INFRARED THERMOMETER TM0819

Similar documents
HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

InfraRed Thermometer with Laser Pointer

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

INFRARED THERMOMETER Model : TM-959

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Introduction Cautions

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Dual laser + type K thermometer INFRARED THERMOMETER

566/568. Infrared Thermometers. Getting Started

Infrared Thermometer Model CA879

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Manual Dew point scanner PCE-DPT 1

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

Instruction Manual SEFRAM Thermal Camera

INSTRUCTION MANUAL Fax: (503)

Non contact temperature measurement

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

Operating instructions Infrared temperature sensor TW20xx TW21xx

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Infrared Thermometer Model: and

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

63/66/68. Infrared Thermometers. Users Manual

Data Sheet / Instructions. Dewpoint MeterO

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Infrared Hand-Held Thermometers

INSTRUCTION MANUAL DTH Fax: (503)

Dewpoint Meter Data Sheet / Instructions

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum

GS-IR 8816 Series Infrared Thermometer

RADIATION-METER TM-91/TM-92

New! 2010 Model. Model No

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

User s Guide. Shown with Built-in Laser Sighting. OS531, OS532, OS533, OS534 OMEGASCOPE Handheld Infrared Thermometer

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

INSTRUCTION MANUAL INF Fax: (503)

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

IR-712 IR-720 IR-730

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Noncontact Thermometer

The Fluke 66 and 68 Infrared Thermometers

Every object with a temperature above 0 Kelvin= -273,15 C emits

Hadrons Desktop U.S. Atomic Clock & Weather Station

MANUAL TT-220 TT-220

INF195 Infrared Thermometer

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

U.S. Atomic Clock & Weather Station. Instruction Manual

IR/Thermistor Pen. Instruction Manual

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

IT Series Infrared thermometer Using manual

Infrared Hand-Held Thermometers

One-hand ph/temperature measuring instrument

High Accuracy High Speed in Your Process

OS534, OS530L, OS530HR OS523, OS524 OMEGASCOPE

Model DIT-516/517: OPERATING MANUAL

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

Rapid RH Portable ph Meter. User's Manual

THERMYS 150. Advanced field reference thermometer / temperature calibrator

CHIP RESISTOR. Chip Resistors Selection Guide. General Purpose Chip Resistor. Zero Ohm Jumper Resistor. Chip Resistor Array MAX WORKING VOLTAGE

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

OS534E, OS530HRE, OS523E, OS524E OMEGASCOPE

Lab Activity H4 It s Snow Big Deal

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

R I T. Title: GCA Stepper Operations. Semiconductor & Microsystems Fabrication Laboratory Revision: F Rev Date: 08/09/ SCOPE

optris LaserSight Operators manual

Today s Weather 24 Hour Forecaster

Infrared Thermosensor ES1C

Emissivity and Remote Sensing

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

IR-750. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok. 50:1 IR Thermometer with memory

Xenics Presentation. A 25 minute crash course in Thermography

Ion-Chamber Survey Meter OD-02

Emissivity: Understanding the difference between apparent and actual infrared temperatures

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

Bright Advance Corporation

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

Thermography Pocket Guide. Theory Practice Tips & Tricks

473 Dew Point Hygrometer

L E A. Laser Elemental Analyzer

CHALLENGE #1: ROAD CONDITIONS

Understand FORWARD COLLISION WARNING WHAT IS IT? HOW DOES IT WORK? HOW TO USE IT?

WeatherHub2 Quick Start Guide

Individual Laboratory Safety & Chemical Hygiene Plan

Dielectric Analysis of Solid Insulations

Ground Penetrating Radar & By Mike Kelty Western Technologies Inc.

