R&D in KAPAC

Detector R&D at KIPAC

IPNDV Working Group 3: Technical Challenges and Solutions Nuclear Material (3) Technology Data Sheet

Modular Survey Spectrometer and Compton Imager

Radiation Detection and Measurement

Study of the phase contrast for the characterization of the surface of microshell

Stability and Characteristics of Large CZT Coplanar Electrode Detectors

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

Position Sensitive Germanium Detectors for the Advanced Compton Telescope

Fissile material experiments at the Device Assembly Facility

THE spectroscopic performance of large volume CdZnTe

CCD readout of GEM-based neutron detectors

PERFORMANCE IMPROVEMENT OF CZT DETECTORS BY LINE ELECTRODE GEOMETRY

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

COMMISSIONING TESTS OF THE NEW NEUTRON RADIOGRAPHY FACILITY AT THE LVR-15 REACTOR ABSTRACT

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Photon Instrumentation. First Mexican Particle Accelerator School Guanajuato Oct 6, 2011

PoS(FNDA2006)033. Radiography Using Fission Neutrons. Thomas Bücherl. Christoph Lierse von Gostomski

NGN PhD Studentship Proposal

arxiv: v1 [physics.ins-det] 29 Jun 2011

Plasma Accelerator for Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

Neutron Based Techniques for the Detection of Illicit Materials and Explosives

Simulation of charge transport in pixelated CdTe

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

Fast Polycrystalline-CdTe Detector for LHC Luminosity Measurements

Status Report on the detection of illicit materials in cargo containers by using neutron beams.

Recent advances and future perspectives of gamma imagers for scintimammography

ROSAT Roentgen Satellite. Chandra X-ray Observatory

Design and production of Scintillation Detectors

X- & γ-ray Instrumentation

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

Problem Solving. radians. 180 radians Stars & Elementary Astrophysics: Introduction Press F1 for Help 41. f s. picture. equation.

RADIATION DETECTION AND MEASUREMENT

1.4 The Tools of the Trade!

Development of New MicroStrip Gas Chambers for X-ray Applications

How we wanted to revolutionize X-ray radiography, and how we then "accidentally" discovered single-photon CMOS imaging

Detectors for High Resolution Gamma-ray Imaging Based on a Single CsI(Tl) Scintillator Coupled to an Array of Silicon Drift Detectors

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Contrabands detection with a low energy electron linac driven photoneutron source

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

ORIGAMIX, A CDTE-BASED SPECTRO-IMAGER DEVELOPMENT FOR NUCLEAR APPLICATIONS

Radioactivity. Lecture 6 Detectors and Instrumentation

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Semiconductor Detectors

Mass Determination of Rn and Hg isotopes using MASHA

Gamma and X-Ray Detection

Charge collection in PET detectors

Radiation Detection and Measurement

Detection of X-ray spectra and images by Timepix

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

The Best Gamma-Ray Detector

Special SLS Symposium on Detectors

Radionuclide Imaging MII Detection of Nuclear Emission

Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector

Development of a Radioxenon Detection System Using CdZnTe, Array of SiPMs, and a Plastic Scintillator

Pulsed Neutron Interrogation Test Assembly - PUNITA

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

A. I, II, and III B. I C. I and II D. II and III E. I and III

Background Reduction Using Collimators on a Portable HPGe Nuclide Identifier

Semi conductor detectors for soft gamma-ray astrophysics

Simulation of nonorganic scintillation detector response for the problems of active interrogation by tagged neutron technology

Detection of Explosives and Other Illicit Materials by Nanosecond Neutron Analysis

NUCL 3000/5030 Laboratory 2 Fall 2013

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

Multivariate analysis of energy dispersive X ray diffraction data for the detection of illicit drugs in border control

POSITION SENSITIVE DETECTION OF CONCEALED SUBSTANCES EMPLOYING PULSED SLOW NEUTRONS

Spectral Filtering for Improving Quality of Material Discrimination Using Dual Energy X-rays

