The phenomenon of Ground Effect in contradiction to the Polarity Effect in rod plate air gaps.

Similar documents
The influence of the Effect of Grounding and Corona Current to the Field Strength the Corona Onset and the Breakdown Voltage of Small Air Gaps

EFFECT OF DIELECTRIC BARRIERS TO THE ELECTRIC FIELD OF ROD-PLANE AIR GAP

Key-Words: - Electrical Engineering education, simulation, power electronics, high voltages. with the classic methods of theory and experimental work.

Finite Element Analysis Method for Detection of the Corona Discharge Inception Voltage in a Wire-Cylinder Arrangement

CHAPTER 2 ESTIMATION OF BREAKDOWN VOLTAGES IN SMALL INSULATION GAPS AN EMPIRICAL APPROACH

Analysis of a Cylinder-Wire-Cylinder Electrode Configuration during Corona Discharge

THE APPROACH TO THE ANALYSIS OF ELECTRICAL FIELD DISTRIBUTION IN THE SETUP OF PAPER INSULATED ELECTRODES IN OIL

Simulation of Prebreakdown Phenomena in Air Gaps of Rod Plane Configuration of Electrodes

Bursting Drops in Solids Caused by High Voltages

CHAPTER 5 ANALYSIS OF ELECTRIC FIELD AND VOLTAGE DISTRIBUTION

Chapter 25. Capacitance

Adaptive numerical simulation of Streamer. Shailendra Singh

HIGH VOLTAGE TECHNIQUES Basic Electrode Systems (3)

HUMIDITY INFLUENCES ON THE BREAKDOWN OF ROD-PLANE GAPS UNDER POSITIVE IMPULSES IN ATMOSPHERIC AIR

Corona Losses Calculation in HVAC Transmission Lines Using FEM and Comparison with HVDC Corona Losses

Flashover Performance of Station Post Insulators under Icing Conditions based on Electric Field Distribution

A New Model of Investigating the Electric Field in Dielectric Liquid for Streamer Initiation

Investigation of fluid flow around a cylinder with EHD actuation on inclined plates behind the cylinder

Transient analysis of the behaviour of grounding systems consisted by driven rods

Exponential Expression of Relating Different Positive Point Electrode for Small Air Gap Distance

Capacitance and Dielectrics

Physics Jonathan Dowling. Final Exam Review

Simulation of the Electric Field on Composite Insulators Using the Finite Elements Method

W05D1 Conductors and Insulators Capacitance & Capacitors Energy Stored in Capacitors

HIGH VOLTAGE ENGINEERING. Electric discharges in electric power engineering

EXPERIMENTAL DEVELOPMENTS ON SOIL IONIZATION: NEW FINDINGS

Capacity calculation of the electrotechnical scheme of discharge gap replacement of the ozonizer in the СOMSOL environment

Electric Potential Energy & Voltage. Tesla Envy =jlzeqz4efqa&feature=related

HIGH VOLTAGE TECHNIQUES Basic Electrode Systems

OR Explain thermal breakdown in solid dielectrics. How this mechanism is

Forces and movement of small water droplets in oil due to applied electric field

Numerical Analyze of Corona Discharge on HVDC Transmission Lines

CZ České Budějovice, Czech Republic b Technical University of Liberec, Department of Materials Science, Hálkova 6, D Dresden, Germany

ELECTRIC FIELD AND VOLTAGE DISTRIBUTION ALONG INSULATORS UNDER POLLUTION CONDITIONS. V T Kontargyri N C Ilia I F Gonos I A Stathopulos

Optimization of Corona Onset and Breakdown Voltage of Small Air Gaps Stressed by DC and Impulse Voltages

EFFICIENCY OF DUAL WIRE-CYLINDER ELECTRODES USED IN ELECTROSTATIC SEPARATORS

EFFECT OF EARTH DISCONTINUED TO THE ELECTRICAL FIELD DISTRIBUTION IN ROD-PLANE AIR GAPS UNDER LIGHTNING IMPULSE. A. Khechekhouche and D.