Gebrauchsanleitung. Operating instructions. Gebruiksaanwijzing. Mode d'emploi. Istruzione d'uso. Instrucciones de manejo

(PT-A6) Visible Light Detector for Security Lighting

473 Dew Point Hygrometer

(PT-A6) Visible Light Detector for Security Lighting

MICROLIFE THERMO+ Infrared Thermometer. For safe, touch-free temperature measurement. Instruction Manual

Transcription:

INFRARED THERMOMETER Instruction Manual HORMES LIMITED cs@perfectprime.com G/F UNIT 3, 61 GLENTHORNE ROAD, LONDON W6 0LJ UNITED KINGDOM +44 203 7695377 Retailer Email Address Telephone

P.1 CONTENTS 1. Production Introduction 2. Safety 3. Product Description 4. Show 5. Operation Instruction 6. Attention 7. Distance Coefficient Ratio 8. Emissivity and Infrared Temperature Measurement Principle 9. Emissivity values of common materials 10. Specification 2 2 3 3 4 7 8 8 9 10

P.2 1. Production Introduction Many thanks for choosing our product. is an infrared thermometer that can provide an accurate result of temperature measurement with the help of laser beam. The following are the major features of : High accuracy: Equipped with high-quality sensor to measure the amount of infrared radiation from objects. Time-saving : Only a press on the trigger is needed for measurement. User-friendly : Laser beam allows you to aim at objects more easily. Adjustable: Maximum and minimum temperatures can be displayed. is the ideal selection for electrician, maintenance personnel, technicians and even the emergency personnel. 2. Safety Be cautious when laser is working Do not point directly into eyes or anything that can reflect the laser beam into eyes. Do not point the laser directly at the explosive gas or flammable goods.

P.3 3. Product Description 1 1. Dual Laser Targeting 2. LCD display 3. Function Menu 4. Measuring trigger 5. Battery cover 2 3 4 5 4. Show 1 1. Scanning and measuring procedure 2. Hold and keep the last measuring data 3. Emissivity setting 4. F and C swift 5. Main temperature display 6. Low voltage warning 7. Function transformation zone 2 6 SCAN HOLD ε=0.95 8.8.8.8 LOG 8.8.8.8 8.8.8.8 C F 3 4 5 7

P.4 5. Operation Instruction 5.1 Temperature Measuring 1. Point the instrument to the surface of the object and press the trigger. 2. It can display temperature, max temperature, min temperature, difference value, average value, max warning point, min warning point, external probe (not included in this product) measurement unit. 3. The measuring result will stay on the screen for 7 sec after the trigger is released and it will power off if there is no other operation. Notice: Press the "MODE" button for 2 sec when the instrument is on to swift between F and C. 5.2 Dual laser spot Dual laser distance is within 120cm, the temperature measured is 10cm in diameter at this distance. 5.3 Dual laser's on and off 1. Press and release the trigger 2. When "hold" is displayed, press the laser backlit button to power on and off the laser and to switch the backlit. @160mm 15mm @60cm 5cm @120cm 10cm

P.5 5. Operation Instruction 5.4 Max Temperature Display The max temperature is displayed in "MAX" after the temperature measurement is finished. 5.5 Backlight 1. Press and release trigger 2. Press the backlit button when the screen shows "HOLD" to switch backlit. 3. When the backlit is on, it will light up the screen. 4. Backlit will be remained stored stage until it change to another model. Press up and down button to adjust emissivity when it shows "HOLD". The emissivity of this instrumentis between 0.1-1.0. Remark: backlit will consume the power of battery. Turn it off when you need not. 5.6 MODE menu operation 1. It can enter max value, min value, average value, max alarm point, min alarm point, external probe (not used). 2. Press and release the trigger when it shows "HOLD". Press the "MODE" to enter the next program.

P.6 5. Operation Instruction Max Data Min Data Difference Average data HAL LAL Only shows the max data when measuring. Only shows the min data when measuring. Shows the difference between the first and subsequent data. Shows the average between the first and subsequent data. To set the max alarm temperature, press the up and down menu. To set the min alarm temperature, press the up and down menu. This product can alarm when the temperature is too high or too low. It can make a sound to remind the users. You can set the alarm temperature through the "MODE" menu. Setting will be saved even when device is turned off. 5.7 Temperature Unit F and C can be set by the temperature unit switch menu, press the MODE menu for 2 sec. 5.8 Above read range function If the temperature is beyond the read range, it will shows "----" on the screen.