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Warsaw University of Technology, Faculty of Physics. Laboratory of Nuclear Physics & Technology. Compton effect

Investigation of fast neutron spectroscopy capability of 7 Li and 6. Li enriched CLYC scintillator for nuclear physics experiments

Transcription:

New perspectives in X-ray detection of concealed illicit materials brought by CdTe/CdZnTe spectrometric detectors Jean-Marc Dinten, Jean-Louis Amans, Loïck Verger, Olivier Peyret CEA-LETI, MINATEC, Recherche Technologique 17, avenue des Martyrs 38054 Grenoble Cedex 9 France jean-marc.dinten@cea.fr/jean-louis.amans@cea.fr/loick.verger@cea.fr/olivier.peyret@cea.fr ABSTRACT Most of present X-ray approaches for explosive detection in packages are based on density and atomic number characterization of materials through dual energy transmission imaging. Due to the poor resolution in energy of classical sandwich detectors (two detectors one over the other separated by a filtering material to favour high energy detection in the second detector) used on the dual energy systems, the identification of illicit materials remains tricky. A way to improve and to upgrade these systems has been proposed by using multi-energy X-ray generators. Nevertheless, the use of these systems has been limited in reason of a complicated technological implementation of multi-energy X-ray shots. Another way of improvement of material characterization has been investigated by combining X-ray transmission information with analysis of narrow angle scattering profile in energy. Such systems need detectors with high energy resolution and were based on the use of single pixel Germanium semi-conductors detectors. These systems remain slow and need a cumbersome nitrogen cooling systems, which limits their use. Semi-conductor material, and more specifically CdTe or CdZnTe, enables to build spectrometric detectors operating at room temperature with a high energy resolution. Moreover, these detectors can be pixelated and assembled in order to provide either 1D linear spectrometric detectors or 2D spectrometric imagers with high count rate. These characteristics associated to dedicated spectrometric information processing (multi-energy image processing, spectral information of narrow angle scattering) open the gate to new improved systems for an effective explosive detection and identification, overcoming the drawbacks encountered by the present systems. As CdTe/CdZnTe detectors count the number of photons collected in several energy channels, a multi-energy analysis with a single shot X-ray generator can be implemented. Compared to a classical dual energy approach, such multi-energy approach refines the characterization of observed materials in terms of transmission properties. Moreover, as CdTe/CdZnTe enables to design linear or matrix spectrometric detectors, parallelized detections of narrow angle scattering profiles can be carried out, enabling a fast characterization of observed materials through their narrow angle scattering signature in energy. CdTe/CdZnTe based room temperature spectrometric detectors presenting a high energy resolution are well adapted for the development of fast, new portable explosive detection systems with high performances of explosive detection and identification. 1.0 INTRODUCTION Most of present explosive detection approaches by X-Ray are based on the acquisition of a radiographic image representative at each pixel of the absorbed energy of the X-ray flux inside the observed object. A standard acquisition with such a system provides information on shapes and X-ray attenuation of components present in the parcel. However, as X-ray attenuation is correlated to material thickness as well as to material composition, it is very tricky to identify from a single radiograph the nature of materials RTO-MP-SET-125 18-1