5) Two large metal plates are held a distance h apart, one at a potential zero, the other

Inception Voltage of Corona Discharge from Suspended, Grounded and Stressed Particles in Uniform-Field Gas-Insulated-Gaps at Varying Pressures

Estimation of the Electric Field and Potential Distribution on Three Dimension Model of Polymeric Insulator Using Finite Element Method

Measurement and simulation of the voltage distribution and the electric field on a glass insulator string

IMPULSE BREAKDOWN OF SHORT ROD-PLANE GAPS WITH A ROD COVERED WITH DIFFERENT DIELECTRIC MATERIALS

EXPERIMENTAL AND THEORETICAL STUDY OF BREAKDOWN VOLTAGE INITIATED BY PARTICLE CONTAMINATION IN GIS

Transduction Based on Changes in the Energy Stored in an Electrical Field

Physics (

Quiz Fun! This box contains. 1. a net positive charge. 2. no net charge. 3. a net negative charge. 4. a positive charge. 5. a negative charge.

Solution for High Voltage Engineering

Hybrid Resistive-Capacitive and Ion Drift Model for Solid Gas Dielectrics

UNIT-I INTRODUCTION. 1. State the principle of electromechanical energy conversion.

Chapter 17. Potential and Capacitance

with embedded electrode

Capacitance and Dielectrics. Chapter 26 HW: P: 10,18,21,29,33,48, 51,53,54,68

COMPARATIVE EVALUATION OF BREAKDOWN STRENGTH OF NATURAL ESTERS AND MINERAL OIL

Electric Field Stress Calculation on High Voltage Insulator

Numerical Calculation and Analysis on the Surface Electric Field Characteristics of Hot-Line Robot

Electric Field Stress Calculation for different spacer types in Bus Duct

TUTORIAL 4. Proof. Computing the potential at the center and pole respectively,

Copyright 2014 IEEE. Paper presented at 2014 IEEE conference on electrical insulation and dielectric phenomena, Des Moines, USA, October, 2014.

Gauss s Law. q 4. The Gaussian surfaces do not have to be spheres. Constant flux through any closed surface.

Capacitance, Resistance, DC Circuits

Can current flow in electric shock?

The objective of a grounding system are: 1. To provide safety to personnel during normal and fault conditions by limiting step and touch potential.

Chapter 24: Capacitance and Dielectrics

Lesson 3. Electric Potential. Capacitors Current Electricity

Chapter 25. Electric Potential

Electrostatics so far

Chapter 25. Electric Potential

Measurement of wettability for polymer materials using non-contact surface resistivity

Modelling Of Mathematical Equation for Determining Breakdown Voltage

Code No: RR Set No. 1

Consider a point P on the line joining the two charges, as shown in the given figure.

Gauss s Law. q 4. The Gaussian surfaces do not have to be spheres. Constant flux through any closed surface.

Lecture 14. PHYC 161 Fall 2016

Electric Potential. Chapter 23. PowerPoint Lectures for University Physics, Twelfth Edition Hugh D. Young and Roger A. Freedman

FACTORS AFFECTING SOIL CHARACTERISTICS UNDER FAST TRANSIENTS

STUDIES ON LIGHTNING CHARACTERISTICS

Effect of Applied Electric Field and Pressure on the Electron Avalanche Growth

ANALOGY BETWEEN ELECTROSTATIC FIELD AND HEAT TRANSFER SIMPLE MODELS

Chapter 18. Circuit Elements, Independent Voltage Sources, and Capacitors

Electric Filed Simulation and Structure Optimization for 40.5kV GIS Based on Finite Element Method

Physics 196 Final Test Point

Measurement of electric potential fields

Chapter 16 Electrical Energy Capacitance. HW: 1, 2, 3, 5, 7, 12, 13, 17, 21, 25, 27 33, 35, 37a, 43, 45, 49, 51

Capacitors And Dielectrics

Physics 112 Homework 2 (solutions) (2004 Fall) Solutions to Homework Questions 2

Simulation of Partial Discharge in Solid Dielectric Material

Finite Element Analysis of Disc Insulator Type and Corona Ring Effect on Electric Field Distribution over 230-kV Insulator Strings

PH 222-2A Spring 2015

AP Physics C. Gauss s Law. Free Response Problems

Lecture 3. Electric Field Flux, Gauss Law. Last Lecture: Electric Field Lines

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER

Physics Notes Chapter 17 Electric Forces and Fields

CIRCUIT ELEMENT: CAPACITOR

Space Charges in Insulators

What will the electric field be like inside the cavity?

