Package Insert for FASafe/AciSafe

Similar documents
Human anti-myelin associated glycoprotein antibody (MAG) Ab ELISA Kit

Zearalenone Plate Kit PN 53018B

Hepatitis B virus IgM ELISA Kit

Monkey Kidney injury molecule 1,Kim-1 ELISA Kit

MyBioSource.com. This package insert must be read in its entirety before using this product.

Human anti-deoxyribonuclease B, anti-dnase B ELISA Kit

Bisphenol A ELISA Kit

Detection limit: grain, feed 500 ppb; milk 50 ppb; cream, cheese 5 ppb

Canine brain natriuretic peptide,bnp ELISA Kit

This immunoassay kit allows for the in vitro quantitative determination of Aflatoxin M1 concentrations in milk, milk power.

Human rheumatoid factor (RF) antibody (IgM) ELISA Kit

Human hepatitis B virus surface antigen(hbsag) ELISA Kit

Paraquat ELISA Kit. Catalog Number KA assays Version: 17. Intended for research use only.

Human papillomavirus,hpv ELISA Kit

Aflatoxin M1 (AFM1) ELISA Kit

HBeAg and HBeAg Ab ELISA Kit

Microcystin-LR ELISA Kit

Canine Erythropoietin,EPO ELISA Kit

Microcystin-LR ELISA Kit

NukEx Nucleic Acid Release Reagent

KAMIYA BIOMEDICAL COMPANY. Cat IgE ELISA. For the quantitative determination of IgE in cat biological samples. Cat. No. KT-394. For Research Use Only.

TPH (Total Petroleum Hydrocarbons)

Rat Liver Fatty Acid Binding Protein (L-FABP) ELISA

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

Cystatin C ELISA. For the quantitative determination of cystatin C in human biological samples.

Cat IgA ELISA. Cat. No. KT-755 K-ASSAY KAMIYA BIOMEDICAL COMPANY. For the quantitative determination of IgA in cat biological samples

IgG (Cat) ELISA Kit. Catalog Number KA assay Version: 01. Intend for research use only.

Human placenta lactogen, HPL ELISA kit

Mouse IgG2B ELISA. Cat. No. KT-405 K-ASSAY. For the quantitative determination of IgG2B in mouse biological samples. For Research Use Only.

Please use only the valid version of the package insert provided with the kit. This kit is intended for Research Use Only.

IgA (Guinea Pig) ELISA Kit

Zearalenone ELISA Kit

Procine GHb ELISA Kit

GLUTEN RAPID KIT. Product: GLTN Lateral Flow Devices for Qualitative Analysis of Gluten Proteins. Storage at 4-8 C (35-45 F)

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Dog IgM ELISA. Cat. No. KT-458 K-ASSAY. For the quantitative determination of IgM in dog biological samples. For Research Use Only. 1 Rev.

Casein (Bovine) ELISA Kit

Dog NGAL ELISA. For the quantitative determination of NGAL (Lipocalin-2) in dog biological samples. Cat. No. KT-546. For Research Use Only.

LCN2 (Dog) ELISA Kit. Catalog Number KA assay Version: 01. Intend for research use only.

Human Leptin ELISA. Cat. No. KT-1120 K-ASSAY. For the quantitative determination of leptin in human biological samples. For research use only.

[Unless otherwise stated all tolerances are ±5%] SAMPLES

IgE (Rat) ELISA Kit. Catalog Number KA assays Version: 05. Intended for research use only.

Mouse KIM-1 ELISA. For the quantitative determination of Kidney Injury Molecule in mouse serum, plasma, or urine.

Percentage of Acetic Acid in Vinegar

Mouse IgE ELISA. Cat. No. KT-401 K-ASSAY. For the quantitative determination of IgE in mouse biological samples. For Research Use Only.

IgE (Dog) ELISA Kit. Catalog Number KA assays Version: 05. Intended for research use only.