present in the parcel: for example, an important attenuation might be due either to a high thickness/moderate density of material or to moderate thickness/high density. In order to discriminate between organic and inorganic materials, detection systems carry out two radiographic acquisitions at two different energies of the X-ray flux. Based on the same principle of enriching information by adding acquisitions at different energies of X-ray flux, we propose a way to use a large number of images corresponding to different X-ray flux energies in order to improve characterization of detected materials and to provide a more precise classification than organic/inorganic. One way to get acquisitions at different X-ray flux energies is to carry out acquisitions at different working points (voltage, current, filtering) of the X-ray generator. This approach is demanding in term of X-ray generator technology and is requiring time to carry out several acquisitions of a same object. We propose an alternative approach by using a spectrometric X-ray detector; this type of detector counts the detected photons and classifies them in energy channel. The main advantage of such an approach is to provide information on X-ray attenuation at a wide range of energy channels from a single X-ray shot. In a first part we will describe a technology of spectrometric detector based on the use of CdTe or CdZnTe semi-conductor material and present an overview of its main characteristics. In a second part we will show how spectrometric detectors can be used in order to improve detection and identification of illicit material concealed in parcels and point out main advantages of CdTe/CdZnTe detection technologies for this objective. 2.0 CdTe/CdZnTe SPECTROMETRIC DETECTORS Most of the nowadays digital detectors used are based on an indirect conversion of X-ray: X-ray conversion occurs in a scintillator and the light produced is converted to an electrical signal in a Thin Film Transistor (TFT) array or Charged Coupled Device (CCD) [1]. For now more than 10 years, a new technology of detection based on the use of semi-conductor detectors has been studied. It is based on a direct conversion of X-ray photons in an electrical signal in a single material [2]. One of the main advantage of this technology is to provide the possibility to process electrical signal of each detected photon and therefore to count the number of detected photons and to characterize each photon in term of energy. Different semi-conductor materials can be considered, CdTe/CdZnTe is one of the most promised candidate which presents properties adapted for X-ray detection [3]. This material has been more precisely studied and used at CEA-LETI for the development of gamma-ray and X-ray detectors. As shown on Figure 1, the principle of a direct semi-conductor detector is at first the conversion in the semi-conductor material of an incoming X-ray photon in an electron and the generation of electron-hole pairs. An electric field is applied across the detector thickness which enables collection of the electrons and the holes by the electrodes. This collection provides an electrical signal representative of the energy of the X-ray photon. Then an electronic chain acquires, forms, and processes this signal in order to count the photon and to determine its energy. One of the main advantages of CdTe/CdZnTe semi-conductor detectors is that they work at room temperature and do not need any mean of cooling while providing a good energy resolution of the detected spectra. Figure 2 compares the resolution of the spectrum for different technologies of spectrometric detectors. One can observe that the best resolution is obtained with a Germanium detector, but such a detector needs cumbersome nitrogen cooling. An indirect spectrometric detector based on an association of a scintillator (NaI) and a photomultiplier (PM) works at room temperature but leads to a poor spectrum resolution. A second important advantage of CdTe/CdZnTe is the possibility to develop structured matrix of pixels and therefore to carry out dedicated X-ray and gamma-ray imagers. 18-2 RTO-MP-SET-125

Figure 1: Principle of detection and processing in a semi-conductor CdTe/CdZnTe detector Figure 2: Comparison of an acquired spectrum for different types of spectrometric detectors As described on Figure 3, the development of such detectors relies on the association of different complementary skills. A first step is to design the geometry and to choose adapted properties of the material for the application. These choices and design are based on the use of a laboratory simulation tool [4, 5] which models the different phenomena of signal formation in CdTe/CdZnTe material. A second step consists in connecting the material to the electronic and then to develop an acquisition and a processing electronics in order to provide the acquired signal. Then this signal is processed in order to provide the energy of the detected photon and to build up the spectrum [6]. CEA-LETI presents all these competences enabling to develop detectors dedicated to specific applications. CEA-LETI has developed such detectors for a wide range of applications. Figure 4(a) presents a portable probe developed at CEA-LETI for detection and automatic identification of radio-isotopes. Figures 4(b) and 4(c) show examples of spectra obtained with CdZnTe semi-conductor probes. Developments carried out to associate a pixelated monolithic detector of CdTe/CdZnTe semi-conductor to an integrated pre-amplifier electronic and with suitable signal processing have led to new 2D spectrometric imagers. Figure 5(a) shows the new CdZnTe pixelated module, and figure 5(b) its associated readout electronic. Figure 5(c) shows an example of spectrum obtained at a pixel for this new gamma-ray imager. RTO-MP-SET-125 18-3