SIMULATION OF CORONA DISCHARGE IN CONFIGURATIONS WITH A SHARP ELECTRODE

Thus the variation of the ionisation probability in air with increase of electron energy is as shown in figure below,

Numerical Simulation of Corona Discharge in Compressed Gases with the Effect of EHD Flow

Modeling of Degradation Mechanism at the Oil-Pressboard Interface due to Surface Discharge

EE 427 High Voltage Breakdown & Testing Model Answers. Level 4 Semester 2 Examination - February 2009 Answer 1. anode (+) 2 marks. 3 marks.

Transcription:

The phenomenon of Ground Effect in contradiction to the Polarity Effect in rod plate air gaps. ATHANASIOS MAGLARAS, LEANDROS MAGLARAS Electrical Engineering Department Technological Educational Institute of Larissa Electrical and Computer Engineering School National Technical University of Athens T.E.I of Larissa, 4111 Larissa GREECE. Abstract: The values of the breakdown voltage of an air gap depend on the maximum value of the field strength in the gap, as well as the corona leakage current through the gap. In the present paper we investigate the Ground Effect of small rod plate air gaps, a phenomenon, which is observed due to the grounding of one of the electrodes. Values of the field strength in the gap are recorded and analyzed for the two different arrangements, with the rod or the plate grounded. The distribution of the field along the axis of the gap is strongly affected by the geometry of the gap, and especially by the electrode chosen to be grounded. The Ground Effect affects the corona onset and the breakdown voltage of the rod-plate air gaps analogically. The Ground Effect is intense in small rod-plate air gaps, slightly affected by the Polarity Effect, while the influence of the corona leakage current appears in longer air gaps, where the Ground Effect is decreased, then is vanished and after it is reversed, as the gap length increases.. Key Words: Ground Effect, Polarity Effect, Corona, Simulation, FEM, Air Gaps, Field Strength. 1 Introduction One of the most determinant factors of the dielectric behavior (strength) of the insulating arrangements and especially of the air gaps is the field strength distribution inside the volume of the arrangement, and especially the maximum value of the field strength in the gap, which appears on the rod. Other factors are the polarity and the form of the applied voltage as well as the corona effects, which take place when the field strength exceeds some specific value, [1], [2], [3], [4], [5]. In every insulated arrangement and especially in air gap arrangements, where there is no symmetrical charging, because one of the electrodes is grounded and the other is electrically charged, differences of the electric field s distribution and of the maximum value of the field strength are observed in comparison to the arrangement where both electrodes are electrically charged with opposite charges. The differences occur due to the asymmetry that is caused by the grounding of one of the electrodes. The two basic factors that affect the differences in the field distribution are the geometry of the arrangement as well as the size and shape of the boundary surface in the simulation analysis, [6], [7], [8], [9], [1], [11]. The above differences in the field distribution influence the corona onset and the breakdown voltage of the arrangement accordingly, [8], [9], [1], [11]. In symmetrical arrangements such as rod-rod air gaps the influence caused due to the grounding of one of the electrodes is rather small, resulting this way to small differences of the breakdown voltage between the two cases where the stressed voltage is of positive or negative polarity, [12], [13]. This occurs because of the Polarity Effect which would not exist if the symmetrical arrangement was symmetrically charged, that is positive charge for one of the electrodes and negative for the other. In non-symmetrical arrangements, such as rod-plate air gaps, the grounding s influence in the distribution of the field is significant, depending on the rod s and plate s size. This is easily revealed with the analysis of the field with the Finite Element Method. Respectively important can also be considered the influence of one of the electrode s grounding to the corona onset and the breakdown voltage of the gap, [6], [7], [8], [9], [1], [11]. This recently studied phenomenon is called the Ground Effect and is clearly different from the 1