IgM (Canine) ELISA. For the quantitative determination of IgM in canine serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Human anti-ige receptor antibody ELISA Kit

Pig IgG ELISA. Cat. No. KT-516 K-ASSAY. For the quantitative determination of IgG in pig biological samples. For Research Use Only. 1 Rev.

STANDARD OPERATING PROCEDURES

IgD ELISA. For the quantitative determination of IgD in Human Sera. Please See Appendix A for Reference Serum Information

CTX-II (Human) ELISA Kit

Bacterial Gram Staining

IgG (Canine) ELISA. Please see Appendix A for Reference Serum information. For Research Use Only. Not For Use In Diagnostic Procedures.

Additional Materials Required (NOT PROVIDED):

Mouse Glutathione S Transferase Alpha 1 (GSTa1)

Human 25-hydroxy vitamin D3 (25HVD3) ELISA Kit

IgA ELISA. For the quantitative determination of IgA in human serum and plasma. Please see Appendix A for Reference Serum Information

Acetylcholine (Human) ELISA Kit

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

IgG (Rabbit) ELISA Kit

CA125 (Human) ELISA Kit

ADH Activity Assay Kit

IgG (Chicken) ELISA Kit

Rabbit IgA ELISA Kit

Titration with an Acid and a Base

KIM-1 ELISA. For the quantitative determination of Kidney Injury Molecule in various biological samples.

Rat Ferritin ELISA. For the determination of ferritin in serum and plasma of rats. For Research Use Only. Not For Use In Diagnostic Procedures.

IgD ELISA. For the quantitative determination of IgD in Human serum and plasma. Please See Appendix A for Reference Serum Information

Anti-Gliadin Antibody ELISA

For the quantitative determination of IgE in equine serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Human Aspartate aminotransferase, AST ELISA Kit

Anti-Transglutaminase Antibody ELISA

Monensin ELISA Kit. Catalog Number KA assays Version: 11. Intended for research use only.

Human Anti-Ovary Antibody (IgG)ELISA Kit

Mouse Retinol Binding Protein 4 ELISA

For Research Use Only

Mouse IgE ELISA. For the quantitative determination of IgE in mouse serum or plasma. For Research use Only. Not For Use In Diagnostic Procedures.

Mouse cross linked N-telopeptide of typeⅠcollagen, NTX ELISA Kit

Chlamydia Trachomatis IgG ELISA kit

Androstenedione ELISA Kit

C3 (Mouse) ELISA Kit. Catalog Number KA assays Version: 15. Intended for research use only.

Human Alpha 1-Anti- Chymotrypsin ELISA

TF (Bovine) ELISA Kit

Cat Serum Amyloid A (SAA) ELISA

Mouse Lipocalin-2/NGAL ELISA

Experiment: Titration

Chemical Reactions: The Copper Cycle

QuickZyme Hydroxyproline Assay

CHGA (Human) ELISA Kit

Ascorbic Acid Titration of Vitamin C Tablets

CANINE COMPLEMENT FACTOR 3 (C3) ELISA

Human Mullerian Inhibiting Substance/Anti-Mullerian hormone (MIS/AMH)Elisa Kit

Rat Beta-2 Microglobulin ELISA

Prealbumin (Mouse) ELISA KitI

Instructions for use. Glycine ELISA BA E-2100

Human IL-1 beta ELISA Kit

Polychlorinated Biphenyls (PCB) in Soil

Standard Operating Procedure

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Transcription:

SāfTest Inc. PeroxySafe Package Insert Package Insert for FASafe/AciSafe FASafe/AciSafe Kit Package Insert & Control Package Insert Introduction FASafe standard test kit is designed to measure free fatty acid (FFA) content of oils and fats in fresh and used oils and in raw and finished products. Free fatty acids are a key indicator of hydrolytic degradation associated with off flavor and textural changes. The FFA is quantitated as percent oleic acid using an indicator that responds to the acids in the sample matrices. The practical dynamic range of the determination has been established as 0.3 to 1.8 percent oleic acid in these matrices. This test kit is not intended to accurately measure FFA levels lower than 0.3 percent. However, samples with higher levels can be evaluated and only require a dilution step prior to analysis. The Standard kit under validation overestimates the actual FFA concentrations below 0.3 percent. Consequently, sample matrices containing lower FFA levels must be tested using an alternative method (i.e., FFA High Sensitivity Kit). Intended Use of Method SāfTest, Inc. has developed a proprietary test kit FASafe which is designed to provide rapid analysis of fat content in free fatty acid content of oils, tallows, greases, feed, and protein meals using micro-analytical and membrane separation principles. The official American Oil Chemists Society (AOCS) Ca 5a-40 method, commonly used in food testing laboratories, is based on titration of an ethanolic solution of the fat or oil material with ethanolic potassium hydroxide to a visually determined phenolphthalein endpoint. The conventional method requires large volumes of organic solvents, large sample aliquots, and it involves a lengthy titration process, as well as extraction for some samples which can take up to eighteen hours. The proprietary FASafe assay kit can be used for testing solubilized dry and wet food matrices by releasing lipid from the sample matrix using a stabilized reagent (i.e. stabilized isopropanol) and employing mechanical mixing and warming techniques. The solubilized food matrix is then filtered through a membrane and the filtrate is analyzed for free fatty acids. The significantly shorter sample preparation of 15 to 20 minutes permits data to be obtained in 15 to 25 minutes. The SAI s FASafe standard test kit can accommodate up to 135 test tubes and it contains all reagents, calibrators, and control standards required for testing. The test parameters for this procedure are presented below:

Sample Preparation: Time Requirement: Limit of Quantitation: Interferences: Liquid oils require no heating; semi-solid and solid oils and meals require heating Sample Preparation 5 to 10 minutes Analysis Time approximately 5 to 10 minutes 0.3% Highly colored samples, samples containing acids, bases, or chelating metal ions Principle of Method Samples are solubilized in the proprietary preparation reagent, separated through the membrane separation pack, and then analyzed by an optical reader in the presence of the chemical detectors. The test is based on the sensitivity of a chromagen to ph changes as a result of an increase in free fatty acids, which absorbs at 570nm. The increase in free fatty acids is measured as a decrease in the absorbance at 570nm. Lipid peroxide standards are assigned grams of oleic acid per 100 grams of sample. A reference wavelength at 690 nm is used. Controls and Their Use One control is supplied which can be analyzed as described in the control package insert and should fall within concentration ranges provided. General Instructions Test Kit Information a. Kit Name: Percent Fat Test Kit b. Catalog Number: 07PF1010 c. Ordering Information: MP Biomedicals, LLC, www.mpbio.com/saftest, 1.800.848.1163, saftest@mpbio.com d. Test Kit Reagents: Preparation Reagent and Reagent A Isopropanol based reagent with the addition of stabilizers. Reagent A Mixture of three enzymes to breakdown fat to glycerides and then glycerol for colorimetric quantitation. Reagent A is tested for presence of low degradants and low levels of antioxidants are added for stabilization.