Figure 3: Spectrometric detectors development at CEA-LETI : from material to imaging (a) portable and compact gamma probe (b) example of spectrum obtained with a low energy probe (c) example of spectrum obtained with a high energy probe Figure 4: Examples of developments of CdTe/CdZnTe probes for radioisotopes detection and identification New radiographic detectors, based on the use of CdTe/CdZnTe semi-conductor material, are now being studied and developed [7,8]. Compared to standard radiographic detectors, they present spectrometric capabilities, i.e at each pixel of detection they provide an energy spectrum. The main difference with gamma-ray imager is the necessity to take into account higher flux rates corresponding to radiographic imaging. In next part we will present advantages brought by these new X-ray spectrometric detectors for detection and identification of illicit material concealed in parcels. 18-4 RTO-MP-SET-125

6.4 x 6.4 x 5 mm 3 4x4 pixels, 1.6 mm pitch 16 Full digital channels 16 single channels ASIC 122 kev 16 digital amplifiers Counts 1.6% FWHM @ 122 kev 136 kev Energy (au) (a) New CdZnTe pixelated detector (b) Associated electronic readout (c) Spectrum obtained at one of the pixels of the imager Figure 5: Main components of a CdZnTe spectrometric imager and example of spectrum 3.0 CdTe/CdZnTe SPECTROMETRIC DETECTORS FOR EXPLOSIVE DETECTION 3.1 X-ray detection of explosives As mentioned previously and illustrated on Figure 6(a), a single radiograph of a parcel or a luggage only provides information on the shape and on the X-ray attenuation properties of the observed objects. This information remains too poor for an efficient detection and identification of illicit or dangerous material in the parcel. Illicit materials can be dissimulated by presenting benign shapes and the only attenuation information is insufficient to precisely decide of the potential risk of the observed materials. In order to refine information, some detection systems use a dual energy acquisition, based on the combination of two radiographs obtained at two different X-ray energies of irradiation. As shown on Figure 6(b) this imaging technique provides in addition to the shape of the objects discrimination between organic and inorganic materials. This information enriches significantly the examination; however it would be very useful to be able to distinguish dangerous organic materials from materials of common use. www.vidisco.com www.vidisco.com (a) a single X-ray image : provides essentially information on the shape of examined object (b) dual-energy radiography : the combination of two acquisition at different energies provide a discrimination between organic and inorganic materials. Figure 6: Radiographic examination by X-ray imaging by using standard X-ray detection chains RTO-MP-SET-125 18-5

3.2 Multi-energy X-ray imaging Studies based on the use of more than two energies of X-ray irradiation [9, 10] have shown that the combination of information obtained from six energies of irradiation significantly increases capacities of discrimination between the nature of materials present in a parcel. One difficulty of such an approach is its technical implementation and its strong requirements in terms of X-ray generator capabilities. In order to get good performances of identification of materials, it is essential to reach a good separation between the different irradiation spectra. This requires switching the tube working point across a wide range of energies and for each irradiation to associate an adequate filtration. The same kind of information can be obtained by irradiating an object with a large X-ray spectrum and to detect with a spectrometric detector: it provides attenuation information in each energy channel of the spectrometric detector, as would be obtained by acquisitions at each energy of the different channels. Combination of information between the different channels enables to significantly improve the characterization between the materials. Therefore the use of a spectrometric detector enables to get multi energy information on the observed object from a single radiographic irradiation. Compared to a multienergy irradiation, it is easier to use and it enriches the provided information. 3.2 X-ray diffraction analysis Studies [11] have shown that the spectrum of the small angle scattering represents a signature of the nature of an observed material. The principle of acquisition of small angles X-ray signature is presented on Figure 7. Figure 8 shows examples of signatures of different illicit and current materials. Acquisitions of such signatures require a high resolution in energy of the detector. They can be obtained by the use of a Germanium spectrometric detector but at the price of cumbersome nitrogen cooling system. Use of CdTe/CdZnTe spectrometric detectors enables to get a signature with an adequate energy resolution while working at room temperature. Moreover, as it is possible to develop linear or 2D CdTe/CdZnTe spectrometric detectors, acquisitions can be parallelized and significantly fastened (see Figure 9). Figure 7: Principle of small angle scattering profiles acquisitions (taken from "A CdZnTe array for the detection of explosives in baggage by energy-dispersive X-ray diffraction signatures at multiple scatter angles" C.H. Malden et al., NIMA, 2000) 18-6 RTO-MP-SET-125