Polarity Effect although slightly influenced by it, [8], [9], [1], [11]. This paper investigates the Modelling and Analysis of the electric field distribution in rod-plate air gaps under different geometries and arrangements of the gaps, using the Finite Element Method. The Ground Effect is investigated as it concerns the field s distribution as well as the corona onset and the breakdown voltage. The influence of the corona leakage current is also presented. Special software has been used in the present paper for the simulation analysis. It is based on the Finite Element Method in order to solve two-dimensional problems with axisymetric models. The program is based on Gauss s and Poisson s equations. E = V (1) D = ρ (2) ρ or 2 V = (3) ε where E is the field strength, ρ is the space charge density in C/m 3, ε is the dielectric constant of the medium, V is the voltage, and D=εE is the dielectric displacement. The electric charge density, and the total electric charge on a particular surface S, or in the volume included in surface S, are calculated by equations. q = Dn, and Q = Dn ds (4) s The boundary conditions and especially the mesh density used for the analysis are of great importance for accurate results. The field factor (or efficiency factor) n is a net number, which defines the inhomogeneity of the field in the gap and is expressed by equation: n = Emax (6) Eav For a rod-plate air gap the field factor is given by equation [1], [2]. 2G n = If G>>r (7) 4G r ln r, where V is the applied voltage, G is the gap length, Emax is the maximum value of the field strength (on the rod), and r is the radius of the rod s tip. The plate s diameter is big enough. (a) Rod - plate air gap, with symmetrical charging of the electrodes. (b) Rod - plate air gap, with grounded plate. 2 The investigated arrangements. The arrangements, which have been drawn, analyzed, and experimentally studied, are typical rod-plate air gap arrangements of different geometries. The rod electrode is a cylinder long enough, with a small diameter (2-14 mm) and a hemisphere tip. The plate electrode is a disk plate of - mm in diameter. One electrode of each arrangement is stressed by high DC voltage of negative or positive polarity or AC voltage while the other is grounded. All the analyzed models are axisymetric, with a spherical shield big enough in diameter, (figs 1, 2 and 3). Also the node s spacing is small enough. The average value of the field strength, along the axis of an air gap is defined by equation: V Ε av = (5) G (c). Rod - plate air gap, with grounded rod. Fig. 1. The experimental arrangements Shield Rod Mesh Fig 2. The simulated model Plate 2

The Polarity Effect affects the Corona Onset field strength and hence the Ground Effect slightly according to equations, [1], [2]: E + = A + δ + Β + *(δ/r)^.5 E - = A - δ + Β - *(δ/r)^.5 where δ=2.94*ρ/273+θ, Α+=31 to 39.8 KV/cm, Α-=29.4 to 4.3 KV/cm, Β + =11.8 to 8.4 KV/cm, and Β - = 9.9 to 7.3 KV/cm., r is the radius of the rod, P is the pressure and θ is the centigrade temperature of the air. Rod grounded Plate grounded 3 The influence of the Ground Effect to the field distribution. Rod-plate arrangements, with different grounded electrode, different dimensions of the plate and the rod, and different length of the gap have been modeled and analyzed. From the comparison between the three different cases of arrangement with the rod or the plate grounded, either with symmetrical charging of the electrodes, it is resulted that the Ground Effect causes big differences in the field distribution between the three different arrangements. The field distribution, the maximum value of the field strength in a rod plate air gap and the field factor of the gap are demonstrated in figs 4, 5, 6, and 7. It is obvious that the Ground Effect is intense in rod-plate air gaps. In both arrangements, the maximum value of the field strength in the gap (field strength on the rod) decreases with the gap length. It is higher in the arrangement with the plate grounded and tends to get a steady value for each value of the rod s diameter when the gap is longer than 8% of the plate s diameter. Field strength on the rod V/m Rod-plate air gap. Rod 1 mm, plate mm. Applied voltage 1 V. 1 2 3 4 5 6 7 8 Er-r-gr Er-pl-gr Er-symm. Fig 3. Rod - plate air gap. The maximum values of the field strength on the rod, Er, for the three different arrangements are shown in comparison. Symmetrical Charging Field strength on the rod Er, V/m Field factor, Er/Eav 8 6 4 2 Rod plate air gap, with the rod grounded. 5 1 15 2 Gap length G, cm Fig. 4. Field strength distribution in rod-plate air gap models from simulation analysis. (a) Values of field strength on the rod. Rod plate air gap, with the rod grounded 5 1 15 2 Gap length G, cm dr=12 dr=1 dr=8 dr=6 dr=4 dr=12mm dr=1mm dr=8mm dr=6mm dr=4mm (b) Field factor along the axis of the gap Figs 5. Rod-plate air gap, with the rod grounded. The rod s diameter is dr, and the plate s diameter is mm. It is also resulted that the field factor (n=er/eav) increases with the gap length. It takes lower values in the arrangement with the rod grounded and tends to get a steady value for each value of the rod s diameter when the gap length is longer than 8% of the plate s diameter, (fig 6b). In the arrangement with the plate grounded it increases continuously and is in complete agreement with equation 7, (fig 6a). 3

