of Fe( II )-l,10-phenanthrol I ne complex at 510 nm.

Similar documents
Spectrophotometric Determination of Anionic Surfactants in River Water with Cationic Azo Dye by Solvent Extraction- Flow Injection Analysis

HI. IN A CONFLUENCE CONFIGURATION +

Flow Injection Analysis for the Determination of Ammonia in Exhaust Gas of Thermal Power Plant

MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS

Iron Catalyzed Chlorpromazine-Hydrogen

Sodium Chloride - Analytical Standard

Chemistry Department Faculty Publication Series

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

Study on the interaction behavior of catalase with. cephalosporins by chemiluminescence with flow injection

(Received 2 December 2003, Accepted 4 February 2004)

Chemistry Instrumental Analysis Lecture 31. Chem 4631

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

A New On-line Cyanide Analyzer for Measurement of Cyanide in Hydrometallurgical Processing of Precious Metal Ores

Reverse Flow Injection Analysis for Determination of Manganese(II) in Natural Water. Jintana Klamtet

Lab #12: Determination of a Chemical Equilibrium Constant

Chemistry Gas Chromatography: Separation of Volatile Organics

Natural montmorillonite nanosheet colloid-catalyzed hydrogen peroxide

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Method for Nitrite determination on Low-Range Samples

ASPARTAME. Not less than 98% and not more than 102% on the dried basis. White, odourless, crystalline powder, having a strong sweet taste

[Unless otherwise stated all tolerances are ±5%] SAMPLES

METHOD 9012 TOTAL AND AMENABLE CYANIDE (COLORIMETRIC, AUTOMATED UV)

Chapter 3 Electrochemical methods of Analysis-Potentiometry

Annex 2 Formaldehyde

Title Application to the Analysis of Sea- Author(s) Ishibashi, Masayoshi; Hara,

Supporting Information for. Suppression of OH Generation from the Photo-Fenton Reaction in the Presence of α-pinene Secondary Organic Aerosol Material

Method for estimation of iodine in urine

TRICHLOROETHYLENE IN URINE BY GC/MS Headspace Code GC16110

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

Fast Determination of Impurities in Propane- Propylene Streams Using a Pulsed Flame Photometric Detector (PFPD) and a New Capillary.

THE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

The Synthesis and Analysis of Aspirin

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

Sodium Chloride - Analytical Standard

2 (aq) [FeSCN [Fe 3JSCN] Figure 1

Volumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

If you like us, please share us on social media. The latest UCD Hyperlibrary newsletter is now complete, check it out.

Spectrophotometric Determination of Iron

GB/T Translated English of Chinese Standard: GB/T

H 3 CO H 3 CO S CH 3

Determination of Polymer Modifier in Asphalt

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

This method describes the identification of the following prohibited colorants in cosmetic products:

Kinetic Isotope Effects

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Determination of Caffeine by HPLC

Application of Micro-Flow Imaging (MFI TM ) to The Analysis of Particles in Parenteral Fluids. October 2006 Ottawa, Canada

METHYLISOBUTYLKETONE (4-methyl-2 pentanone) IN URINE BY GC/MS Headspace Code GC10510

Continuous Flow Analysis Methods David Davey University of South Australia. 21 February

EXPERIMENT 5: PHOTOMETRIC DETERMINATION OF AN EQUILIBRIUM CONSTANT

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

FLOW 1.NJECTION METHOD COUPLED WITH SOLVENT EXTRACTION USING, ON-TUBE VISIBLE ABSORPTION AND APPLICATION TO THE DETERMINATION OF 'ANIONIC SURFACTANTS

Analytical method related to authorised feed additive - 1i534

The Determination of an Equilibrium Constant

METHOD 9035 SULFATE (COLORIMETRIC, AUTOMATED, CHLORANILATE)

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Western Carolina University

Figure 1. Structures for Vitamin B2 and Vitamin B1.

METHOD #: Approved for NPDES and SDWA (Ed. Rev. 1974, 1978) Fluoride, Total (Colorimetric, SPADNS with Bellack Distillation)

Controlled self-assembly of graphene oxide on a remote aluminum foil

Lab #16: Determination of the Equilibrium Name: Constant of FeSCN 2+ Lab Exercise. 10 points USE BLUE/BLACK INK!!!! Date: Hour:

Spectroscopy of Various Light Sources: The Interactions between Light and Matter ASTR 170B1, Spring 2017, Lab #2. 1 Introduction.

Water Hardness and Softening (Bring a water sample from home) Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.2.

Sulfotepp impurities in Chlorpyrifos EC formulations

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

For this lab, you will determine the purity of the aspirin by titration and by spectrophotometric analysis.