Figure 8: Examples of small angle scattering profiles for different material (taken from "Radiation-based security", R. Speller, Radiation Physics and Chemistry, 2001) Figure 9: Possibility to design linear or 2D geometries of CdTe/CdZnTe detectors enables to parallelize small angle scattering acquisitions. 4.0 CONCLUSION Presently X-ray remains one of the major mean to inspect the content of suspicious parcels. Single radiograph and dual energy X-ray approaches provide information on the shape and on the organic/inorganic nature of the content. The use of spectrometric X-ray detectors provides multi-energy information which enables to refine the characterisation of the nature of the content. Moreover addition of spectrometric information from the small angle scattering refines identification by providing information on the molecular structure of the observed materials. CdTe/CdZnTe semi-conductor detectors provide spectrometric information with a good energy resolution, well adapted to multi-energy imaging and to small angle scattering profiles analysis. Compared to Germanium spectrometric detectors, which provide high energy resolution but need to be cooled, CdTe/CdZnTe spectrometric detectors work at room temperature. Therefore, they can be easily be used in the different systems (portable, check points, luggage control) of detection and identification of illicit materials in parcels. Moreover, they can be pixelated and therefore it is possible to develop linear or 2D detectors enabling a parallelization of the acquisitions which fastens significantly the acquisition process. As these detectors can also be designed for detection and identification of radioisotopes, it is possible, on the same technological basis, to develop portable probes or imaging systems for detection of nuclear material. RTO-MP-SET-125 18-7

REFERENCES [1] J.P. Moy, Recent developments in X-ray imaging detectors, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 442 (1), pp. 26-37, (2000) [2] L. Ramello, Medical imaging with semiconductor detectors, AIP Conference Proceedings, 809, pp. 263-282,(2006) [3] L. Verger et al., New Trends in Gamma-Ray Imaging with CdZnTe/CdTe, Nuclear Instruments and Methods, vol. A571, pp. 33-43, (2007). [4] A. Glière et al., Simulation of CdZnTe gamma-ray spectrometer response, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 442 (1), pp. 250-254, (2000) [5] F. Mathy, et al., A Three-Dimensional Model of CdZnTe Gamma-Ray Detector and Its Experimental Validation, IEEE Transactions on Nuclear Science, 51 (5 I), pp. 2419-2426, (2004). [6] G. Montémont et al., A digital pulse processing system dedicated to CdZnTe detectors, IEEE Transactions on Nuclear Science, 52 (5 III), pp. 2017-2022, (2005). [7] V.B. Cajipe et al., Multi-Energy X-ray Imaging with Linear CZT Pixel Arrays and Integrated Electronics, 14th Intl. Workshop on Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors, Rome, Italy, October 18 22, (2004). [8] Y. Tomita et al., X-ray color scanner with multiple energy differentiate capability, IEEE Nuclear Science Symposium Conference Record, volume 6, pp. 3733-3737, (2004) [9] S. Maitrejean et al, Multi-energy method: A new approach for measuring X-ray Transmission as function of energy with a Bremsstrahlung source. Application for heavy element identification, Proceedings of SPIE - The International Society for Optical Engineering, 3446, pp. 114-133, (1998). [10] S. Maitrejean et al., Non destructive chemical identification using an X-ray transmission function obtained with the multi-energy method, Proceedings of SPIE - The International Society for Optical Engineering, 3446, pp. 134-152, (1998). [11] E. Cook et al., Energy dispersive X-ray diffraction as a means to identify illicit materials: A preliminary optimisation study, Applied Radiation and Isotopes, volume 65, issue 8, pp. 959-967, August 2007. 18-8 RTO-MP-SET-125