Er/Eav at breakdown 15 1 5 Rod - plate air gap with the plate grounded. 2 3 4 5 6 Gap length G, cm (a) The field factor along the axis dr=12 dr=1 dr=8 dr=6 dr=4 From figs 8 it is resulted that the differences in the value of the field strength on the rod (maximum value in the gap), between the two different arrangements with the plate or the rod grounded, or with symmetrical charging of the electrode, decrease as the plate s diameter increase, while it is not affected by the shield s diameter. When the plate s diameter becomes very large the Ground Effect decreases, because of the mirror effect. In this case the rod-plate arrangement functions like a rod-rod arrangement of double length, stressed by double voltage. Er (V/M) Rod - plate air gap with the plate grounded. 3 5 1 15 2 dr=12 mm dr=1 mm dr=8 mm dr=6 mm dr=4 mm G (cm) (b) The field strength on the rod. Figs 6. Rod-plate air gap, with the plate grounded. The rod s diameter is dr and the plate s diameter is mm. Field strength on the rod V/m Field strength on the rod V/m Rod-plate air gap 5 cm. Rod's diameter 1 mm, voltage 1 V. 14 12 8 6 4 2 4 16 22 28 34 4 46 Plate's diameter mm Er-rod grounded Er-plate-grounded Er-Symmetr-ch (a) In function with the plate s diameter. rod-plate air gap 5 cm. Rod 1 mm, plate mm 4 8 1 16 24 Shield diameter mm 28 52 58 64 Er-r-gr Er-pl-gr Er-symm-ch 3 (b) In function with the shield s diameter. Figs 7. The field strength on the rod in a rod plate air gap for the two different arrangements with the rod or the plate grounded. Voltage is 1 V. 4 The influence of the Polarity and the Ground Effect to the corona onset voltage in rod plate air gaps. The Polarity and the Ground Effect influence the corona onset voltage of small rod-plate air gaps as it is resulted from figs 9, 1, 11 and 12. 4.1 The influence of the Polarity Effect. It is well known that the polarity of the rod s voltage in relation to the plate, which is grounded, influences the corona onset field strength and thus the corona onset voltage [1], [2], [14], [15], [16], [17], [18]. 4. 1.1. The arrangement with the plate grounded. In the arrangement with the plate grounded the Polarity Effect influences the corona onset voltage slightly in favour of the positive polarity of the applied voltage, as it is expected and shown in fig. 8. Corona Onset Voltage KV Rod-plate air gap. Rod 4 mm, plate 3 mm. 28 26 24 22 2 18 16 Vc-pl-gr(+) 14 Vc-pl-gr(-) 12 1 1 2 3 4 5 6 7 8 9 1. Fig. 8. The Polarity Effect in the rod-plate arrangement with the plate grounded. 4.1.2. The arrangement with the rod grounded. In the arrangement with the rod grounded the Polarity Effect does not seem to influence the corona onset voltage in favour of the negative polarity of the applied voltage as it is expected, (fig. 9). 4