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

COMPARISON OF MIGRATION AND REACTIVATION PROPERTIES OF NEW TYPES OF IRON NANOPARTICLES. Jaroslav Nosek, Kristýna Pešková, Zuzana Masopustová

The Determination of an Equilibrium Constant

Sodium Chloride - Analytical Standard

MOF-76: From Luminescent Probe to Highly Efficient U VI Sorption Material

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

EXAMINATION QUESTIONS (6)

Metal-organic frameworks (MOFs) as precursors towards TiO x /C. composites for photodegradation of organic dye

CHAPTER 3 MATERIALS AND METHODS

ANALYTICAL SCIENCES MAY 2004, VOL The Japan Society for Analytical Chemistry

Automated Clinical Analyzer

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

ICP-OES DETERMINATION OF IRON. Introduction:

Chemistry Instrumental Analysis Lecture 27. Chem 4631

high temp ( K) Chapter 20: Atomic Spectroscopy

FLAME PHOTOMETRY AIM INTRODUCTION

Contents. Efficient synthesis of 5-(chloromethyl)furfural (CMF) from high fructose corn syrup (HFCS) using continuous flow processing

ActiPix SDI300 Surface Dissolution Imaging System

Aspirin Synthesis H 3 PO 4

Preparation of Standard Curves. Principle

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

CIE Chemistry A-Level Practicals for Papers 3 and 5

Sample Question Answers - Unit 1

AE 3051, Lab #16. Investigation of the Ideal Gas State Equation. By: George P. Burdell. Group E3

LUMEFANTRINUM LUMEFANTRINE

Sample Analysis Design. Solution Mode

Fluorescence Detection-FIA for ppb Levels of Bromate with Trifluoperazine

High Performance Liquid Chromatography

Transcription:

J. Flow Injection Anal., Vol -10, No. 1 (1993) HIGHLY SENSITIVE FLOW INJECTION ANALYSIS KYOJ I TOE I, SH I NME I H I RA I SH I, TAKAHARU NAKAGAWA and M I CH 10 ZENK I Department of Chemistry, Faculty of Science, Okayama University of Science, 1-1, Ridai-cho, Okayama 700, JAPAN ABSTRACT Highly sensitive flow injection analysis (F1A) was developed with a pulseless double plunger micro pump. Carrier and reagent solutions were emitted alternatively 4.9,u 1 each. The whole manifold was kept at a constant temperature (25.0 T) in an air bath. To eliminate a micro pulse, l i ne f i l ters, a reaction co i l packed with glass beads and an ai r damper were equipped. The constant electric voltage was kept constant with an electric stabilizer. Iron of ug I"^ (ppb) level could be determined by measuring the absorbance of Fe( II )-l,10-phenanthrol I ne complex at 510 nm. The sensitivity could be enhanced up to 1000 times electrically. I NTRODUCT I ON Double stream flow injection manifold has been widely employed in Japan and a pulseless double plunger micro pump is used to propel carrier and reagent solutions instead of peristaltic pump, because pulseless pumps are commercially available and the sample solution and reagent solution can be mixed accurately and rapidly. If the solutions are mixed completely and electrical pulses are small, the basaline on chart should be pulseless and stable. In such case, the peaks of sample are accurate and reproducible. However, the output is affected strongly by temperature change at high sensitivity, thus whole system should be kept at a constant temperature (25.0 TI. The absorbance of l ron( U)-l,10-phenanthrol ine complex was

measured at 510 nm and several ppb of Fe(II) could be determined with good reproduc i b i I i ty. EXPERIMENTAL A~para tus PTFE tube (0.5 mu i.d.) was used for whole flow system except back pressure coil (0.25 mm i.d.1. A pulseless double plunger micro pump (DM2M- 1026, Sanuki Kogyo, Tokyo) was used. The plunger diameter was 2.5 mm and the stroke 1 mm. The suction and emission mode is shown in Fig. 1. With this pump any damper tube or air damper is not usual ly necessary, and sample and reagent solutions are mixed quickly in a reaction tube. There- fore a 50cm ofreaction co1-1 was- enough between -the mixing --job-it and the flow cell. The flow rate of 1.65 ml min'l was employed. A ceramic six-way Fig. 1 Working mode of DM2M-1026 pump (A) and stream in PTFE tube (B). Sol id l ine: sample solution, Broken line: reagent solution.