P.7 5. Operation Instruction 5.9 Battery replacement When it shows low power signals "LOG", please replace battery (9V). The battery is located under the trigger. Properly dispose of the battery. 6. Attention The object being measured must be larger than the vision field of the instrument. Keep the object surface clean and free from frost, oil and dirt etc. when measuring. If the object's surface is reflective, cover with adhesive tape or black paint before measuring. If the object is transparent such as glass it may not have an accurate result. Steam, dust, smog etc. will influence the measuring result. This instrument can adjust the environment temperature deviation. But if the deviation is huge it may take about 30 minutes to adjust. To find the hot spot please point the object from top to bottom and from left to right until found.

P.8 7. Distance Coefficient Ratio The distance coefficient ratio of this product is 12.1. For example, if the object to be measured is 72cm far from the instrument, then the diameter of the object must be larger than 6cm. It can measure proper distance but can be influenced by other light source. 8. Emissivity and Infrared Temperature Measurement Principle Infrared thermometer is an instrument that measures the surface temperature. It is through infrared emission, reflection and then converted into energy. Thermometer converts the electrical signals into temperature reading displayed on the LCD. The infrared energy released is in direct proportion with its temperature and emissive power. This is called emissivity. It is related to the material and gloss of the object. The emissivity value ranges from 0.1 to 1.0. The emissivity of most organic material; paint and the surface be oxidized is 0.95. If there is a problem please set the emissivity to be 0.95.

P.9 9. Emissivity values of common materials Material Under Test Emissivity Material Under Test Emissivity Asphalt 0.90-0.98 Cloth (black) 0.98 Concrete 0.94 skin (human) 0.98 Cement 0.96 Lather 0.75-0.80 Sand 0.90 Charcoal (powder) 0.96 Soil 0.92-0.96 Lacquer 0.80-0.95 Water 0.92-0.96 Lacquer (matte) 0.97 Ice 0.96-0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85-0.95 Glass 0.90-0.95 Timber 0.90 Ceramics 0.90-0.94 Paper 0.70-0.94 Marble 0.94 Chromium oxides 0.81 Plaster 0.80-0.90 Copper oxides 0.78 Mortar 0.89-0.91 Iron oxides 0.78-0.82 Brick 0.93-0.96 Textiles 0.90

P.10 10. Specification Max Data Range -50 to 1050 C -58 to 1922 F Resolution 0.1 < 1000, 1 > 1000 Accuracy -50 C to -23 C (-58 F to -10 F) ±7 C/14 F (Typical) -23 C to -2 C (-10 F to 28 F) ±4 C/8 F -2 C to 94 C (28 F to 200 F) ±2.5 C/4.5 F 94 C to 204 C (200 F to 400 F) ±(1.0%rdg + 1 C/2 F) 204 C to 426 C (400 F to 800 F) ±(1.5%rdg + 1 C/2 F) 426 C to 1050 C (800 F to 1922 F) ±(3%rdg + 1 C/2 F) Note: Accuracy is specified for the following ambient temperature range: 23 to 25 C (73 to 77 F) Emissivity Field of View Laser pointer IR Spectral response Repeatability 0.10 to 1.00 adjustable D/S = Approx. 12:1 ratio (D = distance; S = spot or target) Dual, Class 2 laser < 1mW power; Wavelength is 630 to 670nm 8 to 14 µm (wavelength) ± 0.5% of reading or ± 1 C (1.8 F) whichever is greater

P.11 11. General Specifications Display Backlit LCD display with function indicators Response Time 150ms Beyond Read Range Indication "------" Operating Temperature 0 C to 50 C (32 F to 122 F) Operating Humidity 10% to 90% RH operating, <80% RH storage Storage Temperature -10 to 60 C (14 to 140 F) Power Supply 9V battery Automatic Power Off 7 seconds, with LOCK to disable Weight 150g Dimensions 180 x 107 x 40mm

P.12 CONTACT US WHATEVER YOUR QUESTION, WE RE HERE TO HELP CUSTOMER SERVICE INQUIRIES Your emails are important to us so we strive to reply all inquiries and emails within 24 hours. In exceptional cases, we may require more time to respond. Thank you for your understanding. For more information about our products and services please fill out the form below or alternatively send us an email: cs@perfectprime.com For B2B or project-based application, please send an email: sales@perfectprime.com FOR MORE INFORMATION ABOUT PERFECT PRIME PLEASE VISIT OUR ABOUT US PAGE AND FEEL FREE TO BROWSE.