Corona Onset Voltage KV Rod-plate air gap. Rod 4 mm, plate mm. 7 6 4 3 2 1 Vc-r-gr (+) Vc-r-gr (-) 1 2 3 4 5 6 7 8 9 1. Fig.9. The Polarity Effect in the rod-plate arrangement with the rod grounded. 4.2 The influence of the Ground Effect. The grounding of one of the electrodes influences the corona onset voltage significantly depending on the gap length, as well as the rod s and the plate s diameter. Effect. When the rod is grounded the rod is positive in relation to the plate and thus the influence of the Polarity Effect is added to that of the Ground Effect. The relation between the field strength on the rod (maximum value of field strength in the gap) and the corona onset voltage is: V c-r-gr / V c-pl-gr =A*(E c-pl-gr /E c-r-gr ), where A 1 Corona Onset Voltage KV 7 6 4 3 2 1 Rod 4 mm, plate mm, DC (-). 1 2 3 4 5 6 7 8 9 1. 3 2 Field strength V/m 4.2.1. The applied voltage is positive DC. When the applied voltage is DC positive the corona onset voltage of the arrangement with the rod grounded is significantly higher than the arrangement with the plate grounded, as it is shown in figs 1. The Polarity Effect reduces the Ground Effect slightly. The relation between the field strength on the rod (maximum value of field strength in the gap) and the corona onset voltage is: V c-r-gr / V c-pl-gr =A*(E c-pl-gr /E c-r-gr ), where A<1 Voltage KV 7 6 4 3 2 1 Rod-plate air gap. Rod 4 mm, plate mm. DC(+). 1 2 3 4 5 6 7 8 9 1 Vc-r-gr (+) Er-r-gr Vc-pl-gr(+) Er-pl-gr 3 2 Field strength, V/m Fig 1. The Ground Effect for positive DC voltage. 4.2.2. The applied voltage is negative DC. When the applied voltage is DC negative the arrangement with the rod grounded appears much higher values of the corona onset voltage than in the arrangement with the plate grounded, as it is shown in figs 11. The Polarity Effect intensifies the Ground Voltage KV Vc-r-gr (-) Vc-pl-gr(-) Er-r-gr Er-pl-gr 4 3 2 1 ROD 6 mm, DC(-) 1 2 3 4 5 6 Vc-r-gr Vc-pl-gr Er-r-gr Er-pl-gr 2 Figs 11 The Ground Effect for negative DC voltage. 4.2.3. The applied voltage is AC. Voltage, KV ROD PLATE AIR GAP. ROD 6 mm, PLATE mm. AC Voltage. 4 35 3 25 2 15 1 5 1 2 3 4 5 6 7 8 9 Gap length, cm Fig 12. The Ground Effect for AC voltage 2 Field strength V/m Field strength V/m Vc-pl-gr Vc-r-gr Er -pl-gr Er-r-gr 5