injector (STM-6M2L, Sanuki Kogyo) was used. The dead volume was 4 u\, and the volume of injected sample solution was 188 yl. A visible s~ectrophotometer (400-800 nm, S-3250, Soma Kogaku, Tokyo) with a titanium flow cell (0.5 mm i.d., l ight-path length 10 mm) was used. A recorder (Nippon Denshi Kogaku, U228, Tokyo)was used with chart speed 15 cm h'l. Reagents (NH&S04FeS04*6H20 (0.7022g) was d issol ved in d i st i l led water con- taining hydorochloric acid (1 mlland sodium ascorbate (1 g), and the solu- tion was diluted exactly to 1 1. This solution was containing 100 mg I"^ Fe(n). The standard solution was diluted to prepare a series of 25, 20, 15, 10, 5 and 0 ppb Fe(II) solutions and another series of 10, 8, 6, 4, 2 and 0 ppb Fe(n) solutions for 500 times and 1000 times sensitivity, respectively. The regent solution was composed of 1,lO-phenathrolinium chloride monohydrate (1 g), sodium ascorbate (1 g) and 0.1 ml hydorochloric acid in 1 1 distilled water. Carrier (distilled water), and the reagent solution were filtered through a membrane filter (pore size 0.45 U. m, Toyo Roshi, Tokyo). A sample so ution was injected through a dis- posable syringe f i l ter Dismic-3CP (pore s Highly Sensitive FIA ze 0.45,um, Toyo Roshi). The FIA manifold used is shown in F g. 2. To keep a constant tempera- ture (25.0 Â C the spectrophotometer and the double plunger micro pump were set in an ai r bath (60 X 60 X 30 cm) made by wood. Warm ai r from a tungsten lamp in the spectrophotometer was blown to a radiator (25X 9 X 3.5 cm) with a fan, in which lower temperature water circulated from a water bath outside the box, and another fan stirred air in the box. The temperature in the box was exactly adjusted to 25.0 T by the outside water bath (below 25 Â C roughly and by controlling the circulatng water speed inely. To prevent a micro pulse from the pump, the carrier and reagent solu ions passed through line filters which are made by sintered PTFE powder

Fig. 2 Highly sensitive FIA manifold. CS: carrier solution, RS: reagent solution, P: double plunger micro pump, LF: line filter, IV: injection valve, S: sample solution, M: mixing joint, RC: reaction coil, AD: air damper, FC: flow cell, SP: spectrophotometer, R: recorder, BPC back pressure coi l (0.25 mm i.d.), WB: water bath (25.0 '0, AB: air bath (25.0 Â C) packings (diameter 4 mm, thickness 2 mm, GL Sciences, Tokyo). To el iminate aslight pulse, a 50cm PTFE tube (1 mm i.d.) packed with glass beads (diameter 0.6 mm) was used as a reaction coi I. After the reaction coi l an air damper with 1 m PTFE tube (0.5 mm i.d.) was placed (Fig. 2). Line filters, mixing joint, reaction coil, air damper and injection valve were kept in a water bath (25.0 T) together with carrier and reagent solution bottles. To prevent electric noises, an electric stabi l izer(svc-1010, Mat- sunaga Manufacturing Co. Ltd.) was used, and the spectrophotometer, the pump and the recorder were earthed. When the base l i ne on a record i ng paper becomes constant and noise less at e levated sensitivity of the detector, sample solutions were injected and reproducible and constant absorbances were obtained. The sample solutions vessel was stoppered to prevent the contamination of i ron from room a i r.

RESULTS AND DISCUSS I ON When the temperature controller was not used, the sensitivity could be enhanced up to 10 or 20 times by the sensitivity knob of the spectrophotometer. However, cool or warm wind from an ai r conditioner, should be avoid, because the baseline was fairly affected by the temperature change. Sample solution injected flows rapidly at the center of the tube but slowly near the tube wall. Therefore, the sample solution can be mixed with the reagent solution rapidly, and the mixing is complete even in a shorter react ion coi l than 50 cm. When other commercial l y avai lab1 e pumps are employed, the emission volume at each stroke is about 100 ul which occupies 50 cm of PTFE tubing (0.5 mm i.d.1 and the mixing occurs only at the boundary. Thus the mixing may be incomplete if a 1 in PTFE reaction coi l is equipped. The pump employed in this study emitted only 4.9 yi solution at each stroke, that corresponds to 2.5 cm of tube. If the stable baseline and the reproducible peaks can be obtained, the highly sensitive detection can be performed when the out-put of the spectrophotometer is enhanced. By using the line filters, a reaction coil packed with glass beads, an air damper and the water bath and air bath, the reproducible peaks and stable base l i ne were obtained. By using this FIA system, iron at ppb levels was determind. The calibration outputs are shown in Fig. 3A and B. The correlation coefficients were A: 0.9999 and B: 0.9975, respectively. This method could be appl ied to the determi nation of ppb- level iron. Sensitivity of FIA can be improved by employing this flow system, and sample at ppb revels can be determined correctly and rapidly.

Fig. 3 Cal ibration graphs of Fe( U) by 1,lo-phenanthrol ine. A: 500 times, B: 1000 times. ACKNOWLEDGMENT The authors thank Mr. S. Sanuki, the president of Sanuki Kogyo K.Ki, for his technical assistance. (Accepted 17 March, 1993)