Additional Supplies and Reagents Membranes High Non-Specific Adsorption membranes are used for prefiltration and consist of polypropylene or polyethersulfame or polythtrathoro ethylene structures. Apparatus Contents of Bench Top SafTest Platform include: a. SafTest Analyzer b. SafTest Filtration Unit c. Vortex d. Heating Block with tube Inserts e. Test Tube Racks (2) f. Positive Displacement Pipettes (2) g. Bottle Top Dispensers h. Multi Display Timer Contents of Essential Disposable Labware: a. 15mL Conical Vials b. 10mm glass test tubes and caps c. Positive Displacement Pipette Tips d. Kim Wipes e. Glassbeads Standard Reference Materials Standard Solutions Calibrators One to five fixed concentrations of lipid peroxides prepared in stabilized isopropanol. Controls Mixture of triglycerides prepared in stabilized isopropanol. Safety Precautions and Material Safety Data Sheets (MSDS) All testing materials should be handled in accordance with good laboratory practices (GLP). Pipetting by mouth is highly discouraged. Eye protection that satisfies ANSI Z87.1, laboratory coat, and appropriate chemical resistant gloves must be worn while handling standards, reagents, and solvents. The Percent Fat reagent will stain clothing and equipment. Protective equipment that becomes contaminated must be removed and replaced as necessary. When used as directed, the Percent Fat reagents, controls, and calibrators should present no health hazard to the user. As a normal laboratory precaution, avoid contact with eyes and skin. The reagent is water based and requires no special disposal. The test does not have to be performed in a hood.

General Guidelines To minimize contamination during the testing procedures and to maximize the quality of results, please perform the following: 1. Allow all calibrators, reagents, and dispensers to stand at room temperature (18 to 25 C) for 15 to 20 minutes prior to testing. 2. When transferring samples to the membrane units, use a new, disposable transfer pipette for each sample. 3. When using the positive displacement pipette: a. Use a new tip for each sample, control, reagent blank, and calibrators. b. Make sure the pipette tip is securely fastened to the pipette. c. Eliminate all air bubbles from the pipette tip. d. Gently wipe outside of the pipette tip before dispensing the sample to remove excess sample. e. After dispensing the sample, make sure to touch the pipette tip to the inside of the assay tube to expel residual sample at the end of the tip. 4. When using the dispensers: a. Read the dispenser instructions carefully before using. b. Make sure the correct dispenser is placed on the appropriate reagent bottle. c. Dispense five aliquots into a waste container to eliminate any air bubbles prior to each assay. d. Slowly dispense reagents to prevent splashing. e. Do not allow the tip of the dispenser to touch the sides of the tubes. f. Use a new tip for each sample, control, reagent blank, and calibrators. 5. When using the SafTest Analyzer: a. Refer to the SafTest Analyzer instructions detailed instructions and an explanation on error codes. b. Allow the instrument to warm-up for at least 5 to 10 minutes. c. Wipe tubes before analysis. d. Make sure that calibration curve falls within specifications (See Section 13.3.5). 6. Store all reagents, controls, and calibrators in the refrigerator at approximately 2 C to 6 C when not in use. 7. Discard reagents when all reagents in the kit have been exhausted. 8. Only fresh calibrators and Preparation Reagent must be used with new kits. 9. Properly discard any filtered samples, assay tubes, pipette tips, membrane holders, and membrane units. 10. SafTest kits must be refrigerated at 2 to 6 C in an upright position. DO NOT FREEZE KITS. 11. To maximize lamp life, turn off the SafTest Analyzer when not in use.

Sample Preparation 1. Allow the samples and reagents to reach at room temperature before testing. 2. Allow calibrators, Preparation Reagent, Controls, and PeroxySafe Reagent stand at room temperature (18-25 C) for 15-20 minutes. 3. Prepare the samples by following the procedures for the PeroxySafe assay. 4. For samples less than 20% expected % fat, prepare a 1:4 initial dilution as described on the sample preparation card. For samples with expected % fat of 20 to 40%, begin with an initial 1:8 dilution by weighing out 1.0 g and adding 7.0 ml of Prep Reagent. An even higher initial dilution may be required for highly saturated fats in products or higher fat products. Note: Keep solubilized samples warm when filtering and diluting to ensure the more saturated fats remain in solution. 5. For optimal results, the Control must fall within the acceptance range and the slope should be about 2.0 to 2.4. This provides the best range for quantitating percent fat in samples. Do not vortex tubes but invert 4x to mix. Please refer to the Control Insert for acceptance windows. 6. Samples should read above the first (lowest) calibrator and below the fourth calibrator to obtain accurate results 7. Turn heat block on low to 40 C (Dial number 4, ±2 C). Check temperature. 8. Turn on the SafTest Analyzer and allow it to warm up. 9. Start the test using the PeroxySafe protocol. Set the timer and note the time the assay will be analyzed in the SafTest Analyzer. 10. Analyze the assay tubes in the SafTest Analyzer according to procedure given in Quick Start Cards. 11. Refer to Quick Start Cards for a detailed procedure of the analytical process. 12. For optimum results, a sample preparation and dilution scheme is provided in Table 2. Table 2. Sample Preparation and Dilution for SafTest % Fat Test Initial Preparation Next Dilution Final Dilution Expected % Fat Range 1:4 None 1:4 0.0-1.0 1:4 1:2 1:8 1.0-2.0 1:4 1:4 1:16 2.0-4.0 1:4 1:8 1:32 4.0-6.0 1:4 1:12 1:48 6.0-10.0 1:4 1:32 1:128 10.0-20.0 1:8 1:25 1:200 20.0-30.0