When the applied voltage is AC the arrangement with the rod grounded appears much higher corona onset voltage than the arrangement with the plate grounded, as it is shown in fig 12. The Polarity Effect reduces the Ground Effect. The corona effects appear in negative half cycle, when the plate is grounded and in positive half cycle when the rod is grounded. The relation between the field strength on the rod (maximum value of field strength in the gap) and the corona onset voltage is: V c-r-gr / V c-pl-gr =A*(E c-pl-gr /E c-r-gr ), where A<1 4.3. The combined influence of the Ground and the Polarity Effect to the corona onset voltage of rodplate air gaps. The corona onset voltage is higher for the arrangement with the rod grounded in small rod-plate air gaps. This is in full agreement with the results of the analysis, by which it is concluded that the maximum value of the field strength in the arrangement with the rod grounded is comparatively lower (figs 3, 5, 6, 7, and 8). The Polarity Effect influences the Ground Effect slightly, as it is shown in fig 13. Corona Onset Voltage KV Rod-plate air gap. Rod 4 mm, plate mm. The Ground Effect. DC voltage. 7 6 4 3 2 1 G.E. P.E.-pl-gr P.E.- r-gr 1 2 3 4 5 6 7 8 9 1. Vc-r-gr (+) Vc-pl-gr(+) Vc-r-gr (-) Vc-pl-gr(-) Er-r-gr Er-pl-gr 3 2 Fig 13. The Ground Effect and the Polarity Effect in rod plate arrangements. 5 The influence of the Ground Effect to the breakdown voltage in rod plate air gaps. The Polarity Effect influences the breakdown voltage in relatively long air gaps in favor of DC voltage of negative polarity, because of intensive corona effects, [1], [2]. Field strength V/m Corona onset and Breakdown voltage KV Rod 6 mm, plate mm. DC(-) 8 6 4 2 Vc- pl-gr 1 2 3 4 5 6Vbr-pl-gr Vc-r-gr gap length cm Vbr-r-gr Fig. 14. Corona onset and breakdown voltage of rod plate arrangements with the rod or the plate grounded for negative DC applied voltage. Rod s diameter 6 mm. VOLTAGE KV Volatge KV Breakdown voltage KV 6 4 3 2 1 8 6 4 2 12 8 6 4 2 Rod 12 mm, AC Voltage. G.E. C.L.E. 1 2 3 4 5 6 7 GAP LENGTH cm,1,8,6,4,2 CURRENT ma Vbr-R-Gr Vbr-PL-Gr Ibr-R-Gr Ibr-PL-Gr Rod 1 mm, DC negative 1 2 3 4 5 6 7 8 6 4 Current, µα Vbr R-Gr Vbr, Pl-Gr Ic R-Gr Ic Pl - Gr. G. E. Rod 14 mm, DC (-) L.C.E. 1 2 3 4 5 6 7 8 9 Vbr-pl-gr-14 Vbr-r-gr-14 Ibr-pl-gr-14 Figs 15. The breakdown voltage in connection to the corona leakage current in rod-plate air gaps for the two different arrangements with the rod or the plate grounded, and for DC and AC voltage. 7 6 4 3 Leakage currebt µα 6

The Ground Effect influences the breakdown voltage in small air gaps. The breakdown voltage is higher for the arrangement with the rod grounded. This is in full agreement with the results of the analysis, by which it is concluded that the maximum value of the field strength in the arrangement with the rod grounded is comparatively lower (figs 3, 5, 6, and 7). We can say that the Ground Effect is overturned and the breakdown voltage increases significantly and becomes higher in the arrangement with the plate grounded, because of the influence of the corona leakage current (Polarity Effect) (figs 14, 15). The results are most significant and clearer when the breakdown voltage appears before the corona effects, and this happens when the gap length is very small. If the gap length is large enough the influence of the corona leakage current suppresses the Ground Effect, and the breakdown voltage is considerably higher in the arrangement with the plate grounded. The effect is stronger when the rod s diameter is very small, because in this case the corona leakage current is a lot higher. 6 Conclusions 1. The influence of the Ground Effect to the field distribution is intense in all rod-plate arrangements, and it grows stronger when the rod s and the plate s diameter is decreased and when the gap length is increased. This means that the inhomogeneity of the electric field influences the Ground Effect. That leads the maximum value of the field strength that usually appears on the rod and hence the value of the field factor to be high, and turn much higher when the arrangement is used with the plate grounded than with the rod grounded. The Ground Effect is negligible when the Plate s diameter is very large. 2. The Ground Effect influences the corona onset and the breakdown voltage of small rod-plate air gaps strongly. In the arrangement with the rod grounded, the corona onset voltage and the breakdown voltage are higher. 3. The Polarity Effect also influences the corona onset voltage, but in a different way, and reduces or reinforces the Ground Effect respectively. 4. A relation between the maximum value of the field strength on the rod and the corona onset as well as the breakdown voltage appears. 5. When the air gap is long enough and the corona leakage current is relatively high the Polarity Effect suppresses the Ground Effect and the breakdown voltage is higher for the arrangement with the plate grounded. 6. Future work will contain the full analysis of the Ground Effect for rod-plate air gaps of different geometries as far as the diameter of the rod and the plate is concerned, stressed by DC voltages of negative or positive polarity and AC voltages. The mathematical functions between the field strength and the breakdown voltage (dielectric strength) of the air gaps, as well as between the breakdown voltage of the gap and the corona leakage current through the gap will also be investigated. Acknowledgments. The project is co-funded by the European Social Fund & National Resources EPEAEK II, under the action 2.2.3z., Archimidis II. Special thanks to Stamatia Maglara, Konstantina Giannakopoulou, and Evaggelia Gani, who offered considerable help in experimental and simulation work and useful suggestions during the preparation of this paper. References: [1] Kuffel E., Zaengl W.S., Kuffel J., High Voltage Engineering. Fundamentals, Newnes Oxford,. [2] Khalifa M., High-Voltage Engineering, Theory and Practice, Marcel Dekker inc., New York, 199 [3] Maglaras A., Numerical analysis of electric field in air gaps, related to the Barrier Effect, 1 st IC- SCCE Athens, 4. [4] Maglaras A., Maglaras L., Modeling and analysis of electric field distribution in air gaps, stressed by breakdown voltage, WSEAS, MMACTEE Athens, 4 [5] Maglaras A., Maglaras L., Numerical Modeling and Analysis of electric field distribution in rod plate air gaps, with or without barrier, stressed by breakdown voltages, 1 st IC-EpsMsO, Athens, 5. [6] Maglaras A., Maglaras L., Experimental investigation along with simulation analysis of small rod plate air gaps with or without a Barrier. The Ground Effect, WSEAS - ISTASC Malta 5. [7] Maglaras A., Maglaras L., The Ground Effect influence to rod-plate air gaps with or without dielectric barrier, at breakdown, WSEAS TRANSACTIONS on SYSTEMS- Issue 11, Volume 4, November 5. [8] Maglaras A., Maglaras L, J. Drigojias Modeling and analysis along with experimental investigation of the Ground Effect in rod-plate air gaps with or without barrier. 5 th WSEAS/ IASME International Conference on ELECTRIC 7