1:8 1:50 1:400 30.0-60.0 1:8 1:60 1:480 60.0-100.0 13. To obtain good method precision, CV should be less than or equal to 10%. If CVs are higher, check sample or dilutions for homogeneity. Also, check to make sure that the results are in the optimal range of the calibration curve Quality Control Calibration is required and calibrators are provided for this purpose. Calibration should always be performed with each new kit. For several tests within the same test kit, a STAT curve can be used recalling the last calibration curve. The slope must be linear with a correlation coefficient (r 2 ) at or above 0.990 or the instrument will stop and not read the sample responses. The control should be analyzed in each test run and should fall within the range stated on the control package insert. Analytical Procedure The SafTest, Inc. PeroxySafe Standard Test Kit measures PV in samples using an electron transfer that responds to peroxides in the range of 0.01 to 0.5 expressed as meq of peroxide per kg of oil or fat. Samples with higher peroxide concentrations require additional dilutions before they can be analyzed by this method. Dispenser and Reagent Preparation Allow reagents and dispensers to reach room temperature (i.e., 18 to 25 C) before beginning assay. Mix the contents of the reagent bottles by swirling prior to attaching dispensers. Attach the dispenser labeled PeroxySafe A onto the reagent bottle labeled PeroxySafe Reagent A. Dispenser volume is fixed; therefore, no adjustment is necessary. Attach the dispenser labeled PeroxySafe B onto the reagent bottle labeled PeroxySafe Reagent B. Dispenser volume is fixed; therefore, no adjustment is necessary. Attach the dispenser labeled PeroxySafe C on the reagent bottle labeled PeroxySafe Reagent C. Dispenser volume is fixed; therefore, no adjustment is necessary. Attach the dispenser labeled Preparation Reagent onto the reagent bottle labeled Preparation Reagent. Adjust volume according to instructions provided in Quick Start Card. Dispense approximately 4 to 5 aliquots of each reagent into a waste container to eliminate any air bubbles in the dispensers prior to use. To prime dispensers, please read the instructions in the dispenser package.

Data Interpretation and Test Result Reporting The SafTest Analyzer will use the calibrators to calculate the triglyceride concentration in grams of triglyceride per 100 grams of sample. If the sample value is greater than the value of the highest calibrator, the instrument will flag the result as HI. The sample must be diluted at a higher dilution and retested. Values that are flagged HI are inaccurate and should not be reported. Check the instrument printout for flags or error messages before reporting results. For failed curve fit (r 2 < 0.990 or r < 0.995), repeat the assay. The range for the control is found on the package insert provided with the Percent Fat Control. The assay value for the control should approximate this range. Adjust instrument results by taking into account the dilution factor are tested by pipetting the samples initially as follows: Example Calculations: Dilution Factor Weighed Sample (200X) SafTest Result Dilution x Result Corrected Final Result Final Result 0.224 0.224 x200 44.8 44.8