POWER SYSTEMS, HIGH VOLTAGES, ELECTRIC MACHINES (POWER 5), Tenerife, 5. [9] Maglaras L, Maglaras A., J. Drigojias, Investigation of the Ground Effect in connection to the Barrier Effect in rod-plate air gaps. WSEAS TRANSACTIONS on POWER SYSTEMS, Issue 2, Volume 1, February 6. [1] Maglaras A, Maglara St. The Ground Effect and the corona leakage effect in correlation with the Polarity Effect in small rod-plate air gaps. WSEAS 5 th Conf. on Applications of Electrical Engineering (AEE 6). Prague, Czech Republic, 6. [11] Maglaras A, Maglara St. The Ground Effect in small rod-plate air gaps in connection to the corona effects and the Polarity Effect. WSEAS, TRANSACTIONS on SYSTEMS, Issue 5, Volume 5, May 6. [12] Ming Li, Leijon Mats and Bengtsson Tord, Barrier effects in air gaps under DC voltage. 7 th International Symposium on Gaseous dielectrics Knoxville, USA, 1994. [13] Ming Li, Leijon Mats and Bengtsson Tord, Factors influencing barrier effects in air gaps, Ninth International Symposium On High Voltage Engineering, Graz, Austria, 1995 [14] Topalis Fr., Danikas M., Breakdown in Air Gaps with Solid Insulating Barrier under Impulse Voltage Stress, FACTA UNIVERSITATIS (NIS), SER: ELEC. ENERG. Vol. 18, Apr. 5, 87-14. [15] Marx E., Der elektrische Durchshlag von Luft im unhomogenen Feid, Arch. f. El., vol. 24, 193, pp. 61f. [16] Roser, H., Schirme zur Erhohung der Durchschlagapannung in Luft, ETZ, vol. 17, 1932, pp. 411-412. [17] Hidaka K., Kouno, T. (1982), Method for measuring field in space charge by means of Pockel s device, J. Electrostatics vol. 11,1982, pp. 195-211 [18] Hidaka K., Chiba M., and Kouno T., Barrier effect on electrical breakdown in air, IX International Conference on Gas Discharges and their Applications, Venice, 1988, pp. 79-482. 8